TOSHIBA S

S-AV10L,S-AV10H
TOSHIBA RF Power Amplifier Module
S-AV10L,S-AV10H
VHF RF Power Amplifier Module
Unit: mm
·
High gain: Po ≥ 14 W, Gp ≥ 1.85dB, ηT ≥ 40%
·
S-AV10L 135~155 MHz
·
S-AV10H 150~175 MHz
Maximum Ratings (Tc = 25°C)
Characteristics
Symbol
Rating
Unit
DC supply voltage
VCC
16
V
DC supply voltage
VCON
16
V
Pi
300
mW
Tc (opr)
-30~100
°C
Tstg
-40~110
°C
Input power
Operating case temperature range
Storage temperature range
JEDEC
―
JEITA
―
TOSHIBA
Weight: 35 g (typ.)
Electrical Characteristics (Tc = 25°C)
Characteristics
Frequency range
Symbol
Test Condition
Min
Typ.
Max
Unit
frange
¾
135
¾
175
MHz
14
¾
¾
W
18.5
¾
¾
dB
VCC = 12.5 V, VCON = 12.5 V
40
¾
¾
%
ZG = ZL = 50 W
¾
¾
2
¾
¾
¾
-25
dB
Output power
Po
Power gain
GP
Total efficiency
hT
Input VSWR
Harmonics
5-53P
VSWRin
Pi = 200 mW
HRM
VCC = 15 V, VCON = 12.5 V
Load mismatch
¾
Po = 15 W (Pi = adjust)
¾
No degradation
VSWR load 20: 1 all phase
Tc = -30~80°C
Power slump
¾
VCC = 12.5 V, Pi = 200 mW
¾
0.8
¾
dB
Po = 14 W (@Tc = 25°C)
VCC = 12.5 V, Pi = 200 mW
Stability
¾
VCON = 0~12.5 V
VSWR Load 3: 1 all phase
1
All spurious output than
60dB below desired
signal
¾
2003-03-27
S-AV10L,S-AV10H
Caution
This product has intersetting cap. Please pay attention for exceeding stress and foreign matter in your
application. And not to take away the cap.
Beryllia Ceramics is used in this product. The dust or vapor can be dangerous to humans. Do not break, cut,
crush or dissolve chemically. Dispose of this product properly according to law. Do not intermingle with normal
industrial or domestic waste.
Schematic
Test Fixture
C1, C3: 15000 pF
C2, C4: 10 mF
L1, L2: f0.8 enamel wire, 8 T, 5ID
2
2003-03-27
S-AV10L,S-AV10H
Caution
These are only typical curves and devices are not necessarily guaranteed at these curves.
3
2003-03-27
S-AV10L,S-AV10H
RESTRICTIONS ON PRODUCT USE
000707EAA
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
4
2003-03-27