File name: TFH70D.doc Version 1.0 VI TELEFILTER Filter Specification 09.03.2001 TFH 70D 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances at fc: Q-value of matching elements: 23 °C 0 dBm. for input: for output: > 50 1088 Ω - 7,20 pF. 932 Ω - 7,92 pF. 2. Characteristics : Remark: The insertion loss ae is defined as the insertion loss at the nominal frequency fN . Reference level for the relative attenuation arel of the TFH 70D is the insertion loss. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the centre frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. Data Insertion loss (Reference level) ae Nominal frequency fN Centre frequency fc at ambient temperature TA (fCAT) typ. value tolerance / limit 26 dB max. 70,01 MHz 70 70,0 ± 0,09 MHz MHz fN .... fN ± 1,5 MHz Pass band at ambient temperature TA: ( PB ) Amplitude ripple in O.T.R. (p-p) in : fN ... fN ± 1,4 MHz 27 dB 0,5 dB max. 0,8 dB 3,19 3,22 3,61 4,66 5,21 5,31 MHz MHz MHz MHz MHz MHz min. min. min. 2,8 3,0 3,5 MHz MHz MHz max. 5,6 MHz 0,5 0,7 2,5 dB dB dB max. max. max. 0,8 1 3 dB dB dB dB dB dB dB dB min. min. 40 50 dB dB max. max. 100 6 ns ° Bandwidth in O.T.R. : 0,8 1 3 20 40 45 dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width Relative attenuation fN ± fN ± arel fN ..... fN ± 1,4 MHz 1,4 MHz ... fN ± 1,5 MHz 1,5 MHz ... fN ± 1,75 MHz fN ± 2,8 fN ± 5,0 fN - 65 fN + 35 fN + 63 MHz ... fN ± MHz ... fN ± MHz ... fN MHz ... fN + MHz ... fN + 5,0 20 20 63 200 MHz MHz MHz MHz MHz Group delay ( mean value in PB ): Group delay ripple in PB (p-p): Deviation from linear phase in PB band (p-p): (S11) / (S22) in PB : Triple transit attenuation compared to main signal Crosstalk Frequency inversion temperature ( To ) Temperature coefficient of frequency ( Tcf ) Frequency deviation of fC over temperature: * ) 44...53 53...65 75...65 42...45 65...70 2,76 µs 45 ns 2,6° (r.m.s. 0,6°) 3/3 59 52 dB dB dB 30 °C -0,045 ppm/K² ∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz) Operating temperature range ( O.T.R. ) Storage temperature range 0 °C ... + 70 °C -40 °C ... + 85 °C * ) fTo is reference frequency fc at frequency inversion temperature (To ) Generated: Dunzow W.P. Checked/Approved: Dr. Bert Wall VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFH70D.doc Version 1.0 VI TELEFILTER Filter Specification TFH 70D 09.03.2001 2/5 3. Package : 24.64 TFH 70D N07 Datecode: Year+week L 1999 M 2000 N 2001 9.00 2.62 Max 1.02 1 2 3 4 5 7 6 Pin 10 Pin 1 Pin 5 Pin 6 Pin 2-4, 7-9 11 10 9 8 1.91 4.83 x 3.53 Input Input RF Return Output Output RF Return Package Ground 2.31 1.02 4. 50 Ω matching network : ( see Application Note of TFH 70D ) Scheme 1 1 2 3 4 5 L2 50 Ω L1 10 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] 9 8 7 50 Ω 6 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFH70D.doc Version 1.0 VI TELEFILTER Filter Specification 09.03.2001 TFH 70D 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing : Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 1000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE D Tape (all dimensions in mm) W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 44 ± 0,3 4 ± 0,1 1,5 + 0,1 1,75 ± 0,1 20,25 ± 0,05 0,75 2 ± 0,05 16 ± 0,1 2,0 9,3 ± 0,1 24,9 ± 0,1 38 ± 0,2 P 0 0 P 2 E A o F D 1 CT W B o G P 1 COVER TAPE W2 Reel (all dimensions in mm): A W1 W2 (max) N (min) C : : : : : 330 46 50 100 13 ± 0,2 C A N W1 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFH70D.doc Version 1.0 VI TELEFILTER Filter Specification 09.03.2001 TFH 70D 4/5 7. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. File name: TFH70D.doc VI TELEFILTER Version 1.0 Filter Specification 09.03.2001 TFH 70D 5/5 8. History : Version Reason of changes Name Date 1.0 Generate extended filter specification. Dunzow W. 09.03.2001 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: [email protected] Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.