FUJITSU SEMICONDUCTOR DATA SHEET DS04-21360-4E ASSP Single Serial Input PLL Frequency Synthesizer On-chip 2.0 GHz Prescaler MB15E05SL ■ DESCRIPTION The Fujitsu MB15E05SL is a serial input Phase Locked Loop (PLL) frequency synthesizer with a 2.0 GHz prescaler. The 2.0 GHz prescaler has a dual modulus division ratio of 64/65 or 128/129 enabling pulse swallowing operation. The supply voltage range is between 2.4 V and 3.6 V. The MB15E05SL uses the latest BiCMOS process, as a result the supply current is typically 3.0 mA at 2.7 V. A refined charge pump supplies well-balanced output currents of 1.5 mA and 6 mA. The charge pump current is selectable by serial data. MB15E05SL is ideally suited for wireless mobile communications, such as GSM (Global System for Mobile Communications) and PCS. ■ FEATURES • High frequency operation: 2.0 GHz max • Low power supply voltage: VCC = 2.4 to 3.6 V • Ultra Low power supply current: ICC = 3.0 mA typ. (VCC = Vp = 2.7 V, Ta = +25°C, in locking state) ICC = 3.5 mA typ. (VCC = Vp = 3.0 V, Ta = +25°C, in locking state) • Direct power saving function: Power supply current in power saving mode Typ. 0.1 µA (VCC = Vp = 3.0 V, Ta = +25°C), Max. 10 µA (VCC = Vp = 3.0 V) • Dual modulus prescaler: 64/65 or 128/129 • Serial input 14-bit programmable reference divider: R = 3 to 16,383 • Serial input programmable divider consisting of: - Binary 7-bit swallow counter: 0 to 127 - Binary 11-bit programmable counter: 3 to 2,047 • Software selectable charge pump current • On-chip phase control for phase comparator • Operating temperature: Ta = –40 to +85°C • Pin compatible with MB15E05, MB15E05L ■ PACKAGES 16-pin plastic SSOP (FPT-16P-M05) 16-pad plastic BCC (LCC-16P-M06) 1 MB15E05SL ■ PIN ASSIGNMENTS 16-pin SSOP OSCIN 1 16 φR OSCOUT 2 15 φP VP 3 14 LD/fout VCC 4 DO 5 GND OSCIN φR OSCOUT 1 VP 2 13 ZC 12 PS DO 6 11 LE GND Xfin 7 10 Data fin 8 9 Clock Top view (FPT-16P-M05) 2 16-pad BCC VCC Xfin 16 15 14 13 3 Top view 12 4 11 5 10 6 7 8 9 φP LD/fout ZC PS LE Data fin Clock (LCC-16P-M06) MB15E05SL ■ PIN DESCRIPTIONS Pin no. SSOP BCC Pin name 1 16 OSCIN I Programmable reference divider input. Connection to a TCXO. 2 1 OSCOUT O Oscillator output. 3 2 VP – Power supply voltage input for the charge pump. 4 3 VCC – Power supply voltage input. 5 4 DO O Charge pump output. Phase of the charge pump can be selected via programming of the FC bit. 6 5 GND – Ground. 7 6 Xfin I Prescaler complementary input, which should be grounded via a capacitor. 8 7 fin I Prescaler input. Connection to an external VCO should be done via AC coupling. 9 8 Clock I Clock input for the 19-bit shift register. Data is shifted into the shift register on the rising edge of the clock. (Open is prohibited.) 10 9 Data I Serial data input using binary code. The last bit of the data is a control bit. (Open is prohibited.) 11 10 LE I Load enable signal input. (Open is prohibited.) When LE is set high, the data in the shift register is transferred to a latch according to the control bit in the serial data. I Power saving mode control. This pin must be set at “L” at Power-ON. (Open is prohibited.) PS = “H”; Normal mode PS = “L”; Power saving mode 12 11 PS I/O Descriptions 13 12 ZC I Forced high-impedance control for the charge pump (with internal pull up resistor.) ZC = “H”; Normal Do output. ZC = “L”; Do becomes high impedance. 