VIPER37 VIPerPlus family: fixed frequency offline converter Features ■ 800 V avalanche rugged power section ■ PWM operation with adjustable limiting current ■ 30 mW standby power at 265 Vac ■ Operating frequency: – 60 kHz for L type – 115 kHz for H type SDIP10 Description ■ Frequency jittering for low EMC ■ Output overvoltage protection ■ High primary current protection (2nd OCP) ■ Input undervoltage setting (brownout) ■ Onboard soft-start ■ Safe auto-restart after a fault condition ■ Hysteretic thermal shutdown This device is an offline converter with an 800 V rugged power section, a PWM control, two levels of overcurrent protection, overvoltage and overload protection, hysteretic thermal protection, soft-start, and safe auto-restart after the removal of any fault condition. Burst mode operation and very low device consumption help to meet the standby energy saving regulations. Advance frequency jittering reduces EMI filter costs. Brownout function protects the switch mode power supply when the rectified input voltage level is below the normal minimum level specified for the system. The high voltage startup circuit is embedded in the device. Applications ■ SMPS for set-top boxes, DVD players and recorders, white goods ■ Auxiliary power supply for consumer and home equipment ■ ATX auxiliary power supply ■ Low / medium power AC-DC adapters Figure 1. Typical topology + + DC input high voltage wide range DC Output voltage DRAIN DRAIN DRAIN DRAIN DRAIN VIPER37 GND Table 1. VDD CONT FB BR Device summary Order codes Package Packaging SDIP10 Tube VIPER37LE VIPER37HE February 2012 Doc ID 022218 Rev 1 1/35 www.st.com 35 Contents VIPER37 Contents 1 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Typical power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 Pin settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.1 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.2 Thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.3 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5 Typical electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6 Typical circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 7 Efficiency performances for a typical flyback converter . . . . . . . . . . . 16 8 Operation description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 2/35 8.1 Power section and gate driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 8.2 High voltage startup generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 8.3 Power-up and soft-start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 8.4 Power down operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 8.5 Auto-restart operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 8.6 Oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 8.7 Current mode conversion with adjustable current limit set point . . . . . . . 22 8.8 Overvoltage protection (OVP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 8.9 About the CONT pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 8.10 Feedback and overload protection (OLP) . . . . . . . . . . . . . . . . . . . . . . . . . 25 8.11 Burst mode operation at no load or very light load . . . . . . . . . . . . . . . . . . 27 8.12 Brownout protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 8.13 2nd level overcurrent protection and hiccup mode . . . . . . . . . . . . . . . . . . 30 Doc ID 022218 Rev 1 VIPER37 Contents 9 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 10 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Doc ID 022218 Rev 1 3/35 Block diagram VIPER37 1 Block diagram Figure 2. Block diagram VDD VDD Vcc BR DRAIN + Vin_OK VBRth Internal Supply bus & Ref erence Voltages SUPPLY & UVLO HV_ON Istart-up 15uA UVLO SOFT START OCP BLOCK - CONT OTP OCP BURST + . OVP LOGIC + THERMAL SHUTDOWN OSCILLATOR PWM TURN-ON LOGIC LEB S Q R1 R2 6uA + OVP 2nd OCP LOGIC Ref OLP OVP OTP Rsense BURST-MODE LOGIC BURST FB GND 2 Typical power Table 2. Typical power 230 VAC Part number VIPER37 85-265 VAC Adapter(1) Open frame(2) Adapter(1) Open frame(2) 23 W 25 W 13 W 15 W 1. Typical continuous power in non-ventilated enclosed adapter measured at 50 ° C ambient. 2. Maximum practical continuous power in an open frame design at 50 ° C ambient, with adequate heatsinking. 4/35 Doc ID 022218 Rev 1 VIPER37 3 Pin settings Pin settings Figure 3. Note: Connection diagram (top view) '.$ $2!). 