Model 440 Two-Wire Gage/Absolute Pressure Transmitter DESCRIPTION Two-wire transmitter Model 440 offers rugged, stainless steel Two-wire, 4 mA to 20 mA output is provided. The Model 440 of- construction suitable for even the harshest working environ- fers an accuracy of 0.25 % F.S. DIN-type electrical connector is ments. These models are available with zero and span standard on the Model 440. adjustments located under the removeable electrical connector and operate with a supply voltage from 9 Vdc to 32 Vdc. FEATURES • 5 psig/a to 10000 psig/a range • Two-wire, 4 mA to 20 mA output • 0.25 % accuracy • Intrinsically safe option available • Solderless and water-resistant connection Model 440 PERFORMANCE SPECIFICATIONS Characteristic Measure Pressure ranges 5, 10, 15, 25, 50, 75, 100, 150, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 5000, 7500, 10000 psig/a RANGE CODES Range Code Available ranges Range Code Available ranges AT 5 psig/a CP 300 psig/a AV 10 psig/a CR 500 psig/a Accuracy3 ±0.25 % full scale BJ 15 psig/a CT 750 psig/a Non-linearity and hysteresis ±0.20 % best-fit straight line BL 25 psig/a CV 1000 psig/a Non-repeatability ±0.20 % best-fit straight line BN 50 psig/a DJ 1500 psig/a Output 4 mA to 20 mA BP 75 psig/a DL 2000 psig/a Resolution Infinite BR 100 psig/a DN 3000 psig/a CJ 150 psig/a DR 5000 psig/a CL 200 psig/a DT 7500 psig/a DV 10000 psig/a ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -29 °C to 85 °C [-20 °F to 185 °F] Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F] Temperature effect, zero 0.01 % full scale/°F Temperature effect, span 0.01 % reading/°F OPTION CODES Range Code Pressure ranges 5, 15, 50, 100, 200, 500, 1000, 3000, 5000, 10000 psig 10, 25, 75, 150, 300, 750, 1500, 2000, 7500 psig/a 5, 15, 50, 100, 200, 500, 1000, 3000, 5000, 10000 psia Temperature compensation 1a. 60 °F to 160 °F Internal amplifiers 2k. 4 mA to 20 mA (2 wire) output 2n. (2N) 4 mA to 20 mA (2 wire) intrinsically safe Pressure ports 5a. 1/4-18 NPT female Electrical termination 6m. DIN 43650 Special calibration2 9a. 10 point (5 up/5 down) 20 % increments @ 70 °F 9b. 20 point (10 up/10 down) 10 % increments @ 70 °F ELECTRICAL SPECIFICATIONS Characteristic Measure Excitation (calibration) 24 Vdc Excitation (acceptable) 9 Vdc to 32 Vdc Insulation resistance 5000 mOhm @ 50 Vdc Electrical termination (std) DIN 43650 water resistant Mating connector (not incl) DIN mating connector with solderless terminal1 Zero and span adjustments Located under top cover Frequency response 2000 Hz 1 MECHANICAL SPECIFICATIONS Characteristic Measure Media Gas, liquid Overload, safe 50 % over capacity Overload, burst 200 % over capacity Pressure port 1/4-18 NPT female Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. Wetted parts material <300 psig/a HA C276/316 stainless steel 300 psig/a to 1500 psig/a 17-4 PH stainless steel >1500 psig/a 15-5 PH stainless steel Weight 13 oz Case material Stainless steel 2 Honeywell • Sensing and Control Special requirements (consult factory) Have a special requirement? New case pressure, different cable lengths, electrical connectors, or materials? Consult our factory by calling +1 614-850-5000 (800-848-6564). Customization is key to our test and measurement business. Special outputs, wiring codes, and calibrations are all standard to us. Two-Wire Gage/Absolute Pressure Transmitter RANGE CODES Pressure range 5 10 15 25 50 75 100 150 200 300 500 750 1000 1500 2000 3000 5000 7500 10000 RANGE CODE AT AV BJ BL BN BP BR CJ CL CP CR CT CV DJ DL DN DR DT DV D mm [in] 38 [1.50] L mm [in] 66 [2.6] Over pressure (test) (psi) 150 % full scale Over pressure (burst) (psi) 20 Port volume cm3 [in3] 3,1 [0.12] Natural frequency (Hz) 1K 40 1.3 K 84 [3.3] 60 100 200 300 400 600 800 2.1 K 2.5 K 2.9 K 3.5 K 4.6 K 6K 7K 2000 9K 9.5 K 76 [3.0] 3000 3500 4000 8000 12000 20000 25000 25000 12 K 17 K 20 K 35 K 40 K 54 K 60 K 80 K INTERNAL AMPLIFIERS Amplifier specifications Current two-wire: Option 2k4 Intrinsically safe amp: Option 2n (2N)* Output signal 4 mA to 20 mA 4 mA to 20 mA Input power (voltage) 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc Input power (current) 4 mA to 24 mA 4 mA to 24 mA Frequency response 300 Hz 2000 Hz Power supply rejection 60 db 60 db Operating temperature -29 °C to 85 °C [-20 °F to 185 °F] -29 °C to 85 °C [-20 °F to 185 °F] Reverse voltage protection Yes Yes Short circuit protection Yes Wiring code: connector (std) 1 2 3 GND Yes (+) Supply (+) Output No connection Case ground 1 2 3 GND (+) Supply (+) Output No connection Case ground * See Honeywell’s Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00. Honeywell • Sensing and Control 3 Model 440 Two-Wire Gage/Absolute Pressure Transmitter Mounting dimensions and characteristics For reference only TYPICAL SYSTEM DIAGRAM Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to [email protected] WARNING PERSONAL INJURY NOTES 1. Specify cable diameter: can handle diameter of 4,5 mm to 14 mm or 1/2 in NPT conduit fitting. 2. Availability varies with range. 3. Accuracies stated are expected for best-fit straight line for all errors including linearity, hysteresis & non-repeatability thru zero. 4. Max. load resistance is 500 ohm @ 23 Vdc. •DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION •The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. •Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008683-1-EN IL50 GLO May 2008 Copyright © 2008 Honeywell International Inc. All rights reserved.