14 13 LD/fout O Lock detect signal output (LD)/phase comparator monitoring output (fout). The output signal is selected via programming of the LDS bit. LDS = “H”; outputs fout (fr/fp monitoring output) LDS = “L”; outputs LD (“H” at locking, “L” at unlocking.) 15 14 φP O Phase comparator N-channel open drain output for an external charge pump. Phase can be selected via programming of the FC bit. 16 15 φR O Phase comparator CMOS output for an external charge pump. Phase can be selected via programming of the FC bit. 3 MB15E05SL ■ BLOCK DIAGRAM fr (16) OSCIN 1 Reference oscillator circuit Phase comparator (15) 16 φR (14) 15 φP (1) OSCOUT 2 Binary 14-bit reference counter SW FC LDS CS 14-bit latch 4-bit latch (2) VP 3 Lock detector fp LD/fr/fp selector (13) 14 LD/fout .. VCC C N T (3) 4 19-bit shift register Charge pump DO (4) 5 Current switch ... 7-bit latch Binary 7-bit swallow counter (12) 13 ZC ... 11-bit latch Binary 11-bit programmable counter Intermittent mode control (power save) (11) 12 PS (10) 11 LE (5) GND 6 1-bit control latch (6) Xfin 7 MD Prescaler 64/65 128/129 (7) fin 8 : SSOP ( 4 ) : BCC (9) 10 Data (8) 9 Clock MB15E05SL ■ ABSOLUTE MAXIMUM RATINGS Parameter Power supply voltage Input voltage Output voltage Storage temperature Symbol Condition VCC Rating Unit Min. Max. – –0.5 4.0 V VP – VCC 6.0 V VI – –0.5 VCC +0.5 V VO Except Do GND VCC V VO Do GND VP V Tstg – –55 +125 °C Remark WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings. ■ RECOMMENDED OPERATING CONDITIONS Parameter Symbol Value Unit Min. Typ. Max. VCC 2.4 3.0 3.6 V VP VCC – 5.5 V Input voltage VI GND – VCC V Operating temperature Ta –40 – +85 °C Power supply voltage Remark WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device’s electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand. 5 MB15E05SL ■ ELECTRICAL CHARACTERISTICS (VCC = 2.4 to 3.6 V, Ta = –40 to +85°C) Parameter Symbol Condition Power supply current*1 ICC Power saving current Operating frequency Input sensitivity “H” level input voltage “L” level input voltage “H” level input current “L” level input current “H” level input current “L” level input current “H” level input current “L” level input current “L” level output voltage Unit Min. Typ. Max. fin = 2000 MHz, VCC = VP = 2.7 V (VCC = VP = 3.0 V) – 3.0 (3.5) – mA IPS ZC = “H” or open – 0.1*2 10 µA fin fIN – 100 – 2000 MHz OSCIN fosc – 3 – 40 MHz fin*3 Pfin –15 – +2 dBm OSCIN*3 VOSC – 0.5 – VCC Vp-p Data, Clock, LE, PS, ZC VIH – VCC × 0.7 – – VIL – – – VCC × 0.3 Data, Clock, LE, PS IIH*4 – –1.0 – +1.0 IIL*4 – –1.0 – +1.0 IIH – 0 – +100 I IL*4 – –100 – 0 IIH*4 – –1.0 – +1.0 –100 – 0 – – 0.4 VCC – 0.4 – – – – 0.4 OSCIN ZC φP I IL*4 50 Ω system (Refer to the measurement circuit.) Pull up input V µA µA µA VOL Open drain output φR, “L” level output voltage LD/fout VOH VCC = VP = 3.0 V, IOH = –1 mA VOL VCC = VP = 3.0 V, IOL = 1 mA “H” level output voltage VDOH VCC = VP = 3.0 V, IDOH = –0.5 mA VP – 0.4 – – VDOL VCC = VP = 