SEMTECH SC190AIMLTRT

SC190
Synchronous Buck Converter
with Programmable Output
POWER MANAGEMENT
Description
Features
Features
The SC190 is a synchronous step-down converter with
integrated power devices and an integrated front-end
LDO to minimize input supply ripple. Output voltage is
programmable using two control bits, eliminating the need
for feedback resistors tied to the output. The device is
offered in four distinct variants with each variant providing
four fixed output voltage options to choose from.
 Less than 1mV Supply Ripple
 Output Voltage Regulated by Either the Switching




The front-end LDO can be bypassed externally to maximize
efficiency. A second LDO is switched in place of the
switching regulator for low current operation to further
improve efficiency and reduce noise.




The SC190’s flexible clocking scheme allows it to be 
synchronized to an external oscillator or controlled by the 
internal oscillator. The 1MHz switching frequency allows 
the use of small inductors and capacitors.

Regulator or Linear Regulator
Dynamic Handover Between Linear and Switching
Regulator for Maximum Efficiency
2.7V to 5.5V Input Range
300mA Guaranteed Output Current
Fixed Frequency 1MHz Operation or 750kHz to
1.5MHz Clocked Operation
No Schottky Diode Required
Up to 95% Efficiency (VIN=BP)
Over-current Protection
Over-voltage Protection
Over-temperature Protection
Soft Start
MLP-10, 3 x 3mm Lead-frame, Lead-free Package
Low Output Noise < 100µVrms
Applications
The internal MOSFET switches provide peak current
greater than 500mA to achieve a DC output of at least
300mA. Shutdown current is typically 0.1µA.



The SC190 has four different variants with four voltage

settings each. It is designed for single-cell Li-ion battery

applications, but also performs well in fixed 3.3V and 5V

applications.
Cell Phones
Cordless Phones
Notebook and Subnotebook Computers
PDAs and Mobile Communicators
WLAN Peripherals
1 Li-Ion or 3 NiMH/NiCd Powered Devices
Typical Application Circuit
VIN
VIN
EN
CIN
4.7µF
SC190
4.7µH
LX
VOUT
SYNC/PWM
COUT
VID0
BP
VID1
GND
MODE
June 30, 2005
VOUT
LOUT
1
CBP
4.7µF
4.7µF
www.semtech.com
SC190
POWER MANAGEMENT
Absolute Maximum Ratings
Exceeding the specifications below may result in permanent damage to the device or device malfunction. Operation outside of the parameters specified in the
Electrical Characteristics section is not implied.
Parameter
Symbol
Maximum
Units
VIN Input
VIN
-0.3 to 7
V
Logic Inputs (SYNC/PWM,
EN, MODE, VID0, and VID1)
VN
-0.3 to 7
V
LX Voltage
VLX
-1 to BP +1
V
VOUT Voltage
VOUT
-0.3 to VIN + 0.3
V
BP Voltage
VBP
VIN -0.3 to VIN + 0.3
V
Thermal Impedance Junction to Ambient
θJA
*31
VOUT Short Circuit to GND
tSC
Continuous
s
BP Current
IBP
0.8
A
LX Current
ILX
+1.2
A
Storage Temperature
TS
-65 to +150
°
Junction Temperature
TJC
+150
°
Peak IR Reflow Temperature
TLEAD
260
°
C/W
°
C
C
C
* Tied to PCB with 1 square inch, 2 ounce copper.
Electrical Characteristics
Unless otherwise noted: VIN = 3.6V, SYNC/PWM = VIN, MODE = GND, EN = VIN, TA = -40 to 85°C. Typical values are at TA = +25°C. This device is ESD sensitive.
Use of standard ESD handling precautions is required.
Parameter
Input Voltage Range
Symbol
VIN
Input Voltage Ripple
VIN PK-PK
Line Regulation
VLINEREG
Load Regulation
P-Channel On Resistance
N-Channel On Resistance
Start Up Time
 2005 Semtech Corp.
Conditions
Min
VIN = VBP
VIN ≠ VBP
Max
Units
2.7
5.5
V
2.9
5.5
V
CIN, CBP = 10µF
Typ
1
mV
190A, B and D: see note (1)
-0.3
0.3
%/V
190C: see note (2)
-0.5
0.5
%/V
VLOADREG
IOUT = 5mA to 300mA
0.002
%/mA
RDSP
ILX = 100mA
0.3
Ω
RDSN
ILX = 100mA
0.2
Ω
TSTART
IOUT = 150mA
1.25
ms
2
www.semtech.com
SC190
POWER MANAGEMENT
Electrical Characteristics (Cont.)
