TFS86A

Filename: tfs 86a.doc
Version 1.4
VI TELEFILTER
22.03.2007
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
850
850
|| -2 pF
|| -2 pF
TFS 86A
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of TFS 86A is the minimum of the pass band attenuation amin. This minimum is defined as the insertion
loss ae. The nominal frequency fN is fixed at 86,85 MHz without any tolerance. The given values for the relative attenuation arel and the group delay ripple
have to be reached at the frequencies given below, even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the
operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
Insertion loss
(Reference level)
ae = amin
2,7
Nominal frequency
fN
-
Pass band
PB
tolerance / limit
dB
86,85
fN ± 13
-
Pass band ripple
max. 4
1,0
dB
1,5
dB
MHz
kHz
max.
1,5
Relative attenuation
arel
fN
... fN ± 15
fN ± 60 kHz ... fN ± 120
kHz
dB
max.
3
dB
kHz
26
dB
min.
20
dB
fN + 120 kHz
... fN + 150
kHz
58
dB
min.
40
dB
fN + 150 kHz
... fN + 400
... fN + 1000
kHz
59
dB
min.
30
dB
kHz
60
dB
min.
40
dB
fN - 1000 kHz ... fN - 940
fN - 940 kHz ... fN - 880
kHz
71
dB
min.
50
dB
kHz
71
dB
min.
70
dB
fN - 880 kHz ... fN - 400
fN - 400 kHz ... fN - 120
kHz
63
dB
min.
50
dB
kHz
55
dB
min.
40
dB
Group delay ripple in fN ± 11
kHz
5
µs
max.
10
µs
fN + 400 kHz
Intermodulation
Intermodulation in the composite signal by
fN ± 60 kHz and fN ± 120 kHz each of -20 dBm
-
max. -90
dBm
Operating temperature range
- 20 °C ... + 70
°C
Storage temperature range
- 40 °C ... + 85
°C
Temperature coefficient of frequency
Frequency inversion temperature
TC
dB
- 0,036 ppm/K²
25
°C
No DC voltage permitted
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 86a.doc
Version 1.4
VI TELEFILTER
22.03.2007
Filter specification
TFS 86A
2/5
Filter characteristic
0
0
-10
-1
-30
magnitude in dB
magnitude in dB
-20
-40
-50
-60
-70
-80
-2
-3
-4
-90
-100
86
86.18 86.36 86.54 86.72 86.9 87.08 87.26 87.44 87.62 87.8
frequency in MHz
-5
86.83
86.84
86.85 86.86 86.87
frequency in MHz
86.88
86.89
Construction and pin connection
(All dimensions in mm)
TFS 86A
V12
Date code
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Output
Output RF Return
Ground
Ground
Ground
Input
Input RF Return
Date code:
V
W
X
...
Year + week
2007
2008
2009
Base material ceramic; plating Au 0,75µm over Ni 1,27µm … 8,89µm
50
Test circuit
9
L1
C1
4
L2
SAW
C2
1, 2, 3, 5, 6, 7, 8, 10
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 86a.doc
Version 1.4
VI TELEFILTER
22.03.2007
Filter specification
TFS 86A
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
3000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
Tape (all dimensions in mm)
W
: 24,00 ± 0,3
Po
: 4,00 ± 0,1
Do
: 1,50 +0,1/-0
E
: 1,75 ± 0,1
F
: 11,50 ± 0,1
G(min)
: 0,60
P2
: 2,00 ± 0,1
P1
: 8,00 ± 0,1
D1(min)
: 1,50
Ao
: 5,60 ± 0,1
Bo
: 11,80 ± 0,1
Ct
: 21,5 ± 0,1
P1
Date Code
Po
Do
P2
W
G
Ct
Bo
F
G
E
t
Ko
Typ
PIN Marker
D1
Ao
W 2
Reel (all dimensions in mm)
A
: 330
W1
: 24,4 +2/-0
W2(max) : 30,4
N(min)
: 60
C
: 13,0 +0,5/-0,2
A
C
N
W 1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 86a.doc
Version 1.4
VI TELEFILTER
22.03.2007
Filter specification
TFS 86A
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max.
260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 86a.doc
VI TELEFILTER
Version 1.4
Filter specification
22.03.2007
TFS 86A
5/5
History
Version
Reason of Changes
Name
Date
1.2
changing DC voltage
changing label
Pfeiffer
13.02.2002
1.3
changing of construction
M.Springfeldt
13.05.2004
1.4
reworked construction
reworked matching circuit
reworked air reflow temperature conditions
added plating information
added filter characteristic
added typical values
added RoHS information
Martens
22.03.2007
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.