3.0 V, IDOL = 0.5 mA – – 0.4 – – 2.5 nA 1.0 – – mA “H” level output voltage “L” level output voltage Do High impedance cutoff current Do IOFF VCC = VP = 3.0 V, VOFF = 0.5 V to VP – 0.5 V “L” level output current φP IOL Open drain output “H” level output current φR, “L” level output current LD/fout “H” level output current V – – –1.0 IOL – 1.0 – – CS bit = “H” – –6.0 – CS bit = “L” – –1.5 – CS bit = “H” – 6.0 – CS bit = “L” – 1.5 – – 3 – % – 10 – % – 10 – % IDOL VCC = 3 V, VP = 3 V, VDO = VP/2, Ta = +25°C IDOL/IDOH IDOMT*5 VDO = VP/2 Charge pump current rate V – IDOH*4 “L” level output current V IOH Do 6 Value vs VDO IDOVD*6 0.5 V ≤ VDO ≤ VP – 0.5 V vs Ta IDOTA*7 – 40°C ≤ Ta ≤ +85°C mA mA MB15E05SL *1: *2: *3: *4: *5: *6: *7: Conditions; fosc = 12 MHz, Ta = +25°C, in locking state. VCC = VP = 3.0 V, fosc = 12.8 MHz, Ta = +25°C, in power saving mode AC coupling. 1000 pF capacitor is connected under the condition of min. operating frequency. The symbol “–” (minus) means direction of current flow. VCC = VP = 3.0 V, Ta = +25°C (|I3| – |I4|) / [(|I3| + |I4|) /2] × 100(%) VCC = VP = 3.0 V, Ta = +25°C [(|I2| – |I1|) /2] / [(|I1| + |I2|) /2] × 100(%) (Applied to each IDOL, IDOH) VCC = VP = 3.0 V, VDO = VP/2 (|IDO(+85°C) – IDO(–40°C)| /2) / (|IDO(+85°C) + IDO(–40°C)| /2) × 100(%) (Applied to each IDOL, IDOH) I1 I3 I2 IDOL IDOH I4 I2 I1 0.5 VP/2 VP − 0.5 VP Charge Pump Output Voltage (V) 7 MB15E05SL ■ FUNCTIONAL DESCRIPTION 1. Pulse Swallow Function The divide ratio can be calculated using the following equation: fVCO = [(M × N) + A] × fOSC ÷ R (A < N) fVCO : Output frequency of external voltage controlled oscillator (VCO) N : Preset divide ratio of binary 11-bit programmable counter (3 to 2,047) A : Preset divide ratio of binary 7-bit swallow counter (0 ≤ A ≤ 127) fOSC : Output frequency of the reference frequency oscillator R : Preset divide ratio of binary 14-bit programmable reference counter (3 to 16,383) M : Preset divide ratio of modulus prescaler (64 or 128) 2. Serial Data Input Serial data is processed using the Data, Clock, and LE pins. Serial data controls the programmable reference divider and the programmable divider separately. Binary serial data is entered through the Data pin. One bit of data is shifted into the shift register on the rising edge of the Clock. When the LE signal pin is taken high, stored data is latched according to the control bit data as follows: Table 1. Control Bit Control bit (CNT) Destination of serial data H For the programmable reference divider L For the programmable divider (1) Shift Register Configuration Programmable Reference Counter MSB LSB Data Flow 1 2 3 4 5 6 7 8 9 CNT R1 R2 R3 R4 R5 R6 R7 R8 CNT R1 to R14 SW FC LDS CS 11 12 13 14 15 16 R9 R10 R11 R12 R13 R14 SW : Control bit : Divide ratio setting bit for the programmable reference counter (3 to 16,383) : Divide ratio setting bit for the prescaler (64/65 or 128/129) : Phase control bit for the phase comparator : LD/fOUT signal select bit : Charge pump current select bit Note: Start data input with MSB first. 