COILCRAFT ML541PYA

7070 POWER INDUCTORS
High-Reliability Power Inductors ML541PYA
■ High temperature materials allow operation in ambient
temperatures up to 155°C
■ Passes vibration testing to 80 G and shock testing to 1000 G
■ High current and very low DCR
■ Soft saturation makes them ideal for VRM/VRD applications.
Core material Composite
Terminations Tin-silver (96.5/3.5) over copper.
Weight 1.9 – 2.1g
Ambient temperature –55°C to +105°C with Irms current, +105°C to
+155°C with derated current
Storage temperature Component: –55°C to +155°C.
Tape and reel packaging: –55°C to +80°C
Resistance to soldering heat Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Enhanced crush-resistant packaging 150 per 7″reel
Plastic tape: 16 mm wide, 0.3 mm thick, 12 mm pocket spacing,
7.21 mm pocket depth
Inductance2
Part number1
±20% (µH)
ML541PYA161MLZ 0.16
ML541PYA301MLZ 0.30
ML541PYA551MLZ 0.55
ML541PYA651MLZ 0.65
ML541PYA801MLZ 0.80
ML541PYA102MLZ 1.0
ML541PYA122MLZ 1.2
ML541PYA182MLZ 1.8
ML541PYA222MLZ 2.2
ML541PYA332MLZ 3.3
ML541PYA472MLZ 4.7
ML541PYA562MLZ 5.6
ML541PYA682MLZ 6.8
Irms (A)6
(mOhms)3 SRF (MHz)4 Isat5
typ max min typ (A) 20°C rise 40°C rise
0.75 0.83 166207 78.0 22.9 27.1
1.06 1.17 108135 55.6 19.6 25.1
1.421.56 718943.017.6 21.8
1.751.93 597440.015.8 19.9
2.082.29 546737.815.6 19.4
2.552.81 516434.815.0 18.8
3.103.41 344331.212.2 16.2
4.054.46 344325.011.9 15.8
5.736.33 283519.6 9.9 13.4
8.569.42 263219.4 8.7 11.3
12.9614.26 212615.2 7.9 10.2
13.6715.03 172113.0 6.4 8.6
17.8419.62 162012.8 5.1 6.9
DCR
Irms Testing
Irms testing was performed on a
0.060″ thick pcb with 4 oz. copper
traces optimized to minimize
additional temperature rise.
Temperature rise is highly
dependent on many factors
including pcb land pattern,
trace size, and proximity to
other components. Therefore
temperature rise should be
verified in application conditions.
1. When ordering, please specify testing code:
ML541PYA682MLZ
Testing:Z =COTS
H =Screening per Coilcraft CP-SA-10001
N
=Screening per Coilcraft CP-SA-10004
2. Inductance tested at 100 kHz, 0.1 Vrms using an Agilent/HP 4192A.
3. DCR measured on a micro-ohmmeter.
4. SRF measured using an Agilent/HP 4395A or equivalent.
5. Typical dc current at which the inductance drops 30% from its value without current.
6. Typical current that causes the specified temperature rise from 25°C ambient.
7. Electrical specifications at 25°C.
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
Document ML856-1 Revised 01/08/13
®
© Coilcraft, Inc. 2013
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
Fax 847-639-1508
Email [email protected]
www.coilcraft-cps.com
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specifications subject to change without notice.
Please check our web site for latest information.