Unless otherwise noted: VIN = 3.6V, SYNC/PWM = VIN, MODE = GND, EN = VIN, TA = -40 to 85°C. Typical values are at TA = +25°C. This device is ESD sensitive.
Use of standard ESD handling precautions is required.
Parameter
VOUT Accuracy
Back-end LDO
Load Regulation (BELDO)
Back-end LDO Line
Regulation (BELDO)
Back-end LDO
Current Limit (BELDO)
Symbol
Max
Units
-3
3
%
MODE = VIN, IOUT = 1mA
3
3
%
IOUT = 150mA, TA = +25°C
-1.5
1.5
%
MODE = VIN, IOUT = 1mA,
TA = +25°C
-1.5
1.5
%
VOUTLOADREG
IOUT= 100µA to 5mA
MODE = VIN
-0.1
0.1
%/mA
VOUTLINEREG
VIN = 2.7V to 5.5V
MODE = VIN
-0.3
0.3
%/V
MODE = VIN
20
40
60
mA
300
325
VOUT
Iout LIMLDO
Conditions
Min
IOUT = 150mA
IBP = 180mA(3)
Typ
mV
Front-end LDO (FELDO)
VBP
P-Channel Current Limit
ILIM(P)
500
630
860
mA
N-Channel Current Limit
ILIM(N
-270
-420
-520
mA
MODE = VIN, IOUT = 100µA(4)
10
15
µA
Quiescent Current
IQ
Shutdown Current
ISD
EN = 0
0.1
1
µA
LX Leakage Current PMOS
ILXP
VIN = 5.5V, LX = 0V, EN = 0
0.1
1
µA
LX Leakage Current NMOS
ILXN
VIN = 5.5V, LX = 5.5V, EN = 0
Output Voltage Noise
en
COUT = 4.7µF, VOUT = 1V,
IOUT = 1mA, 100Hz < f < 100kHz
Oscillator Frequency
fOSC
SYNC Frequency (upper)
fSYNCU
SYNC Frequency (lower)
fSYNCL
 2005 Semtech Corp.
-20
0.87
0.1
µA
93
µVRMS
1.0
1.12
1.5
MHz
750
3
MHz
kHz
www.semtech.com
SC190
POWER MANAGEMENT
Electrical Characteristics (Cont.)
Unless otherwise noted: VIN = 3.6V, SYNC/PWM = VIN, MODE = GND, EN = VIN, TA = -40 to 85°C. Typical values are at TA = +25°C. This device is ESD sensitive.
Use of standard ESD handling precautions is required.
Parameter
UVLO Threshold (lower)
UVLO Hysteresis
Symbol
Conditions
VUVL
Min
Typ
Max
Units
2.4
2.5
2.6
V
VUVLHYS
50
Thermal Shutdown
THI
145
°
Thermal Shutdown
Hysteresis
THYSR
10
°
Logic Input High
VIH
EN, SYNC/PWM, MODE,
VID0, VID1
Logic Input Low
VIL
EN, SYNC/PWM, MODE,
VID0, VID1
Logic Input Current High
IIH
EN, SYNC/PWM, MODE,
VID0, VID1
-2
Logic Input Current Low
IIL
EN, SYNC/PWM, MODE,
VID0, VID1
-2
mV
C
C
1.6
V
0.6
V
0.1
2
µA
0.1
2
µA
Notes:
(1) Line regulation is tested with 2.7V < VIN < 5.5V and the following output voltage settings:
· SC190A - 1.8V
· SC190B - 1.8V
· SC190D - 1.4V
(2) Line regulation is tested with 3.7V < VIN < 5.5V and VOUT = 2.6V for the SC190C version. The input voltage range is reduced due to the
higher output voltage settings of the SC190C. This also forces the specification range to grow wider because it is expressed as a percentage
of the input voltage range.
