MOS FET Relays G3VM-601AY/DY Compact, General-purpose, Analogswitching MOS FET Relays, with Dielectric Strength of 5 kVAC between I/O Using Optical Isolation. • Trigger LED forward current of 2 mA (maximum) facilities power saving designs. • Switches minute analog signals. • Continuous load current of 90 mA. Note: RoHS compliant The actual product is marked differently from the image shown here. ! Refer to “Common Precautions”. ■ Application Examples • Power meter • Measurement devices • Security systems • Industrial equipment ■ List of Models Contact form SPST-NO Terminals Load voltage (peak value) (See the note.) PCB terminals 600 V Number per stick G3VM-601AY Surface-mounting terminals Note: Model Number per tape 100 --- --- 1,500 G3VM-601DY G3VM-601DY(TR) The AC peak and DC value are given for the load voltage. ■ Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-601AY G3VM-601DY 4.58±0.25 4.58±0.25 6.4±0.25 6.4±0.25 7.62±0.25 7.62±0.25 0.8±0.25 +0.15 3.65 −0.25 +0.15 3.65 −0.25 Note: The actual product is marked differently from the image shown here. 2.5 min. 1.2±0.15 0.5±0.1 2.54±0.25 7.85 to 8.80 Weight: 0.25 g Note: The actual product is marked differently from the image shown here. 4.0 +0.25 −0.2 1.0 min. +0.1 0.25 −0.05 1.2±0.15 1.0 min. 2.54±0.25 10.0 max. Weight: 0.25 g ■ Terminal Arrangement/Internal Connections (Top View) G3VM-601AY 4 G3VM-601DY 3 4 3 Mold pin mark OMRON logo Model name LOT.NO. Pin 1 mark 1 2 1 ■ PCB Dimensions (Bottom View) G3VM-601AY Four 0.8-dia. holes 2.54 (0.61) 2 Note: The actual product is marked differently from the image shown here. ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-601DY 2.54 2.54 8.3 to 8.8 (1.52) (0.61) (1.52) 1.3 1.5 1 G3VM-601AY/DY G3VM-601AY/DY ■ Absolute Maximum Ratings (Ta = 25C) Item Input Output Symbol Rating Unit Measurement Conditions Note: LED forward current IF 30 mA Repetitive peak LED forward current IFP 1 A 100 s pulses, 100 pps LED forward current reduction rate IF/C 0.3 mA/C Ta 25C LED reverse voltage VR 5 V Connection temperature Tj 125 C Load voltage (AC peak/DC) VOFF 600 V Continuous load current (AC peak/DC) IO 90 mA ON current reduction rate IO/C 0.9 mA/C Ta 25C Pulse ON current Iop 0.27 A t = 100 ms, Duty = 1/10 Connection temperature Tj 125 C VI-O 5,000 Vrms AC for 1 min Dielectric strength between input and output (See note 1.) Operating temperature Ta 40 to +85 C With no icing or condensation Storage temperature Tstg 55 to +125 C With no icing or condensation Soldering temperature (10 s) --- 260 C 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. 10 s ■ Electrical Characteristics (Ta = 25C) Item Input Output Symbol Minimum Typical Maximum Unit Measurement conditions Note: LED forward voltage VF 1.45 1.63 1.75 V IF = 10 mA Reverse current IR --- --- 10 A VR = 5 V Capacity between terminals CT --- 40 --- pF V = 0, f = 1 MHz 2. Turn-ON and Turn-OFF Times IF Trigger LED forward current IFT --- 0.3 2 mA IO = 90 mA Maximum resistance with output ON RON --- 30 40 IF = 5 mA, IO = 90 mA, t < 1 s 45 60 IF = 5 mA, IO = 90 mA 1 4 2 3 RL VDD VOUT IF Current leakage when the relay is open ILEAK --- --- 1.0 A VOFF = 600 V Capacity between terminals COFF --- 75 --- pF V = 0, f = 1 MHz Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V Insulation resistance RI-O 1,000 --- --- M VI-O = 500 VDC, RoH 60% Turn-ON time tON --- 0.2 1 ms Turn-OFF time tOFF --- 0.2 1 ms IF = 5 mA, RL = 200 VDD = 10 V (See note 2.) VOUT 10% t ON 90% t OFF ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Load voltage (AC peak/DC) Minimum Typical Maximum Unit VDD --- --- 480 V Operating LED forward current IF 3 5 20 mA Continuous load current (AC peak/DC) IO --- --- 90 mA Operating temperature Ta 20 --- 65 C ■ Engineering Data ■ Safety Precautions Load Current vs. Ambient Temperature Refer to “Common Precautions” for all G3VM models. Load current (mA) G3VM-601AY(DY) 140 120 100 80 60 40 20 0 −20 0 20 40 60 80 100 Ambient temperature (°C) 2