VECTRON TFS70H312

Filename: tfs 70h312.doc
Version 1.1
30.10.2006
VI TELEFILTER
Filter specification
TFS 70H312
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
25.
0
°C
dBm
50 Ω || 0 pF
50 Ω || 0 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 70H312 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB
filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the
production tolerance scheme.
Data
typ. value
Insertion loss
(reference level)
ae
24,6
dB
Centre frequency
fC
70,0
MHz
-
Passband
dB
16,8
26
dB
70,0 ± 0,1 MHz
fc
± 7,5
MHz
MHz
min.
16
MHz
arel
Relative attenuation
fC
max.
BW
Bandwidth
3
tolerance / limit
… fC
±
fC ±
7,5
MHz … fC ±
10,45 MHz … fC ±
fC ±
15
MHz … fC +
fC +
Group delay ripple within PB (p-p)
7,5
8
15
60
MHz
0,7
dB
max.
1
dB
MHz
MHz
MHz
1,8
47
53
20
dB
dB
dB
ns
max.
min.
min.
max.
3
40
50
50
dB
dB
dB
ns
°
max.
4
1,1
Deviation from linear phase within PB
Operating temperature range
OTR
Storage temperature range
Temperature coefficient of frequency
TCf **
-
- 25 °C ... + 80 °C
-
- 40 °C ... + 85 °C
-75
ppm/K
°
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h312.doc
Version 1.1
30.10.2006
VI TELEFILTER
Filter specification
TFS 70H312
2/5
0
1.672
-1
1.624
-14
-2
1.576
-21
-3
1.528
-28
-4
1.48
-5
1.432
-6
1.384
-49
-7
1.336
-56
-8
1.288
-63
-9
1.24
-35
-42
-70
30
38
46
54
62
70
frequency in MHz
78
86
94
102
-10
61
110
62.8
64.6
66.4
68.2
70
71.8
frequency in MHz
73.6
75.4
77.2
delay in µs
0
-7
magnitude in dB
magnitude in dB
Filter characteristic
1.192
79
Construction and pin connection
(All dimensions in mm)
TFS 70H312
●
U44
13 Max.
22,5 Max.
Date code
1
2
7
8
9
14
Input RF Return
Ground
Output RF Return
Output
Ground
Input
Date code:
U
V
W
...
Year + week
2006
2007
2008
7
1
6 Max.
4,5 Min.
7,62+/-0,2
5 Max.
1Dia.0,45+/-0,05
10,16+/-0,2
14 15,24+/-0,2 8
50 Ohm Test circuit
L1
14
1
8
SAW
L2
7
2, 9
Stability characteristics, reliability
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h312.doc
Version 1.1
VI TELEFILTER
Filter specification
30.10.2006
TFS 70H312
3/5
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
4. Resistance to
solder heat (reflow):
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h312.doc
Version 1.1
30.10.2006
VI TELEFILTER
Filter specification
TFS 70H312
4/5
Air reflow temperature conditions
Conditions
Average ramp-up rate (30°C to 217°C)
> 100°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
Exposure
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
max. 300 s
10 ... 30 s
Time / s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 70h312.doc
Version 1.1
VI TELEFILTER
Filter specification
30.10.2006
TFS 70H312
5/5
History
Version
Reason of changes
Name
Date
1.0
- Generate development specification .
Tino Braun
23.04.2003
1.1
- add of typical values and filter characteristics
- stability characteristics and air reflow temperaturte conditionsmodified
Pfeiffer
30.10.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.