(3) Tested at IBP = 180mA. Equivalent to IOUT = 300mA at VOUT = 1.8V.
(4) IQ = IIN - IOUT.
 2005 Semtech Corp.
4
www.semtech.com
SC190
POWER MANAGEMENT
Pin Configuration
Ordering Information
Device
Package
SC190AIMLTRT
BP
1
VIN
2
VOUT
3
EN
4
TOP VIEW
10
LX
9
GND
8
VID1
7
VID0
6
SYNC/PWM
SC190BIMLTRT(1)
5
MLP 3X3-10
SC190CIMLTRT(1)
SC190DIMLTRT(1)
SC190AEVB
SC190BEVB
Evaluation Board(2)
SC190CEVB
T
MODE
(1)
SC190DEVB
(1) Lead-free packaging only. This product is fully WEEE and RoHS
compliant. Available on tape and reel only. A reel contains 3000
devices.
(2) Part specific evaluation boards - consult factory for availability.
MLP10: 3X3 10 LEAD
Programmable Output Voltage
VID1
VID0
SC190A
SC190B
SC190C
SC190D
0
0
1.8V
1.2V
2.5V
1.3V
0
1
1.85V
1.5V
2.8V
1.35V
1
0
1.75V
1.0V
2.6V
1.375V
1
1
1.9V
1.8V
2.7V
1.4V
Pin Descriptions
Pin #
Pin Name
1
BP
Regulated output, with respect to VIN, of the front-end LDO. A decoupling capacitor is connected to
this pin. This input goes directly to the internal MOSFET switch.
2
VIN
Input power supply voltage.
3
VOUT
4
EN
Enable (digital input): high input enables the SC190, a low disables and reduces quiescent current to
0.1µA. In shutdown, LX becomes high impedance.
5
MODE
Mode select pin (digital input): MODE = VIN - linear regulator mode; MODE = GND - switcher mode.
6
SYNC/PWM
7
VID0
Logic level Bit 0 used in conjunction with VID1 to set the output voltage.
8
VID1
Logic level Bit 1 used in conjunction with VID0 to set the output voltage.
9
GND
Ground.
10
LX
T
Thermal
 2005 Semtech Corp.
Pin Function
Regulated output voltage and feedback for SC190.
Oscillator synchronization input. Tie to VIN for forced continuous mode or external clock for frequency
synchronization.
Inductor connection to the switching FETs.
Pad for heatsinking purposes. Not connected internally. Connects to ground plane using multiple
vias.
5
www.semtech.com
SC190
POWER MANAGEMENT
Block Diagram
2
VIN
1
BP
REF
LDO
Error
Amp
Front-End
LDO
P Limit
Amp
REF
Current
Amp
SYNC/
PWM
OSC and Slope
Generator
6
10 LX
MODE
PWM
comp
Handover
Timing
5
LDO Error
Amp
Control
Logic
9
500 mV
reference
GND
Error
Amp
VOUT
3
REF
Back-End
LDO
N Limit
Comp
VID0
7
VID1
Voltage
Select
8
EN
4
 2005 Semtech Corp.
6
www.semtech.com
SC190
POWER MANAGEMENT
Applications Information
SC190 Detailed Description
The SC190 is a step-down, pulse-width-modulated (PWM)
DC-DC converter with a low dropout (LDO) pre-regulator
and a low current LDO regulator for operation in low power
modes.
Continuous Conduction & Oscillator Synchronization
The SC190 is designed to operate in continuous conduction
mode thereby maintaining a fixed frequency. When the
SYNC/PWM pin is tied high the part runs under control
of the internal oscillator. The part can be synchronized to
an external clock by driving a clock signal into the SYNC/
PWM pin. The part synchronizes to the rising edge of the
clock.
The device has an internal synchronous rectifier and does
not require a Schottky diode on the LX pin. The device is
designed to operate as a buck converter in PWM mode
with a fixed frequency of 1MHz, but at loads below 5mA,
the part can be operated as an ultra-low current LDO
regulator to minimize supply current.
Back End LDO Mode
The SC190 ultra-low current linear regulator regulates
the same output as the switching regulator. The linear
regulator minimizes the supply current drawn at light
loads consuming only 10µA when supporting a 100µA
load. The SC190 can swap between switching regulator
and linear regulator mode under control of the MODE
pin (see “handover” section). In this way the part either
operates at a fixed frequency or DC output, thereby never
generating load dependant frequencies that are typically
seen with lightly loaded switching regulators.
