TI SN74ALS652ADW

SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
D
D
D
D
Bus Transceivers/Registers
Independent Registers and Enables for A
and B Buses
Multiplexed Real-Time and Stored Data
Choice of True or Inverting Data Paths
Choice of 3-State or Open-Collector
Outputs to A Bus
Package Options Include Plastic
Small-Outline (DW) Packages, Ceramic
Chip Carriers (FK), and Standard Plastic
(NT) and Ceramic (JT) 300-mil DIPs
DEVICE
A OUTPUT
B OUTPUT
LOGIC
SN74ALS651A,
’AS651
3 State
3 State
Inverting
SN54ALS652,
SN74ALS652A,
’AS652
3 State
3 State
True
’ALS653
Open Collector
3 State
Inverting
SN74ALS654
Open Collector
3 State
True
SN54ALS’, SN54AS’ . . . JT PACKAGE
SN74ALS’, SN74AS’ . . . DW OR NT PACKAGE
(TOP VIEW)
CLKAB
SAB
OEAB
A1
A2
A3
A4
A5
A6
A7
A8
GND
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9
16
10
15
11
14
12
13
VCC
CLKBA
SBA
OEBA
B1
B2
B3
B4
B5
B6
B7
B8
SN54ALS’, SN54AS’ . . . FK PACKAGE
(TOP VIEW)
OEAB
SAB
CLKAB
NC
VCC
CLKBA
SAB
D
D
description
A1
5
4
3 2 1 28 27 26
25
OEBA
A7
A8
GND
NC
B8
B7
B6
These devices consist of bus-transceiver circuits,
24 B1
A2 6
D-type flip-flops, and control circuitry arranged for
7
23 B2
A3
multiplexed transmission of data directly from the
8
22 NC
NC
data bus or from the internal storage registers.
21 B3
A4 9
Output-enable (OEAB and OEBA) inputs are
20 B4
A5 10
provided to control the transceiver functions.
19 B5
A6 11
Select-control (SAB and SBA) inputs are provided
12 13 14 15 16 17 18
to select real-time or stored data transfer. The
circuitry used for select control eliminates the
typical decoding glitch that occurs in a multiplexer
during the transition between stored and real-time
NC – No internal connection
data. A low input level selects real-time data, and
a high input level selects stored data. Figure 1
illustrates the four fundamental bus-management functions that can be performed with the octal bus
transceivers and registers.
Data on the A or B data bus, or both, can be stored in the internal D-type flip-flops by low-to-high transitions at
the appropriate clock (CLKAB or CLKBA) terminals, regardless of the select- or output-control terminals. When
SAB and SBA are in the real-time transfer mode, it is possible to store data without using the internal D-type
flip-flops by simultaneously enabling OEAB and OEBA. In this configuration, each output reinforces its input.
When all other data sources to the two sets of bus lines are at high impedance, each set of bus lines remains
at its last state.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
description (continued)
The -1 versions of the SN74ALS651A and SN74ALS652A are identical to the standard versions except that the
recommended maximum IOL for the -1 versions is increased to 48 mA. There are no -1 versions of the
SN54ALS652, SN54ALS653, SN74ALS653, and SN74ALS654.
The SN54ALS’ and SN54AS’ families are characterized for operation over the full military temperature range
of – 55°C to 125°C. The SN74ALS’ and SN74AS’ families are characterized for operation from 0°C to 70°C.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
3
21
OEAB OEBA
L
L
1
23
2
CLKAB CLKBA SAB
X
X
X
BUS B
BUS A
BUS A
BUS B
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
22
SBA
L
3
21
OEAB OEBA
H
H
21
OEBA
H
X
H
1
23
2
CLKAB CLKBA SAB
↑
X
↑
X
↑
↑
X
X
X
2
SAB
L
22
SBA
X
BUS B
BUS A
BUS A
3
OEAB
X
L
L
23
CLKBA
X
REAL-TIME TRANSFER
BUS A TO BUS B
BUS B
REAL-TIME TRANSFER
BUS B TO BUS A
1
CLKAB
X
22
3
21
1
23
2
22
SBA
OEAB
H
OEBA
L
CLKAB
CLKBA
SAB
SBA
H or L
H or L
H
H
X
X
X
STORAGE FROM
A, B, OR A AND B
TRANSFER STORED DATA
TO A AND/OR B
Pin numbers are for the DW, JT, and NT packages.
