NEW Modular Plug Connectors Compliant to Enhanced Category 5 Standards TM21P Series (Shielded Type) TM22P-88P (Non-shielded Type) ■Features 1. Supports High-Speed LAN Transmission Conforms to requirements of TIA/EIA-568B data wiring standard, meeting transmission performance of Enhanced Category 5. Supports Gigabit Ethernet (1000BASE-T) and Fast Ethernet (100BASE-TX) high-speed LAN transmission. Protected latch tab 2. EMI protection (TM21*P-88P) 360° coverage of the engagement area with a metal shield assures protection against electromagnetic interference. When mated with corresponding connector the shield surfaces are securely connected to provide continuous circuit. 3. Protected latch tab (TM21P-88P) Flexible case extends over the release tab preventing the possibility of breaking-off during handling of the complete cable assembly. 4. Termination of conductors ① Self located 24 AWG conductors (solid or stranded) are terminated against pre-inserted contacts using simple tooling. 5. Simplified termination (TM21*P-88P) Removeable one piece cover allows easy access to the termination areas. 6. Conforms to the ISO 8877 Standard (ISDN Interface Connector) ② ① ① ■Applications Telecom Hubs, Routers, Bridges and ATM Transmission Equipment, Ethernet Switches and Networking Equipment, Test and Measurement Equipment and other equipment requiring this type of simple and reliable connection. Cover Installation Procedure 2002.11 1 ■Product Specification Current rating 1A Voltage rating 125 V AC Operating temperature range-25ç to +60ç (Note) Rating Item Specification Conditions 1. Insulation resistance 100 M ohms min. 100 V DC 2. Withstanding voltage (between adjacent contacts) No flashover or insulation breakdown 500 V AC / one minute 3. Withstanding voltage (between contact and shield) No flashover or insulation breakdown 1500 V AC / one minute 4. Contact resistance 230 m ohms max. 100mA DC 5. Vibration No electrical discontinuity of 5 ms or more Contact resistance: 250m ohms max. Frequency: 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours / 3 axis No electrical discontinuity of 5 ms. min. Contact resistance: 250m ohms max. Acceleration of 490 m/s2, 11 ms duration, sine half-wave waveform, 3 cycles in each of the 3 axis 7. Durability (mating/un-mating) Contact resistance: 250m ohms max. 200 8. Temperature cycle Contact resistance: 250 m ohms max. 6. Shock Temperature: -55ç/+5ç to +35ç/+85ç/+5ç to +35ç Duration: 30/5/30/5(Minutes) 5 cycles Insulation resistance: 100 M ohms min. 9. Humidity 10. Salt Spray Contact resistance: 250 m ohms max. Insulation resistance: 1 M ohms min. (High humidity) Insulation resistance: 10 M ohms min. (Dry state) 500 hours at temperature of 40ç and humidity of 90% to 95% Contact resistance: 250 m ohms max. Exposed to density 5% salt water for 48 hours Note :Includes temperature rise caused by current flow. ■Materials Part Material Finish Remarks Insulator Polycarbonate Color: Clear UL94V-2 Contacts Copper alloy Contact area: Gold plating ------- Shield Conductor holding tray Copper alloy Solder plating ------- Polycarbonate Color: Clear UL94V-2 Polyamide Color: Light beige (Note) UL94V-2 Cover Note :Cover available in various colors. Refer to page 3. ■Ordering information ●Plugs- Shielded ●Plugs - Non-shielded TM21 C P - 8 8P 1 1 Series name 2 2 1 3 TM22P - 8 8P 4 1 2 3 TM21P: Shielded 1 Series name TM22P : Non-shielded 2 Cover Type Blank: Protective latch cover 2 Size 8 : For 8 contacts C: Short cover 3 Inserted contacts 8P: 8 3 Size 8: For 8 contacts 4 Inserted contacts 8P: 8 ■Plug Connectors ●Shielded Cover (34) 30.2 9 16.6 11.7 6.09 ) 3.5 (R 6.7 Conductor holding tray Contact No. 1 3.45 29.5 (0.6) 6.6 12.9 17.5 Contact No.8 5.4 9.05 CL No. Cover Color TM21P-88P Part Number 222-2862-9-02 Light beige TM21P-88P(02) 222-2862-9-02 Medium gray TM21P-88P(03) 222-2862-9-03 Black TM21P-88P(04) 222-2862-9-04 Natural light gray TM21P-88P(05) 222-2862-9-05 Red TM21P-88P(06) 222-2862-9-06 Green TM21P-88P(07) 222-2862-9-07 Blue TM21P-88P(08) 222-2862-9-08 Yellow TM21P-88P(09) 222-2862-9-09 Orange BCover installed BMated with corresponding receptacle (shown for reference only) (34) (13.4) (44.65) 3 ■Plug Connectors ●Shielded-Short Cover 6.7 17.2 TM21CP-8 9 3. 