8 10 17 18 19 FC LDS CS [Table 1] [Table 2] [Table 5] [Table 8] [Table 7] [Table 6] MB15E05SL Programmable Counter MSB LSB Data Flow 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 CNT A1 A2 A3 A4 A5 A6 A7 N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 N11 CNT : Control bit N1 to N11: Divide ratio setting bits for the programmable counter (3 to 2,047) A1 to A7 : Divide ratio setting bits for the swallow counter (0 to 127) 18 19 [Table 1] [Table 3] [Table 4] Note: Data input with MSB first. Table 2. Binary 14-bit Programmable Reference Counter Data Setting Divide ratio(R) R14 R13 R12 R11 R10 R9 R8 R7 R6 R5 R4 R3 R2 R1 3 0 0 0 0 0 0 0 0 0 0 0 0 1 1 4 0 0 0 0 0 0 0 0 0 0 0 1 0 0 ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ 16383 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Note: Divide ratio less than 3 is prohibited. Table 3. Binary 11-bit Programmable Counter Data Setting Divide ratio(N) N11 N10 N9 N8 N7 N6 N5 N4 N3 N2 N1 3 0 0 0 0 0 0 0 0 0 1 1 4 0 0 0 0 0 0 0 0 1 0 0 ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ 2047 1 1 1 1 1 1 1 1 1 1 1 Note: Divide ratio less than 3 is prohibited. 9 MB15E05SL Table 4. Binary 7-bit Swallow Counter Data Setting Divide ratio(A) A7 A6 A5 A4 A3 A2 A1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ ⋅ 127 1 1 1 1 1 1 1 Table 5. Prescaler Data Setting SW Prescaler divide ratio H 64/65 L 128/129 Table 6. Charge Pump Current Setting CS Current value H ±6.0 mA L ±1.5 mA Table 7. LD/fout Output Select Data Setting LDS LD/fout output signal H fout signal L LD signal (2) Relation between the FC Input and Phase Characteristics The FC bit changes the phase characteristics of the phase comparator. Both the internal charge pump output level (DO) and the phase comparator output (φR, φP) are reversed according to the FC bit. Also, the monitor pin (fout) output is controlled by the FC bit. The relationship between the FC bit and each of DO, φR, and φP is shown below. Table 8. FC Bit Data Setting (LDS = “H”) FC = High DO φR φP fr > fP H L L fr < fP L H Z* fr = fP Z* L Z* * : High impedance 10 FC = Low LD/fout fout = fr DO φR φP L H Z* H L L Z* L Z* LD/fout fout = fp MB15E05SL When designing a synthesizer, the FC pin setting depends on the VCO and LPF characteristics. • When the LPF and VCO characteristics are similar to (1), set FC bit high. • When the VCO characteristics are similar to (2), set FC bit low. (1) VCO Output Frequency PLL LPF VCO (2) LPF Output Voltage 3. Do Output Control Table 9. ZC Pin Setting ZC pin Do output H Normal output L High impedance 4. Power Saving Mode (Intermittent Mode Control Circuit) Table 10. PS Pin Setting PS pin Status H Normal mode L Power saving mode The intermittent mode control circuit reduces the PLL power consumption. By setting the PS pin low, the device enters into the power saving mode, reducing the current consumption. See the Electrical Characteristics chart for the specific value. The phase detector output, Do, becomes high impedance. For the signal PLL, the lock detector, LD, remains high, indicating a locked condition. Setting the PS pin high, releases the power saving mode, and the device works normally. The intermittent mode control circuit also ensures a smooth startup when the device returns to normal