6$$ $2!). #/.4 $2!). &" $2!). "2 $2!). The copper area for heat dissipation must be designed under the DRAIN pins. Table 3. Pin description Pin n. Name 1 GND This pin represents the device ground and the source of the power section. 2 VDD Supply voltage of the control section. This pin also provides the charging current of the external capacitor during startup time. 3 4 5 6...10 Function Control pin. The following functions can be selected: 1. current limit set point adjustment. The internal set default value of the cycle-bycycle current limit can be reduced by connecting to ground an external resistor. CONT 2. output voltage monitoring. A voltage exceeding the VOVP threshold (see Table 8) shuts the IC down reducing the device consumption. This function is stropped and digitally filtered for high noise immunity. FB Control input for duty cycle control. Internal current generator provides bias current for loop regulation. A voltage below the threshold VFBbm activates the burst mode operation. A level close to the threshold VFBlin means that we are approaching the cycle-by-cycle overcurrent set point. BR Brownout protection input with hysteresis. A voltage below the threshold VBRth shuts down (not latched) the device and lowers the power consumption. Device operation restarts as the voltage exceeds the threshold VBRth + VBRhyst. It can be connected to ground when not used. High voltage drain pin. The built-in high voltage switched startup bias current is DRAIN drawn from this pin too. Pins connected to the metal frame to facilitate heat dissipation. Doc ID 022218 Rev 1 5/35 Electrical data VIPER37 4 Electrical data 4.1 Maximum ratings Table 4. Absolute maximum ratings Value Symbol Parameter Unit Min. Max. VDRAIN Drain-to-source (ground) voltage V EAV Repetitive avalanche energy (limited by TJ = 150 °C) 5 mJ IAR Repetitive avalanche current (limited by TJ = 150 °C) 1.5 A 3 A IDRAIN Pulse drain current VCONT Control input pin voltage -0.3 6 V VFB Feedback voltage -0.3 5.5 V VBR Brownout input pin voltage -0.3 5 V VDD Supply voltage (IDD = 25 mA) -0.3 Self limited V IDD Input current 25 mA Power dissipation at TA < 60 °C 1.5 W PTOT TJ TSTG 4.2 800 Operating junction temperature range -40 150 °C Storage temperature -55 150 °C Thermal data Table 5. Symbol Thermal data Parameter Max. value Unit RthJP Thermal resistance junction pin (Dissipated power = 1 W) 35 ° C/W RthJA Thermal resistance junction ambient (Dissipated power = 1 W) 80 ° C/W RthJA Thermal resistance junction ambient (1) (Dissipated power = 1 W) 65 ° C/W 1. When mounted on a standard single side FR4 board with 150 mm2 (0.155 sq. in.) of Cu (35 µm thick). 6/35 Doc ID 022218 Rev 1 VIPER37 4.3 Electrical data Electrical characteristics (TJ = -25 to 125 °C, VDD = 14 V(a); unless otherwise specified). Table 6. Power section Symbol Parameter VBVDSS IOFF RDS(on) COSS Test condition Min. Breakdown voltage IDRAIN = 1 mA, VFB = GND TJ = 25 °C 800 OFF state drain current VDRAIN = max. rating, VFB = GND, TJ = 25 °C 60 µA IDRAIN = 0.4 A, VFB = 3 V, VBR = GND, TJ = 25 °C 4.5 Ω IDRAIN = 0.4 A, VFB = 3 V, VBR = GND, TJ = 125 °C 9 Ω Drain-source on state resistance Effective (energy related) output capacitance VDRAIN = 0 to 640 V, TJ = 25 °C Typ. Max. Unit V 17 pF a. Adjust VDD above VDDon startup threshold before setting to 14 V. Doc ID 022218 Rev 1 7/35 Electrical data VIPER37 Table 7. Symbol Supply section Parameter Test condition Min. Typ. Max. Unit 60 80 100 V VDRAIN = 120 V, VBR = GND, VFB = GND, VDD = 4 V -2 -3 -4 mA VDRAIN = 120 V, VBR = GND, VFB = GND, VDD = 4 V after fault. -0.4 -0.6 -0.8 mA Operating voltage range After turn-on 8.5 23.5 V VDD clamp voltage IDD = 20 mA 23.5 Voltage VDRAIN_START IDDch VDD VDDclamp Drain-source start voltage Startup charging current VDDon VDD startup threshold VDDoff VDD undervoltage shutdown threshold VDD(RESTART) V 13 14 15 V VBR = GND, VFB = GND 7.5 8 8.5 V VDD restart voltage threshold VDRAIN = 120 V, VBR = GND, VFB = GND 4 4.5 5 V IDD0 Operating supply current, not switching VFB = GND, FSW = 0 kHz, VBR = GND, VDD = 10 V 0.9 mA VDRAIN = 120 V, FSW = 60 kHz 2.5 mA IDD1 Operating supply current, switching VDRAIN = 120 V, FSW = 115 kHz 3.5 mA VDRAIN = 120 V, Current 8/35 IDD_FAULT Operating supply current, with protection tripping VDD = 10 V 400 µA IDD_OFF Operating supply current with VDD < VDD_OFF VDD = 7 V 270 µA Doc ID 022218 Rev 1 VIPER37 Electrical data Table 8. Controller section Symbol Parameter Test condition Min. Typ. Max. Unit Feedback pin VFBolp Overload shutdown threshold 4.5 4.8 5.2 V VFBlin Linear dynamics upper limit 3.2 3.5 3.7 V VFBbm