Programmable Output Voltage
The SC190 has four device variants (SC190A, SC190B,
SC190C, SC190D) each with a distinct range of output
voltages. The output voltage of each variant has four
predetermined values which can be individually selected
by the correct programming of the VID0 and VID1 pins.
(See “Programmable Output Voltage” table on page 5).
Note that the SC190C has much higher output voltage
settings than the other three variants. This device was
intended for use with higher input voltages, so some
performance over the entire input voltage range cannot
be guaranteed.
Handover (Switcher Mode to LDO Regulator Mode, LDO
Regulator Mode to Switcher Mode)
The device can be switched between Switcher mode and
Linear regulator mode and back to Switcher mode without
having to disable and re-enable the part. The output
maintains regulation during the switch over.
Switcher Mode with less than 1mV supply ripple
This is a fixed frequency current mode architecture with
the input supply for the switching regulator pre-regulated
by a front-end LDO regulator. This technique reduces the
supply voltage ripple from 20mV, typically seen from a
switching converter, to approximately 1mV for the SC190.
The supply to the switcher is regulated to the supply
voltage minus approximately 300mV.
Linear Regulator Mode to Switching Mode
Transition
Switching Converter IOUT Specification
Applies
200ìµss
VMODE (Pin 5)
Wait Time
Current feedback for the switching regulator is through
the PMOS current path and it is amplified and summed
with the internal slope compensation network and level
shift. The voltage feedback loop is through an internal
feedback divider. The ON time is determined by comparing the summed current feedback and the output of the
error amplifier. The period is set by the onboard oscillator
or by an external clock attached to the SYNC/PWM pin.
IOUT (Pin 3)
< 5mA
< 300mA
Time
Switching Mode to Linear Regulator Mode
Transition
Linear Regulator IOUT Specification
Applies
Efficiency at moderate to high loads can be improved by
shorting the VIN to BP pins at the expense of higher input
voltage ripple.
100ìµss
VMODE (Pin 5)
Wait Time
IOUT (Pin 3)
< 300mA
< 5mA
Time
 2005 Semtech Corp.
7
www.semtech.com
SC190
POWER MANAGEMENT
Applications Information
Overvoltage Protection
Overvoltage protection is provided on the SC190. In the
event of an overvoltage on the output in switcher mode,
the drive to the PWM stage is disabled and the part will
not resume switching until the output voltage has fallen to
below 2% of the regulation voltage.
The output load in switcher mode has to be reduced to a
load that the LDO regulator can support before switching
between the two modes to minimize output voltage
deviation. The transition from LDO regulator mode to
switcher mode requires the load to be kept at levels the
LDO regulator can support for a given time period after
the MODE pin has been pulled low (see Timing Diagram
on page 7).
Soft-Start
The soft-start mode is enabled after every shutdown cycle
to limit in-rush current. In conjunction with the frequency
foldback this controls the maximum current during the
start-up. The switcher’s PMOS current limit is stepped
from 25%, to 50%, to 75%, and then 100% of its typical
value by the internal oscillator. The oscillator frequency
is stepped by 1/8, 1/4, 1/2 and 1 under the control of 4
output voltage thresholds causing modulation of the softstart timer (see Current Limit description in the Protection
Features section). As soon as the part reaches regulation,
soft-start mode is disabled.
Protection Features
The SC190 provides the following protection features:
•
•
•
•
Thermal Shutdown
Current Limit
Overvoltage Protection
Soft-Start
Thermal Shutdown
The device has a thermal shutdown feature to protect the
device if the junction temperature exceeds 150°C. In
thermal shutdown the PWM drive is disabled tri-stating
the LX output and the front-end LDO is disabled. The
device will not be enabled again until the temperature
reduces by 10°C. If during this time the output falls by
greater than 60% of its regulation voltage a soft start will
be invoked. Thermal shutdown is not active during LDO
mode in order to minimize supply current.