Figure 1. Bus-Management Functions
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
FUNCTION TABLES
SN54ALS653, SN54AS651,
SN74ALS651A, SN74ALS653, SN74AS651
DATA I/O†
INPUTS
OPERATION OR FUNCTION
OEAB
OEBA
CLKAB
CLKBA
SAB
SBA
A1– A8
B1– B8
L
H
H or L
H or L
X
X
Input
Input
Isolation
L
H
↑
↑
X
X
Input
Input
Store A and B data
X
H
↑
H or L
X
Input
Unspecified‡
Store A, hold B
H
H
↑
↑
X
X‡
X
Input
Output
Store A in both registers
L
X
H or L
↑
X
Unspecified‡
Input
Hold A, store B
L
L
↑
↑
X
X
X‡
Output
Input
Store B in both registers
L
L
X
X
X
L
Output
Input
Real-time B data to A bus
L
L
X
H or L
X
H
Output
Input
Stored B data to A bus
H
H
X
X
L
X
Input
Output
Real-time A data to B bus
H
H
H or L
X
H
X
Input
Output
Stored A data to B bus
H
L
H or L
H or L
H
H
Output
Output
Stored A data to B bus and
stored B data to A bus
† The data output functions may be enabled or disabled by a variety of level combinations at OEAB or OEBA. Data input functions are always
enabled; i.e., data at the bus terminals is stored on every low-to-high transition on the clock inputs.
‡ Select control = L; clocks can occur simultaneously.
Select control = H; clocks must be staggered to load both registers.
SN54ALS652, SN54AS652,
SN74ALS652A, SN74ALS654, SN74AS652
DATA I/O†
INPUTS
OPERATION OR FUNCTION
OEAB
OEBA
CLKAB
CLKBA
SAB
SBA
A1– A8
B1– B8
L
H
H or L
H or L
X
X
Input
Input
Isolation
Input
Unspecified‡
Store A and B data
Store A in both registers
L
H
↑
↑
X
X
Input
X
H
↑
H or L
X
Input
H
H
↑
↑
X
X‡
X
X
H or L
↑
X
Input
Hold A, store B
L
L
↑
↑
X
X
X‡
Input
Unspecified‡
Output
L
Output
Input
Store B in both registers
L
L
X
X
X
L
Output
Input
Real-time B data to A bus
L
L
X
H or L
X
H
Output
Input
Stored B data to A bus
H
H
X
X
L
X
Input
Output
Real-time A data to B bus
H
H
H or L
X
H
X
Input
Output
Stored A data to B bus
Output
Stored A data to B bus and
stored B data to A bus
H
L
H or L
H or L
H
H
Output
Store A, hold B
† The data output functions may be enabled or disabled by a variety of level combinations at OEAB or OEBA. Data input functions are always
enabled; i.e., data at the bus terminals is stored on every low-to-high transition on the clock inputs.
‡ Select control = L; clocks can occur simultaneously.