Burst mode threshold Voltage falling 0.6 V VFBbmhys Burst mode hysteresis Voltage rising 100 mV IFB RFB(DYN) HFB Feedback sourced current VFB = 0.3 V -150 3.3 V < VFB < 4.8 V Dynamic resistance VFB < 3.3 V ∆VFB / ∆ID -200 -280 µA µA -3 14 21 kΩ 2 6 V/A CONT pin VCONT_l Low level clamp voltage ICONT = -100 µA VCONT_h High level clamp voltage ICONT = 1 mA 0.5 V 5 5.5 6 V 0.95 1 1.05 A Current limitation IDlim Max. drain current limitation tSS Soft-start time TON_MIN td tLEB ID_BM VFB = 4 V, ICONT = -10 µA TJ = 25 °C 8.5 Minimum turn-on time 220 400 ms 480 ns Propagation delay 100 ns Leading edge blanking 300 ns 160 mA Peak drain current during burst mode VFB = 0.6 V Oscillator section VIPER37L FOSC FD VDD = operating voltage range, VFB = 1 V VIPER37H 54 60 66 kHz 103 115 127 kHz VIPER37L ±4 kHz VIPER37H ±8 kHz 250 Hz Modulation depth FM Modulation frequency DMAX Maximum duty cycle Doc ID 022218 Rev 1 70 80 % 9/35 Electrical data VIPER37 Table 8. Controller section (continued) Symbol Parameter Test condition Min. Typ. Max. Unit Overcurrent protection (2nd OCP) IDMAX Second overcurrent threshold 1.7 A Overvoltage protection VOVP Overvoltage protection threshold TSTROBE Overvoltage protection strobe time 2.7 3 3.3 2.2 V us Brownout protection VBRth Brownout threshold Voltage falling VBRhyst Voltage hysteresis above VBRth Voltage rising IBRhyst Current hysteresis VBRclamp VDIS Clamp voltage 0.41 0.45 50 7 IBR = 250 µA Brownout disable voltage 0.49 mV 12 3 50 V µA V 150 mV Thermal shutdown 10/35 TSD Thermal shutdown temperature THYST Thermal shutdown hysteresis Doc ID 022218 Rev 1 150 160 °C 30 °C VIPER37 Electrical data Figure 4. Minimum turn-on time test circuit V(DRAIN) 14 V GND DRAIN VDD DRAIN CONT DRAIN FB DRAIN BR DRAIN 90 % TONmin 50 Ω 10 % Time I(DRAIN) IDLIM 30 V 3.5 V Time Figure 5. Brownout threshold test circuits 14 V IBRhyst V(BR) GND DRAIN VDD DRAIN VBRth+VBRhyst VBRth CONT DRAIN VDIS FB DRAIN BR DRAIN Time IBRhyst 30 V 2V I(BR) 10 kΩ I(DRAIN) Time Time Figure 6. OVP threshold test circuits GND DRAIN VDD DRAIN CONT DRAIN FB DRAIN BR DRAIN 14 V V(CONT) VOVP 10 kΩ V(DRAIN) Time 30 V 2V Time Note: Adjust VDD above VDDon startup threshold before setting to 14 V. Doc ID 022218 Rev 1 11/35 Typical electrical characteristics VIPER37 5 Typical electrical characteristics Figure 7. Current limit vs. TJ Figure 8. ,'/,0,'/,0#& )26&)26&#& Switching frequency vs. TJ 7->&@ Drain start voltage vs. TJ ".W Figure 10. HFB vs. TJ 9'5$,1B67$579'5$,1B67$57#& +)%+)%#& 7->&@ 7->&@ ".W 12/35 7->&@ ".W Figure 9. Doc ID 022218 Rev 1 ".W VIPER37 Typical electrical characteristics Figure 11. Brownout threshold vs. TJ Figure 12. Brownout hysteresis vs. TJ 9%5WK9%5WK#& 9%5+\VW9%5+\VW#& 7->&@ 7->&@ ".W ".W Figure 13. Brownout hysteresis current vs. TJ Figure 14. Operating supply current (not switching) vs. TJ ,'',''#& ,%5+\VW,%5+\VW#& 7->&@ ".W Doc ID 022218 Rev 1 7->&@ ".W 13/35 Typical electrical characteristics VIPER37 Figure 15. Operating supply current (switching) vs. TJ Figure 16. Current limit vs. RLIM ,'',''#& ,'/,0,'/,0#.2KP 5OLP>N2KP@ 7->&@ ".W Figure 17. Power MOSFET ON resistance vs. TJ ".W Figure 18. Power MOSFET breakdown voltage vs. TJ 9%9'669%9'66#& 5'6215'621#& ".W 14/35 7->&@ 7->&@ Doc ID 022218 Rev 1 ".W VIPER37 Typical electrical characteristics Figure 19. Thermal shutdown 6$$ 6$$ON 6$$OFF 6$$2%34!24 WLPH )$2!). WLPH 4* 43$ 43$ 7+<67 1RUPDORSHUDWLRQ 6KXWGRZQDIWHURYHUWHPSHUDWXUH Doc ID 022218 Rev 1 1RUPDORSHUDWLRQ WLPH 15/35 Typical circuit 6 VIPER37 Typical circuit Figure 20. Min-features flyback application D3 Vout R1 AC IN C2 BR C1 C5 AC IN D1 GND D2 R2 R3 VVcc DD OPTO DRAIN R5 BR CONTROL C3 R4 CONT FB C6 GND SOURCE U2 C4 R6 Figure 21. Full-features flyback application D3 Rh AC IN Vout R1 C2 BR C1 C5 Rl AC IN D1 GND Daux Rov p R2 D2 R3 VVcc DD DRAIN OPTO R5 BR CONTROL C3 R4 CONT FB C6 GND SOURCE U2 Rlim C4 16/35 Doc ID 022218 Rev 1 R6 VIPER37 Efficiency performances for a typical flyback converter The efficiency of the converter has been measured in different load and line voltage conditions. In accordance with the ENERGY STAR® average active mode testing efficiency method, the efficiency measurements have been performed at 25%, 50% and 75% and 100% of the rated output power, at both 115 VAC and 230 VAC. Table 9. Power supply efficiency, VOUT = 5 V, VIN = 115 VAC %Load Iout Vout Pout Pin Efficiency 25% 0.75 5.04 3.78 4.83 78.26% 50% 1.5 5.04 7.56 9.72 77.78% 75% 2.25 5.04 11.34 14.84 76.42% 100% 3 5.04 15.12 20.04 75.45% Average efficiency Table 10. 