VECTRON TFS195

Tfs195.doc
version 1.2
11.09.2000
______________________________________________________________________________________________________
VI
TELEFILTER
SAW Filter Specification
TFS 195
1/5
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
23 °C
Input power level:
0 dBm
Terminating impedances
for input:
1150 Ohm // -1.7 pF
for output:
1150 Ohm // -1.7 pF
Coupling coil:
197 nH
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 195 is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The nominal frequency fN is fixed on 195,6 MHz without tolerance. The specified values have to be reached in
operating temperature range.
Data
typ. value
Insertion loss
(Reference level)
ae
-
Nominal frequency
fN
-
Centre frequency
fC
tolerance/limit
2.3...4.3
195,600 MHz
195,608 MHz
-
BW
212
-
Relative attenuation
arel
fN ± 1,8 MHz ... fN ± 6
MHz
fN ± 6 MHz ... fN ± 100 MHz
42
23...90
1 dB bandwidth
VSWR
@ fC
Group delay
@ fC
dB
kHz
dB
dB
1.4:1
min.
min.
30
20
min.
1.8 : 1
dB
dB
GD
3,2
Input power
µs
-
max.
6
max.
10
µs
dBm
Operating temperature range
- 5 °C ... + 80 °C
Storage temperature range
- 30 °C ... + 80 °C
Temperature coefficient of frequency
Frequency inversion temperature
TC
- 0.036
ppm/K²
20
°C
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs195.doc
version 1.2
11.09.2000
______________________________________________________________________________________________________
VI
TELEFILTER
SAW Filter Specification
TFS 195
2/5
______________________________________________________________________________________________________
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
Datecode:
K
L
M
...
TFS195
M36
1
2
3
4
5
6
7
8
9
10
11
12
Year+week
1998
1999
2000
Output
Output RF-Return
Ground
Coupling Coil
Ground
Ground
Input
Input RF-Return
Ground
Ground
Ground
Ground
50 Ohm Test circuit
50 Ohm
L1
7
L2
1
C1
8
SAW
50 Ohm
C2
2
L3
3, 5, 6, 9, 10, 11, 12
4
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs195.doc
version 1.2
11.09.2000
______________________________________________________________________________________________________
VI
TELEFILTER
SAW Filter Specification
TFS 195
3/5
______________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
Do
E
F
:
:
:
:
:
0,6
2
8
1,5
5,5
7,5
Ct
13,5 ± 0,1
:
EMBOSSED CARRIER TAPE
16
± 0,3
4
± 0,1
1,5 + 0,1
1,75 ± 0,1
7,5 ± 0,1
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
Bo
:
3000
min 300 mm
min 500 mm
min 300 mm
Do
Po
P2
E
Ao
F
D1
Ct
W
Bo
± 0,1
± 0,1
G
± 0,1
± 0,1
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
50
C
C
:
A
13,0 +0,5/-0,2
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs195.doc
version 1.2
11.09.2000
______________________________________________________________________________________________________
VI
TELEFILTER
SAW Filter Specification
TFS 195
4/5
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs195.doc
version 1.2
11.09.2000
______________________________________________________________________________________________________
VI
TELEFILTER
SAW Filter Specification
TFS 195
5/5
______________________________________________________________________________________________________
History
Version
Reason of Changes
Name
Date
1.0
- generated according to customer requirement
Dr. Sabah
27.06.2000
1.1
- remove pass band width related values
- change position of input and output pin
- add coupling coil
Dr. Wall
25.07.2000
1.2
- add termination impedances and coupling coil value
- define insertion loss window
- add 50 Ohm test circuit
- add typical values for filter data
- add maximum value for group delay
- correct tape and reel information
Dr. Wall
06.09.2000
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.