Filename: tfs 468g.doc Version 1.1 VI TELEFILTER 27.06.2006 Filter specification TFS 468G 1/5 Measurement condition Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 °C dBm 490 Ω || -4,3 pF 680 Ω || -4,2 pF Characteristics Remark: The nominal frequency fN is fixed at 468,0 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative attenuation arel of the TFS 468G is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range. Data typ. value ae = amin Insertion loss (reference level) fN fN ± 4,5 … fN MHz … fN ± ± fN ± 7 MHz … fN ± 12 MHz … fN ± fN ± 20 MHz … fN ± fN ± 438 MHz … fN fN 30 MHz … fN + fN + Absolute group delay wihhin PB 4,5 5 12 20 30 30 532 dB MHz PB - fN ± 4,5 MHz arel MHz MHz MHz MHz MHz MHz MHz Return loss within PB 0,5 dB max. 1,0 dB 0,5 2,1 dB dB max. max. 1 2,5 dB dB 22 40 48 54 55 0,47 dB dB dB dB dB µs min. min. min. min. min. max. 15 35 40 50 50 3,0 dB dB dB dB dB µs 120 ns max. 250 ns 12 dB min. 8 dB max. 15 - Input power level OTR Storage temperature range Temperature coefficient of frequency 14,0 468,0 Group delay ripple within fN ± 5 MHz Operating temperature range max. - Pass band ripple Relative attenuation dB fN Nominal frequency Passband 10,2 tolerance / limit TCf ** - - 40 °C ... + 85°C - - 45 °C ... + 85°C -18 dBm ppm/K *) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz). Generated: Checked / Approved: Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468g.doc Version 1.1 VI TELEFILTER 27.06.2006 Filter specification TFS 468G 2/5 0 2.33 -1 2.12 -16 -2 1.91 -24 -3 1.7 -32 -4 1.49 -5 1.28 -6 1.07 -56 -7 0.86 -64 -8 0.65 -72 -9 0.44 -40 -48 -80 5 105 205 305 405 505 605 frequency in MHz 705 805 905 1005 -10 462 463.2 464.4 465.6 466.8 468 469.2 frequency in MHz 470.4 471.6 472.8 delay in µs 0 -8 magnitude in dB magnitude in dB Filter characteristic 0.23 474 Construction and pin connection (All dimensions in mm) 9 S 468G ● U26 1 4 3 Date code 0,6 2,54 1 1 5 ,0 +/-0,2 12 6 1,8 +/-0,2 10 7 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Output Ground Output RF Return Ground Ground Ground Input Ground Input RF Return Date code: U V W ... Year + week 2006 2007 2008 2,54 7 ,0 +/-0,2 50 Ω Test circuit 10 L1 4 L3 SAW C1 L2 12 6 L4 C2 1, 2, 3, 5, 7, 8, 9, 11 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468g.doc Version 1.1 VI TELEFILTER 27.06.2006 Filter specification TFS 468G 3/5 Stability characteristics, reliability After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 2. Vibration: 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 3. Change of temperature: 4. Resistance to solder heat (reflow): -55 °C to 125°C / 30 min. each / 10 cycles DIN IEC 68 part 2 – 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; This filter is RoHS compliant (2002/95/EG, 2005/618/EG) Packing Tape & Reel: IEC 286 – 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer: 3000 min. 300 mm min. 500 mm min. 300 mm Pull Off Direction Tape (all dimensions in mm) W : 16,00 ± 0,3 Po : 4,00 ± 0,1 Do : 1,50 +0,1/-0 E : 1,75 ± 0,1 F : 7,50 ± 0,1 G(min) : 0,60 P2 : 2,00 ± 0,1 P1 : 8,00 ± 0,1 D1(min) : 1,50 Ao : 5,50 ± 0,1 Bo : 7,50 ± 0,1 Ct : 13,5 ± 0,1 t P1 Date Code Po P2 W G Ct Bo F G E Do Ko Typ PIN Marker D1 Ao W 2 Reel (all dimensions in mm) A : 330 W1 : 16,4 +2/-0 W2(max) : 22,4 N(min) : 50 C : 13,0 +0,5/-0,2 A C N W 1 The minimum bending radius is 45 mm. Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468g.doc Version 1.1 VI TELEFILTER 27.06.2006 Filter specification TFS 468G 4/5 Air reflow temperature conditions Conditions Average ramp-up rate (30°C to 217°C) > 100°C > 150°C > 217°C Peak temperature Time within 5°C of actual peak temperature Cool-down rate (Peak to 50°C) Time from 30°C to Peak temperature Exposure less than 3°C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260°C between 10 and 30 seconds less than 6°C/second no greater than 300 seconds Chip-mount air reflow profile Temperature / °C max. 260°C 217°C max. 300 s 10 ... 30 s Time / s 30 ... 150 s Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. Filename: tfs 468g.doc VI TELEFILTER Version 1.1 Filter specification 27.06.2006 TFS 468G 5/5 History Version Reason of Changes Name Date 1.0 - specification gerated Pfeiffer 29.03.2006 1.1 - terminating impedance corrected Pfeiffer 27.06.2006 Tele Filter GmbH Potsdamer Straße 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: [email protected] VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.