76.97% Power supply efficiency, VOUT= 5 V, VIN = 230 VAC %Load Iout Vout Pout Pin Efficiency 25% 0.75 5.04 3.78 5.01 75.45% 50% 1.5 5.04 7.56 9.76 77.46% 75% 2.25 5.04 11.34 14.67 77.30% 100% 3 5.03 15.09 19.59 77.03% Average efficiency 76.81% Figure 22. Power supply consumption at light output loads, VOUT=5 V 350 200mW 300 250 Input power [mW] 7 Efficiency performances for a typical flyback converter 200 100mW 150 50mW 100 30mW 50 0 50 100 150 200 250 300 Input voltage [Vac] Doc ID 022218 Rev 1 17/35 Efficiency performances for a typical flyback converter VIPER37 Figure 23. Power supply consumption at no output load, VOUT=5 V 65 60 No brownout With brownout 55 Input power [mW] 50 45 40 35 30 25 20 15 10 50 100 150 200 Input voltage [Vac] 18/35 Doc ID 022218 Rev 1 250 300 VIPER37 8 Operation description Operation description The device is a high-performance low-voltage PWM controller chip with an 800 V avalanche rugged power section. The controller includes: the oscillator with jittering feature, the startup circuits with soft-start feature, the PWM logic, the current limit circuit with adjustable set point, the second overcurrent circuit, the burst mode management, the brownout circuit, the UVLO circuit, the auto-restart circuit, and the thermal protection circuit. The current limit set-point is set by the CONT pin. The burst mode operation guarantees high performance in standby mode and helps to accomplish the energy saving norm. All the fault protections are built in auto-restart mode with very low repetition rate to prevent the IC overheating. 8.1 Power section and gate driver The power section is implemented with an avalanche ruggedness N-channel MOSFET, which guarantees safe operation within the specified energy rating as well as high dv/dt capability. The power section has a BVDSS of 800 V min. and a typical RDS(on) of 4.5 Ω at 25 ° C. The integrated SenseFET structure allows a virtually loss-less current sensing. The gate driver is designed to supply a controlled gate current during both turn-on and turnoff in order to minimize common mode EMI. Under UVLO conditions an internal pull-down circuit holds the gate low in order to ensure that the power section cannot be turned on accidentally. 8.2 High voltage startup generator The HV current generator is supplied through the DRAIN pin and is enabled only if the input bulk capacitor voltage is higher than the VDRAIN_START threshold, 80 VDC (typical). When the HV current generator is ON, the IDDch current (3 mA typical value) is delivered to the capacitor on the VDD pin. In the case of auto-restart mode after a fault event, the IDDch current is reduced to 0.6 mA, in order to have a slow duty cycle during the restart phase. Doc ID 022218 Rev 1 19/35 Operation description 8.3 VIPER37 Power-up and soft-start If the input voltage rises up to the device start threshold VDRAIN_START, the VDD voltage begins to grow due to the IDDch current (see Table 7) coming from the internal high voltage startup circuit. If the VDD voltage reaches the VDDon threshold (see Table 7), the Power MOSFET starts switching and the HV current generator is turned off (see Figure 25). The IC is powered by the energy stored in the capacitor on the VDD pin, CVDD, until the selfsupply circuit (typically an auxiliary winding of the transformer and a steering diode) develops a voltage high enough to sustain the operation. The CVDD capacitor must be sized correctly in order to avoid fast discharge and keep the needed voltage value higher than the VDDoff threshold. In fact, a too low capacitance value could terminate the switching operation before the controller receives any energy from the auxiliary winding. The following formula can be used for the VDD capacitor calculation: Equation 1 I DDch × tSSaux C VDD = ---------------------------------------V DDon – V DDoff The tSSaux is the time needed for the steady-state of the auxiliary voltage. This time is estimated by the applicator according to the output stage configurations (transformer, output capacitances, etc.). During the converter startup time, the drain current limitation is progressively increased to the maximum value. In this way the stress on the secondary diode is considerably reduced. It also helps to prevent transformer saturation. The soft-start time lasts 8.5 ms and the feature is implemented for every attempt of the startup converter or after a fault. 