OMRON G3VM-SY

MOS FET Relay
G3VM-SY
Relay Incorporating a MOS FET
Optically Coupled with an Infrared LED
in a Miniature Flat Package
Low offset voltage when the Relay is OFF.
Ideal for minute-signal scanning circuits and the
subscriber circuits of digital telephone exchange
systems for switching analog signals.
Ordering Information
Appearance
OMRON logo
Model name
Lot No.
Note:
“G3VM” is not printed on the actual product
Contact form
DPST-ND
Note:
Terminals
Surface-mounting terminals
(see note)
Load voltage
(peak value)
60 VAC
Model
G3VM-SY
Surface-mounting terminal models are also available on tape.
Application Examples
•
•
Electronic automatic exchange systems
Gauging control systems
•
•
Data management systems
Gauging systems
Specifications
•
•
•
General Specifications
Eight-pin SOP with two circuits (DPST-NO)
Output dielectric strength: 60 V min.
Trigger LED current: 3 mA max.
•
•
•
Continuous load current: 300 mA max.
Output ON resistance: 2 Ω max.
Insulation resistance between I/O pins: 1,500 Vrms min.
27
G3VM-SY
G3VM-SY
Absolute Maximum Ratings (Ta = 25°C)
Item
Input
pu
Symbol
Rating
Unit
LED forward current
IF
50
mA
DC forward current reduction rate (Tay25_C)
n IF/_C
–0.5
mA/_C
Repetitive peak LED forward current (100 µs pulse, 100 pps)
IFP
1
A
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
_C
Output dielectric strength
VOFF
60
V
Continuous load current (see note 1 )
IO
300
mA
ON current reduction rate (Tay25_C)
n ION/_C
–3.0
mA/_C
Connection temperature
Tj
125
_C
Storage temperature
Tstg
–55 to 100
_C
Operating temperature
Ta
–20 to 85
_C
Soldering temperature (10 s)
Tsol
260
_C
Dielectric strength (AC for 1 min with ambient humidity of 60% or less)
(see note 2)
VI-O
1,500
Vrms
Output
Ou
pu
Note:
1. The output load current varies depending on the ambient temperature. Refer to Engineering Data.
2. Impose voltage between a group of the whole input pins and that of the whole output pin.
Recommended Operating Conditions
Item
Symbol
Minimum
Typical
Maximum
Unit
Operating voltage
VDD
---
---
48
V
Forward current
IF
5
10
25
mA
Continuous load current
IO
---
---
300
mA
Operating temperature
Topr
–20
---
65
_C
Electrical Characteristics (Ta = 25°C)
Item
Input
pu
Output
Symbol
Measurement
conditions
Minimum
Typical
Maximum
Unit
LED forward current
VF
IF=10 mA
1.0
1.15
1.3
V
Reverse current
IR
VR=5 V
---
---
10
µA
Capacity between terminals
CT
V=0, , f=1MHZ
---
30
---
pF
Current leakage when the relay
is open
ILEAK
VOFF=60 V
---
---
1
µA
Connection Characteristics (Ta = 25°C)
Item
Symbol
Maximum resistance with output ON
RON
Measurement conditions
ION=300 mA, IF=10 mA
Minimum
Typical
---
1.4
Maximum
Unit
Ω
2
Insulation Characteristics (Ta = 25°C)
Item
Symbol
Measurement conditions
Minimum
Typical
Maximum
Unit
Floating capacity between
I/O terminals
CI-O
VI–O=0, f=1MHZ
---
0.8
---
pF
Insulation resistance
RI-O
VI–O=500 V, operating
ambient humidity: x60%
5 x 1010
1014
---
Ω
Dielectric
e ec c s
strength
e g
VI-O
AC for 1 min
1,500
---
---
Vrms
AC for 1 s in oil
---
3,000
---
DC for 1 min in oil
---
3,000
---
28
Vdc
G3VM-SY
G3VM-SY
Switching Characteristics (Ta = 25°C)
Item
Symbol
Turn-on time
tON
Turn-off time
tOFF
Note:
Measurement
conditions
Minimum
RL=200 Ω
VDD=20 V,
V
IF=10 mA (see note)
Typical
Maximum
---
---
2
---
---
1
Unit
ms
Switching Time Measuring Circuit
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-SY
Terminal Arrangement/
Internal Connections
(Top View)
21 max.
Unit: mm
Weight: 0.2 g
6 to 6.3
Precautions
Correct Use
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will
operate properly.
Item
Min.
Type
Max.
Operating LED forward
current
5 mA
7.5 mA
25 mA
Releasing LED forward
current
0V
---
0.8 V
Note:
Refer to page 35 for precautions common to all G3VM models.
29