Tfs133A.doc Version 1.2 VI TELEFILTER Filter specification 06.03.2003 TFS 133A 1/5 1. Measurement condition : Ambient temperature TA: Input power level: Terminating impedances at fc * ) : 25 °C 0 dBm. for input: for output: t.b.m. t.b.m. t.b.m. pF. t.b.m. pF. 2. Characteristics : Remark: The reference level for the relative attenuation a rel of TFS 133A is the minimum of the pass band attenuation a min. This minimum is defined as the insertion loss a e. The nominal frequency fN is fixed at 133 MHz without any tolerance. . The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The given values for the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below, even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level ) ae = amin 5...6 dB *** ) Nominal frequency Centre frequency at TA = 23°C : Centre frequency at TA = 37°C : fN fCTA fc 133,04 133,00 MHz MHz Pass band PB - Amplitude ripple within PB ( p-p ) 0,2 limit / tolerance max. 7 ***) dB 133 fN ± MHz 0,2 MHz 0,4 dB dB max. min. 630 kHz max.3370 kHz max. dB Bandwidth at ambient temperature TA = 23°C : 0,4 1 3 5 10 20 dB dB dB dB 850...950 1220...1290 1810...1840 2190 kHz kHz kHz kHz dB dB 2680 3250 kHz kHz Relative attenuation fN fN ± fN fN fN fN ± 1,8 ± 6 - 132 + 39 MHz ... MHz ... MHz ... MHz ... arel 0,2 MHz fN ± 6 fN ± 39 fN 39 fN + 887 Return loss in PB : - MHz MHz MHz MHz S11 / S22 0,4 24...28 37...45 60 60...70 dB dB dB dB min. min. min. min. 20 35 20 20 dB dB dB dB 12...15 dB min. 10 dB 0,630 µs max. 1 µs ns max. 100 ns - max. dBm Group delay mean value within fN 50 kHz Group delay variation within fN 50 kHz 20 Temperature coefficient of frequency TCf ** ) - 20 Input power lewel ppm / K 10 - Operating temperature range - - 5 ... + 80 °C Storage temperature range - -40 ... + 85 °C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) f(Hz) = TCf(ppm/K) x (T-T0) x fTA(MHz) ***) matching components: for inductance, a Q-value of about 30 is to use generated: Dunzow W. checked / approved: Dr. Wall TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs133A.doc Version 1.2 VI TELEFILTER Filter specification 3. Construction and pin connection : 06.03.2003 2/5 (All dimensions in mm) 9,3 Max. 7 6 8 9 TFS 133A Date code: N P R ... 5 TFS 133 A R22 10 4 1 2 1 Year+week 2001 2002 2003 .... 3 Date code 5,08 2 3 Pin 6 Pin 7 Pin 1 Pin 2 Pin 3-5, 8-10 10 Input. Input RF Return. Output. Output RF Return. Package Ground. 9 0,1 0,9 0,8 4. 50 matching network ( details refer to application note ) : 9 10 L3 L2 1 8 50 7 2 3 6 50 L4 L1 5 Scheme 1 4 9 10 1 8 C1 7 2 L1 50 50 L2 Scheme 2 C2 3 6 5 4 For final test we use scheme 1. TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs133A.doc Version 1.2 VI TELEFILTER Filter specification 06.03.2003 TFS 133A 3/5 5. Stability characteristics : After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; 6. Packing : Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 2000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Tape (all dimensions in mm) Do W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 16 4 1,5 1,75 7,5 0,6 2 12 1,5 7,6 9,6 13,5 Po P 2 ± 0,3 ± 0,1 + 0,1 ± 0,1 ± 0,1 E A o F D CT ± 0,1 ± 0,1 B 1 W o ± 0,1 ± 0,1 ± 0,1 G P1 COVER TAPE W2 Reel (all dimensions in mm): A W1 W2(max) N(min) C : : : : : 330 16,4 22,4 60 12,8 +2 A C N ± 0,1 W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs133A.doc Version 1.2 VI TELEFILTER Filter specification TFS 133A 06.03.2003 4/5 7. Air reflow temperature conditions : 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 °C - 170 °C over 200 °C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs133A.doc Version 1.2 VI TELEFILTER Filter specification TFS 133A 06.03.2003 5/5 8. History : Version Reason of Changes Name Date 1.0 - generation of specification according to customer requirements. Dunzow W. 20.09.2002 1.1 - generate filter specification ; nd - add typical values of filter after 2 iteration . Dunzow W. 28.01.2003 1.2 - change package according to customer requirements. Dunzow W. 06.03.2003 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.