TI CDC582PAH

CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
D
D
D
D
D
Low Output Skew for Clock-Distribution
and Clock-Generation Applications
Operates at 3.3-V VCC
Distributes Differential LVPECL Clock
Inputs to 12 TTL-Compatible Outputs
Two Select Inputs Configure Up to Nine
Outputs to Operate at One-Half or Double
the Input Frequency
No External RC Network Required
D
D
D
D
D
State-of-the-Art EPIC-ΙΙB  BiCMOS Design
Significantly Reduces Power Dissipation
External Feedback Input (FBIN) Is Used to
Synchronize the Outputs With the Clock
Inputs
Application for Synchronous DRAMs
Distributed VCC and Ground Pins Reduce
Switching Noise
Packaged in 52-Pin Quad Flatpack
GND
SEL1
SEL0
AGND
FBIN
AGND
AVCC
CLKIN
CLKIN
AVCC
OE
TEST
CLR
PAH PACKAGE
(TOP VIEW)
1
52 51 50 49 48 47 46 45 44 43 42 41 40
39
2
38
3
37
4
36
5
35
6
34
7
33
8
32
9
31
10
30
11
29
12
28
13
27
14 15 16 17 18 19 20 21 22 23 24 25 26
VCC
4Y3
GND
VCC
4Y2
GND
VCC
4Y1
GND
GND
VCC
3Y3
GND
GND
2Y2
VCC
GND
2Y3
VCC
GND
GND
3Y1
VCC
GND
3Y2
VCC
GND
1Y1
VCC
GND
1Y2
VCC
GND
1Y3
VCC
GND
GND
2Y1
VCC
description
The CDC582 is a high-performance, low-skew, low-jitter clock driver. It uses a phase-lock loop (PLL) to precisely
align the frequency and phase of the clock output signals to the differential LVPECL clock (CLKIN, CLKIN) input
signals. It is specifically designed to operate at speeds from 50 MHz to 100 MHz or down to 25 MHz on outputs
configured as half-frequency outputs. The CDC582 operates at 3.3-V VCC.
The feedback input (FBIN) synchronizes the frequency of the output clocks with the input clock
(CLKIN, CLKIN) signals. One of the twelve output clocks must be fed back to FBIN for the PLL to maintain
synchronization between the differential CLKIN and CLKIN inputs and the outputs. The output used as feedback
is synchronized to the same frequency as the clock (CLKIN and CLKIN) inputs.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC-ΙΙB is a trademark of Texas Instruments Incorporated.
Copyright  1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
description (continued)
The Y outputs can be configured to switch in phase and at the same frequency as differential clock inputs
(CLKIN and CLKIN). Select (SEL1, SEL0) inputs configure up to nine Y outputs, in banks of three, to operate
at one-half or double the differential clock input frequency, depending upon the feedback configuration
(see Tables 1 and 2). All output signal duty cycles are adjusted to 50% independent of the duty cycle at the input
clocks.
Output-enable (OE) is provided for output control. When OE is high, the outputs are in the low state. When OE
is low, the outputs are active. CLR is negative-edge triggered and can be used to reset the outputs operating
at half frequency. TEST is used for factory testing of the device and can be used to bypass the PLL. TEST should
be strapped to GND for normal operation.
Unlike many products containing a PLL, the CDC582 does not require external RC networks. The loop filter for
the PLL is included on chip, minimizing component count, board space, and cost.
Because it is based on PLL circuitry, the CDC582 requires a stabilization time to achieve phase lock of the
feedback signal to the reference signal. This stabilization time is required following power up and application
of a fixed-frequency, fixed-phase signal at CLKIN and CLKIN, as well as following any changes to the PLL
reference or feedback signal. Such changes occur upon change of SEL1 and SEL0, enabling the PLL via TEST,
and upon enable of all outputs via OE.
The CDC582 is characterized for operation from 0°C to 70°C.
detailed description of output configurations
The voltage-controlled oscillator (VCO) used in the CDC582 has a frequency range of 100 MHz to 200 MHz,
twice the operating frequency range of the CDC582 outputs. The output of the VCO is divided by 2 and by 4
to provide reference frequencies with a 50% duty cycle of one-half and one-fourth the VCO frequency. SEL0
and SEL1 determine which of the two signals are buffered to each bank of device outputs.
One device output must be externally wired to FBIN to complete the PLL. The VCO operates such that the
frequency of this output matches that of the CLKIN/CLKIN signals. In the case that a VCO/2 output is wired to
FBIN, the VCO must operate at twice the CLKIN/CLKIN frequency, resulting in device outputs that operate at
the same or one-half the CLKIN/CLKIN frequency. If a VCO/4 output is wired to FBIN, the device outputs operate
at the same or twice the CLKIN/CLKIN frequency.
output configuration A
Output configuration A is valid when any output configured as a 1× frequency output in Table 1 is fed back to
FBIN. The frequency range for the differential clock input is 50 MHz to 100 MHz when using output configuration
A. Outputs configured as 1/2× outputs operate at half the input clock frequency, while outputs configured as 1×
outputs operate at the same frequency as the differential clock input.