100 Percent Duty Cycle Operation
The SC190C has a 100% duty cycle mode of operation
to allow the switcher to regulate the output at low input
voltage to high output voltage conditions. As the input
supply drops towards the output voltage, the PMOS ontime increases linearly until a point where the PMOS
FET is on for 100% of the time. Once the PMOS is on DC
the output voltage will track the input voltage minus the
voltage drop across the PMOS power device according to
the following relationship:
Current Limit
The part has a number of current limit functions. The Frontend LDO regulator has a current limit set at approximately
500mA, which will protect the FELDO regulator in the
event of a pulsed short circuit.
Vout = Vin – Iout ( Rdsp + Rind )
Vout = Output Voltage
Vin = Input Voltage
Iout = Output current
Rdsp = PMOS switch ON resistance
Rind = Series resistance of the inductor
The PMOS and NMOS power devices of the buck switcher
stage are protected by current limit functions.
In the case of a short to ground on the output, the part
enters frequency foldback mode which causes the
switching frequency to divide by a factor determined by
the output voltage, stopping the inductor current “stair
stepping.”
The back-end LDO regulator has a current limit feature
which will limit the maximum output current during LDO
regulator mode to 50mA.
 2005 Semtech Corp.
8
www.semtech.com
SC190
POWER MANAGEMENT
Applications Information (Cont.)
Output Filter
The SC190 series of synchronous step-down converters
have internal loop compensation. The internal
compensation is designed to work with a certain output
filter corner frequency defined by the equation:
Inductor Selection
As previously stated the value of the inductor should be in
the range 4.7µH to 10µH. The magnitude of the inductor
current ripple is dependant on the inductor value and can
be determined by the following equation:
Vo
Vo 1 − 
Vi 
∆IL = 
L•f
1
fc =
2π L • C
This equation demonstrates the relationship between
VIN,VOUT & IL. The inductor ripple current decreases with
higher inductance & increases with higher VIN or VOUT .
The internal compensation is optimized to operate with
an output filter, L=4.7µH & COUT = 10µF. When selecting
output filter components the LC product should not vary
over a wide range.
To maximize efficiency the inductor should have a low
DCR to minimize the conduction losses. As a minimum
requirement the DC current rating of the inductor should
be equal to the maximum load current plus half of the
inductor current ripple and can be determined by the
following equation:
Table 1: Output Filter combinations
L(µH)
COUT(µF)
4.7
4.7
4.7
10
10
10
ILpk = Iout (max) +
The selection of smaller inductor & capacitor values will
move the corner frequency, having an impact on system
stability. Due to this issue the practical lower limit for the
inductor value is 4.7µH.
∆IL
2
Alternatively, set the inductor saturation current to be
greater than the switch current limit as a maximum
limit. ISAT > PMOS. Final inductor selection will depend
on various design considerations such as efficiency, EMI,
size and cost. Table 2 lists the manufacturers of practical
inductor options.
Table 2 - Recommended Inductors
Part Number
Value
(µH)
DCR (Ω)
Rated
Current (A)
TDK
LDR655312T-4R7W
4.7
0.206
0.9
-
20
6.5 x 5.3 x 1.2
Sumida
CDRH3D16LD
4.7
0.073
0.68
-
30
4 x 4 x 1.8
Taiyo Yuden
LMNP04SB100M
10
0.066
0.9
-
20
5x5x2
Coilcraft
LPS3015
10
0.044
-
0.65
20
3 x 3 x 1.5
Coilcraft
LP06610-103M
10
0.41
-
0.8
20
6.9 x 3.8 x 1.0
Manufacturer
 2005 Semtech Corp.
9
Saturation Tolerance
Current (A)
%
Dimensions
(LxWxH mm)
www.semtech.com
SC190
POWER MANAGEMENT
Applications Information (Cont.)
PCB Layout Considerations
Poor layout can degrade the performance of the DCDC converter and can be a contributory factor in EMI
problems, ground bounce and resistive voltage losses.
Poor regulation and instability can result.
A few simple design rules can be implemented to ensure
good layout:
1. Place the inductor and filter capacitors as close to the
device as possible and use short wide traces between the
power components.
2. Route the output voltage feedback path away from
inductor and LX node to minimize noise and magnetic
interference. Use a ground plane to further reduce noise
interference on sensitive circuit nodes.