20/35 Doc ID 022218 Rev 1 VIPER37 Operation description Figure 24. IDD current during startup and burst mode 6$$ 6$$ON 6$$OFF T 6&" 6&"OLP 6&"LIN 6&"BMHYS 6&"BM T 6$2!). T )$$ )$$ )$$ T )$$CH M! 34!24 50 "5234-/$% ./2-!,-/$% ./2-!,-/$% Figure 25. Timing diagram: normal power-up and power-down sequences 6). 9,1 9'5$,1B67$57 +9VWDUWXSLVQRPRUHDFWLYDWHG 6$2!).?34! 24 6$$ UHJXODWLRQLVORVWKHUH WLPH 6$$ON 6$$OFF 6$$2%34!24 6$2!). WLPH )$$ WLPH )$$CH M! 0OWERON 1RUPDORSHUDWLRQ Doc ID 022218 Rev 1 0OWEROFF WLPH 21/35 Operation description VIPER37 Figure 26. Timing diagram: soft-start I DRAIN tss IDlim t V FB V FBolp V FBlin t 8.4 Power down operation At converter power down, the system loses regulation as soon as the input voltage is so low that the peak current limitation is reached. The VDD voltage drops and when it falls below the VDDoff threshold (see Table 7) the Power MOSFET is switched OFF, the energy transfers to the IC interrupted and consequently the VDD voltages decrease, Figure 25. Later, if the VIN is lower than VDRAIN_START (see Table 7), the startup sequence is inhibited and the power down completed. This feature is useful to prevent the converter’s restart attempts and ensures monotonic output voltage decay during the system power down. 8.5 Auto-restart operation If, after a converter power down, the VIN is higher than VDRAIN_START, the startup sequence is not inhibited and is activated only when the VDD voltage drops below the VDD(RESTART) threshold (see Table 7). This means that the HV startup current generator restarts the VDD capacitor charging only when the VDD voltage drops below VDD(RESTART). The scenario described above is, for instance, a power down because of a fault condition. After a fault condition, the charging current IDDch is 0.6 mA (typ.) instead of the 3 mA (typ.) of a normal startup converter phase. This feature, together with the low VDD(RESTART) threshold, ensures that, after a fault, the restart attempts of the IC have a very long repetition rate and the converter works safely with extremely low power throughput. Figure 27 shows the IC behavior after a short-circuit event. 22/35 Doc ID 022218 Rev 1 VIPER37 Operation description Figure 27. Timing diagram: behavior after short-circuit 6$$ 6KRUWFLUFXLWRFFXUVKHUH 6$$ON 6$$OFF 6$$2%34!24 6&" WLPH 6&"OLP 6&"LIN 75(3(7,7,21 6$3 WLPH [75(3(7,7,21 )$$ WLPH )$$CH M! WLPH 8.6 Oscillator The switching frequency is internally fixed to 60 kHz or 115 kHz. In both cases the switching frequency is modulated by approximately ±4 kHz (60 kHz version) or ±8 kHz (115 kHz version) at a 250 Hz (typ.) rate, so that the resulting spread-spectrum action distributes the energy of each harmonic of the switching frequency over a number of sideband harmonics having the same energy on the whole but smaller amplitudes. 8.7 Current mode conversion with adjustable current limit set point This device is a current mode converter: the drain current is sensed and converted into voltage that is applied to the non-inverting pin of the PWM comparator. This voltage is compared with the one on the feedback pin through a voltage divider on a cycle-by-cycle basis. The device has a default current limit value, IDlim, that the user can adjust according to the electrical specifications, through the RLIM resistor connected to the CONT pin (see Figure 16). The CONT pin has a minimum current sunk, needed to activate the IDlim adjustment: without RLIM or with high RLIM (i.e. 100 kΩ), the current limit is fixed to the default value (see IDlim, Table 8). Doc ID 022218 Rev 1 23/35 Operation description 8.8 VIPER37 Overvoltage protection (OVP) The device can monitor the converter output voltage. This operation is done by the CONT pin during Power MOSFET OFF-time, when the voltage generated by the auxiliary winding tracks the converter's output voltage, through turn ratio N (see Figure 28). AUX -------------N SEC In order to perform the output voltage monitor, the CONT pin must be connected to the aux. winding through a resistor divider made up of RLIM and ROVP (see Figure 21 or Figure 29). If the voltage applied to the CONT pin exceeds the internal reference VOVP (see Table 8) for four consecutive times, the controller recognizes an overvoltage condition. This special feature uses an internal counter; that is to reduce sensitivity to noise and prevent the latch from being erroneously activated (see Figure 28). The counter is reset every time the OVP signal is not triggered in one oscillator cycle. Referring to Figure 21, the resistors’ divider ratio kOVP