tfs309.doc version 1.5 VI TELEFILTER Filter Specification 13.07.2000 TFS 309 1/5 Measurement condition Ambient temperature: 23 Input power level: 0 Terminating impedances for input: for output: External coil: °C dBm 540 Ohm // -1,7 pF 540 Ohm // -1,7 pF 116 nH Characteristics Remark: Reference level for the relative attenuation arel of the TFS 309 is the insertion loss. The insertion loss ae is defined as the insertion loss at the nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 309,6 MHz without tolerance. The specified values have to be reached in operating temperature range. Data typ.value tolerance/limit Insertion loss (Reference level) ae 2,75 Nominal frequency fN - Centre frequency fC 309,62 MHz - 1 dB bandwidth BW 270 kHz - Relative attenuation arel fN ± 1,8 MHz ... fN ± 6 MHz fN ± 6 MHz ... fN ± 100 MHz 47 28...65 VSWR @ fN Group delay @ fN 2,1 ... 4,1 dB dB 309,600 MHz dB dB min. min. 1,2:1 30 20 min. 1,8 : 1 max. 4,6 dB dB GD 2,6 Input power µs - max. Frequency inversion temperature dBm - 5 °C ... + 80 °C Operating temperature range Temperature coefficient of frequency 10 µs TC ca. – 0,036 ppm/K² + 25 °C Generated: Checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs309.doc version 1.5 VI TELEFILTER Filter Specification TFS 309 13.07.2000 2/5 Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) 5.0 SQ 7 +0.15 -0.1 5 S 309 M24 1 3 Date code Pin 1 Pin 2,6,7 Pin 3 Pin 4,8 Pin 5 Output Ground External Coil Package Ground Input Datecode: K L M ... Year+week 1998 1999 2000 50 Ohm Test circuit 1 L1 5 C1 L2 1 SAW C2 3 2, 4, 6, 7, 8 L3 50 Ohm Test circuit 2 C1 C2 5 L1 1 SAW L2 3 2, 4,6,7,8 L3 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs309.doc version 1.5 VI TELEFILTER Filter Specification 13.07.2000 TFS 309 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer Tape (all dimensions in mm) W Po : : 12 4 Do 1,5 + 0,1 1,75 ± 0,1 5,5 ± 0,05 0,75 2 ± 0,05 8 ± 0,1 1,5 5,3 ± 0,1 Bo CT 5,3 9,5 : : EMBOSSED CARRIER TAPE ± 0,3 ± 0,1 Do : E : F : G (min) : P2 : P1 : D1(min) : Ao : 3000 min 300 mm min 500 mm min 300 mm Po P2 E Ao F D1 CT W Bo G P1 ± 0,1 ± 0,1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 12,4 + 0,2 18,4 50 C C : 13 ± 0,2 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs309.doc version 1.5 VI TELEFILTER Filter Specification 13.07.2000 TFS 309 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. tfs309.doc version 1.5 VI TELEFILTER Filter Specification 13.07.2000 TFS 309 5/5 History Version Reason of Changes Name Date 1.2 Add preliminary values for termination impedance Add history Modify monthly date code into weekly date code Dr. Wall 09.05.2000 1.3 Correct tape and reel information Add limit values for package dimensions Add final termination conditions Add typical filter data Add limits for insertion loss Dr. Wall 15.06.2000 1.4 Add maximum input power Add reletive attenuation value for FN ± 6 MHz ... FN ± 100 MHz Add group delay Notice 1 dB bandwidth instead of 3 dB bandwidth Increase window for insertion loss to two dB Dr. Wall 28.06.2000 1.5 Maximum input power changed to 10 dBm Dr. Wall 13.07.2000 VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.