VECTRON TFS380N

Filename: tfs 380n.doc
Version 1.1
VI TELEFILTER
10.10.2005
Filter specification
TFS 380N
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
499 Ω || -6,3 pF
480 Ω || -6,2 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 380 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation
arel of the TFS 380N is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter
attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
Insertion loss at fN
(reference level)
ae
Nominal frequency
fN
Centre frequency at ambient temperature
fC
Passband
PB
max.
11
380,0
MHz
fN
±
dB
380,0
MHz
± 0,4
MHz
2,0
MHz
0,8
dB
max.
1,5
dB
0,5
1
dB
dB
max.
max.
1
3
dB
dB
arel
fC
fC
±
3,0
MHz … fC
MHz … fC
±
±
fC
±
7,5
MHz … fC
±
Group delay ripple in fN ± 2,5
dB
-
Pass band ripple
Relative attenuation
8,5
tolerance / limit
3,0
3,75
50,0
MHz
MHz
MHz
MHz
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
34
dB
min.
30
dB
46
ns
max.
75
ns
-
- 40 °C … +85 °C
TCf **
-18
- 40 °C ... + 85 °C
ppm/K
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
Version 1.1
VI TELEFILTER
10.10.2005
Filter specification
TFS 380N
2/5
0
0.91
-1
0.85
-10
-2
0.79
-15
-3
0.73
-20
-4
0.67
-5
0.61
-6
0.55
-35
-7
0.49
-40
-8
0.43
-45
-9
0.37
-25
-30
-50
330
340
350
360
370
380
390
frequency in MHz
400
410
420
-10
375
430
376
377
378
379
380
381
frequency in MHz
382
383
384
delay in µs
0
-5
magnitude in dB
magnitude in dB
Filter characteristic
0.31
385
Construction and pin connection
(All dimensions in mm)
S 380N
●
T42
3
Date code
2 Max.
1
1
5,2 Max.
2,54 ±0,2
7,2 Max.
2,54 ±0,2
1
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Ground
Input RF Return
Input
Ground
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
0,80
50 Ω Test circuit
10
L1
9
4
SAW
L2
L3
3
L4
1, 2, 5, 6, 7, 8, 11, 12
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
Version 1.1
VI TELEFILTER
10.10.2005
Filter specification
TFS 380N
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
t
P1
Date Code
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
Version 1.1
VI TELEFILTER
10.10.2005
Filter specification
TFS 380N
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 380n.doc
VI TELEFILTER
Version 1.1
Filter specification
10.10.2005
TFS 380N
5/5
History
Version
Reason of Changes
Name
Date
1.0
Generation of development specification
Strehl
22.09.2005
1.1
terminating impedance, typical values and filter characteristic added
Pfeiffer
10.10.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.