Filename: tfs117.doc Version 2.0 VI TELEFILTER 21.03.2003 Filter specification TFS 117 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 288 258 || -22.2 pF || -22.6 pF Characteristics Remark: The reference level for the relative attenuation arel of TFS117 is the minimum of the pass band attenuation amin. This value is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss a e. The given values for the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below, even if the centre frequency f c is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data typ. value Insertion loss (reference level) ae 5,0 Nominal frequency Centre frequency fN 117,4 Pass band ripple within fN ± 90 kHz Relative attenuation a rel dB tolerance / limit max. 8 dB 117,4 MHz - MHz 0,5 dB max. 1 dB 0,5 0,5 dB dB max. max. 1 3 dB dB fN fN ± 90 ... fN ± 90 kHz ... fN ± 200 kHz kHz fN fN fN fN 1,8 6 30 30 MHz ... MHz ... MHz ... MHz ... MHz MHz MHz MHz 30 42 52 52 dB dB dB dB min. min. min. min. 20 35 20 20 dB dB dB dB kHz 800 100 ns ns max. max. 1 1 µs µs - 18 ppm/K ± ± + - fN ± 6 fN ± 30 fN + 200 fN - 115 Group delay at fN Group delay ripple fN ± 90 Temperature coefficient of frequency (TCf) *) - Operating temperature range - - 10 °C ... + 85 °C Storage temperature range - - 40 °C ... + 85 °C Input power level : max. 10 dBm *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz) generated: checked / approved: TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs117.doc Version 2.0 VI TELEFILTER 21.03.2003 Filter specification TFS 117 2/5 Construction and pin connection (All dimensions in mm) 1 2 3 4 5 6 7 8 9 10 TFS 117 R12 Output Ground Ground Ground Ground Input Ground Ground Ground Ground date code 1 year + month N P R ... 2001 2002 2003 3 10 4 9 5 8 50 2 date code 7 6 matching network: L1 L2 6 Input 50 Ohm 1 Output 50 Ohm SAW C1 C2 2,3,4,5,7 8,9,10 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs117.doc Version 2.0 VI TELEFILTER 21.03.2003 Filter specification TFS 117 3/5 Stability characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: plan, 3 plans; 10 Hz to 500 Hz, 0,35 mm or <VIBRATIONACCEL> g respectively, 1 octave per min, 10 cycles per DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 2000 min. 300 mm min. 500 mm min. 300 mm EMBOSSED CARRIER TAPE Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 12,00 ± 0,1 D1(min) : 1,50 Ao : 7,60 ± 0,1 Bo : 9,60 ± 0,1 Ct : 13,5 ± 0,1 Po Do P2 E Ao F D1 13,4 ± 0,1 W Bo G P1 COVER TAPE W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 60 C : 12,8 ± 0,1 A C N W 1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Marking of the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on the right. TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs117.doc Version 2.0 VI TELEFILTER 21.03.2003 Filter specification TFS 117 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 °C - 170 °C 60 sec. - 90 sec. main-heating periods over 200 °C 20 sec. - 25 sec. peak temperature 255 °C ± 5 °C Chip-mount air reflow profile 260 240 220 200 temperature / °C 180 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 time / sec. Table for temperature vs. time during the air reflow process Tolerance of temperatures: ± 5 °C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / °C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / °C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs117.doc VI TELEFILTER Version 2.0 Filter specification 21.03.2003 TFS 117 5/5 History Version Reason of Changes Name Date Steiner 21.03.2003 Filter specification 2.0 - terminating impedances amd typical values added TELEFILTER GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.