is given by: Equation 2 V OVP k OVP = ----------------------------------------------------------------------------------------------------N AUX -------------- ⋅ ( VOUTOVP + V DSEC ) – VDAUX N SEC Equation 3 R LIM k OVP = --------------------------------R LIM + R OVP where: ● VOVP is the OVP threshold (see Table 8) ● VOUT OVP is the converter output voltage value to activate the OVP set by the user ● NAUX is the auxiliary winding turns ● NSEC is the secondary winding turns ● VDSEC is the secondary diode forward voltage ● VDAUX is the auxiliary diode forward voltage ● ROVP together with RLIM make up the output voltage divider. Then, once the RLIM value is fixed, according to the desired IDlim, the ROVP can be calculated by: Equation 4 1 – kOVP R OVP = R LIM × ----------------------k OVP 24/35 Doc ID 022218 Rev 1 VIPER37 Operation description The resistor values are such that the current sourced and sunk by the CONT pin are within the rated capability of the internal clamp. Figure 28. OVP timing diagram VDS t VAUX 0 CONT (pin 4) t VOVP t T STROBE sampling time STROBE t OVP t COUNTER RESET COUNTER STATUS t 0 0 0 →1 0 1 →2 2 →0 0 →1 0 1 →2 2 →3 3 →4 FAULT t NORMAL OPERATION t FEEDBACK LOOP FAILURE About the CONT pin Referring to Figure 29, the features below can be implemented through the CONT pin: 1. Current limit set point 2. Overvoltage protection on the converter output voltage Table 11, referring to Figure 29, lists the external resistance combinations needed to activate one or more of the CONT pin functions. Figure 29. CONT pin configuration D AUX R OVP CONT SOFT START OCP Comparator Current Limit Curr. Lim. BLOCK + 8.9 TEMPORARY DISTURBANCE Auxiliary winding R LIM To PWM Logic OVP DETECTION LOGIC From SenseFET To OVP Protection Doc ID 022218 Rev 1 25/35 Operation description Table 11. VIPER37 CONT pin configurations Function / component RLIM (1) ROVP DAUX IDlim reduction See Figure 16 No No OVP ≥ 80 kΩ See Equation 4 Yes IDlim reduction + OVP See Figure 16 See Equation 4 Yes 1. RLIM must be fixed before ROVP. 8.10 Feedback and overload protection (OLP) The device is a current mode converter: the feedback pin controls the PWM operation, controls the burst mode, and actives the overload protection. Figure 30 and Figure 31 show the internal current mode structure. With the feedback pin voltage between VFBbm and VFBlin, (see Table 8) the drain current is sensed and converted into voltage that is applied to the non-inverting pin of the PWM comparator. This voltage is compared with the one on the feedback pin through a voltage divider on a cycle-by-cycle basis. When these two voltages are equal, the PWM logic orders the switchoff of the Power MOSFET. The drain current is always limited to the IDlim value. In case of overload, the feedback pin increases in reaction to this event and when it goes higher than VFBlin, the PWM comparator is disabled and the drain current is limited to IDlim by the OCP comparator, see Figure 2. When the feedback pin voltage reaches the threshold VFBlin, an internal current generator starts to charge the feedback capacitor (CFB) and when the feedback voltage reaches the VFBolp threshold, the converter is turned off and the startup phase is activated with a reduced value of IDDch to 0.6 mA, see Table 7. During the first startup phase of the converter, after the soft-start time (tSS), the output voltage may force the feedback pin voltage to rise up to the VFBolp threshold that switches off the converter itself. To avoid this event, the appropriate feedback network must be selected according to the output load. Moreover, the feedback network fixes the compensation loop stability. Figure 30 and Figure 31 show the two different feedback networks. The time from the overload detection (VFB = VFBlin) to the device shutdown (VFB = VFBolp) can be set by the CFB value (see Figure 30 and Figure 31), using the formula: Equation 5 V FBolp – V FBlin T OLP – delay = C FB × ---------------------------------------I FB where IFB is the value, reported in Table 8, when the FB voltage is between VFBlin and VFBolp. In Figure 30, the capacitor connected to the FB pin (CFB) is part of the compensation circuit as well as being necessary to activate the overload protection. 