Select control = H; clocks must be staggered to load both registers.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
logic symbols†
SN54AS651,
SN74ALS651A, SN74AS651
OEBA
OEAB
CLKBA
SBA
CLKAB
SAB
A1
21
3
23
22
1
EN1 [BA]
OEBA
EN2 [AB]
OEAB
2
C6
G7
4
≥1
A4
A5
A6
A7
A8
SBA
CLKAB
SAB
5
1
20
4D
B1
A1
5 1
7
1
A3
CLKBA
C4
G5
6D
A2
SN54ALS652, SN54AS652,
SN74ALS652A, SN74AS652
≥1
21
3
23
22
1
OEAB
C6
G7
4
≥1
7
6
18
7
17
8
16
9
15
10
14
11
13
A2
B3
A3
B4
A4
B5
A5
B6
A6
B7
A7
B8
A8
CLKBA
SBA
CLKAB
SAB
A1
23
22
1
OEBA
EN2 [AB]
OEAB
4
≥1
A4
A5
A6
A7
A8
SAB
5
4D
20
B1
A1
5 1
7
1
A3
SBA
CLKAB
1
6D
A2
CLKBA
C4
G5
C6
G7
≥1
20
B1
≥1
2
7
5
19
6
18
7
17
8
16
9
15
10
14
11
13
B2
B3
B4
B5
B6
B7
B8
SN74ALS654
EN1 [BA]
2
4D
5 1
7
1
B2
5
1
2
19
3
C4
G5
6D
5
21
EN2 [AB]
2
SN54ALS653, SN74ALS653
OEBA
EN1 [BA]
21
3
23
22
1
EN1 [BA]
EN2 [AB]
C4
G5
2
C6
G7
4
≥1
1
7
1
19
6
18
7
17
8
16
9
15
10
14
11
13
B2
A2
B3
A3
B4
A4
B5
A5
B6
A6
B7
B8
A7
A8
4D
20
B1
5 1
6D
2
7
5
5
≥1
2
7
5
19
6
18
7
17
8
16
9
15
10
14
11
13
B2
B3
B4
B5
B6
B7
B8
† These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the DW, JT, and NT packages.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
logic diagrams (positive logic)
OEBA
OEAB
CLKBA
SBA
CLKAB
SAB
21
SN54ALS653, SN54AS651,
SN74ALS651A, SN74ALS653, SN74AS651
3
23
22
1
2
One of Eight Channels
1D
C1
A1
4
20
1D
B1
C1
To Seven Other Channels
OEBA
OEAB
CLKBA
SBA
CLKAB
SAB
21
3
SN54ALS652, SN54AS652,
SN74ALS652A, SN74ALS654, SN74AS652
23
22
1
2
One of Eight Channels
1D
C1
A1
4
20
1D
C1
To Seven Other Channels
Pin numbers shown are for the DW, JT, and NT packages.
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
B1
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI: Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
I / O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, TA: SN54ALS652 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS651A, SN74ALS652A . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74ALS651A
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
IOL
Low level output current
Low-level
fclock
Clock frequency
High-level input voltage
MIN
NOM
MAX
4.5
5
5.5
2
UNIT
V
V
High-level output current
0.8
V
– 15
mA
24
48‡
0
CLKBA or CLKAB high
12.5
CLKBA or CLKAB low
12.5
40
mA
MHz
tw
Pulse duration
tsu
th
Setup time before CLKAB↑ or CLKBA↑
A or B
10
ns
Hold time after CLKAB↑ or CLKBA↑
A or B
0
ns
TA
Operating free-air temperature
‡ Applies only to the SN74ALS651A-1 and only if VCC is maintained between 4.75 V and 5.25 V
ns
0
70
°C
recommended operating conditions
SN54ALS652
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
IOL
Low level output current
Low-level
fclock
Clock frequency
tw
Pulse duration
tsu
th
Setup time before CLKAB↑ or CLKBA↑
Hold time after CLKAB↑ or CLKBA↑
High-level input voltage
SN74ALS652A
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
2
High-level output current
2
0.7
0.8
V
– 12
– 15
mA
12
24
35
0
CLKBA or CLKAB high
14.5
12.5
CLKBA or CLKAB low
14.5
12.5
A or B
15
10
A or B
5
0
TA
Operating free-air temperature
– 55
‡ Applies only to the SN74ALS652A-1 and only if VCC is maintained between 4.75 V and 5.25 V
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
V
V
48‡
0
UNIT
125
0
40
mA
MHz
ns
ns
ns
70
°C
7
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
SN74ALS651A
TYP†
MAX
MIN
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 0.4 mA
5V
VCC = 4
4.5
IOH = – 3 mA
IOH = – 15 mA
VCC = 4
4.5
5V
IOL = 12 mA
IOL = 24 mA
0.25
0.4
0.35
0.5
VCC = 4.75 V,
VCC = 5.5 V,
IOL = 48 mA (-1 versions)
VI = 7 V
0.35
0.5
Control inputs
A or B ports
VCC = 5.5 V,
VI = 5.5 V
VCC = 5.5
55V
V,
VI = 2
2.7
7V
VCC = 5.5
55V
V,
VI = 0
0.4
4V
VCC = 5.5 V,
VO = 2.25 V
VOH
VOL
II
TEST CONDITIONS
– 1.2
VCC – 2
2.4
A or B ports‡
2
0.1
0.1
20
20
Control inputs
IIL
IO§
ICC
A or B ports‡
V
V
3.2
Control inputs
IIH
UNIT
V
mA
µA
A
– 0.2
VCC = 5.5 V
– 0.2
– 30
– 112
Outputs high
42
68
Outputs low
52
82
Outputs disabled
52
82
mA
mA
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ For I/O ports, the parameters IIH and IIL include the off-state output current.
