Tfs840.doc version 1.2 VI TELEFILTER 02.09.2002 Filter Specification TFS 840 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedances °C dBm 23 0 for input: 195Ω // -0,25 pF for input: 195Ω // -0,25 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 840 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the -3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 840,0 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (Reference level) ae = amin 3,75 Nominal frequency fN - Centre frequency fc 840,0 2 dB Bandwidth BW Pass band ripple within ± 20,0 MHz Relative attenuation arel MHz fN .... fN ± 20,0 fN - 160,0 MHz .... fN - 740,0 fN + 120,0 MHz .... fN + 260,0 fN + 260,0 MHz .... fN + 300,0 fN + 300,0 MHz .... fN + 660,0 Operating temperature range MHz MHz 50,0 MHz 50,0 MHz 50,0 Storage temperature range 49,50 1,5* dB max. 5,5 dB 840,0 MHz MHz MHz MHz min. 40,0 dB max. 2,0 dB max. 2,0 dB 50,0 dB dB dB tolerance/limit dB min. min. min. min. 40,0 dB 30,0 dB 45,0 dB 40,0 dB - 25 °C ... + 75 °C - 30 °C ... + 80 °C *) 1,5 dB over fN ± 20 MHz at ambiente temperature (23 °C). Generated: Checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs840.doc version 1.2 VI TELEFILTER 02.09.2002 Filter Specification TFS 840 2/5 Construction, pin configuration and 50 Ω - matching network (All dimensions in mm) 5 7 1,78 840 SQ 3,81 + 0,2 / -0,1 1,78 0,6 P36 1 Date code Pin 1 Pin 2 Pin 3 Pin 4 0,1 3 2,54 1,1 Max. Input Ground Ground Package Ground Pin 5 Pin 6 Pin 7 Pin 8 Date code: M N P ... Output Ground Ground Package ground Year + week 2000 2001 2002 50 Ohm Test circuit L1 IN 1 C1 L2 5 SAW C2 OUT 2,3,4,6,7,8 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs840.doc version 1.2 VI TELEFILTER 02.09.2002 Filter Specification TFS 840 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W Po Do : : : 12 4 1,5 1,75 ± 0,1 5,5 ± 0,05 0,75 2 ± 0,05 P1 : D1(min) : Ao : 8 ± 0,1 1,5 4,3 ± 0,1 Bo CT 4,3 9,5 : : EMBOSSED CARRIER TAPE ± 0,3 ± 0,1 + 0,1 E : F : G (min) : P2 : 3000 min 300 mm min 500 mm min 300 mm Do Po P2 E Ao F D1 CT W Bo G P1 ± 0,1 ± 0,1 COVER TAPE W2 Reel (all dimensions in mm): A : W1 : 330 12,4 + 2,0 W2 (max) : 18,4 N (min) : 50 C : 13 A -+0,5/ -0,2 C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs840.doc version 1.2 VI TELEFILTER 02.09.2002 Filter Specification TFS 840 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Tfs840.doc version 1.2 VI TELEFILTER Filter Specification 02.09.2002 TFS 840 5/5 History Version Reason of Changes Name Date 1.0 - Generation of development specification according to customer specification Dr. Sabah 29.08.2001 1.1 - Change of relative attenuation Dr. Sabah 13.09.2001 1.2 -add of terminating Impedance and typ. values; Filter Specification Dr. Sabah 02.09.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.