Table 1. Output Configuration A
INPUTS
OUTPUTS
SEL1
SEL0
1/2×
FREQUENCY
1×
FREQUENCY
L
L
None
All
L
H
1Yn
2Yn, 3Yn, 4Yn
H
L
1Yn, 2Yn
3Yn, 4Yn
H
H
1Yn, 2Yn, 3Yn
4Yn
NOTE: n = 1, 2, 3
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
output configuration B
Output configuration B is valid when any output configured as a 1× frequency output in Table 2 is fed back to
FBIN. The frequency range for the differential clock inputs is 25 MHz to 50 MHz when using output configuration
B. Outputs configured as 1× outputs operate at the input clock frequency, while outputs configured as 2× outputs
operate at double the frequency of the differential clock inputs.
Table 2. Output Configuration B
INPUTS
OUTPUTS
SEL1
SEL0
1×
FREQUENCY
2×
FREQUENCY
L
L
All
None
L
H
1Yn
2Yn, 3Yn, 4Yn
H
L
1Yn, 2Yn
3Yn, 4Yn
H
H
1Yn, 2Yn, 3Yn
4Yn
NOTE: n = 1, 2, 3
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
functional block diagram
OE
CLR
FBIN
ÎÎÎÎÎÎÎ
ÁÁÁÁÁÁ
ÁÁÁÁ
B
ÎÎÎÎÎÎÎ
ÁÁÁÁÁÁ
ÁÁÁÁ
ÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎ
Phase-Lock Loop
CLKIN
CLKIN
CLR
B
ÁÁÁÁ
2
2
TEST
SEL0
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ
ÁÁÁÁ
One of Three Identical
Outputs – 1Yn
Select
Logic
SEL1
1Y1 – 1Y3
One of Three Identical
Outputs – 2Yn
2Y1 – 2Y3
One of Three Identical
Outputs – 3Yn
3Y1 – 3Y3
One of Three Identical
Outputs – 4Yn
4Y1 – 4Y3
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
Terminal Functions
TERMINAL
NAME
NO.
I/O
DESCRIPTION
CLKIN
CLKIN
44, 45
I
Clock input. CLKIN and CLKIN are the differential clock signals to be distributed by the CDC582 clock-driver
circuit. These inputs are used to provide the reference signal to the integrated PLL that generates the clock
output signals. CLKIN and CLKIN must have a fixed frequency and fixed phase for the PLL to obtain phase
lock. Once the circuit is powered up and valid CLKIN and CLKIN signals are applied, a stabilization time is
required for the PLL to phase lock the feedback signal to its reference signal.
CLR
40
I
Clear. CLR is used to reset the VCO/4 reference frequency. CLR is negative-edge triggered and should be
strapped to VCC or GND for normal operation.
FBIN
48
I
Feedback input. FBIN provides the feedback signal to the internal PLL. FBIN must be hardwired to one of
the twelve clock outputs to provide frequency and phase lock. The internal PLL adjusts the output clocks
to obtain zero phase delay between the FBIN and the differential clock input (CLKIN and CLKIN).
OE
42
I
Output enable. OE is the output enable for all outputs. When OE is low, all outputs are enabled. When OE
is high, all outputs are driven to the low state. Since the feedback signal for the PLL is taken directly from
an output terminal, placing the outputs in the logic low state interrupts the feedback loop; therefore, when
a high-to-low transition occurs at OE, enabling the output buffers, a stabilization time is required before the
PLL obtains phase lock.
SEL1, SEL0
51, 50
I
Output configuration select. SEL0 and SEL1 select the output configuration for each output bank
(e.g., 1 , 1/2 , or 2 ) (see Tables 1 and 2).
TEST
41
I
TEST is used to bypass the PLL circuitry for factory testing of the device. When TEST is low, all outputs
operate using the PLL circuitry. When TEST is high, the outputs are placed in a test mode that bypasses
the PLL circuitry. TEST should be strapped to GND for normal operation.
1Y1 – 1Y3
2Y1 – 2Y3
3Y1 – 3Y3
2, 5, 8
12, 15, 18
22, 25, 28
O
These outputs are configured by SEL1 and SEL0 to transmit one-half or one-fourth the frequency of the
VCO. The relationship between the input clock frequency and the output frequency is dependent on SEL1
and SEL0 and the frequency of the output being fed back to FBIN. The duty cycle of the Y outputs is
nominally 50% independent of the duty cycle of the input clock signals.
4Y1 – 4Y3
32, 35, 38
O
These outputs transmit one-half the frequency of the VCO. The relationship between the input clock
frequency and the output frequency is dependent on the frequency of the output being fed back to FBIN.
