TO-300 1. Specification Specification: TO-301 TO-302 Frequency range: TO-311 TO-312 10.00 ... 40.00 MHz < + 3 ppm Nominal frequency tolerance: Stability in the temperature range - 20°C to + 70°C: < + 3 ppm Uc=2.5 V <+ 1 ppm <+ 2 ppm <+ 1 ppm Frequency stability vs. supply voltage changes UB ± 5 %: vs. load changes ± 5 %: <+ 2 ppm < + 1 ppm < + 1 ppm Aging @ 25°C: + 2 ppm first / + 1 ppm following years Frequency correction: ± 5 ppm by int. trimmer ± 8 ppm by ext. voltage 0.5 ... 4.5 V - positive Transfer function / Linearity: 5V±5% Supply voltage UB: Current consumption: < 5 mA Output voltage : load : level : Sinusoidal 560 Ohm > 500 mVpp Phase noise: 100 Hz 1000 Hz -105 dBc/Hz -120 dBc/Hz -20°C ... + 70°C -25°C ... + 75°C -40°C ... + 85°C Operating Temperature range: Operable Temperature range: Storage Temperature range: 2. Environmental conditions Shock: DIN IEC 68-2-27,Test Ea, 100 g, 6ms Half-sine, 3 bumps in 3 main directions Vibration: DIN IEC 68-2-6, Test Fc, 10-500Hz, 10g, 2 h in 3 main directions Humidity: DIN IEC 68-2-3, 40°C/93%RH, 21 days Solderability: DIN IEC 68-2-20 only for wire leads, Methode 3: Solder globule at + 235°C 3. Marking USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON EUROPE: Tel: 49 (0) 3328 4784 17 • Fax: 49 (0) 3328 4784 30 ASIA: Tel: +86 21 28909740 / 41 /42 • Fax: +86 21 28909240 / 2890999 www.vectron.com Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TO-300 Manufacturer's name, date code(week/year) Specification Center frequency 4. Case Case style: BF-100 1.Pin configuration TO-301 / TO-302: 1. N.C. 7. Ground, case 8. RF-output 14. Supply voltage TO-311 / TO-312: 1. Control voltage Uc 7. Ground, case 8. RF-output 14. Supply voltage 5. Test circuit TO-301/TO-302: 1 Oscillator +UB O A 14 535 Ohm 8 O Oscilloscop RE = 50 O Oscilloscop RE = 50 Ohm O Counter 7 V 50 Ohm GND O TO-311/TO-312: +Ustell O 1 V Oscillator +UB O A 14 535 Ohm 8 O 7 V 50 Ohm GND O USA: Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON EUROPE: Tel: 49 (0) 3328 4784 17 • Fax: 49 (0) 3328 4784 30 ASIA: Tel: +86 21 28909740 / 41 / 42 • Fax: +86 21 28909240 / 2890999 www.vectron.com Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Counter