7070 POWER INDUCTORS
ML541PYA Series (7070)
Inductance (µH)
0.24
0.20
0.16
0.16 µH
0.12
0.08
0.04
0
0
10
20
30
40
50
Current (A)
60
70
80
90
Inductance (µH)
0.5
0.4
0.30 µH
0.3
0.2
0.1
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0
10
20
30
Current (A)
40
50
60
Inductance (µH)
0
0.55 µH
0
5
10
15
20
25
30
Current (A)
35
40
45
50
1.0
Inductance (µH)
Inductance (µH)
Inductance (µH)
Inductance (µH)
Inductance (µH)
L vs Current
0.8
0.6
0.65 µH
0.4
0.2
0
0
5
10
15
20
25
30
Current (A)
35
40
45
50
1.2
1.0
0.80 µH
0.8
0.6
0.4
0.2
0
0
5
10
20
25
Current (A)
30
35
40
45
1.6
1.2
0.8
1.0 µH
0.4
0
0
4
8
12
16
20
24
28
32
36
40
24
28
32
36
40
Current (A)
2.0
1.6
1.2
1.2 µH
0.8
0.4
0
0
4
8
12
16
20
Current (A)
2.4
2.0
1.6
1.8 µH
1.2
0.8
0.4
0
0
5
10
15
Current (A)
20
25
30
Document ML856-2 Revised 01/08/13
®
© Coilcraft, Inc. 2013
15
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
Fax 847-639-1508
Email [email protected]
www.coilcraft-cps.com
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specifications subject to change without notice.
Please check our web site for latest information.
7070 POWER INDUCTORS
ML541PYA Series (7070)
Inductance (µH)
Inductance (µH)
3.0
2.4
1.8
2.2 µH
1.2
0.6
0
0
5
10
15
20
Current (A)
25
5.0
Inductance (µH)
Inductance (µH)
Inductance (µH)
L vs Current
4.0
3.3 µH
3.0
2.0
1.0
0
0
5
10
15
20
Current (A)
25
8
6
5.6 µH
4
2
0
0
1
2
3
4
5
6
7
8
9
10
11 12 13 14 15
9
10
11 12 13 14 15
Current (A)
10
8
6
6.8 µH
4
2
0
0
1
2
3
4
5
6
7
8
Current (A)
8
6
4.7 µH
4
2
0
0
2
4
6
8
10
12
Current (A)
14
16
18
20
Document ML856-3 Revised 01/08/13
®
© Coilcraft, Inc. 2013
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
Fax 847-639-1508
Email [email protected]
www.coilcraft-cps.com
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specifications subject to change without notice.
Please check our web site for latest information.
7070 POWER INDUCTORS
ML541PYA Series (7070)
Typical L vs Frequency
0.283 ±0.020
7,2 ±0,5
6.8 µH
4.7 µH
XXX
Inductance (µH)
10
2.2 µH
1.8 µH
0.295 ±0.020
7,5 ±0,5
1.2 µH
1.0 µH
1
0.80 µH
Dash
number
0.65 µH
0.276
max
7,0
0.30 µH
0.1
0.1
100
1
Frequency (MHz)
Irms Derating
A
±0.008 in
Dash
±0,20 mm
number
(in / mm)
-161
0.257 / 6.53
-301
0.257 / 6.53
-551
0.257 / 6.53
-651
0.257 / 6.53
-801
0.257 / 6.53
-102
0.249 / 6.33
-122
0.249 / 6.33
-182
0.241 / 6.13
-222
0.234 / 5.93
-332
0.234 / 5.93
-472
0.226 / 5.73
-562
0.226 / 5.73
-682
0.226 / 5.73
B
(in / mm)
0.281 / 7.13
0.281 / 7.13
0.281 / 7.13
0.281 / 7.13
0.281 / 7.13
0.269 / 6.83
0.269 / 6.83
0.257 / 6.53
0.245 / 6.23
0.245 / 6.23
0.234 / 5.93
0.234 / 5.93
0.234 / 5.93
0.180
4,57
0.057 ±0.004
1,45 ±0,10
A
(see table)
B
(see table)
120
110
0.123 ±0.010
3,12 ±0,25
90
80
inches
Dimensions are in
mm
70
0.064
1,63
Suggested
Land Pattern
60
50
40
25°C
Percent of rated Irms
100
30
20
10
0
-55 -40
-20
0
20
40
60
80
100
120
140 160
Ambient temperature (°C)
Document ML856-4 Revised 01/08/13
®
© Coilcraft, Inc. 2013
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
Fax 847-639-1508
Email [email protected]
www.coilcraft-cps.com
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specifications subject to change without notice.
Please check our web site for latest information.