12 1-800-735-6200 Sept. 99 Rev 2 1 of 2 VI-J00 MiniMod DC-DC Converters 25 to 100 Watts Converter Selection Chart VI-J Features ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Output Voltage Input Voltage Up to 50W/Cubic Inch UL, CSA, TÜV, VDE, BABT CE Marked 80-90% Efficiency Size: 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7) Remote Sense and Current Limit Logic Disable Wide Range Output Adjust ZCS Power Architecture Low Noise FM Control Nominal 0 = 1 = W= 2 = 3 = N = 4 = T = 5 = 6 = 7 = The VI-J00 MiniMod family establishes a new standard in component-level DC-DC converters. This “junior” size complement to the higher power VI-200 family offers up to 100W of isolated and regulated power in a board mounted package. At one-half the size and twice the power density of previous 100W modules, and with a maximum operating temperature rating of 100˚C, the MiniMod opens new horizons for board-mounted (distributed) power architectures. Utilizing Vicor’s “zero-currentswitching” forward converter technology, proven by an installed base of over 8 million units, the MiniMod family combines state of the art power density with the efficiency, low noise and reliability required by next generation power systems. Range 12V 10 - 20V(4) n/a 24V 21 - 32V(2) 18V 24V 18 - 36V(2) n/a 36V 21 - 56V(1) 18V 48V 42 - 60V(2) 36V 48V 36 - 76V(2) n/a 72V 55 - 100V(4) 45V 110V 66 - 160V(2) n/a 150V 100 - 200V(2) 85V 300V 200 - 400V(3) 170V 150/300V 100 - 375V(1) 90V Product Grade/ Operating Temp. Product Highlights E = C = I = M= -10°C -25°C -40°C -55°C to to to to +100°C +100°C +100°C +100°C Z Y 0 M 1 2 3 L 4 22V 36V n/a 60V 72V n/a 110V n/a 215V 425V n/a Product Grade/ Storage Temp. E C I M = = = = -20°C -40°C -55°C -65°C = = = = = = = = = 2V 3.3V 5V 10V 12V 15V 24V 28V 48V 1 to 95V, consult factory. Output Power/Current VOUT ≥ 5V Z = 25W Y = 50W X = 75W W = 100W to +105°C to +105°C to +105°C to +105°C Max. Output For 5V Outputs > 5V Outputs < 5V Outputs (1) 50W 50W 10A (2) 75W 100W 20A Z Y X W VOUT < 5V = 5A = 10A = 15A = 20A Max. Output For 5V Outputs > 5V Outputs < 5V Outputs (3) 100W 100W 20A (4) 50W 75W 15A *Brownout 75% of rated load; transient voltage for 1 second. Mechanical Drawing 2.28 (57,9) .49 (12,4) .30 (7,6) ±.015 (0,38) .080 Dia (2) places Solder plate over copper alloy 1.30 (33,0) .65 (16,5) Pin # 1 4 9 3 8 VI-J00 2.10 (53,4) 2 Packaging Options SlimMods™, high power density, flangeless packages and FinMods™, featuring integral finned heatsinks. Brownout / Transient* 1 .15 (3,8) 5 FULL R .15 (3,8) SlimMod: Option suffix: - S Example: VI - JXX - XX - S FinMod: Option suffix: - F1 and - F2 Examples: VI - JXX - XX -F1, 0.75" height VI - JXX - XX -F2, 1.00" height 7 6 1.40 1.00 (35,6) .70 (25,4) .40 (17,8) (10,2) .35 (8,9) ± .015 (0,38) Function +In 2 Gate In 3 Gate Out 4 -In 5 +Out 6 +Sense 7 Trim 8 –Sense 9 –Out .040 (1,0) Dia (7) places Solder plate over copper alloy Product ID this surface 2.40 (61,0) 1.90 (48,3) .30 (7,6) Min. 1.75 (44,4) Max. .22 (5,6) Min. (0,76) .50 (12,7) +.030 -.000 (0) .01 .12 (3,0) Aluminum Base For the latest Vicor Product Information: www.vicr.com 12 1-800-735-6200 Sept. 99 2 of 2 Converter Specifications (typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified) VI-J00 E-Grade PARAMETER MIN. ■ Input Characteristics Inrush charge Input reflected ripple current – pp Input ripple rejection TYP. ( ) MAX. UNITS TEST CONDITIONS 60x10 -6 10% 100x10-6 Coulombs IIN Nominal line Nominal line, full load dB 120 Hz, nominal line dB 2400 Hz, nominal line 30+20Log Vin Vout 20+20Log Vin Vout 1.35 2 1.35 2 Watts 1.0% 2.0% 0.5% 0.5% 0.05% 1.0% 0.2% VNOM VNOM LL to HL, 10% to Full Load 1.0% 0.2% 0.5% VNOM LL to HL, No Load to 10% 0.02 0.02 0.01 0.02 0.02 %/°C %/1K hours 200 5% 3% 100 2% 0.75% 150 3% 1.5% 110% mV Load/line regulation ■ Dielectric Withstand Characteristics Input to output Output to baseplate Input to baseplate TYP. ( ) ( ) 25+20Log Vin Vout ■ Output Characteristics Setpoint accuracy Load/line regulation ■ Control Pin Characteristics Gate out impedance Gate in impedance Gate in high threshold Gate in low threshold Gate in low current MIN. 60x10 -6 10% No load power dissipation Output temperature drift Long term drift Output ripple - pp: 2V, 3.3V 5V 10-48V Trim range1 Total remote sense compensation Current limit Short circuit current VI-J00 C-, I-, M-Grade MAX. 50% 0.5 105% 105% 110% 135% 140% 50% 0.5 105% 105% 50 10 3 6 125% 130% 50 10 3 6 0.65 0.65 6 3,000 500 1,500 6 3,000 500 1,500 20 MHz bandwidth 20 MHz bandwidth 20 MHz bandwidth VNOM Volts INOM INOM 0.25V max. neg. leg Automatic restart Ohms Ohms Volts Volts mA Use open collector VRMS VRMS VRMS ■ Thermal Characteristics Efficiency Baseplate to sink 78-88% 0.4 80-90% 0.4 °C/Watt ■ Mechanical Specifications Weight 3.0 (85) 3.0 (85) Ounces (Grams) 110V, Over rated temperature Baseplate earthed With Vicor P/N 04308 12V and 15V outputs, standard trim range ±10%. Consult factory for wider trim range. For product compliance with agency standards please refer to pages 67 - 69. For the latest Vicor Product Information: www.vicr.com