file: tfs110p.doc version 2.1 05.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 110P 1/4 ____________________________________________________________________________________________________ Measurement condition Ambient temperature: 23°C Input power level: 0 dBm Terminating impedances for input: 2,9 kΩ || -6.2 pF for output: 2,8 kΩ || -5.5 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 110 P is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter attenuation level relative to the insertion loss ae. Data typ. value tolerance / limit ____________________________________________________________________________________________________ ae = amin Insertion loss 8 dB 10 dB (reference level) ____________________________________________________________________________________________________ fc (30 dB-BW) Reference frequency 110,592 MHz ± 60 kHz ____________________________________________________________________________________________________ Gaussian Pass band shape (3 dB-BW) ____________________________________________________________________________________________________ 3 dB bandwidth 965 kHz BW 10 dB bandwidth 1695 kHz 20 dB bandwidth 2255 kHz 30 dB bandwidth 2600 kHz 40 dB bandwidth 2840 kHz ____________________________________________________________________________________________________ arel Relative attenuation fc + 475 kHz ≤ 3 dB fc - 425 kHz ≤ 3 dB fc ± 800 kHz ≤ 10 dB fc + 1200 kHz ≥ 20 dB fc - 1210 kHz ≥ 20 dB fc + 1375 kHz ≥ 30 dB fc - 1395 kHz ≥ 30 dB fc + 1500 kHz ... fc + 5 MHz > 40 dB ≥ 35 dB fc + 5 MHz ... fc +10 MHz > 40 dB ≥ 30 dB fc - 1535 kHz ... fc - 10 MHz > 45 dB ≥ 40 dB ____________________________________________________________________________________________________ GD Group delay Ripple fc ± 576 kHz 250 ns max 400 ns ____________________________________________________________________________________________________ TC 2nd order *) Temperature coefficient - 0,032 ppm/K² ____________________________________________________________________________________________________ t.b.d. Frequency inversion temperature To ____________________________________________________________________________________________________ Operating temperature range - 10 °C ... + 60 °C Storage temperature range - 40 °C ... + 85 °C ____________________________________________________________________________________________________ Input power level max. + 10 dBm ____________________________________________________________________________________________________ *) - ∆f (Hz) = TC (ppm/K²) x (T - To)² x FTo (MHz) Generated: Checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: tfs110p.doc version 2.1 05.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 110P 2/4 ____________________________________________________________________________________________________ Construction and pin connection (All dimensions in mm) S 110 P L9 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground 50 Ω test circuit L2 L1 10 Input 50 Ohm 4 Input 50 Ohm SAW C1 C2 1,2,3,5,6,7, 8,9,11,12 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: tfs110p.doc version 2.1 05.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 110P 3/4 ____________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Damp heat: (cycle) 25 °C to 55°C / 95% r.H. / 10 cycles DIN IEC 68 - 2 – 30 Db 4. Resistance to solder heat (reflow): max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer Tape (all dimensions in mm) W : 16 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 D1 E F : : : 1,5 + 0,5 1,75 ± 0,1 7,5 ± 0,1 G (min) : P2 : 8 1,5 ± 0,1 Ao Bo 5,4 7,4 ± 0,1 ± 0,1 : : EMBOSSED CARRIER TAPE Do Po P2 E Ao F D1 13,4 ± 0,1 W Bo 0,75 2 ± 0,05 P1 : D1(min) : 3000 min 300 mm min 500 mm min 300 mm G P1 COVER TAPE W 2 Reel (all dimensions in mm): A : W1 W2 (max) : : N (min) : 330 16,4 +2 22,4 >= 90 C C : 13 ± 0,25 A N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: tfs110p.doc version 2.1 05.01.02 ______________________________________________________________________________________________________ VI TELEFILTER Filter specification TFS 110P 4/4 ____________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Straße 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: [email protected] E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.