Version 1.2 TFS 323.doc VI TELEFILTER Filter Specification 19.12.2002 TFS 323 1/5 Measurement condition Ambient temperature T A: Input power level: Terminating impedances at fc *): 23 °C 0 dBm input: 310 output: 330 // -4,6 pF // -4,5 pF Characteristics Remark: Reference level for the relative attenuation arel of the TFS 323 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss a e The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae . The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the frequency response of the filter in the operating temperature range. Data typ. value ae 10 Nominal frequency Centre frequency at ambient temperature fN fc 323 Pass band Amplitude ripple within PB PB Insertion loss dB tolerance / limit max. 12 dB (reference level) In band ripple 323 MHz MHz - 0,4 dB fN max. 0,5 MHz 0,8 dB 0,1 dB max. 0,5 dB p-p 0,4 dB max. 0,8 dB (in any 112,5 kHz increment within the PB) arel Relative attenuation fN fN ± 3 fN ± 20 MHz MHz ......... fN ± ......... ......... fN ± fN ± 0,5 20 40 MHz MHz MHz Group delay at fN Group delay ripple in PB 35 45 dB dB min. min. 30 40 dB dB 425 ns max. 500 ns 20 ns max. 120 ns 0,5 deg p-p max. 5 deg p-p - max. 23 dBm**) 21 - 0,04 - 40 °C ... + 70 - 40 °C ... + 100 - (in any 112,5 kHz increment within the PB) Phase linearity in PB (in any 112,5 kHz increment within the PB) Input power level Operating temperature range Storage temperature range Turnover temperature To Temperature coefficient of frequency TCf*** °C ppm / K2 °C °C *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is only max.15dBm ***) f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz) generated: checked / approved: VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.2 TFS 323.doc VI TELEFILTER Filter Specification 19.12.2002 TFS 323 2/5 Construction and pin connection (All dimensions in mm) +0.15 5.0 SQ -0.1 7 5 S 323 P51 1 3 Date code Pin 1 Pin 2 Pin 3 Pin 4 50 input input ground package ground Pin 5 Pin 6 Pin 7 Pin 8 date code: M N P ..... output output ground package ground year + week 2000 2001 2002 matching network : LB-IN L1 1 SAW L3 L2 L4 5 L6 6 2 LB-OUT L5 3,4, 7, 8 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.2 TFS 323.doc VI TELEFILTER Filter Specification 19.12.2002 TFS 323 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N 4. Resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: DIN IEC 286 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer Tape (all dimensions in mm) W : 12 ± 0,3 Po : 4 ± 0,1 Do : 1,5 + 0,5 D1 : 1,5 + 0,5 3000 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE D o Po P 2 E A E : 1,75 ± 0,1 F : 7,5 ± 0,1 o F D 13,4 G (min) : 0,75 P2 : 2 ± 0,05 P1 : 8 ± 0,1 1 ± 0,1 B W o G D1(min) : 1,5 Ao : 5,3 ± 0,1 Bo : 5,3 ± 0,1 P 1 COVER TAPE W 2 Reel (all d imensions in mm ): A : W1 W2 (m ax) : N (m in) : C : : 330 12 ,4 + 2 1 8 ,4 50 13 + 0 ,2 / -0 ,5 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right. VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.2 TFS 323.doc VI TELEFILTER Filter Specification 19.12.2002 TFS 323 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Version 1.2 TFS 323.doc VI TELEFILTER Filter Specification TFS 323 19.12.2002 5/5 History Version Reason of Changes Name Date 1.0 - generate specification according to customer requirements Pfeiffer 16.10.2002 1.1 - change limit of insertion loss Pfeiffer 17.10.2002 1.2 - typical values added - terminated impedance added - triple transit suppression removed Pfeiffer 19.12.2002 VI TELEFILTER Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.