operation. When the PLL is returned to normal operation, the phase comparator output signal is unpredictable. This is because of the unknown relationship between the comparison frequency (fp) and the reference frequency (fr) which can cause a major change in the comparator output, resulting in a VCO frequency jump and an increase in lockup time. To prevent a major VCO frequency jump, the intermittent mode control circuit limits the magnitude of the error signal from the phase detector when it returns to normal operation. Note: When power (VCC) is first applied, the device must be in standby mode, PS = Low, for at least 1 µs. 11 MB15E05SL Note: • PS pin must be set “L” for Power-ON. OFF ON tV ≥ 1 µs VCC Clock Data LE tPS ≥ 100 ns PS (1) (2) (3) (1) PS = L (power saving mode) at Power ON (2) Set serial data 1 µs later after power supply remains stable (VCC > 2.2 V). (3) Release power saving mode (PS: “L” → “H”) 100 ns later after setting serial data. 12 MB15E05SL ■ SERIAL DATA INPUT TIMING 1st data 2nd data Control bit Invalid data ∼ Data MSB LSB ∼ ∼ Clock t1 t2 t3 t6 t7 LE ∼ t4 t5 On the rising edge of the clock, one bit of data is transferred into the shift register. Parameter Min. Typ. Max. Unit Parameter Min. Typ. Max. Unit t1 20 – – ns t5 100 – – ns t2 20 – – ns t6 20 – – ns t3 30 – – ns t7 100 – – ns t4 30 – – ns Note: LE should be “L” when the data is transferred into the shift register. 13 MB15E05SL ■ PHASE COMPARATOR OUTPUT WAVEFORM fr fp t WU t WL LD [FC = “H”] DO [FC = “L”] DO Notes: • Phase error detection range: –2π to +2π • Pulses on Do signal during locked state are output to prevent dead zone. • LD output becomes low when phase is tWU or more. LD output becomes high when phase error is tWL or less and continues to be so for three cycles or more. • tWU and tWL depend on OSCIN input frequency. tWU > 2/fosc (s) (e. g. tWU > 156.3 ns, fosc = 12.8 MHz) tWU < 4/fosc (s) (e. g. tWL < 312.5 ns, fosc = 12.8 MHz) • LD becomes high during the power saving mode (PS = “L”). 14 MB15E05SL ■ MEASURMENT CIRCUIT (for Measuring Input Sensitivity fin/OSCIN) 1000 pF 0.1 µF 1000 pF 0.1 µF 1000 pF S.G. S.G. 50 Ω fin Xfin GND DO VCC VP OSCOUT OSCIN 8 7 6 5 4 3 2 1 9 10 11 12 13 14 15 16 Clock Data LE PS ZC LD/fout φP φR VCC 50 Ω Oscilloscope Controller (setting divide ratio) Note: SSOP-16 15 MB15E05SL ■ TYPICAL CHARACTERISTICS 1. fin input sensitivity Input sensitivity − Input frequency Input sensitivity Pfin (dBm) 10 Ta = +25 °C ,,,,,,,,,,,,,,, ,,,,,,,,,,,,,,, ,,,,,,,,,,,,,,, 0 SPEC −10 −20 VCC = 2.4 V −30 VCC = 2.7 V VCC = 3.0 V −40 VCC = 3.6 V −50 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 Input frequency fin (MHz) 2. OSCIN input sensitivity 10 ,,,,,, ,,,,,, Input sensitivity − Input frequency Ta = +25 °C Input sensitivity VOSC (dBm) SPEC 0 −10 −20 −30 −40 VCC = 2.4 V VCC = 3.0 V −50 VCC = 3.6 V −60 0 16 50 100 Input frequency fOSC (MHz) 150 200 MB15E05SL 3. Do output current 1.5 mA mode VDO − IDO Ta = +25 °C VCC = 3.0 V VP = 3.0 V Charge pump output current IDO (mA) 10.00 2.000 /div IDOL 0 IDOH −10.00 0 VO .6000/div (V) Charge pump output voltage VDO (V) 6.0 mA mode 4.800 VDO − IDO Ta = +25 °C VCC = 3.0 