26/35 Doc ID 022218 Rev 1 VIPER37 Operation description After the startup time, tSS, during which the feedback voltage is fixed at VFBlin, the output capacitor may not be at its nominal value and the controller interprets this situation as an overload condition. In this case, the OLP delay helps to avoid an incorrect device shutdown during the startup phase. Owing to the above considerations, the OLP delay time must be long enough to bypass the initial output voltage transient and check the overload condition only when the output voltage is in steady-state. The output transient time depends on the value of the output capacitor and on the load. When the value of the CFB capacitor calculated for the loop stability is too low and cannot ensure enough OLP delay, an alternative compensation network can be used, shown in Figure 31. Using this alternative compensation network, two poles (fPFB, fPFB1) and one zero (fZFB) are introduced by the capacitors CFB and CFB1 and the resistor RFB1. The capacitor CFB introduces a pole (fPFB) at a higher frequency than fZB and fPFB1. This pole is usually used to compensate the high frequency zero due to the ESR (equivalent series resistor) of the output capacitance of the flyback converter. The mathematical expressions of these poles and zero frequency, considering the scheme in Figure 31, are reported by the equations below: Equation 6 fZFB = 1 2 ⋅ π ⋅ CFB1 ⋅ RFB1 Equation 7 fPFB = RFB(DYN) + RFB1 2 ⋅ π ⋅ CFB ⋅ RFB(DYN) ⋅ RFB1 ( ) 1 2 ⋅ π ⋅ CFB1 ⋅ RFB1 + RFB(DYN) ) Equation 8 fPFB1 = ( RFB(DYN) is the dynamic resistance seen by the FB pin. The CFB1 capacitor fixes the OLP delay and usually CFB1 results much higher than CFB. Equation 5 can still be used to calculate the OLP delay time but CFB1 must be considered instead of CFB. Using the alternative compensation network, the user can satisfy, in all cases, the loop stability and the correct OLP delay time alike. Doc ID 022218 Rev 1 27/35 Operation description VIPER37 Figure 30. FB pin configuration 1 From sense FET PWM To PWM Logic + PWM CONTROL - Cfb BURST BURST-MODE LOGIC BURST-MODE REFERENCES OLP comparator To disable logic + - 4.8V Figure 31. FB pin configuration 2 From sense FET PWM To PWM Logic + PWM CONTROL - Rfb1 Cfb BURST Cfb1 BURST-MODE REFERENCES BURST-MODE LOGIC OLP comparator + 4.8V 8.11 To disable logic - Burst mode operation at no load or very light load When the load decreases, the feedback loop reacts by lowering the feedback pin voltage. If it falls below the burst mode threshold, VFBbm, the Power MOSFET is no longer allowed to be switched on. After the MOSFET stops, as a result of the feedback reaction to the energy delivery stop, the feedback pin voltage increases and when it exceeds the level, VFBbm + VFBbmhys, the power MOSFET starts switching again. The burst mode thresholds are reported in Table 8 and Figure 32 shows this behavior. Depending on the output load, the power alternates between periods of time in which the Power MOSFET is switching and is enabled, with periods of time when the Power MOSFET is not switching; this working mode is called burst mode. The power delivered to the output during switching periods exceeds the load power demands; the excess of power is balanced from the non-switching period where no power is processed. The advantage of burst mode operation is an average switching frequency much lower then the normal operation working frequency, up to a few hundred hertz, minimizing all frequency related losses. During burst mode the drain current peak is clamped to the level, ID_BM, reported in Table 8. 28/35 Doc ID 022218 Rev 1 VIPER37 Operation description Figure 32. Burst mode timing diagram, light load management 9&203 9)%EP 9)%EPK\V 9)%EP TIME ,'' ,'' ,'' TIME ,'5$,1 ,'B%0 TIME %XUVW0RGH 8.12 Brownout protection Brownout protection is a not-latched shutdown function activated when a condition of mains undervoltage is detected. The brownout comparator is internally referenced to VBRth,Table 8, and disables the PWM if the voltage applied at the BR pin is below this internal reference. Under this condition the Power MOSFET is turned off. Until the brownout condition is present, the VDD voltage continuously oscillates between the VDDon and the UVLO thresholds, as shown in the timing diagram of Figure 33. A voltage hysteresis is present to improve the noise immunity. The switching operation is restarted as the voltage on the pin is above the reference plus the previously mentioned voltage hysteresis, see Figure 5. The brownout comparator is provided also with a current hysteresis, IBRhyst. The user must set the rectified input voltage above which the Power MOSFET starts switching after brownout event, VINon, and the rectified input voltage below which the Power MOSFET is switched off, VINoff. Thanks to the IBRhyst, see Table 8, these two thresholds can be set separately. Doc ID 022218 Rev 1 29/35 Operation description VIPER37 Figure 33. Brownout protection: BR external setting and timing diagram 6). 