§ The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
8
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 0.4 mA
VCC = 4.5 V
IOH = – 3 mA
IOH = – 12 mA
VCC = 4
4.5
5V
VOL
MIN
A or B ports
VCC = 5.5 V,
VI = 7 V
VI = 5.5 V
3.2
VCC = 5.5
55V
V,
VI = 2
2.7
7V
55V
VCC = 5.5
V,
4V
VI = 0
0.4
IO§
VCC = 5.5 V,
VO = 2.25 V
ICC
VCC = 5.5 V
A or B ports‡
UNIT
V
V
2
0.25
Control inputs
IIL
3.2
2
Control inputs
A or B ports‡
– 1.2
VCC – 2
2.4
0.4
IOL = 24 mA
IOL = 48 mA (-1 versions)
Control inputs
IIH
SN74ALS652A
TYP†
MAX
MIN
– 1.2
VCC – 2
2.4
IOH = – 15 mA
IOL = 12 mA
VCC = 4.75 V,
VCC = 5.5 V,
II
SN54ALS652
TYP†
MAX
TEST CONDITIONS
– 20
0.25
0.4
0.35
0.5
0.35
0.5
0.1
0.1
0.1
0.1
20
20
20
20
– 0.2
– 0.2
– 0.2
– 0.2
– 112
– 30
– 112
Outputs high
47
76
47
76
Outputs low
55
88
55
88
Outputs disabled
55
88
55
88
V
mA
µA
A
mA
mA
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ For I/O ports, the parameters IIH and IIL include the off-state output current.
§ The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
R1 = 500 Ω,
R2 = 500 Ω,
TA = MIN to MAX†
UNIT
SN74ALS651A
MIN
fmax
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
tPZH
tPZL
tPHZ
CLKBA or CLKAB
A or B
A or B
B or A
SBA or SAB‡
(with A or B high)
A or B
SBA or SAB‡
(with A or B low)
A or B
OEBA
A
OEBA
A
OEAB
B
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
MHz
8
32
5
17
2
18
2
10
8
38
6
21
8
25
7
21
3
20
5
18
2
9
3
12
3
22
6
21
2
OEAB
B
tPLZ
2
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡ These parameters are measured with the internal output state of the storage register opposite that of the bus input.
10
MAX
40
12
14
ns
ns
ns
ns
ns
ns
ns
ns
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
R1 = 500 Ω,
R2 = 500 Ω,
TA = MIN to MAX†
SN54ALS652
MIN
fmax
tPLH
MAX
35
UNIT
SN74ALS652A
MIN
MAX
40
MHz
10
35
8
30
5
20
5
17
5
20
4
18
3
15
3
12
15
40
8
35
6
23
6
20
8
30
8
25
5
24
5
20
3
20
3
17
5
22
5
18
1
12
1
10
2
20
2
16
8
25
3
22
6
21
5
18
1
12
1
OEAB
B
tPLZ
2
21
2
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡ These parameters are measured with the internal output state of the storage register opposite that of the bus input.
