Model 440 - Honeywell Test and Measurement Sensors

Model 440
Two-Wire Gage/Absolute
Pressure Transmitter
DESCRIPTION
Two-wire transmitter Model 440 offers rugged, stainless steel
Two-wire, 4 mA to 20 mA output is provided. The Model 440 of-
construction suitable for even the harshest working environ-
fers an accuracy of 0.25 % F.S. DIN-type electrical connector is
ments. These models are available with zero and span
standard on the Model 440.
adjustments located under the removeable electrical connector
and operate with a supply voltage from 9 Vdc to 32 Vdc.
FEATURES
•
5 psig/a to 10000 psig/a range
•
Two-wire, 4 mA to 20 mA output
•
0.25 % accuracy
•
Intrinsically safe option available
•
Solderless and water-resistant connection
Model 440
PERFORMANCE SPECIFICATIONS
Characteristic
Measure
Pressure ranges
5, 10, 15, 25, 50, 75, 100, 150, 200, 300,
500, 750, 1000, 1500, 2000, 3000, 5000,
7500, 10000 psig/a
RANGE CODES
Range
Code
Available ranges Range
Code
Available ranges
AT
5 psig/a
CP
300 psig/a
AV
10 psig/a
CR
500 psig/a
Accuracy3
±0.25 % full scale
BJ
15 psig/a
CT
750 psig/a
Non-linearity and hysteresis
±0.20 % best-fit straight line
BL
25 psig/a
CV
1000 psig/a
Non-repeatability
±0.20 % best-fit straight line
BN
50 psig/a
DJ
1500 psig/a
Output
4 mA to 20 mA
BP
75 psig/a
DL
2000 psig/a
Resolution
Infinite
BR
100 psig/a
DN
3000 psig/a
CJ
150 psig/a
DR
5000 psig/a
CL
200 psig/a
DT
7500 psig/a
DV
10000 psig/a
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Measure
Temperature, operating
-29 °C to 85 °C [-20 °F to 185 °F]
Temperature, compensated
-1 °C to 54 °C [30 °F to 130 °F]
Temperature effect, zero
0.01 % full scale/°F
Temperature effect, span
0.01 % reading/°F
OPTION CODES
Range Code
Pressure ranges
5, 15, 50, 100, 200, 500, 1000, 3000, 5000,
10000 psig
10, 25, 75, 150, 300, 750, 1500, 2000,
7500 psig/a
5, 15, 50, 100, 200, 500, 1000, 3000, 5000,
10000 psia
Temperature
compensation
1a. 60 °F to 160 °F
Internal
amplifiers
2k. 4 mA to 20 mA (2 wire) output
2n. (2N) 4 mA to 20 mA (2 wire) intrinsically
safe
Pressure ports
5a. 1/4-18 NPT female
Electrical
termination
6m. DIN 43650
Special
calibration2
9a. 10 point (5 up/5 down)
20 % increments @ 70 °F
9b. 20 point (10 up/10 down)
10 % increments @ 70 °F
ELECTRICAL SPECIFICATIONS
Characteristic
Measure
Excitation (calibration)
24 Vdc
Excitation (acceptable)
9 Vdc to 32 Vdc
Insulation resistance
5000 mOhm @ 50 Vdc
Electrical termination (std)
DIN 43650 water resistant
Mating connector (not incl)
DIN mating connector with solderless
terminal1
Zero and span adjustments
Located under top cover
Frequency response
2000 Hz
1
MECHANICAL SPECIFICATIONS
Characteristic
Measure
Media
Gas, liquid
Overload, safe
50 % over capacity
Overload, burst
200 % over capacity
Pressure port
1/4-18 NPT female
Many range/option combinations are available in
our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Wetted parts material
<300 psig/a
HA C276/316 stainless steel
300 psig/a to
1500 psig/a
17-4 PH stainless steel
>1500 psig/a
15-5 PH stainless steel
Weight
13 oz
Case material
Stainless steel
2 Honeywell • Sensing and Control
Special requirements (consult factory)
Have a special requirement? New case pressure, different cable lengths,
electrical connectors, or materials? Consult our factory by calling +1
614-850-5000 (800-848-6564). Customization is key to our test and
measurement business. Special outputs, wiring codes, and calibrations
are all standard to us.
Two-Wire Gage/Absolute Pressure Transmitter
RANGE CODES
Pressure range
5
10
15
25
50
75
100
150
200
300
500
750
1000
1500
2000
3000
5000
7500
10000
RANGE CODE
AT
AV
BJ
BL
BN
BP
BR
CJ
CL
CP
CR
CT
CV
DJ
DL
DN
DR
DT
DV
D mm [in]
38 [1.50]
L mm [in]
66 [2.6]
Over pressure
(test) (psi)
150 % full scale
Over pressure
(burst) (psi)
20
Port volume
cm3 [in3]
3,1 [0.12]
Natural
frequency (Hz)
1K
40
1.3
K
84 [3.3]
60
100
200
300
400
600
800
2.1
K
2.5
K
2.9
K
3.5
K
4.6
K
6K
7K
2000
9K
9.5
K
76 [3.0]
3000
3500
4000
8000
12000
20000
25000
25000
12 K
17 K
20 K
35 K
40 K
54 K
60 K
80 K
INTERNAL AMPLIFIERS
Amplifier specifications
Current two-wire: Option 2k4
Intrinsically safe amp: Option 2n (2N)*
Output signal
4 mA to 20 mA
4 mA to 20 mA
Input power (voltage)
9 Vdc to 32 Vdc
9 Vdc to 28 Vdc
Input power (current)
4 mA to 24 mA
4 mA to 24 mA
Frequency response
300 Hz
2000 Hz
Power supply rejection
60 db
60 db
Operating temperature
-29 °C to 85 °C [-20 °F to 185 °F]
-29 °C to 85 °C [-20 °F to 185 °F]
Reverse voltage protection
Yes
Yes
Short circuit protection
Yes
Wiring code: connector (std)
1
2
3
GND
Yes
(+) Supply
(+) Output
No connection
Case ground
1
2
3
GND
(+) Supply
(+) Output
No connection
Case ground
* See Honeywell’s Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.
Honeywell • Sensing and Control 3
Model 440
Two-Wire Gage/Absolute Pressure Transmitter
Mounting dimensions and characteristics
For reference only
TYPICAL SYSTEM DIAGRAM
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit
www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to [email protected]
WARNING
PERSONAL INJURY
NOTES
1. Specify cable diameter: can handle diameter of 4,5 mm to 14 mm or
1/2 in NPT conduit fitting.
2. Availability varies with range.
3. Accuracies stated are expected for best-fit straight line for all errors
including linearity, hysteresis & non-repeatability thru zero.
4. Max. load resistance is 500 ohm @ 23 Vdc.
•DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
•Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008683-1-EN IL50 GLO May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.