VECTRON TFS125B

tfs125B.doc
Version 1.0
VI TELEFILTER
Filter Specification
06.03.01
TFS 125 B
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances:
23
0
50
°C
dBm
Ω
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 125 B is the minimum attenuation in the pass band. The minimum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 125 MHz without tolerance or limit. The values of relative attenuation
arel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the
production tolerance scheme.
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________
Insertion loss
1,5...... 3,5 dB
ae
(Reference level)
______________________________________________________________________________________________________
Nominal frequency
125,0 MHz
fN
______________________________________________________________________________________________________
1 dB bandwidth
min. 300,0 kHz
BW
______________________________________________________________________________________________________
Relative attenuation
arel
fN ..... fN ± 150 KHz
max.
1,0 dB
MHz
min. 12,0 dB
fN –124,0 MHz ... fN - 28
MHz
min.
5,0 dB
fN – 28,0 MHz ... fN - 14
min. 30,0 dB
fN + 13,5 MHz ... fN +14,5 MHz
min. 15,0 dB
fN + 14,5 MHz ... fN +28,0 MHz
MHz ... fN +325,0 MHz
min. 38,0 dB
fN + 28
______________________________________________________________________________________________________
VSWR
within ± 150 KHz
max
2,0 : 1
______________________________________________________________________________________________________
Absolute group delay
GD
max. 300,0 ns
Group delay ripple
GDD *)
within ± 150 KHz
max. 30,0 ns
______________________________________________________________________________________________________
Intermodulation
**) IP3
54
dB
min. 45,0 dB
______________________________________________________________________________________________________
Input power level
max. 10,0 dBm
______________________________________________________________________________________________________
Temperature coefficient of frequency
- 71,6
ppm/K
TCf ***)
Operating temperature range
- 10 °C ... + 85 °C
______________________________________________________________________________________________________
*) measured with smoothing; smoothing aperture ≤ 50 kHz
**) modulation signals: fN and fN + 14 MHz, each of 10 dBm; measured signal:
***) ∆f(Hz) = TCf(ppm/K) x (∆T) x fTo(MHz)
fN - 14 MHz
generated:
checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125B.doc
Version 1.0
VI TELEFILTER
Filter Specification
06.03.01
TFS 125 B
2/5
Construction and pin connection
(All dimensions in mm)
TFS 125 B
N09
Date code
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Input
Date code: Year+week
L
1999
M
2000
N
2001
...
Recommended land dimensions
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125B.doc
Version 1.0
VI TELEFILTER
06.03.01
Filter Specification
TFS 125 B
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
Po
:
:
16
4
Do
E
:
:
1,5 + 0,1
1,75 ± 0,1
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
F
:
G (min) :
7,5 ± 0,1
0,60
P2
:
P1
:
D1(min) :
2 ± 0,1
8 ± 0,1
1,5
Ao
Bo
:
:
5,30 ± 0,2
9,70 ± 0,2
CT
:
13,5
3000
min 300 mm
min 500 mm
min 300 mm
Do
Po
P2
E
Ao
F
D1
W
Bo
CT
G
P1
± 0,1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,40 +2,0
22,4
50
C
C
:
13,0
A
± 0,5/-0.2
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125B.doc
Version 1.0
VI TELEFILTER
06.03.01
Filter Specification
TFS 125 B
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs125B.doc
Version 1.0
VI TELEFILTER
Filter Specification
06.03.01
TFS 125 B
5/5
History
Version
Reason of Changes
Name
Date
1.0
- generated specification according to customer requirement specification
Steiner
06.03.2001
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.