10
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
tPZH
tPZL
tPHZ
CLKBA or CLKAB
A or B
A or B
B or A
SBA or SAB‡
(with A or B high)
A or B
SBA or SAB‡
(with A or B low)
A or B
OEBA
A
OEBA
A
OEAB
B
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
16
ns
ns
ns
ns
ns
ns
ns
ns
11
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI: All inputs and A I / O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
B I / O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, TA: SN54ALS653 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS653, SN74ALS654 . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS653
VCC
VIH
Supply voltage
VIL
VOH
Low-level input voltage
High-level output voltage
IOH
IOL
High-level output current
fclock
Clock frequency
tw
Pulse duration
tsu
th
TA
Operating free-air temperature
SN74ALS653
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
High-level input voltage
2
2
UNIT
V
V
0.7
0.8
V
A ports
5.5
5.5
V
B ports
– 12
– 15
mA
12
24
mA
35
MHz
Low-level output current
0
25
0
CLKBA or CLKAB high
20
14.5
CLKBA or CLKAB low
20
14.5
Setup time before CLKAB↑ or CLKBA↑
A or B
15
10
Hold time after CLKAB↑ or CLKBA↑
A or B
5
0
– 55
125
ns
ns
ns
0
70
°C
recommended operating conditions
SN74ALS654
VCC
VIH
Supply voltage
VIL
VOH
Low-level input voltage
High-level output voltage
IOH
IOL
High-level output current
fclock
Clock frequency
High-level input voltage
MIN
NOM
MAX
4.5
5
5.5
2
V
V
A ports
5.5
V
B ports
– 15
mA
24
mA
35
MHz
Low-level output current
0
CLKBA or CLKAB high
14.5
CLKBA or CLKAB low
14.5
Pulse duration
tsu
th
Setup time before CLKAB↑ or CLKBA↑
A or B
10
Hold time after CLKAB↑ or CLKBA↑
A or B
0
TA
Operating free-air temperature
0
POST OFFICE BOX 655303
V
0.8
tw
12
UNIT
• DALLAS, TEXAS 75265
ns
ns
ns
70
°C
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
B ports
VOL
II
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 0.4 mA
VCC = 4.5 V
IOH = – 3 mA
IOH = – 12 mA
VCC = 4
4.5
5V
Control inputs
A or B ports
VCC = 5.5 V,
VCC = 5.5 V,
SN54ALS653
TYP†
MAX
MIN
–1.2
VCC – 2
2.4
IOH
IO§
ICC
0.25
0.4
0.35
0.5
0.1
0.1
0.1
0.1
20
20
20
20
– 0.2
– 0.2
– 0.2
– 0.2
VI = 0
0.4
4V
A ports
VCC = 4.5 V,
VOH = 5.5 V
B ports
VCC = 5.5 V,
VO = 2.25 V
VCC = 5.5 V
0.4
VI = 5.5 V
VCC = 5.5
55V
V,
A or B ports‡
V
V
IOL = 24 mA
VI = 7 V
VI = 2
2.7
7V
UNIT
2
0.25
Control inputs
IIL
3.2
2
IOH = – 15 mA
IOL = 12 mA
VCC = 5.5
55V
V,
A or B ports‡
–1.2
VCC – 2
2.4
3.2
Control inputs
IIH
SN74ALS653
TYP†
MAX
MIN
0.1
– 20
– 112
– 30
V
mA
µA
A
mA
0.1
mA
– 112
mA
Outputs high
47
76
47
76
Outputs low
55
88
55
88
Outputs disabled
55
88
55
88
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ For I/O ports, the parameters IIH and IIL include the off-state output current.
§ The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
13
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
B ports
VOL
II
Control inputs
A or B ports
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 0.4 mA
5V
VCC = 4
4.5
IOH = – 3 mA
IOH = – 15 mA
VCC = 4
4.5
5V
IOL = 12 mA
IOL = 24 mA
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 5.5 V
IIH
Control inputs
A or B ports‡
VCC = 5
5.5
5V
V,
VI = 2
2.7
7V
IIL
Control inputs
A or B ports‡
VCC = 5
5.5
5V
V,
VI = 0
0.4
4V
VCC = 4.5 V,
VCC = 5.5 V,
VOH = 5.5 V
VO = 2.25 V
IOH
IO§
ICC
A ports
B ports
VCC = 5.5 V
SN74ALS654
TYP†
MAX
MIN
– 1.2
VCC – 2
2.4
UNIT
V
V
3.2
2
0.25
0.4
0.35
0.5
0.1
0.1
20
20
– 0.2
– 0.2
– 30
V
mA
µA
mA
0.1
mA
– 112
mA
Outputs high
47
76
Outputs low
55
88
Outputs disabled
55
88
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ For I/O ports, the parameters IIH and IIL include the off-state output current.
