TV18..F TV18..F Fast Recovery Diode Replaces March 1998 version, DS4211-2.2 DS4211-3.0 January 2000 KEY PARAMETERS VRRM 2500V IF(AV) 200A IFSM 3500A Qr 240µC trr 2.0µs APPLICATIONS ■ Induction Heating ■ A.C. Motor Drives ■ Snubber Diode ■ Welding ■ High Frequency Rectification ■ UPS FEATURES ■ Thermal Fatigue Free Pressure Contact ■ High Surge Capability ■ Low Recovery Charge VOLTAGE RATINGS Type Number Repetitive Peak Reverse Voltage VRRM V TV18 25F M or K TV18 24F M or K TV18 22F M or K TV18 20F M or K 2500 2400 2200 2000 Conditions VRSM = VRRM + 100V For 3/4" 16 UNF thread, add suffix K, e.g. TV18 25FK. For M16 thread, add suffix M, e.g. TV18 25FM. For stud anode add 'R' to type number, e.g. TV18 25FMR. Outline type codes: DO9. See Package Details for further information. CURRENT RATINGS Symbol Parameter Conditions Max. Units IF(AV) Mean forward current Half wave resistive load, Tcase = 65oC 200 A IF(RMS) RMS value Tcase = 65oC 320 A 1/8 TV18..F SURGE RATINGS Symbol IFSM I2t IFSM I2t Conditions Parameter Surge (non-repetitive) forward current Max. Units 3.5 kA 61 x 103 A2s 2.8 kA 39.2x 103 A2s 10ms half sine; with 0% VRRM, Tj = 150oC I2t for fusing Surge (non-repetitive) forward current 10ms half sine; with 50% VRRM, Tj = 150oC I2t for fusing THERMAL AND MECHANICAL DATA Conditions Parameter Symbol dc Min. Max. Units - 0.16 o o C/W Rth(j-c) Thermal resistance - junction to case Rth(c-h) Thermal resistance - case to heatsink Mounting torque 35.0Nm with mounting compound - 0.06 Tvj Virtual junction temperature On-state (conducting) - 150 o Tstg Storage temperature range -55 175 o Mounting torque 30.0 35.0 Nm Typ. Max. Units - C/W C C CHARACTERISTICS Symbol Conditions VFM Forward voltage At 1000A peak, Tcase = 25oC - 3.1 V IRRM Peak reverse current At VRRM, Tcase = 150oC - 50 mA - 3.2 µs trr Reverse recovery time Recovered charge (50% chord) IF = 1000A, diRR/dt = 100A/µs - 240 µC IRM Reverse recovery current Tcase = 150oC, VR = 100V - 160 A K Soft factor 1.3 - - QRA1 VTO Threshold voltage At Tvj = 150oC - 1.64 V rT Slope resistance At Tvj = 150oC - 1.54 mΩ Forward recovery voltage di/dt = 1000A/µs, Tj = 125oC - 120 V VFRM 2/8 Parameter TV18..F DEFINITION OF K FACTOR AND QRA1 QRA1 = 0.5x IRR(t1 + t2) dIR/dt t1 t2 k = t1/t2 τ 0.5x IRR IRR CURVES 2000 Measured under pulse conditions Instantaneous forward current IF - (A) 1750 1500 1250 Tj = 150˚C 1000 Tj = 25˚C 750 500 1.0 2.0 3.0 4.0 5.0 Instantaneous forward voltage VF - (V) Fig.1 Maximum (limit) forward characteristics 3/8 TV18..F 500 Measured under pulse conditions Instantaneous forward current IF - (A) 400 Tj = 150˚C 300 Tj = 25˚C 200 100 0 1.0 1.5 2.0 2.5 3.0 Instantaneous forward voltage VF - (V) Fig.2 Maximum (limit) forward characteristics 250 Current waveform VFR Voltage waveform Transient forward votage VFP - (V) 200 δy di = δy dt δx δx 150 Tj = 100˚C limit 100 Tj = 25˚C limit 50 0 0 500 1000 1500 2000 Rate of rise of forward current dIF/dt - (A/µs) Fig.3 Transient forward voltage vs rate of rise of forward current 4/8 TV18..F 10000 QS = ∫ IF 50µs Conditions: 0 Tj = 150˚C, VR = 100V Reverse recovered charge QS - (µC) QS tp = 1ms dIR/dt 1000 IRR IF = 200A IF = 1000A IF = 750A IF = 500A IF = 100A 100 10 1 10 100 Rate of rise of reverse current dIR/dt - (A/µs) 1000 Fig.4 Recovered charge 10000 Conditions: Tj = 150˚C, IF = 1000A IF = 750A IF = 500A Reverse recovery current IRR - (A) VR = 100V IF = 200A 100 IF = 100A 10 1 1 10 100 Rate of rise of reverse current dIR/dt - (A/µs) 1000 Fig.5 Typical reverse recovery current vs rate of rise of reverse current 5/8 TV18..F Thermal impedance - (˚C/W) 0.100 d.c. 0.010 0.001 0.01 0.1 1 Time - (s) 10 Fig.6 Maximum (limit) transient thermal impedance - junction to case - (˚C/W) 6/8 100 TV18..F PACKAGE DETAILS For further package information, please contact your local Customer Service Centre. All dimensions in mm, unless stated otherwise. DO NOT SCALE. Ø4 Ø12.5 ± 0.5 12 min 20 ± 2 230 ± 10 230 ± 10 Hex. 32AF No type + K - 27 ± 0.5 No type + M - 18 ± 0.5 10 min K Thread 3/4" 16 UNF M Thread M16 3.17 max ASSOCIATED PUBLICATIONS Title Application Note Number Calculating the junction temperature or power semiconductors AN4506 Thyristor and diode measurement with a multi-meter AN4853 Use of V , r on-state