The duty cycle of the Y outputs is nominally 50% independent of the duty cycle of CLKIN.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 4.6 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Voltage range applied to any output in the high state or power-off state, VO (see Note 1) . . . – 0.5 V to 5.5 V
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 20 mA
Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 50 mA
Maximum power dissipationat TA = 55°C (in still air) (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
For more information, refer to the Package Thermal Considerations application note in the ABT Advanced BiCMOS Technology Data
Book, literature number SCBD002.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
recommended operating conditions (see Note 3)
VCC
Supply voltage
VIH
High level input voltage
High-level
VIL
Low level input voltage
Low-level
VI
IOH
Input voltage
IOL
TA
CLKIN, CLKIN
MIN
MAX
3
3.6
UNIT
V
VCC –1.025
2
Other inputs
CLKIN, CLKIN
V
VCC –1.62
0.8
Other inputs
0
V
5.5
V
High-level output current
– 32
mA
Low-level output current
32
mA
70
°C
Operating free-air temperature
0
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VCC = 3 V,
VCC = MIN to MAX†,
II = –18 mA
IOH = – 100 µA
VCC = 3 V,
IOH = – 32 mA
IOL = 100 µA
VOL
VCC = 3 V
II
VCC = 0 or MAX†,
VCC = 3.6 V,
ICC
VCC = 3.6 V,,
VI = VCC or GND
Ci
Co
TA = 25°C
MIN
MAX
TEST CONDITIONS
–1.2
VCC – 0.2
2
0.5
±10
±1
VI = VCC or GND
IO = 0,,
Outputs high
5
Outputs low
5
VI = 3 V or 0
VO = 3 V or 0
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
V
V
0.2
IOL = 32 mA
VI = 3.6 V
UNIT
V
µA
mA
4
pF
8
pF
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
timing requirements over recommended ranges of supply voltage and operating free-air
temperature
fclock
l k
Clock frequency
MIN
MAX
VCO is operating at four times the CLKIN/CLKIN frequency
25
50
VCO is operating at double the CLKIN/CLKIN frequency
50
100
40%
60%
Input clock duty cycle
Stabilization time†
After SEL1, SEL0
50
After OE↓
50
After power up
50
UNIT
MHz
µs
† Time required for the integrated PLL circuit to obtain phase lock of its feedback signal to its reference signal. For phase lock to be obtained, a
fixed-frequency, fixed-phase reference signal must be present at CLKIN. Until phase lock is obtained, the specifications for propagation delay
and skew parameters given in the switching characteristics table are not applicable.
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature, CL = 15 pF (see Note 4 and Figures 1, 2, and 3)
FROM
(INPUT)
PARAMETER
TO
(OUTPUT)
MIN
MAX
Y
45%
55%
Duty cycle
fmax
Jitter(pk-pk)
100
tphase error‡
tsk(o)‡
CLKIN↑
Y↑
CLKIN↑
Y↑
tsk(pr)‡
tr
UNIT
MHz
200
ps
500
ps
Y
0.5
ns
Y
1
ns
1.4
ns
–500
tf
1.4
ns
‡ The propagation delay, tphase error, is dependent on the feedback path from any output to the FBIN. The tphase error, tsk(o), and tsk(pr)
specifications are only valid for equal loading of all outputs.
NOTE 4: The specifications for parameters in this table are applicable only after any appropriate stabilization time has elapsed.
PARAMETER MEASUREMENT INFORMATION
2.4 V
CLKIN
2V
2V
CLKIN
tphase error
From Output
Under Test
CL = 30 pf
(see Note A)
500 Ω
Output
1.6 V
2V
0.8 V
tr
1.5 V
2V
0.8 V
VOH
VOL
tf
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
LOAD CIRCUIT FOR OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. The outputs are measured one at a time with one transition per measurement.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
PARAMETER MEASUREMENT INFORMATION
CLKIN
CLKIN
tphase error 1
Outputs
Operating
at 1/2 CLKIN
Frequency
tphase error 2
tphase error 3
Outputs
Operating
at CLKIN
Frequency
tphase error 4
tphase error 7
tphase error 5
tphase error 8
tphase error 6
tphase error 9
NOTES: A. Output skew, tsk(o), is calculated as the greater of:
– The difference between the fastest and slowest of tphase error n (n = 1, 2, . . . 6)
– The difference between the fastest and slowest of tphase error n (n = 7, 8, 9)
B. Process skew, tsk(pr), is calculated as the greater of:
– The difference between the maximum and minimum tphase error n (n = 1, 2, . . . 6) across multiple devices under identical
operating conditions
– The difference between the maximum and minimum tphase error n (n = 7, 8, 9) across multiple devices under identical
operating conditions
Figure 2. Skew Waveforms and Calculations
8
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC582
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH DIFFERENTIAL LVPECL CLOCK INPUTS
SCAS446B – JULY 1994 – REVISED FEBRUARY 1996
PARAMETER MEASUREMENT INFORMATION
CLKIN
CLKIN
tphase error 10
Outputs
Operating
at CLKIN
Frequency
tphase error 11
tphase error 12
tphase error 13
Outputs
Operating
at 2X CLKIN
Frequency
tphase error 14
tphase error 15
NOTES: A. Output skew, tsk(o), is calculated as the greater of:
– The difference between the fastest and slowest of tphase error n (n = 10, 11, . . . 15)
B. Process skew, tsk(pr), is calculated as the greater of:
– The difference between the maximum and minimum tphase error n (n = 10, 11, . . . 15) across multiple devices under identical
operating conditions
Figure 3. Waveforms for Calculation of tsk(o)
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated