VECTRON TFS75F

Filename: tfs 75f.doc
Version 1.1
VI TELEFILTER
26.04.2005
Filter specification
TFS 75F
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
0
°C
dBm
50 Ω || 0 pF
50 Ω || 0 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of TFS 75F is the minimum of the pass band attenuation amin. This value is defined as the insertion loss
ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss
ae. The given values for the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below, even if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the
centre frequency fc.
Data
typ. value
Insertion loss
(reference level)
Centre frequency at temperature 70°C
ae
22,8
dB
max.
26,0
dB
fCOT
75,3
MHz
75,3
± 0,10
MHz
Centre frequency at ambient temperature
fC
75,6
MHz
Relative frequency distance of fC within one set of 3 filters at 70 °C
st
65,9 ±0,1 MHz
9,4
MHz
max.
± 20
kHz
nd
87,1 ±0,1 MHz
11,8
MHz
max.
± 20
kHz
fC … fC ± 2,8
MHz
0,7
dB
max.
1
dB
5,98
6,11
6,55
MHz
MHz
MHz
min.
min.
max.
5,6
6,0
6,6
MHz
MHz
MHz
0,7
1,5
dB
dB
max.
max.
1
3
dB
dB
min.
40
dB
min.
45
dB
min.
min.
50
50
dB
dB
µs
max.
5
µs
ns
max.
300
ppm/K
- 25 °C ... + 80
- 40 °C ... + 85
-
1 (TFS65 at 23°C )
2 (TFS87E at 23°C )
PB
Passband
-
Pass band ripple (p-p)
Bandwidth
1
3
40
dB
dB
dB
arel
Relative attenuation
fC
fC
±
2,8
... fC
MHz ... fC
±
±
2,8
3,0
MHz
MHz
3,3
MHz
48
dB
fC ±
in the frequency range fC ± 3,3 MHz … fC ± 20 MHz the limit line is of type SLOPING LINE
fC ±
20
MHz
55
dB
in the frequency range fC ± 20 MHz … fC ± 25 MHz the limit line is of type SLOPING LINE
25
MHz
60
dB
fC ±
25
MHz ... fC ±
50
MHz
60
dB
fC ±
Group delay
mean value in PB
160
Group delay ripple (p-p) in fC … fC + 3 MHz
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
4,75
OTR
TCf **)
-84
ns
°C
°C
*) The terminating impedances depend on parasites and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 75f.doc
Version 1.1
VI TELEFILTER
26.04.2005
Filter specification
TFS 75F
2/5
0
7.36
-8
-1
7.06
-16
-2
6.76
-24
-3
6.46
-4
6.16
-5
5.86
-32
-40
-6
5.56
-56
-7
5.26
-64
-8
4.96
-9
4.66
-48
-72
-80
66.6
68.4
70.2
72
73.8 75.6 77.4
frequency in MHz
79.2
81
82.8
84.6
-10
72.6 73.2
73.8 74.4
75 75.6 76.2
frequency in MHz
76.8 77.4
78
delay in µs
0
magnitude in dB
magnitude in dB
Filter characteristic
4.36
78.6
Construction and pin connection
(All dimensions in mm)
38,10 mm
TFS
75F
T18
Date-code
4
6
17
15
12
14
26
28
Input
Input RF Return
Output
Output RF Return
Ground
Ground
Ground
Ground
Date code:
T
U
V
...
Year + week
2005
2006
2007
5,0 Max.
5,0 ± 0,5
5,08
3,81
4
6
12 14
20,32
28 26
17 15
22,86
33,02
50 Ohm Test circuit
L1
4
17
L2
SAW
6
15
12, 14, 26, 28
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 75f.doc
Version 1.1
VI TELEFILTER
Filter specification
26.04.2005
TFS 75F
3/5
Stability characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 75f.doc
Version 1.1
VI TELEFILTER
26.04.2005
Filter specification
TFS 75F
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 75f.doc
VI TELEFILTER
Version 1.1
Filter specification
26.04.2005
TFS 75F
5/5
History
Version
Reason of changes
Name
Date
1.0.
Generation of development specification
Strehl
27.01.2005
1.1
- terminating impedance, typical values and filter characteristic added
- matching configuration changed
Pfeiffer
26.04.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.