VECTRON TFS110P

file: tfs110p.doc
version 2.1
05.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 110P
1/4
____________________________________________________________________________________________________
Measurement condition
Ambient temperature:
23°C
Input power level:
0 dBm
Terminating impedances
for input:
2,9 kΩ || -6.2 pF
for output:
2,8 kΩ || -5.5 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 110 P is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at
the 30 dB filter attenuation level relative to the insertion loss ae.
Data
typ. value
tolerance / limit
____________________________________________________________________________________________________
ae = amin
Insertion loss
8
dB
10
dB
(reference level)
____________________________________________________________________________________________________
fc (30 dB-BW)
Reference frequency
110,592 MHz
± 60
kHz
____________________________________________________________________________________________________
Gaussian
Pass band shape (3 dB-BW)
____________________________________________________________________________________________________
3 dB bandwidth
965
kHz
BW
10 dB bandwidth
1695
kHz
20 dB bandwidth
2255
kHz
30 dB bandwidth
2600
kHz
40 dB bandwidth
2840
kHz
____________________________________________________________________________________________________
arel
Relative attenuation
fc + 475
kHz
≤ 3
dB
fc - 425
kHz
≤ 3
dB
fc ± 800
kHz
≤ 10
dB
fc + 1200
kHz
≥ 20
dB
fc - 1210
kHz
≥ 20
dB
fc + 1375
kHz
≥ 30
dB
fc - 1395
kHz
≥ 30
dB
fc + 1500
kHz ... fc + 5
MHz
> 40
dB
≥ 35
dB
fc +
5
MHz ... fc +10
MHz
> 40
dB
≥ 30
dB
fc - 1535
kHz ... fc - 10
MHz
> 45
dB
≥ 40
dB
____________________________________________________________________________________________________
GD
Group delay
Ripple fc ± 576 kHz
250
ns
max 400
ns
____________________________________________________________________________________________________
TC 2nd order *)
Temperature coefficient
- 0,032 ppm/K²
____________________________________________________________________________________________________
t.b.d.
Frequency inversion temperature To
____________________________________________________________________________________________________
Operating temperature range
- 10 °C ... + 60 °C
Storage temperature range
- 40 °C ... + 85 °C
____________________________________________________________________________________________________
Input power level
max. + 10
dBm
____________________________________________________________________________________________________
*) - ∆f (Hz) = TC (ppm/K²) x (T - To)² x FTo (MHz)
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: tfs110p.doc
version 2.1
05.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 110P
2/4
____________________________________________________________________________________________________
Construction and pin connection
(All dimensions in mm)
S 110 P
L9
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Output RF Return
Output
Ground
Ground
Ground
Ground
Input RF Return
Input
Ground
Ground
50 Ω test circuit
L2
L1
10
Input
50 Ohm
4
Input
50 Ohm
SAW
C1
C2
1,2,3,5,6,7,
8,9,11,12
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: tfs110p.doc
version 2.1
05.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 110P
3/4
____________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Real of empty components at start:
Real of empty components at start including leader:
Trailer
Tape (all dimensions in mm)
W
:
16
± 0,3
Po
:
4
± 0,1
Do
:
1,5
+ 0,5
D1
E
F
:
:
:
1,5 + 0,5
1,75 ± 0,1
7,5 ± 0,1
G (min) :
P2
:
8
1,5
± 0,1
Ao
Bo
5,4
7,4
± 0,1
± 0,1
:
:
EMBOSSED CARRIER TAPE
Do
Po
P2
E
Ao
F
D1
13,4
± 0,1
W
Bo
0,75
2 ± 0,05
P1
:
D1(min) :
3000
min 300 mm
min 500 mm
min 300 mm
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
:
W1
W2 (max) :
:
N (min)
:
330
16,4 +2
22,4
>= 90
C
C
:
13
± 0,25
A
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
file: tfs110p.doc
version 2.1
05.01.02
______________________________________________________________________________________________________
VI
TELEFILTER
Filter specification
TFS 110P
4/4
____________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.