VECTRON TO-300

TO-300
1. Specification
Specification:
TO-301
TO-302
Frequency range:
TO-311
TO-312
10.00 ... 40.00 MHz
< + 3 ppm
Nominal frequency tolerance:
Stability in the temperature range - 20°C to + 70°C:
< + 3 ppm Uc=2.5 V
<+ 1 ppm <+ 2 ppm <+ 1 ppm
Frequency stability
vs. supply voltage changes UB ± 5 %:
vs. load changes ± 5 %:
<+ 2 ppm
< + 1 ppm
< + 1 ppm
Aging @ 25°C:
+ 2 ppm first / + 1 ppm following years
Frequency correction:
± 5 ppm
by int. trimmer
± 8 ppm by ext.
voltage 0.5 ... 4.5 V
-
positive
Transfer function / Linearity:
5V±5%
Supply voltage UB:
Current consumption:
< 5 mA
Output voltage :
load :
level :
Sinusoidal
560 Ohm
> 500 mVpp
Phase noise:
100 Hz
1000 Hz
-105 dBc/Hz
-120 dBc/Hz
-20°C ... + 70°C
-25°C ... + 75°C
-40°C ... + 85°C
Operating Temperature range:
Operable Temperature range:
Storage Temperature range:
2. Environmental conditions
Shock:
DIN IEC 68-2-27,Test Ea, 100 g, 6ms
Half-sine, 3 bumps in 3 main directions
Vibration:
DIN IEC 68-2-6, Test Fc, 10-500Hz, 10g,
2 h in 3 main directions
Humidity:
DIN IEC 68-2-3, 40°C/93%RH, 21 days
Solderability:
DIN IEC 68-2-20 only for wire leads,
Methode 3: Solder globule at + 235°C
3. Marking
USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON
EUROPE: Tel: 49 (0) 3328 4784 17 • Fax: 49 (0) 3328 4784 30
ASIA: Tel: +86 21 28909740 / 41 /42 • Fax: +86 21 28909240 / 2890999
www.vectron.com
Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
TO-300
Manufacturer's name, date code(week/year)
Specification
Center frequency
4. Case
Case style: BF-100
1.Pin configuration
TO-301 / TO-302:
1. N.C.
7. Ground, case
8. RF-output
14. Supply voltage
TO-311 / TO-312:
1. Control voltage Uc
7. Ground, case
8. RF-output
14. Supply voltage
5. Test circuit
TO-301/TO-302:
1
Oscillator
+UB
O
A
14
535 Ohm
8
O
Oscilloscop
RE = 50
O
Oscilloscop
RE = 50
Ohm
O
Counter
7
V
50 Ohm
GND
O
TO-311/TO-312:
+Ustell
O
1
V
Oscillator
+UB
O
A
14
535 Ohm
8
O
7
V
50 Ohm
GND
O
USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON
EUROPE: Tel: 49 (0) 3328 4784 17 • Fax: 49 (0) 3328 4784 30
ASIA: Tel: +86 21 28909740 / 41 / 42 • Fax: +86 21 28909240 / 2890999
www.vectron.com
Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.
Counter