G3VM-61PR(TR)

MOS FET Relays
G3VM-61PR
Smallest Class in market, USOP
Package MOS FET Relays (COFF
(typical): 20 pF, RON (typical): 1 Ω) with
Low Output Capacitance and ON
Resistance (C × R = 20 pF•Ω) in a 60-V
Load Voltage Model.
• ON resistance of 1 Ω (typical) suppresses output signal
attenuation.
Note:
The actual product is marked differently from the image
shown here.
RoHS compliant
■ Application Examples
• Semiconductor inspection tools
• Measurement devices
• Broadband systems
• Data loggers
■ List of Models (Ask your OMRON representative for delivery times.)
Contact form
SPST-NO
Note:
Terminals
Surface-mounting
terminals
Load voltage (peak value)
(See note)
60 V
Model
Minimum packaging unit
Number per tape
G3VM-61PR
---
G3VM-61PR(TR)
1,500
1. Ask your OMRON representative for orders under 1,500 pcs.
2. Tape-cut USOPs are packaged without humidity resistance.
Use manual soldering to mount them. Refer to common precautions.
3. The AC peak and DC value is given for the load voltages.
■ Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-61PR
3.25
2.05
0.15 1.65
(0.4)
Note: The actual product is marked differently
from the image shown here.
1.27
0.2
2.85
2.2
Note: A tolerance of ±0.2 mm applies
to all dimensions unless otherwise specified.
(0.35)
Weight: 0.03 g
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-61PR
4
3
932
1
Pin 1
2
The actual product is marked
differently from the image
shown here.
Beveled side is input side.
Pin 1
■ Actual Mounting Pad Dimensions (Recommended Value, Top View)
G3VM-61PR
0.85 2.9
0.8
1.27
G3VM-61PR
G3VM-61PR
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
Rating
Unit
Measurement Conditions
Note:
LED forward current
IF
50
mA
LED forward current reduction rate
∆ IF/°C
−0.5
mA/°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Load voltage (AC peak / DC)
VOFF
60
V
Continuous load current (AC peak / DC)
IO
400
mA
ON current reduction rate
∆ IO/°C
−4.0
mA/°C
Connection temperature
Tj
125
°C
Dielectric strength between input and
output (See note 1.)
VI-O
500
Vrms
AC for 1 min
Ambient operating temperature
Ta
−40 to +85
°C
With no icing or condensation
Storage temperature
Tstg
−40 to +125
°C
With no icing or condensation
Soldering temperature
---
260
°C
10 s
Input
Output
Ta ≥ 25°C
1. The dielectric strength between the input and output was checked by
applying voltage between
all pins as a group on the
LED side and all pins as a
group on the light-receiving side.
Ta ≥ 25°C
■ Electrical Characteristics (Ta = 25°C)
Item
Input
Symbol
Minimum
Typical
Maximum
Unit
Measurement
conditions
Note:
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
µA
VR = 5 V
Capacity between terminals
CT
---
15
---
pF
V = 0, f = 1 MHz
Trigger LED forward current
IFT
---
0.5
3
mA
IO = 100 mA
Maximum resistance with output ON
RON
---
1.0
1.5
Ω
IF = 5 mA, IO = 400 mA,
t<1s
Current leakage when the relay is open
ILEAK
---
---
1
nA
VOFF = 60 V, Ta = 25°C
Capacity between terminals
COFF
---
20
30
pF
V = 0, f = 1 MHz,
t<1s
Capacity between I/O terminals
CI-O
---
0.3
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance between I/O terminals
RI-O
1,000
---
---
MΩ
VI-O = 500 VDC,
RoH ≤ 60%
Turn-ON time
tON
---
0.3
0.5
ms
Turn-OFF time
tOFF
---
0.3
0.5
ms
Output
2. Turn-ON and Turn-OFF
Times
IF
1
4
2
3
VOUT
10%
t ON
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
VDD
---
---
Operating LED forward current
IF
5
Continuous load current (AC peak / DC)
IO
---
Operating temperature
Ta
−20
---
Maximum
Unit
48
V
7.5
20
mA
---
400
mA
65
°C
■ Engineering Data
■ Safety Precautions
Load Current vs. Ambient Temperature
Refer to “Common Precautions” for all G3VM models.
Load current (mA)
G3VM-61PR
500
400
300
200
100
0
−20
0
20
40
60
80
100
Ambient temperature (°C)
VDD
VOUT
IF
■ Recommended Operating Conditions
Load voltage (AC peak / DC)
RL
90%
t OFF