version 1.2 06.01.02 ______________________________________________________________________________________________________ tfs246d.eng TELE FILTER tft GmbH SAW filter specification TFS 246D 1/4 ______________________________________________________________________________________________________ Measurement condition 23 °C 0 dBm 670 Ω || -3,0 pF 670 Ω || -3,0 pF 100 nH Ambient temperature: Input power level: Source impedance: Load impedance: Ext.coil: Construction and pin connection see page 2 Characteristics Remark: Reference level for the relative attenuation arel of the TFS 246D is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. Preliminary Data typ. value tolerance / limit ______________________________________________________________________________________________________ 3,2 dB max 5 dB ae = amin Insertion loss (Reference level) ______________________________________________________________________________________________________ 246,0 MHz fo Center frequency ______________________________________________________________________________________________________ Relative attenuation 246,0 MHz ± 100 arel kHz max 3 dB 246,0 MHz ± 400 kHz ... 246,0 MHz ± 600 kHz 30 min 25 dB 246,0 MHz ± 600 kHz ... 246,0 MHz ± 800 kHz 40 min 36 dB 246,0 MHz ± 800 kHz ... 246,0 MHz ± 1,6 MHz 50 min 45 dB 246,0 MHz - 1,6 MHz ... 246,0 MHz - 25 MHz 57 min 50 dB 246,0 MHz + 1,6 MHz ... 246,0 MHz + 15 MHz 48 min 45 dB 246,0 MHz + 15 MHz ... 246,0 MHz + 25 MHz 55 min 50 dB ______________________________________________________________________________________________________ GDD Group delay distortion 246,0 MHz ± 70 kHz 1 µs max 1,5 µs ______________________________________________________________________________________________________ Operating temperature range - 25 °C ... + 85 °C Storage temperature range - 30 °C ... + 85 °C ______________________________________________________________________________________________________ ca. - 0,036 ppm/K² Temperature coefficient of frequency TC ______________________________________________________________________________________________________ Frequency inversion temperature + 25°C ______________________________________________________________________________________________________ generated: checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. version 1.2 06.01.02 ______________________________________________________________________________________________________ tfs246d.eng TELE FILTER tft GmbH SAW filter specification TFS 246D 2/4 ______________________________________________________________________________________________________ Construction and pin connection Pinning - ballanced TFS 246D G1 1 Output 6 Input 2 Output 7 Input 3 Ext.coil 8 Ground 4 Ground 9 Ground 5 Ground 10 Ground Pinning - unballanced 1 2 3 1 Output 6 Input 2 RF Return 7 RF-Return 10 4 9 5 8 7 3 Ext.coil 8 Ground 4 Ground 9 Ground 5 Ground 10 Ground 6 50 Ω test circuit (ballanced) LB-IN C3 C1 6 LB-OUT 1 SAW L1 L2 2 7 C2 C4 3 L3 4,5,8,9,10 50 Ω test circuit (unballanced) L3 6 L4 1 SAW C5 C6 3 2,4,5,7,8,9,10 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. version 1.2 06.01.02 ______________________________________________________________________________________________________ tfs246d.eng TELE FILTER tft GmbH SAW filter specification TFS 246D 3/4 ______________________________________________________________________________________________________ Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4; Packing Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: 2300 Tape (all dimensions in mm) W : 16 Po Do : : 4 ± 0,1 1,5 + 0,5 D1 E F : : : 1,5 + 0,5 1,75 ± 0,1 7,5 ± 0,1 G (min) : P2 : Do Po P2 E Ao 12 1,5 ± 0,1 Ao Bo 7,6 9,6 ± 0,1 ± 0,1 F D1 13,4 ± 0,1 W Bo 0,75 2 ± 0,1 P1 : D1(min) : : : EMBOSSED CARRIER TAPE ± 0,3 G P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 16,4 +2 22,4 >= 90 C C : 13 ± 0,25 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. version 1.2 06.01.02 ______________________________________________________________________________________________________ tfs246d.eng TELE FILTER tft GmbH SAW filter specification TFS 246D 4/4 ______________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.