V VP = 3.0 V Charge pump output current IDO (mA) 10.00 IDOL 2.000 /div 0 IDOH −10.00 0 VO .6000/div (V) Charge pump output voltage VDO (V) 4.800 17 MB15E05SL 4. fin input impedance 1 : 20.219 Ω −161.11 Ω 500 MHz 2: 9.625 Ω −64.082 Ω 1 GHz 3 : 17.807 Ω −23.918 Ω 1.5 GHz 4 : 30.647 Ω −18.134 Ω 2.0 GHz 4 3 1 2 START 100.000 000 MHz STOP 2 000.000 000 MHz 5. OSCIN input impedance 1 : 8.0005 kΩ −1.9708 kΩ 3 MHz 2 : 4.1825 kΩ −3.9273 kΩ 10 MHz 3 : 1.8909 kΩ −3.2791 kΩ 4 20 MHz 3 573 Ω 12 4 : −1.9271 kΩ 40 MHz START 18 3.000 000 MHz STOP 40.000 000 MHz MB15E05SL ■ REFERENCE INFORMATION Test Circuit S.G. OSCIN fin Spectrum Analyzer fVCO = 1607 MHz KV = 28 MHz/V fr = 25 kHz fOSC = 14.4 MHz LPF LPF Do 3300 pF VCO VCC =VP = 3.0 V VVCO = 2.1 V Ta = +25 °C CP : 6 mA mode 9.1 kΩ 5.6 kΩ 1500 pF 33000 pF PLL Reference Leakage ATTEN 10 dB RL −10.0 dBm 10 dB/ ∆MKR −70.50 dB 25.0 kHz CENTER 1.6070000 GHz VBW 1.0 kHz RBW 1.0 kHz SPAN 200.0 kHz SWP 500 ms PLL Phase Noise ATTEN 10 dB RL −10.0 dBm 10 dB/ CENTER 1.6070000 GHz VBW 100 Hz RBW 100 Hz ∆MKR −45.00 dB 2.20 kHz SPAN 20.00 kHz SWP 1.60 s (Continued) 19 MB15E05SL (Continued) PLL Lock Up time PLL Lock Up time 1607 MH→1631 MHz within ± 1 kHz Lch→Hch 1.46 ms 1631 MH→1607 MHz within ± 1 kHz Hch→Lch 1.37 ms 1.631005000 GHz 1.607005000 GHz 1.631001000 GHz 1.607001000 GHz 1.630097000 GHz 1.606997000 GHz 500.0 µs/div 500.0 µs/div 1.67100 GHz 1.64700 GHz 1.63100 GHz 1.60700 GHz 1.59100 GHz 1.56700 GHz 500.0 µs/div 20 500.0 µs/div MB15E05SL ■ APPLICATION EXAMPLE VP 10 kΩ OUTPUT VCO LPF 12 kΩ 12 kΩ 10 kΩ Lock Det. From a controller φR φP LD/fout ZC PS LE Data Clock 16 15 14 13 12 11 10 9 MB15E05SL 1 2 3 4 5 6 7 8 OSCIN OSCOUT VP VCC DO GND Xfin fin 1000 pF 1000 pF 1000 pF 0.1 µF 0.1 µF TCXO VP: 5.5 V Max Notes: • SSOP-16 • In case of using a crystal resonator, it is necessary to optimize matching between the crystal and this LSI, and perform detailed system evaluation. It is recommended to consult with a supplier of the crystal resonator. (Reference oscillator circuit provides its own bias, feedback resistor is 100 kΩ (typ).) ■ USAGE PRECAUTIONS To protect against damage by electrostatic discharge, note the following handling precautions: -Store and transport devices in conductive containers. -Use properly grounded workstations, tools, and equipment. -Turn off power before inserting device into or removing device from a socket. -Protect leads with a conductive sheet when transporting a board-mounted device. 21 MB15E05SL ■ ORDERING INFORMATION Part number 22 Package MB15E05SLPFV1 16-pin, Plastic SSOP (FPT-16P-M05) MB15E05SLPV1 16-pad, Plastic BCC (LCC-16P-M06) Remarks MB15E05SL ■ PACKAGE DIMENSIONS 16-pin, Plastic SSOP (FPT-16P-M05) Note 1) * : These dimensions do not include resin protrusion. Note 2) Pins width and pins thickness include plating thickness. * 5.00±0.10(.197±.004) 0.17±0.03 (.007±.001) 9 16 * 4.40±0.10 6.40±0.20 (.173±.004) (.252±.008) INDEX Details of "A" part +0.20 1.25 –0.10 +.008 .049 –.004 LEAD No. 1 8 0.65(.026) 0.10(.004) C (Mounting height) 1999 FUJITSU LIMITED F16013S-3C-5 "A" 0.24±0.08 (.009±.003) 0.13(.005) M 0~8° 0.50±0.20 (.020±.008) 0.45/0.75 (.018/.030) 