M100A THRU M100M GENERAL PURPOSE PLASTIC RECTIFIER Reverse Voltage - 50 to 1000 Volts Forward Current - 1.0 Ampere FEATURES DO-204AL ♦ Plastic package has Underwriters Laboratory Flammability Classification 94V-0 ♦ Construction utilizes void-free molded plastic technique ♦ Low reverse leakage ♦ High surge current capability ♦ High temperature soldering guaranteed: 250°C/10 seconds, 0.375" (9.5mm) lead length, 5 lbs. (2.3kg) tension 1.0 (25.4) MIN. 0.107 (2.7) 0.080 (2.0) DIA. 0.205 (5.2) 0.160 (4.1) MECHANICAL DATA Case: JEDEC DO-204AL, molded plastic body Terminals: Plated axial leads, solderable per MIL-STD-750, Method 2026 Polarity: Color band denotes cathode end Mounting Position: Any Weight: 0.012 ounce, 0.3 gram 1.0 (25.4) MIN. 0.034 (0.86) 0.028 (0.71) DIA. Dimensions in inches and (millimeters) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25°C ambient temperature unless otherwise specified. SYMBOLS M100 A M100 B M100 D M100 G M100 J M100 K M100 M UNITS Maximum repetitive peak reverse voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS voltage VRMS 35 70 140 280 420 560 700 Volts Maximum DC blocking voltage VDC 50 100 200 400 600 800 1000 Volts Maximum average forward rectified current 0.375" (9.5mm) lead length at T A=100°C I(AV) 1.0 Amp Peak forward surge current 8.3ms single half sine-wave superimposed on rated load (JEDEC Method) at TA=75°C IFSM 50.0 Amps VF 1.0 IR(AV) 100.0 µA IR 1.0 50.0 µA Typical reverse recovery time (NOTE 1) trr 2.0 µs Typical junction capacitance (NOTE 2) CJ 15.0 pF RΘJA RΘJL 50.0 25.0 °C/W TJ, TSTG -50 to +150 °C Maximum instantaneous forward voltage at 1.0A Maximum full load reverse current full cycle average 0.375" (9.5mm) lead length at TA=55°C Maximum DC reverse current at rated DC blocking voltage TA=25°C TA=100°C Typical thermal resistance (NOTE 3) Operating junction and storage temperature range NOTES: (1) Measured with IF=0.5A, IR=0.1A, Irr=0.25A (2) Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts (3) Thermal resistance from junction to ambient and from junction to lead at 0.375" (9.5mm) lead length, P.C.B. mounted 4/98 1.1 Volts RATINGS AND CHARACTERISTIC CURVES M100A THRU M100M FIG. 2 - MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT FIG. 1 - FORWARD CURRENT DERATING CURVE 50 60 HZ RESISTIVE OR INDUCTIVE LOAD PEAK FORWARD SURGE CURRENT, AMPERES AVERAGE FORWARD RECTIFIED CURRENT, AMPERES 1.2 1.0 0.2 x 0.2” (5.0 x 5.0mm) COPPER PADS 0.8 0.375” (9.5mm) LEAD LENGTH 0.6 0.4 8.3ms SINGLE HALF SINE WAVE (JEDEC Method) TA = 75°C 40 30 20 10 0.2 0 0 25 50 75 100 125 NUMBER OF CYCLES AT 60 HZ 175 150 100 10 1 AMBIENT TEMPERATURE, °C FIG. 4 - TYPICAL REVERSE CHARACTERISTICS FIG. 3 - TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS 1,000 INSTANTANEOUS REVERSE CURRENT, µA INSTANTANEOUS FORWARD CURRENT, AMPERES 100 10 1 0.1 TJ=25°C PULSE WIDTH=300µs 1% DUTY CYCLE 0.01 0.6 0.8 1.0 1.2 1.4 1.6 100 10 1 0.1 TJ=25°C 0.01 1.8 FIG. 5 - TYPICAL JUNCTION CAPACITANCE 20 40 60 80 100 FIG. 6 - TYPICAL TRANSIENT THERMAL IMPEDANCE TJ=25°C f=1.0 MHz Vsig=50mVp-p 10 1 10 REVERSE VOLTAGE, VOLTS 100 TRANSIENT THERMAL IMPEDANCE, °C/W 100 100 JUNCTION CAPACITANCE, pF 0 PERCENTAGE OF PEAK REVERSE VOLTAGE, % INSTANTANEOUS FORWARD VOLTAGE, VOLTS 1 0.1 TJ=150°C 10 1 0.1 0.01 0.1 1 t, PULSE DURATION, sec. 10 100