HRS TM22P-88P

NEW
Modular Plug Connectors Compliant to Enhanced Category 5 Standards
TM21P Series (Shielded Type)
TM22P-88P (Non-shielded Type)
■Features
1. Supports High-Speed LAN Transmission
Conforms to requirements of TIA/EIA-568B data
wiring standard, meeting transmission performance
of Enhanced Category 5.
Supports Gigabit Ethernet (1000BASE-T) and Fast
Ethernet (100BASE-TX) high-speed LAN
transmission.
Protected latch tab
2. EMI protection (TM21*P-88P)
360° coverage of the engagement area with a metal
shield assures protection against electromagnetic
interference. When mated with corresponding
connector the shield surfaces are securely
connected to provide continuous circuit.
3. Protected latch tab (TM21P-88P)
Flexible case extends over the release tab
preventing the possibility of breaking-off during
handling of the complete cable assembly.
4. Termination of conductors
①
Self located 24 AWG conductors (solid or stranded)
are terminated against pre-inserted contacts using
simple tooling.
5. Simplified termination (TM21*P-88P)
Removeable one piece cover allows easy access to
the termination areas.
6. Conforms to the ISO 8877 Standard
(ISDN Interface Connector)
②
①
①
■Applications
Telecom Hubs, Routers, Bridges and ATM
Transmission Equipment, Ethernet Switches and
Networking Equipment, Test and Measurement
Equipment and other equipment requiring this type of
simple and reliable connection.
Cover Installation Procedure
2002.11
1
■Product Specification
Current rating
1A
Voltage rating
125 V AC
Operating temperature range-25ç to +60ç (Note)
Rating
Item
Specification
Conditions
1. Insulation resistance
100 M ohms min.
100 V DC
2. Withstanding voltage
(between adjacent contacts)
No flashover or insulation breakdown
500 V AC / one minute
3. Withstanding voltage
(between contact and shield)
No flashover or insulation breakdown
1500 V AC / one minute
4. Contact resistance
230 m ohms max.
100mA DC
5. Vibration
No electrical discontinuity of 5 ms or more
Contact resistance: 250m ohms max.
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
2 hours / 3 axis
No electrical discontinuity of 5 ms. min.
Contact resistance: 250m ohms max.
Acceleration of 490 m/s2, 11 ms duration,
sine half-wave waveform, 3 cycles in each of the 3 axis
7. Durability
(mating/un-mating)
Contact resistance: 250m ohms max.
200
8. Temperature cycle
Contact resistance: 250 m ohms max.
6. Shock
Temperature: -55ç/+5ç to +35ç/+85ç/+5ç to +35ç
Duration: 30/5/30/5(Minutes)
5 cycles
Insulation resistance: 100 M ohms min.
9. Humidity
10. Salt Spray
Contact resistance: 250 m ohms max.
Insulation resistance: 1 M ohms min. (High humidity)
Insulation resistance: 10 M ohms min. (Dry state)
500 hours at temperature of 40ç and humidity of 90% to 95%
Contact resistance: 250 m ohms max.
Exposed to density 5% salt water for 48 hours
Note :Includes temperature rise caused by current flow.
■Materials
Part
Material
Finish
Remarks
Insulator
Polycarbonate
Color: Clear
UL94V-2
Contacts
Copper alloy
Contact area: Gold plating
-------
Shield
Conductor holding tray
Copper alloy
Solder plating
-------
Polycarbonate
Color: Clear
UL94V-2
Polyamide
Color: Light beige (Note)
UL94V-2
Cover
Note :Cover available in various colors. Refer to page 3.
■Ordering information
●Plugs- Shielded
●Plugs - Non-shielded
TM21 C P - 8 8P
1
1 Series name
2
2
1
3
TM22P - 8 8P
4
1
2
3
TM21P: Shielded
1 Series name
TM22P : Non-shielded
2 Cover Type
Blank: Protective latch cover
2 Size
8 : For 8 contacts
C: Short cover
3 Inserted contacts
8P: 8
3 Size
8: For 8 contacts
4 Inserted contacts
8P: 8
■Plug Connectors
●Shielded
Cover
(34)
30.2
9
16.6
11.7
6.09
)
3.5
(R
6.7
Conductor holding tray
Contact No. 1
3.45
29.5
(0.6)
6.6
12.9
17.5
Contact No.8
5.4
9.05
CL No.
Cover Color
TM21P-88P
Part Number
222-2862-9-02
Light beige
TM21P-88P(02)
222-2862-9-02
Medium gray
TM21P-88P(03)
222-2862-9-03
Black
TM21P-88P(04)
222-2862-9-04
Natural light gray
TM21P-88P(05)
222-2862-9-05
Red
TM21P-88P(06)
222-2862-9-06
Green
TM21P-88P(07)
222-2862-9-07
Blue
TM21P-88P(08)
222-2862-9-08
Yellow
TM21P-88P(09)
222-2862-9-09
Orange
BCover installed
BMated with corresponding receptacle
(shown for reference only)
(34)
(13.4)
(44.65)
3
■Plug Connectors
●Shielded-Short Cover
6.7
17.2
TM21CP-8
9
3.