0.10±0.10 (Stand off) (.004±.004) 0.25(.010) Dimensions in mm (inches) (Continued) 23 MB15E05SL (Continued) 16-pad plastic BCC (LCC-16P-M06) 4.55±0.10 (.179±.004) 0.80(.031)MAX Mounting height 14 3.40(.134)TYP 0.65(.026) TYP 0.40±0.10 (.016±.004) 9 0.325±0.10 (.013±.004) 9 14 0.80(.031) REF INDEX AREA 3.40±0.10 (.134±.004) 2.45(.096) TYP "A" 1 6 0.075±0.025 (.003±.001) (Stand off) 6 Details of "A" part 0.75±0.10 (.030±.004) 1.15(.045) REF "B" 1.725(.068) REF 1 Details of "B" part 0.60±0.10 (.024±.004) 0.05(.002) 0.40±0.10 (.016±.004) C 24 1999 FUJITSU LIMITED C16017S-1C-1 0.60±0.10 (.024±.004) Dimensions in mm (inches) MB15E05SL FUJITSU LIMITED For further information please contact: Japan FUJITSU LIMITED Corporate Global Business Support Division Electronic Devices KAWASAKI PLANT, 4-1-1, Kamikodanaka, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8588, Japan Tel: +81-44-754-3763 Fax: +81-44-754-3329 http://www.fujitsu.co.jp/ North and South America FUJITSU MICROELECTRONICS, INC. 3545 North First Street, San Jose, CA 95134-1804, USA Tel: +1-408-922-9000 Fax: +1-408-922-9179 Customer Response Center Mon. - Fri.: 7 am - 5 pm (PST) Tel: +1-800-866-8608 Fax: +1-408-922-9179 http://www.fujitsumicro.com/ Europe FUJITSU MICROELECTRONICS EUROPE GmbH Am Siebenstein 6-10, D-63303 Dreieich-Buchschlag, Germany Tel: +49-6103-690-0 Fax: +49-6103-690-122 http://www.fujitsu-fme.com/ Asia Pacific FUJITSU MICROELECTRONICS ASIA PTE LTD #05-08, 151 Lorong Chuan, New Tech Park, Singapore 556741 Tel: +65-281-0770 Fax: +65-281-0220 http://www.fmap.com.sg/ F0002 FUJITSU LIMITED Printed in Japan All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information and circuit diagrams in this document are presented as examples of semiconductor device applications, and are not intended to be incorporated in devices for actual use. Also, FUJITSU is unable to assume responsibility for infringement of any patent rights or other rights of third parties arising from the use of this information or circuit diagrams. The contents of this document may not be reproduced or copied without the permission of FUJITSU LIMITED. FUJITSU semiconductor devices are intended for use in standard applications (computers, office automation and other office equipments, industrial, communications, and measurement equipments, personal or household devices, etc.). CAUTION: Customers considering the use of our products in special applications where failure or abnormal operation may directly affect human lives or cause physical injury or property damage, or where extremely high levels of reliability are demanded (such as aerospace systems, atomic energy controls, sea floor repeaters, vehicle operating controls, medical devices for life support, etc.) are requested to consult with FUJITSU sales representatives before such use. The company will not be responsible for damages arising from such use without prior approval. Any semiconductor devices have inherently a certain rate of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Control Law of Japan, the prior authorization by Japanese government should be required for export of those products from Japan.