VECTRON TFS309

tfs309.doc
version 1.5
VI TELEFILTER
Filter Specification
13.07.2000
TFS 309
1/5
Measurement condition
Ambient temperature:
23
Input power level:
0
Terminating impedances
for input:
for output:
External coil:
°C
dBm
540 Ohm // -1,7 pF
540 Ohm // -1,7 pF
116 nH
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 309 is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The nominal frequency fN is fixed on 309,6 MHz without tolerance. The specified values have to be reached in
operating temperature range.
Data
typ.value
tolerance/limit
Insertion loss
(Reference level)
ae
2,75
Nominal frequency
fN
-
Centre frequency
fC
309,62
MHz
-
1 dB bandwidth
BW
270
kHz
-
Relative attenuation
arel
fN ± 1,8 MHz ... fN ± 6 MHz
fN ± 6 MHz ... fN ± 100 MHz
47
28...65
VSWR
@ fN
Group delay
@ fN
2,1 ... 4,1 dB
dB
309,600 MHz
dB
dB
min.
min.
1,2:1
30
20
min.
1,8 : 1
max.
4,6
dB
dB
GD
2,6
Input power
µs
-
max.
Frequency inversion temperature
dBm
- 5 °C ... + 80 °C
Operating temperature range
Temperature coefficient of frequency
10
µs
TC
ca. – 0,036
ppm/K²
+ 25 °C
Generated:
Checked / approved:
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs309.doc
version 1.5
VI TELEFILTER
Filter Specification
TFS 309
13.07.2000
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
5.0 SQ
7
+0.15
-0.1
5
S 309
M24
1
3
Date code
Pin 1
Pin 2,6,7
Pin 3
Pin 4,8
Pin 5
Output
Ground
External Coil
Package Ground
Input
Datecode:
K
L
M
...
Year+week
1998
1999
2000
50 Ohm Test circuit 1
L1
5
C1
L2
1
SAW
C2
3
2, 4, 6, 7, 8
L3
50 Ohm Test circuit 2
C1
C2
5
L1
1
SAW
L2
3
2, 4,6,7,8
L3
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs309.doc
version 1.5
VI TELEFILTER
Filter Specification
13.07.2000
TFS 309
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
:
:
12
4
Do
1,5 + 0,1
1,75 ± 0,1
5,5 ± 0,05
0,75
2 ± 0,05
8
± 0,1
1,5
5,3 ± 0,1
Bo
CT
5,3
9,5
:
:
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
Do
:
E
:
F
:
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
3000
min 300 mm
min 500 mm
min 300 mm
Po
P2
E
Ao
F
D1
CT
W
Bo
G
P1
± 0,1
± 0,1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
12,4 + 0,2
18,4
50
C
C
:
13
± 0,2
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs309.doc
version 1.5
VI TELEFILTER
Filter Specification
13.07.2000
TFS 309
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs309.doc
version 1.5
VI TELEFILTER
Filter Specification
13.07.2000
TFS 309
5/5
History
Version
Reason of Changes
Name
Date
1.2
Add preliminary values for termination impedance
Add history
Modify monthly date code into weekly date code
Dr. Wall
09.05.2000
1.3
Correct tape and reel information
Add limit values for package dimensions
Add final termination conditions
Add typical filter data
Add limits for insertion loss
Dr. Wall
15.06.2000
1.4
Add maximum input power
Add reletive attenuation value for FN ± 6 MHz ... FN ± 100 MHz
Add group delay
Notice 1 dB bandwidth instead of 3 dB bandwidth
Increase window for insertion loss to two dB
Dr. Wall
28.06.2000
1.5
Maximum input power changed to 10 dBm
Dr. Wall
13.07.2000
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.