VCXO-2070S 1. Specification Nominal Frequency Range: 2 MHz to 32 MHz Nominal freq. tolerance @ Uc = 2.5V, T = 25 ± 3°C: < + 10 ppm Frequency deviation after reflow and cooling to 25°C: < ± 3 ppm Frequency stability in the temperature range - 20°C to + 70°C: vs. supply voltage changes UB ± 5%: vs. load changes ± 5%: < + 15 ppm < + 5 ppm < + 5 ppm Aging @ 25°C : < + 5 ppm / first year < + 2 ppm / year in the following years Frequency control range: > + 100 ppm Control voltage Uc : 0.5 V to 4.5 V Transfer function / Linearity: positive / 10% Supply voltage UB: 5 V ± 5% Current consumption: < 25 mA Output voltage : load : duty cycle : rise time, fall time: HCMOS 1 kOhm // 15 pF 40% / 60% < 8 ns (load 1kOhm//15pF) Temperature ranges Operating: Operable: Storage: -20°C ... + 70°C -25°C ... + 75°C -40°C ... + 85°C 2. Environmental conditions Shock: DIN IEC 68-2-27,Test Ea, 100 g, 6ms Half-sine, 3 bumps in 3 main directions Vibration: DIN IEC 68-2-6, Test Fc, 10-500Hz, 10g, 2 h in 3 main directions Humidity: DIN IEC 68-2-3, 40°C/93%RH, 21 days Solderability: DIN IEC 68-2-20 only for wire leads, Methode 3: Solder globule at + 235°C USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON EUROPE: Tel: 49 (0) 3328 4784 17 • Fax: 49 (0) 3328 4784 30 ASIA: www.vectron.com Tel: +86 21 28909740 / 41 / 42 • Fax: +86 21 28909240 / 2890999 Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. VCXO-2070S 3. Marking Manufacturer's name, date code(week/year); Specification; Center frequency 4. Case Case style: BF 141 1.Pin configuration 1. Control voltage UC = 0.5V...4.5V 2. Ground, Case 3. RF-Output 4. Supply voltage UB 5. Test circuit U_control O V 1 Oscillator +UB O 4 A 975 Ohm O 3 Oscilloscope, Counter or Spectrum Analyzer RE = 50 Ohm 2 V 15 pF 50 Ohm GND O USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON EUROPE: Tel: 49 (0) 3328 4784 17 • Fax: 49 (0) 3328 4784 30 ASIA: www.vectron.com Tel: +86 21 28909740 / 41 / 42 • Fax: +86 21 28909240 / 2890999 Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.