5)
TM21CP-8
30.2
10.4
(22.4)
11.7
6.09
Cover
Conductor holding tray
3.45
12.9
(0.6)
6.6
(R
17.5
Contact No.8
Contact No.1
5.4
9.05
Part Number
CL No.
Cover color
TM21CP-88P(03)
222-2884-1-03
Black
Note: For other colors contact Hirose sales representative.
BCover installed
BMated with corresponding receptacle
(shown for reference only)
(21.7)
TM21CP-8
TM21CP-8
(32.35)
(13.4 )
BApplicable Shielded Cable Specifications
Specifications
Solid copper conductor: 0.5mm dia.
Jacket
Conductor
Shield
Stranded copper conductor: AWG#24
(Dia. 0.2mm x 7 pcs)
Insulation
Conductor
Individual conductor insulation dia.
(0.9mm to 1.0mm)
Drain wire
AWG#26 (tin coated)
Overall jacket dia.
(dia. 6.6mm)
Drain wire
Note: For cable termination procedures refer to:
[TM21P-88P Cable Termination Procedure Manual] (ETA-E2349) and [TM21CP-88P Cable termination Procedure Manual]
(ETA-E2353).
Some cables may not meet the required service ratings. Contact Hirose sales representative for specific cable applications
recommendations.
4
■Plug Connectors
●Non-shielded
11.7
Conductor holding tray
6.6
9.05
(0.6)
7.9
14.2
5.4
3.45
6.09
22.5
Contact No.1
Part Number
CL No.
TM22P-88P
222-2899-9
Contact No.8
BMated with corresponding receptacle (shown for reference only)
(11.85)
BApplicable Non-shielded Cable Specifications
Specifications
Solid copper conductor: 0.5mm dia.
Jacket
Conductor
Stranded copper conductor: AWG#24
(Dia. 0.2mm x 7 pcs)
Individual conductor insulation dia.
(0.9mm to 1.0mm)
Overall jacket dia.
(dia. 5.4mm to 5.7mm)
Conductor
Insulation
Note: For cable termination procedures refer to:
[TM22P-88P Cable Termination Procedure Manual] (ETA-E2381).
Some cables may not meet the required service ratings. Contact Hirose sales representative for specific cable applications
recommendations.
5
BHand termination tools
●For contact/conductor termination
Part Number
CL No.
HT205/TM21P-88P
250-0234-4
●For cable and shield crimping (Shielded connectors only)
Part Number
CL No.
HT206/TM21P-88P
250-0235-7
●For contact/conductor termination (Non-shielded connectors)
Part Number
CL No.
HT501/TMP-88
902-2111-9*
*Scheduled for release soon. Please contact your Hirose Electric
account representative for information.
6
BTechnical Documentation
●CAT5e Transmission Characteristics Data
These are the representative values of the various transmission characteristics data for connector assemblies
TM21P-88P and TM21R-5C-88-LP when fully mated.
All plugs in the TM21R-5C Series that were manufactured based on the De-embedded method of the TIA/EIA568-B.2 standard meet requirements of CAT5e single transmission performance.
• Signal Attenuation
Attenuation(dB)
0.5
0.4
0.3
0.2
0.1
0
0
10
20
30
40
50
60
70
80
90
100
Frequency(MHz)
1,2
3,6
4,5
7,8
CAT5e Spec
(Each two numbers are for the pair of individual contact position.)
• Near-End Crosstalk Attenuation (NEXT)
120
NEXT(dB)
100
80
60
40
20
0
0
10
20
30
40
50
60
70
80
90
100
Frequency(MHz)
1,2-3,6
1,2-4,5
1,2-7,8
3,6-4,5
3,6-7,8
4,5-7,8
CAT5e Spec
• Return Loss
Return Loss(dB)
80
60
40
20
0
0
10
20
30
40
50
60
70
80
90
100
Frequency(MHz)
1,2
3,6
4,5
7,8
CAT5e Spec
7
• Far-End Crosstalk Attenuation (FEXT)
120
100
FEXT(dB)
80
60
40
20
0
0
10
20
30
40
50
60
70
80
90
100
Frequency(MHz)
1,2-3,6
3,6-4,5
4,5-7,8
CAT-5e Spec
1,2-4,5
3,6-7,8
7,8-1,2
1,2-7,8
4,5-1,2
7,8-3,6
3,6-1,2
4,5-3,6
7,8-4,5
(Each two numbers are for pair of individual contact position.)
• Propagation Delay
3
Delay(ns)
2.5
2
1.5
1
0.5
0
0
10
20
30
40
50
60
70
80
90
100
Frequency(MHz)
1,2
3,6
4,5
7,8
CAT5e Spec
• Propagation Delay skew
1.4
Delay Skew(ns)
1.2
1
0.8
0.6
0.4
0.2
0
0
10
20
30
40
50
60
70
80
90
100
Frequency(MHz)
8
ks to World El
e
Lin
onics
ctr
Creativ
e
Measurement Value
CAT5e Spec
HIROSE ELECTRIC CO., LTD.
5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN
PHONE:81-3-3491-9741
FAX:81-3-3493-2933
http://www.hirose.com
The contents of this catalog are current as of date of publication. Contents are subject to change without notice for the purpose of improvements.