OMRON G3VM

MOS FET Relays
G3VM-601AY/DY
Compact, General-purpose, Analogswitching MOS FET Relays, with
Dielectric Strength of 5 kVAC between
I/O Using Optical Isolation.
• Trigger LED forward current of 2 mA (maximum) facilities
power saving designs.
• Switches minute analog signals.
• Continuous load current of 90 mA.
Note:
RoHS compliant
The actual product is marked differently from the image
shown here.
! Refer to “Common Precautions”.
■ Application Examples
• Power meter
• Measurement devices
• Security systems
• Industrial equipment
■ List of Models
Contact form
SPST-NO
Terminals
Load voltage (peak value)
(See the note.)
PCB terminals
600 V
Number per stick
G3VM-601AY
Surface-mounting
terminals
Note:
Model
Number per tape
100
---
---
1,500
G3VM-601DY
G3VM-601DY(TR)
The AC peak and DC value are given for the load voltage.
■ Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G3VM-601AY
G3VM-601DY
4.58±0.25
4.58±0.25
6.4±0.25
6.4±0.25
7.62±0.25
7.62±0.25
0.8±0.25
+0.15
3.65 −0.25
+0.15
3.65 −0.25
Note: The actual product
is marked differently from the image
shown here.
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
7.85 to 8.80
Weight: 0.25 g
Note: The actual product
is marked differently from the image
shown here.
4.0 +0.25
−0.2
1.0
min.
+0.1
0.25 −0.05
1.2±0.15
1.0 min.
2.54±0.25
10.0 max.
Weight: 0.25 g
■ Terminal Arrangement/Internal Connections (Top View)
G3VM-601AY
4
G3VM-601DY
3
4
3
Mold pin mark
OMRON logo
Model name
LOT.NO.
Pin 1 mark
1
2
1
■ PCB Dimensions (Bottom View)
G3VM-601AY
Four 0.8-dia. holes
2.54
(0.61)
2
Note: The actual product is marked differently
from the image shown here.
■ Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-601DY
2.54
2.54
8.3 to 8.8
(1.52)
(0.61)
(1.52)
1.3
1.5
1
G3VM-601AY/DY
G3VM-601AY/DY
■ Absolute Maximum Ratings (Ta = 25C)
Item
Input
Output
Symbol
Rating
Unit
Measurement Conditions
Note:
LED forward current
IF
30
mA
Repetitive peak LED forward
current
IFP
1
A
100 s pulses, 100 pps
LED forward current reduction rate
 IF/C
0.3
mA/C
Ta  25C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
C
Load voltage (AC peak/DC)
VOFF
600
V
Continuous load current (AC
peak/DC)
IO
90
mA
ON current reduction rate
 IO/C
0.9
mA/C
Ta  25C
Pulse ON current
Iop
0.27
A
t = 100 ms, Duty = 1/10
Connection temperature
Tj
125
C
VI-O
5,000
Vrms
AC for 1 min
Dielectric strength between input and
output (See note 1.)
Operating temperature
Ta
40 to +85
C
With no icing or condensation
Storage temperature
Tstg
55 to +125 C
With no icing or condensation
Soldering temperature (10 s)
---
260
C
1. The dielectric strength between the input and
output was checked by applying voltage between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
10 s
■ Electrical Characteristics (Ta = 25C)
Item
Input
Output
Symbol
Minimum
Typical
Maximum
Unit
Measurement
conditions
Note:
LED forward voltage
VF
1.45
1.63
1.75
V
IF = 10 mA
Reverse current
IR
---
---
10
A
VR = 5 V
Capacity between terminals
CT
---
40
---
pF
V = 0, f = 1 MHz
2. Turn-ON and Turn-OFF
Times
IF
Trigger LED forward current
IFT
---
0.3
2
mA
IO = 90 mA
Maximum resistance with output ON
RON
---
30
40

IF = 5 mA,
IO = 90 mA, t < 1 s
45
60
IF = 5 mA,
IO = 90 mA
1
4
2
3
RL
VDD
VOUT
IF
Current leakage when the relay is
open
ILEAK
---
---
1.0
A
VOFF = 600 V
Capacity between terminals
COFF
---
75
---
pF
V = 0, f = 1 MHz
Capacity between I/O terminals
CI-O
---
0.8
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
---
M
VI-O = 500 VDC,
RoH  60%
Turn-ON time
tON
---
0.2
1
ms
Turn-OFF time
tOFF
---
0.2
1
ms
IF = 5 mA, RL = 200 
VDD = 10 V (See note 2.)
VOUT
10%
t ON
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Load voltage (AC peak/DC)
Minimum
Typical
Maximum
Unit
VDD
---
---
480
V
Operating LED forward current
IF
3
5
20
mA
Continuous load current (AC peak/DC)
IO
---
---
90
mA
Operating temperature
Ta
 20
---
65
C
■ Engineering Data
■ Safety Precautions
Load Current vs. Ambient Temperature
Refer to “Common Precautions” for all G3VM models.
Load current (mA)
G3VM-601AY(DY)
140
120
100
80
60
40
20
0
−20
0
20
40
60
80
100
Ambient temperature (°C)
2