§ The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
14
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 680 Ω (A outputs),
R1 = R2 = 500 Ω (B outputs),
TA = MIN to MAX†
SN54ALS653
MIN
fmax
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
SN74ALS653
MAX
25
CLKBA
A
CLKAB
B
A
B
B
A
SBA‡
(with B high)
A
SBA‡
(with B low)
A
SAB‡
(with A high)
B
SAB‡
(with A low)
B
OEBA
A
OEAB
B
• DALLAS, TEXAS 75265
MIN
MAX
35
MHz
16
71
16
64
6
24
6
22
10
35
10
30
5
20
5
17
5
20
5
18
1.5
18
2
15
8
63
12
56
2
18
2
15
12
68
19
62
5
27
5
25
12
68
19
62
5
27
5
25
8
30
15
35
6
25
6
22
12
40
8
25
6
25
6
22
6
35
6
30
6
27
6
24
7
25
8
22
6
25
6
22
1
14
2
16
1
16
OEAB
B
tPLZ
2
21
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡ These parameters are measured with the internal output state of the storage register opposite that of the bus input.
POST OFFICE BOX 655303
UNIT
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
15
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 680 Ω (A outputs),
R1 = R2 = 500 Ω (B outputs),
TA = MIN to MAX†
UNIT
SN74ALS654
MIN
fmax
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
MAX
35
CLKBA
A
CLKAB
B
A
B
B
A
SBA‡
(with B low)
A
SBA‡
(with B high)
A
SAB‡
(with A low)
B
SAB‡
(with A high)
B
OEBA
A
OEAB
B
16
64
6
22
10
30
5
17
5
18
2
15
12
56
2
21
19
62
5
25
19
62
5
25
15
35
6
22
8
25
6
22
6
30
6
24
6
22
6
22
1
OEAB
B
tPLZ
2
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡ These parameters are measured with the internal output state of the storage register opposite that of the bus input.
16
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
MHz
14
16
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI: Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
I/ O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, TA: SN54AS651, SN54AS652 . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74AS651, SN74AS652 . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS651
SN54AS652
SN74AS651
SN74AS652
UNIT
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.8
0.8
V
High-level output current
–12
–15
mA
IOL
fclock*
Low-level output current
32
48
mA
90
MHz
High-level input voltage
2
Clock frequency
0
2
75
0
CLKBA or CLKAB high
6
5
CLKBA or CLKAB low
7
6
V
V
tw*
Pulse duration
tsu*
th*
Setup time before CLKAB↑ or CLKBA↑
A or B
7
6
ns
Hold time after CLKAB↑ or CLKBA
A or B
0
0
ns
TA
Operating free-air temperature
– 55
125
0
* On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
ns
70
°C
17
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
SN54AS651
SN54AS652
TEST CONDITIONS
MIN
VIK
VOH
VOL
II
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 2 mA
VCC = 4.5 V
IOH = – 3 mA
IOH = – 12 mA
5V
VCC = 4
4.5
Control inputs
A or B ports
VCC = 5.5 V,
VCC = 5.5 V,
TYP†
A or B ports‡
VCC – 2
2.4
A or B ports‡
IO§
′AS651
TYP†
UNIT
MAX
– 1.2
3.2
IOH = – 15 mA
IOL = 32 mA
2
0.25
0.5
IOL = 48 mA
VI = 7 V
0.35
0.5
0.1
0.1
VI = 5.5 V
0.1
0.1
20
20
70
70
– 0.5
– 0.5
– 0.75
– 0.75
VI = 2
2.7
7V
VCC = 5.5
55V
V,
VI = 0
0.4
4V
VCC = 5.5 V,
VO = 2.25 V
Outputs high
110
185
110
185
VCC = 5.5 V
Outputs low
120
195
120
195
Outputs disabled
130
195
130
195
Outputs high
120
195
120
195
Outputs low
130
211
130
211
VCC = 5.5 V
V
V
2
VCC = 5.5
55V
V,
ICC
′AS652
MIN
VCC – 2
2.4
3.2
Control input
IIL
MAX
– 1.2
Control inputs
IIH
SN74AS651
SN74AS652
– 30
– 112
– 30
– 112
V
mA
µA
A
mA
mA
mA
Outputs disabled
130
211
130
211
† All typical values are at VCC = 5 V, TA = 25 °C.