6).ON 6).OFF 6$2!).?34!24 6"2 6"2TH 9'' 9,1B'& 9',6 6IN?/+ 'LVDEOH 5+ %5 6$$ 5/ 9%5WK & )"2 )"2HYST 9LQB2. 6$$ON 6$$OFF 6$$2%34!24 ,%5K\VW 6$3 6/54 When the VINon and the VINoff levels are fixed, with reference to Figure 33, the following relationships can be established for the calculation of the resistors RH and RL: Equation 9 RL = − VBRhyst IBRhyst + VINon − VINoff − VBRhyst VINoff − VBRth × VBRth IBRhyst Equation 10 RH = VINon − V INoff − V BRhyst I BRhyst × RL + RL V BRhyst I BRhyst For a proper operation of this function, VIN on must be less than the peak voltage at minimum mains and VIN off less than the minimum voltage on the input bulk capacitor at minimum mains and maximum load. The BR pin is a high impedance input connected to high value resistors, it is therefore prone to pick up noise, which might alter the OFF threshold when the converter operates or creates an undesired switch-off of the device during ESD tests. It is possible to bypass the pin to ground with a small film capacitor (e.g. 1-10 nF) to prevent any malfunctioning of this kind. If the brownout function is not used, the BR pin must be connected to GND, ensuring that the voltage is lower than the minimum VDIS threshold (50 mV), see Table 8. 30/35 Doc ID 022218 Rev 1 VIPER37 Operation description In order to enable the brownout function, the BR pin voltage must be higher than the maximum VDIS threshold (150 mV), see Table 8. 8.13 2nd level overcurrent protection and hiccup mode The device is protected against short-circuit of the secondary rectifier, short-circuit on the secondary winding, or a hard-saturation of the flyback transformer. Such an anomalous condition is invoked when the drain current exceeds the threshold IDMAX (see Table 8). To distinguish a real malfunction from a disturbance (e.g. induced during ESD tests) a “warning state” is entered after the first signal trip. If, in the subsequent switching cycle, the signal is not tripped, a temporary disturbance is assumed and the protection logic is reset in its idle state; otherwise, if the IDMAX threshold is exceeded for two consecutive switching cycles, a real malfunction is assumed and the Power MOSFET is turned off. The shutdown condition is latched as long as the device is supplied. While it is disabled, no energy is transferred from the auxiliary winding; hence the voltage on the VDD capacitor decays to the VDD undervoltage threshold (VDDoff), which clears the latch. The startup HV current generator is still off, until the VDD voltage goes below its restart voltage, VDD(RESTART). After this condition the VDD capacitor is charged again by a 600 µA current, and the converter switching restarts if the VDDon occurs. If the fault condition is not removed the device enters auto-restart mode. This behavior results in a low-frequency intermittent operation (hiccup-mode operation), with very low stress on the power circuit. See the timing diagram of Figure 34. Figure 34. Timing diagram: hiccup-mode OCP Secondary diode short circuit VDD VDDon VDDoff VDD(RESTART) IDRAIN time IDMAX time VDRAIN time Normal operation Hiccup-mode Doc ID 022218 Rev 1 31/35 Package mechanical data 9 VIPER37 Package mechanical data In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK specifications, grade definitions and product status are available at: www.st.com. ECOPACK is an ST trademark. Table 12. SDIP10 mechanical data mm Dim. Min. Typ. A 5.33 A1 0.38 A2 2.92 4.95 b 0.36 0.56 b2 0.51 1.15 c 0.2 0.36 D 9.02 10.16 E 7.62 8.26 E1 6.1 7.11 E2 7.62 E3 10.92 e L 32/35 Max. 1.77 2.92 Doc ID 022218 Rev 1 3.81 VIPER37 Package mechanical data Figure 35. SDIP10 mechanical drawing Doc ID 022218 Rev 1 33/35 Revision history 10 VIPER37 Revision history Table 13. 34/35 Document revision history Date Revision 17-Feb-2012 1 Changes Initial release Doc ID 022218 Rev 1 VIPER37 Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST’s terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST’S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ST REPRESENTATIVES, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER’S OWN RISK. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. © 2012 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com Doc ID 022218 Rev 1 35/35