Filter specification
TFS57
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *)
Input:
Output:
23
0
°C
dBm
260 Ω || -19,5 pF
260 Ω || -19,5 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 57 is the maximum of the pass band attenuation amax. The maximum of the pass band
attenuation amax is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1,5 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 57.6 MHz without tolerance. The given values for the relative
attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
ae
13,5
-
Nominal frequency
fN
-
Centre frequency
fC
57,6
tolerance / limit
max.
15
-
dB
57,6
MHz
MHz
Pass band
fN
–
10,6
MHz ... fN
+
10,6
MHz
Pass band ripple
Relative attenuation
fN
–
10,6
MHz ... fN
+
10,6
fN
fN
fN
–
+
+
56,6
27,8
192,4
MHz ... fN
MHz ... fN
MHz ... fN
–
+
+
27,8
192,4
942,4
arel
MHz
0,7
dB
max.
1,5
dB
0,7
dB
max.
1,5
dB
55
48
55
dB
dB
dB
min.
min.
min.
45
45
35
dB
dB
dB
ns
max.
110
ns
Group delay ripple within PB
***)
100
Intermodulation IP3
****)
-
min.
30
dBm
1 dB compression point
-
min.
12
dBm
Input power level
-
max.
13
dBm
Temperature coefficient of frequency
TCf **)
Operating temperature range
OTR
Storage temperature range
-72
ppm/K
-
- 25 °C ... + 85 °C
-
- 40 °C ... + 85°C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
***) to be fulfilled in any 5 MHz segment of the passband; measurement condistions are: 5MHz span, 1601 points, 10 x averaging
****) fin1= 56,0 MHz; fin2= 59,2 MHz; Pin= 0 dBm fmeasurement1 = 2* fin1- fin2=52,8 MHz; fmeasurement2 = 2* fin2- fin1=62,4 MHz
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs57.doc
Version 2.2
VI TELEFILTER
18.09.2003
Filter specification
TFS57
2/5
Construction and pin connection
(All dimensions in mm)
TFS57
●
R35
6,8Max.
13,6Max.
1
2,54 ±0,15
2,54 ±0,15
1 2 3 4
2,0Max.
1,5
Date code
12
5
11
6
10 9 8 7
0,8
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Ground
Ground
Output
Output RF-Return
Ground
Ground
Ground
Ground
Input
Input RF-Return
Date code:
N
P
R
...
Year + week
2001
2002
2003
0,1
50 Ω Test circuit
11
5
L2
1, 2, 3, 4, 7, 8, 9, 10, 12
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs57.doc
Version 2.2
VI TELEFILTER
18.09.2003
Filter specification
TFS57
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
1700
min. 300 mm
min. 500 mm
min. 300 mm
EMBOSSED CARRIER TAPE
Tape (all dimensions in mm)
W
: 24,00 +0,30/-0,10
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,10
F
: 11,50 ± 0,10
G(min)
: 0,60
13,4
P2
: 2,00 ± 0,1
P1
: 12,00 ± 0,1
D1(min)
: 1,50
Ao
: 7,10 ± 0,10
Bo
: 13,90 ± 0,10
Ct
: 21,5 ± 0,1
Do
Po
P2
E
Ao
F
D1
± 0,1
W
Bo
G
P1
COVER TAPE
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
: 60
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. Marking
of the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on the right.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs57.doc
Version 2.2
VI TELEFILTER
18.09.2003
Filter specification
TFS57
4/5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
temperature / °C
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs57.doc
VI TELEFILTER
Version 2.2
Filter specification
18.09.2003
TFS57
5/5
History
Version
Reason of Changes
Name
Date
1.0
- new generation
Steiner
17.11.2000
2.0
- extend specification to filter specification
- adjust loss and group delay ripple to the final customer specification
Steiner
29.08.2003
2.1
- intermodulation and compression parameter adjusted to customer requirement
Steiner
05.09.2003
2.2
- package and reel dimensions corrected
- terminating impedance adjusted to final samples
Steiner
18.09.2003
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.