characteristic AN5001 TO T 7/8 TV18..F POWER ASSEMBLY CAPABILITY The Power Assembly group was set up to provide a support service for those customers requiring more than the basic semiconductor, and has developed a flexible range of heatsink / clamping systems in line with advances in device types and the voltage and current capability of our semiconductors. We offer an extensive range of air and liquid cooled assemblies covering the full range of circuit designs in general use today. The Assembly group continues to offer high quality engineering support dedicated to designing new units to satisfy the growing needs of our customers. Using the up to date CAD methods our team of design and applications engineers aim to provide the Power Assembly Complete solution (PACs). HEATSINKS Power Assembly has it’s own proprietary range of extruded aluminium heatsinks. They have been designed to optimise the performance or our semiconductors. Data with respect to air natural, forced air and liquid cooling (with flow rates) is available on request. For further information on device clamps, heatsinks and assemblies, please contact your nearest Sales Representative or the factory. http://www.dynexsemi.com e-mail: [email protected] HEADQUARTERS OPERATIONS DYNEX SEMICONDUCTOR LTD Doddington Road, Lincoln. Lincolnshire. LN6 3LF. United Kingdom. Tel: 00-44-(0)1522-500500 Fax: 00-44-(0)1522-500550 DYNEX POWER INC. Unit 7 - 58 Antares Drive, Nepean, Ontario, Canada K2E 7W6. Tel: 613.723.7035 Fax: 613.723.1518 Toll Free: 1.888.33.DYNEX (39639) CUSTOMER SERVICE CENTRES France, Benelux, Italy and Spain Tel: +33 (0)1 69 18 90 00. Fax: +33 (0)1 64 46 54 50 North America Tel: 011-800-5554-5554. Fax: 011-800-5444-5444 UK, Germany, Scandinavia & Rest Of World Tel: +44 (0)1522 500500. Fax: +44 (0)1522 500020 SALES OFFICES France, Benelux, Italy and Spain Tel: +33 (0)1 69 18 90 00. Fax: +33 (0)1 64 46 54 50 Germany Tel: 07351 827723 North America Tel: (613) 723-7035. Fax: (613) 723-1518. Toll Free: 1.888.33.DYNEX (39639) / Tel: (831) 440-1988. Fax: (831) 440-1989 / Tel: (949) 733-3005. Fax: (949) 733-2986. UK, Germany, Scandinavia & Rest Of World Tel: +44 (0)1522 500500. Fax: +44 (0)1522 500020 These offices are supported by Representatives and Distributors in many countries world-wide. © Dynex Semiconductor 2000 Publication No. DS4211-3 Issue No. 3.0 January 2000 TECHNICAL DOCUMENTATION – NOT FOR RESALE. PRINTED IN UNITED KINGDOM Datasheet Annotations: Dynex Semiconductor annotate datasheets in the top right hard corner of the front page, to indicate product status. The annotations are as follows:Target Information: This is the most tentative form of information and represents a very preliminary specification. No actual design work on the product has been started. Preliminary Information: The product is in design and development. The datasheet represents the product as it is understood but details may change. Advance Information: The product design is complete and final characterisation for volume production is well in hand. No Annotation: The product parameters are fixed and the product is available to datasheet specification. This publication is issued to provide information only which (unless agreed by the Company in writing) may not be used, applied or reproduced for any purpose nor form part of any order or contract nor to be regarded as a representation relating to the products or services concerned. No warranty or guarantee express or implied is made regarding the capability, performance or suitability of any product or service. The Company reserves the right to alter without prior notice the specification, design or price of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user's responsibility to fully determine the performance and suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. These products are not suitable for use in any medical products whose failure to perform may result in significant injury or death to the user. All products and materials are sold and services provided subject to the Company's conditions of sale, which are available on request. All brand names and product names used in this publication are trademarks, registered trademarks or trade names of their respective owners. 8/8