Suggested Layout
 2005 Semtech Corp.
10
www.semtech.com
SC190
POWER MANAGEMENT
Applications Information (Cont.)
CIN Selection
The source input current to the SC190 buck converter is
a DC supply current with a triangular ripple riding on it.
To prevent large input voltage ripple a low ESR ceramic
capacitor is required. A minimum value of 4.7µF should
be used for sufficient input voltage filtering and a 10µF
MLCC should be used for optimum input voltage filtering.
Input voltage ripple of approximately 1mV can be achieved
when CIN = 10µF, and the front-end LDO regulator is active
and pre-regulating the input supply to the switching
regulator. (See page 12: Input Voltage Ripple graphs).
COUT Selection
A 10µF ceramic capacitor is recommended for the output
filter capacitor. Output voltage ripple is dominated by the
filter capacitance as shown in the following equation:
Vout _ ripple = ∆IL(ripple ) • Cout (ESR)
Choose an X7R or X5R ceramic dielectric for low ESR and
superior temperature and voltage characteristics. Do not
use Y5V capacitors - their temperature coefficients make
them impractical for this application.
Table 3: Recommended Capacitors
Value
(µF)
Rated Voltage
(VDC)
Type
Case Size
GRM188R60J475KE19D
4.7
6.3
X5R
0603
Murata
GRM188R60G106ME47D
10
4
X5R
0603
TDK
C1608X5ROG106M
10
4
X5R
0603
Manufacturer
Part Number
Murata
 2005 Semtech Corp.
11
www.semtech.com
SC190
POWER MANAGEMENT
Typical Characteristics
NOTE: Conditions: L = 10µH, Cout = 10µF
Input Voltage Ripple (FELDO active)
Input Voltage Ripple (FELDO bypassed)
VIN(AC)
VIN(AC)
LX
LX
IL
IL
Handover Transition Switcher to Linear
Mode
Handover Transition Linear to Switcher
Mode
LX
LX
VOUT(AC)
VOUT(AC)
IL
IL
 2005 Semtech Corp.
12
www.semtech.com
SC190
POWER MANAGEMENT
Typical Characteristics (Cont.)
SC190C Line Regulation (FELDO Bypassed)
SC190C Line Regulation (FELDO Active)
2.9
2.9
2.8
VOUT = 2.8V
IOUT = 0.15A
OUTPUT VOLTAGE (V)
OUTPUT VOLTAGE (V)
2.8
2.7
2.6
2.5
VOUT = 2.5V
IOUT = 0.15A
2.4
3.1
3.5
3.9
4.3
4.7
5.1
2.6
2.5
VOUT = 2.5V
IOUT = 0.15A
2.4
2.3
2.7
VOUT = 2.8V
IOUT = 0.15A
2.7
2.3
5.5
2.7
INPUT VOLTAGE (V)
3.9
4.3
4.7
100
100
90
90
80
80
70
70
60
50
40
Vin = 3.0V
Vin = 3.6V
Vin = 4.2V
30
20
5.5
60
50
40
30
Vin = 3.0V
Vin = 3.6V
Vin = 4.2V
20
10
10
0
0.01
5.1
Efficiency vs Load Current
(FELDO Bypassed) - VOUT = 1.8V
EFFICIENCY (%)
EFFICIENCY (%)
3.5
INPUT VOLTAGE (V)
Efficiency vs Load Current
(FELDO Active) - VOUT = 1.8V
0.1
0
0.01
1
OUTPUT CURRENT (A)
6
3.1
Maximum Input Voltage vs Synchronization
Frequency - VOUT = 1.0V
0.1
1
OUTPUT CURRENT (A)
Output Voltage vs
Synchronization Frequency
0.5
5.5
0.4
4.5
0.3
4
%VOUT(NOM) (v)
INPUT VOLTAGE (V)
5
3.5
3
2.5
2
0.2
0.1
VIN = 3.6V
VOUT = 1.0V
IOUT = 0.15A
0
1.5
1
-0.1
0.5
-0.2
0
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
0.7
1.5
 2005 Semtech Corp.
0.9
1.1
1.3
1.5
FREQUENCY (MHz)
FREQUENCY (MHz)
13
www.semtech.com
SC190
POWER MANAGEMENT
Typical Characteristics (Cont.)
