VECTRON TFS468G

Filename: tfs 468g.doc
Version 1.1
VI TELEFILTER
27.06.2006
Filter specification
TFS 468G
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
490 Ω || -4,3 pF
680 Ω || -4,2 pF
Characteristics
Remark:
The nominal frequency fN is fixed at 468,0 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 468G is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the
dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
typ. value
ae = amin
Insertion loss
(reference level)
fN
fN
±
4,5
… fN
MHz … fN
±
±
fN ±
7
MHz … fN ±
12
MHz … fN ±
fN ±
20
MHz … fN ±
fN ±
438
MHz … fN fN 30
MHz … fN +
fN +
Absolute group delay wihhin PB
4,5
5
12
20
30
30
532
dB
MHz
PB
-
fN ± 4,5
MHz
arel
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Return loss within PB
0,5
dB
max.
1,0
dB
0,5
2,1
dB
dB
max.
max.
1
2,5
dB
dB
22
40
48
54
55
0,47
dB
dB
dB
dB
dB
µs
min.
min.
min.
min.
min.
max.
15
35
40
50
50
3,0
dB
dB
dB
dB
dB
µs
120
ns
max.
250
ns
12
dB
min.
8
dB
max.
15
-
Input power level
OTR
Storage temperature range
Temperature coefficient of frequency
14,0
468,0
Group delay ripple within fN ± 5 MHz
Operating temperature range
max.
-
Pass band ripple
Relative attenuation
dB
fN
Nominal frequency
Passband
10,2
tolerance / limit
TCf **
-
- 40 °C ... + 85°C
-
- 45 °C ... + 85°C
-18
dBm
ppm/K
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
Version 1.1
VI TELEFILTER
27.06.2006
Filter specification
TFS 468G
2/5
0
2.33
-1
2.12
-16
-2
1.91
-24
-3
1.7
-32
-4
1.49
-5
1.28
-6
1.07
-56
-7
0.86
-64
-8
0.65
-72
-9
0.44
-40
-48
-80
5
105
205
305
405
505
605
frequency in MHz
705
805
905
1005
-10
462
463.2
464.4
465.6
466.8
468
469.2
frequency in MHz
470.4
471.6
472.8
delay in µs
0
-8
magnitude in dB
magnitude in dB
Filter characteristic
0.23
474
Construction and pin connection
(All dimensions in mm)
9
S 468G
●
U26
1
4
3
Date code
0,6
2,54
1
1
5 ,0 +/-0,2
12
6
1,8 +/-0,2
10
7
1
2
3
4
5
6
7
8
9
10
11
12
Ground
Ground
Ground
Output
Ground
Output RF Return
Ground
Ground
Ground
Input
Ground
Input RF Return
Date code:
U
V
W
...
Year + week
2006
2007
2008
2,54
7 ,0 +/-0,2
50 Ω Test circuit
10
L1
4
L3
SAW
C1
L2
12
6
L4
C2
1, 2, 3, 5, 7, 8, 9, 11
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
Version 1.1
VI TELEFILTER
27.06.2006
Filter specification
TFS 468G
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 16,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 7,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,50 ± 0,1
Bo
: 7,50 ± 0,1
Ct
: 13,5 ± 0,1
t
P1
Date Code
Po
P2
W
G
Ct
Bo
F
G
E
Do
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 16,4 +2/-0
W2(max) : 22,4
N(min)
: 50
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
Version 1.1
VI TELEFILTER
27.06.2006
Filter specification
TFS 468G
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 468g.doc
VI TELEFILTER
Version 1.1
Filter specification
27.06.2006
TFS 468G
5/5
History
Version
Reason of Changes
Name
Date
1.0
- specification gerated
Pfeiffer
29.03.2006
1.1
- terminating impedance corrected
Pfeiffer
27.06.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.