5) TM21CP-8 30.2 10.4 (22.4) 11.7 6.09 Cover Conductor holding tray 3.45 12.9 (0.6) 6.6 (R 17.5 Contact No.8 Contact No.1 5.4 9.05 Part Number CL No. Cover color TM21CP-88P(03) 222-2884-1-03 Black Note: For other colors contact Hirose sales representative. BCover installed BMated with corresponding receptacle (shown for reference only) (21.7) TM21CP-8 TM21CP-8 (32.35) (13.4 ) BApplicable Shielded Cable Specifications Specifications Solid copper conductor: 0.5mm dia. Jacket Conductor Shield Stranded copper conductor: AWG#24 (Dia. 0.2mm x 7 pcs) Insulation Conductor Individual conductor insulation dia. (0.9mm to 1.0mm) Drain wire AWG#26 (tin coated) Overall jacket dia. (dia. 6.6mm) Drain wire Note: For cable termination procedures refer to: [TM21P-88P Cable Termination Procedure Manual] (ETA-E2349) and [TM21CP-88P Cable termination Procedure Manual] (ETA-E2353). Some cables may not meet the required service ratings. Contact Hirose sales representative for specific cable applications recommendations. 4 ■Plug Connectors ●Non-shielded 11.7 Conductor holding tray 6.6 9.05 (0.6) 7.9 14.2 5.4 3.45 6.09 22.5 Contact No.1 Part Number CL No. TM22P-88P 222-2899-9 Contact No.8 BMated with corresponding receptacle (shown for reference only) (11.85) BApplicable Non-shielded Cable Specifications Specifications Solid copper conductor: 0.5mm dia. Jacket Conductor Stranded copper conductor: AWG#24 (Dia. 0.2mm x 7 pcs) Individual conductor insulation dia. (0.9mm to 1.0mm) Overall jacket dia. (dia. 5.4mm to 5.7mm) Conductor Insulation Note: For cable termination procedures refer to: [TM22P-88P Cable Termination Procedure Manual] (ETA-E2381). Some cables may not meet the required service ratings. Contact Hirose sales representative for specific cable applications recommendations. 5 BHand termination tools ●For contact/conductor termination Part Number CL No. HT205/TM21P-88P 250-0234-4 ●For cable and shield crimping (Shielded connectors only) Part Number CL No. HT206/TM21P-88P 250-0235-7 ●For contact/conductor termination (Non-shielded connectors) Part Number CL No. HT501/TMP-88 902-2111-9* *Scheduled for release soon. Please contact your Hirose Electric account representative for information. 6 BTechnical Documentation ●CAT5e Transmission Characteristics Data These are the representative values of the various transmission characteristics data for connector assemblies TM21P-88P and TM21R-5C-88-LP when fully mated. All plugs in the TM21R-5C Series that were manufactured based on the De-embedded method of the TIA/EIA568-B.2 standard meet requirements of CAT5e single transmission performance. • Signal Attenuation Attenuation(dB) 0.5 0.4 0.3 0.2 0.1 0 0 10 20 30 40 50 60 70 80 90 100 Frequency(MHz) 1,2 3,6 4,5 7,8 CAT5e Spec (Each two numbers are for the pair of individual contact position.) • Near-End Crosstalk Attenuation (NEXT) 120 NEXT(dB) 100 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 100 Frequency(MHz) 1,2-3,6 1,2-4,5 1,2-7,8 3,6-4,5 3,6-7,8 4,5-7,8 CAT5e Spec • Return Loss Return Loss(dB) 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 100 Frequency(MHz) 1,2 3,6 4,5 7,8 CAT5e Spec 7 • Far-End Crosstalk Attenuation (FEXT) 120 100 FEXT(dB) 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 100 Frequency(MHz) 1,2-3,6 3,6-4,5 4,5-7,8 CAT-5e Spec 1,2-4,5 3,6-7,8 7,8-1,2 1,2-7,8 4,5-1,2 7,8-3,6 3,6-1,2 4,5-3,6 7,8-4,5 (Each two numbers are for pair of individual contact position.) • Propagation Delay 3 Delay(ns) 2.5 2 1.5 1 0.5 0 0 10 20 30 40 50 60 70 80 90 100 Frequency(MHz) 1,2 3,6 4,5 7,8 CAT5e Spec • Propagation Delay skew 1.4 Delay Skew(ns) 1.2 1 0.8 0.6 0.4 0.2 0 0 10 20 30 40 50 60 70 80 90 100 Frequency(MHz) 8 ks to World El e Lin onics ctr Creativ e Measurement Value CAT5e Spec HIROSE ELECTRIC CO., LTD. 5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN PHONE:81-3-3491-9741 FAX:81-3-3493-2933 http://www.hirose.com The contents of this catalog are current as of date of publication. Contents are subject to change without notice for the purpose of improvements.