Oscillator Frequency vs Temperature
Quiescent Current vs Temperature
14
1200
OSCILLATOR FREQUENCY (kHz)
QUIESCENT CURRENT (µA)
12
10
8
6
4
Vin = 2.7V
Vin = 3.6V
Vin = 5.5V
2
0
-40
-20
0
20
40
60
80
100
1000
800
600
400
Vin = 2.7V
Vin = 3.6V
200
Vin = 5.5V
0
120
-40
TEMPERATURE (°C)
-20
0
20
40
60
80
100
120
TEMPERATURE (°C)
Input Current vs Output Current
1000
INPUT CURRENT (mA)
100
10
1
Linear Regulator
0.1
Switching Regulator
0.01
0.01
0.1
1
10
100
1000
OUTPUT CURRENT (mA)
 2005 Semtech Corp.
14
www.semtech.com
SC190
POWER MANAGEMENT
Evaluation Board Schematic
VIN
2
TP1
VIN
J1
JUMPER1
1
VIN
R2
1M
R3
1M
R4
1M
R5
1M
TP7
LX NODE
2
4
MODE
TP3
5
SYNC/PWM
TP4
6
VID0
TP5
7
VID1
TP6
8
SC190
VIN
LX
10
1
VOUT
8
7
6
5
TP8
VOUT
sense
2
BP
VID1
GND
VOUT
3
SYNC/PWM
VID0
TP13
VOUT
load
10uH
EN
MODE
L1
C2
10uF
1
9
C3
10uF
11
EN
TP2
U1
pa d
R1
1M
C1
10uF
DIP_SW 1
ON
1 2 3 4
1
2
3
4
TP9
GND
 2005 Semtech Corp.
15
TP10
GND
TP11
GND
TP12
GND
www.semtech.com
SC190
POWER MANAGEMENT
Evaluation Board Gerber Plots
Top Copper
Bottom Copper
Top Silkscreen
 2005 Semtech Corp.
Bottom Silkscreen
16
www.semtech.com
SC190
POWER MANAGEMENT
Outline Drawing - MLP-10 3x3
A
E
DIMENSIONS
INCHES
MILLIMETERS
DIM
MIN NOM MAX MIN NOM MAX
B
A
A1
A2
b
C
D
E
e
L
N
aaa
E
PIN 1
INDICATOR
(LASER MARK)
bbb
A
aaa C
A1
C
1
(.008)
.009
.079
.048
.118
.020 BSC
.012 .016
10
.003
.004
.031
.000
.007
.074
.042
.114
.039
.002
.011
.083
.052
.122
.020
1.00
0.05
(0.20)
0.23 0.30
2.02 2.12
1.21 1.31
3.00 3.10
0.50 BSC
0.30 0.40 0.50
10
0.08
0.10
0.80
0.00
0.18
1.87
1.06
2.90
SEATING
PLANE
C
A2
2
LxN
D
N
e
bxN
bbb
C A B
NOTES:
1.
CONTROLLING DIMENSIONS ARE IN MILLIMETERS (ANGLES IN DEGREES).
2.
COPLANARITY APPLIES TO THE EXPOSED PAD AS WELL AS TERMINALS.
Marking Information
190n
yyww
xxxx
yy = two digit year of manufacture
ww = two digit week of manufacture
xxxx = lot number
"n" can be A, B, C, or D
 2005 Semtech Corp.
17
www.semtech.com
SC190
POWER MANAGEMENT
Land Pattern - MLP-10 3x3
DIMENSIONS
K
DIM
(C)
H
G
C
G
H
K
P
X
Y
Z
Z
Y
X
P
INCHES
(.112)
.075
.055
.087
.020
.012
.037
.150
MILLIMETERS
(2.85)
1.90
1.40
2.20
0.50
0.30
0.95
3.80
NOTES:
1.
THIS LAND PATTERN IS FOR REFERENCE PURPOSES ONLY.
CONSULT YOUR MANUFACTURING GROUP TO ENSURE YOUR
COMPANY'S MANUFACTURING GUIDELINES ARE MET.
Contact Information
Semtech Corporation
Power Management Products Division
200 Flynn Road, Camarillo, CA 93012
Phone: (805) 498-2111 FAX (805)498-3804
 2005 Semtech Corp.
18