‡ For I/O ports, the parameters IIH and IIL include the off-state output current.
§ The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS.
18
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
R1 = 500 Ω,
R2 = 500 Ω,
TA = MIN to MAX†
SN54AS651
MIN
fmax*
tPLH
MAX
75
UNIT
SN74AS651
MIN
MAX
90
MHz
2
11
2
8.5
2
10
2
9
2
12
2
8
1
8
1
7
2
15
2
11
2
11
2
9
2
11
2
10
3
18
3
16
2
10
2
9
2
10
2
9
3
12
3
11
3
20
3
16
2
11
2
OEAB
B
tPLZ
2
12
2
* On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested.
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡ These parameters are measured with the internal output state of the storage register opposite that of the bus input.
10
tPHL
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
tPZH
tPZL
tPHZ
CLKBA or CLKAB
A or B
A or B
B or A
SBA or SAB‡
A or B
OEBA
A
OEBA
A
OEAB
B
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
ns
ns
ns
ns
ns
ns
ns
19
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
switching characteristics (see Figure 2)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V TO 5.5 V,
CL = 50 PF,
R1 = 500 Ω,
R2 = 500 Ω,
TA = MIN TO MAX†
SN54AS652
MIN
fmax*
tPLH
MAX
75
UNIT
SN74AS652
TYP
MAX
90
MHz
2
11
2
8.5
2
10
2
9
2
12
2
9
1
8
1
7
2
15
2
11
2
11
2
9
2
11
2
10
3
18
3
16
2
10
2
9
2
10
2
9
3
12
3
11
3
20
3
16
2
11
2
OEAB
B
tPLZ
2
12
2
* On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested.
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
‡ These parameters are measured with the internal output state of the storage register opposite that of the bus input.
10
tPHL
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
tPZH
tPZL
tPHZ
20
CLKBA or CLKAB
A or B
A or B
B or A
SBA or SAB‡
A or B
OEBA
A
OEBA
A
OEAB
B
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
11
ns
ns
ns
ns
ns
ns
ns
SN54ALS652, SN54ALS653, SN54AS651, SN54AS652
SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652
OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS
SDAS066F – DECEMBER 1983 – REVISED OCTOBER 1996
PARAMETER MEASUREMENT INFORMATION
7V
VCC
SWITCH POSITION TABLE
Open
S1
TEST
S1
tPLH
tPHL
Open
Open
tPZH
tPZL
Open
Closed
tPHZ
Open
tPLZ
Closed
R1 = 500 Ω
From Output
Under Test
CL = 50 pF
(see Note A)
Test Point
R2 = 500 Ω
RL
From Output
Under Test
Test Point
CL = 50 pF
(see Note A)
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
3.5 V
Timing
Input
1.3 V
High-Level
Pulse
0.3 V
tw
0.3 V
th
tsu
Data
Input
1.3 V
1.3 V
3.5 V
1.3 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
1.3 V
0.3 V
0.3 V
VOLTAGE WAVEFORMS
PULSE DURATION
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
3.5 V
Output
Control
1.3 V
1.3 V
0.3 V
3.5 V
Input
1.3 V
tPZL
1.3 V
tPLZ
0.3 V
In-Phase
Output
VOH
1.3 V
VOL
1.3 V
Waveform 1
S1 Closed
(see Note B)
VOH
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
1.3 V
tPHZ
tPLH
tPHL
Out-of-Phase
Output
3.5 V
tPHL
tPLH
tPZH
Waveform 2
S1 Open
(see Note B)
VOL
0.3 V
VOH
1.3 V
0.3 V
0V
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, Zo = 50 Ω, tr ≤ 2 ns, tf ≤ 2 ns.
D. The outputs are measured one at a time with one transition per measurement.
Figure 2. Load Circuits and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
21
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated