VECTRON TFS840

Tfs840.doc
version 1.2
VI TELEFILTER
02.09.2002
Filter Specification
TFS 840
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
°C
dBm
23
0
for input: 195Ω // -0,25 pF
for input: 195Ω // -0,25 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 840 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at
the -3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 840,0 MHz without tolerance. The given
values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance
for the centre frequency fc.
Data
typ. value
Insertion loss
(Reference level)
ae = amin
3,75
Nominal frequency
fN
-
Centre frequency
fc
840,0
2 dB Bandwidth
BW
Pass band ripple
within ± 20,0 MHz
Relative attenuation
arel
MHz
fN .... fN ± 20,0
fN - 160,0 MHz .... fN - 740,0
fN + 120,0 MHz .... fN + 260,0
fN + 260,0 MHz .... fN + 300,0
fN + 300,0 MHz .... fN + 660,0
Operating temperature range
MHz
MHz 50,0
MHz 50,0
MHz 50,0
Storage temperature range
49,50
1,5*
dB
max.
5,5
dB
840,0
MHz
MHz
MHz
MHz
min.
40,0
dB
max.
2,0
dB
max.
2,0
dB
50,0
dB
dB
dB
tolerance/limit
dB
min.
min.
min.
min.
40,0
dB
30,0
dB
45,0
dB
40,0
dB
- 25 °C ... + 75 °C
- 30 °C ... + 80 °C
*) 1,5 dB over fN ± 20 MHz at ambiente temperature (23 °C).
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs840.doc
version 1.2
VI TELEFILTER
02.09.2002
Filter Specification
TFS 840
2/5
Construction, pin configuration and 50 Ω - matching network
(All dimensions in mm)
5
7
1,78
840
SQ 3,81
+ 0,2 / -0,1
1,78
0,6
P36
1
Date code
Pin 1
Pin 2
Pin 3
Pin 4
0,1
3
2,54
1,1 Max.
Input
Ground
Ground
Package Ground
Pin 5
Pin 6
Pin 7
Pin 8
Date code:
M
N
P
...
Output
Ground
Ground
Package ground
Year + week
2000
2001
2002
50 Ohm Test circuit
L1
IN
1
C1
L2
5
SAW
C2
OUT
2,3,4,6,7,8
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs840.doc
version 1.2
VI TELEFILTER
02.09.2002
Filter Specification
TFS 840
3/5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
Tape (all dimensions in mm)
W
Po
Do
:
:
:
12
4
1,5
1,75 ± 0,1
5,5 ± 0,05
0,75
2 ± 0,05
P1
:
D1(min) :
Ao
:
8
± 0,1
1,5
4,3 ± 0,1
Bo
CT
4,3
9,5
:
:
EMBOSSED CARRIER TAPE
± 0,3
± 0,1
+ 0,1
E
:
F
:
G (min) :
P2
:
3000
min 300 mm
min 500 mm
min 300 mm
Do
Po
P2
E
Ao
F
D1
CT
W
Bo
G
P1
± 0,1
± 0,1
COVER TAPE
W2
Reel (all dimensions in mm):
A
:
W1
:
330
12,4 + 2,0
W2 (max) :
18,4
N (min)
:
50
C
:
13
A
-+0,5/ -0,2
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the
right side of the tape.
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs840.doc
version 1.2
VI TELEFILTER
02.09.2002
Filter Specification
TFS 840
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Tfs840.doc
version 1.2
VI TELEFILTER
Filter Specification
02.09.2002
TFS 840
5/5
History
Version
Reason of Changes
Name
Date
1.0
- Generation of development specification according to customer specification
Dr. Sabah
29.08.2001
1.1
- Change of relative attenuation
Dr. Sabah
13.09.2001
1.2
-add of terminating Impedance and typ. values; Filter Specification
Dr. Sabah
02.09.2002
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.