TI 74ACT11257DW

74ACT11257
QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
WITH 3-STATE OUTPUTS
SCAS053B – JANUARY 1989 – REVISED APRIL 1996
D
D
D
D
D
D
D
D
Inputs Are TTL-Voltage Compatible
3-State Outputs Interface Directly With
System Bus
Flow-Through Architecture Optimizes
PCB Layout
Center-Pin VCC and GND Configurations
Minimize High-Speed Switching Noise
EPICt (Enhanced-Performance Implanted
CMOS) 1-mm Process
500-mA Typical Latch-Up Immunity at
125°C
Provides Bus Interface From Multiple
Sources in High-Performance Systems
Package Options Include Plastic
Small-Outline (DW) and Shrink
Small-Outline (DB) Packages, and Standard
Plastic 300-mil DIPs (N)
DB, DW, OR N PACKAGE
(TOP VIEW)
A /B
1Y
2Y
GND
GND
GND
GND
3Y
4Y
OE
1
20
2
19
3
18
4
17
5
16
6
15
7
14
8
13
9
12
10
11
1A
1B
2A
2B
VCC
VCC
3A
3B
4A
4B
description
The 74ACT11257 is designed to multiplex signals from 4-bit data sources to four output data lines in
bus-organized systems. The 3-state outputs do not load the data lines when the output-enable (OE) input is at
a high logic level.
The 74ACT11257 is characterized for operation from –40°C to 85°C.
FUNCTION TABLE
INPUTS
OUTPUT
Y
DATA
OE
SELECT
A/B
A
B
H
X
X
X
L
L
L
X
L
L
L
H
X
H
L
H
X
L
L
L
H
X
H
H
Z
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1996, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
74ACT11257
QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
WITH 3-STATE OUTPUTS
SCAS053B – JANUARY 1989 – REVISED APRIL 1996
logic symbol†
OE
A/B
1A
1B
2A
2B
3A
3B
4A
4B
10
1
20
19
18
EN
G1
1
MUX
2
1Y
1
3
17
14
8
13
12
9
11
2Y
3Y
4Y
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
logic diagram (positive logic)
OE
A/B
1A
1B
2A
2B
3A
3B
4A
4B
2
10
1
20
2
1Y
19
18
3
2Y
17
14
8
3Y
13
12
9
11
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
4Y
74ACT11257
QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
WITH 3-STATE OUTPUTS
SCAS053B – JANUARY 1989 – REVISED APRIL 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 2): DB package . . . . . . . . . . . . . . . . . . . 0.6 W
DW package . . . . . . . . . . . . . . . . . . 1.6 W
N package . . . . . . . . . . . . . . . . . . . . 1.3 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150_C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
recommended operating conditions
MIN
MAX
4.5
5.5
VCC
VIH
Supply voltage
VIL
VI
Low-level input voltage
Input voltage
0
VO
IOH
Output voltage
0
High-level input voltage
2
UNIT
V
V
0.8
V
VCC
VCC
V
High-level output current
–24
mA
IOL
Dt/Dv
Low-level output current
24
mA
0
10
ns/V
TA
Operating free-air temperature
–40
85
°C
Input transition rise or fall rate
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
V
3
74ACT11257
QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
WITH 3-STATE OUTPUTS
SCAS053B – JANUARY 1989 – REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETERS
TEST CONDITIONS
VCC
4.5 V
IOH = –50
50 mA
VOH
24 mA
IOH = –24
IOH = –75 mA{
IOZ
II
IOL = 24 mA
IOL = 75 mA{
VO = VCC or GND
ICC
VI = VCC or GND
VI = VCC or GND,
DICC‡
One input at 3.4 V,
Ci
TA = 25°C
TYP
MAX
MIN
4.4
4.4
5.5 V
5.4
5.4
4.5 V
3.94
3.8
5.5 V
4.94
MAX
UNIT
V
4.8
5.5 V
IOL = 50 mA
VOL
MIN
3.85
4.5 V
0.1
5.5 V
0.1
0.1
0.1
4.5 V
0.36
0.44
5.5 V
0.36
0.44
5.5 V
V
1.65
5.5 V
±0.5
±5
mA
5.5 V
±0.1
±1
mA
IO = 0
5.5 V
8
80
mA
Other inputs at VCC or GND
5.5 V
0.9
1
mA
VI = VCC or GND
VO = VCC or GND
5V
3.5
pF
Co
5V
8
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V to VCC.
pF
switching characteristics over recomended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
Y
tPLH
tPHL
A /B
Any Y
tPZH
tPZL
OE
Any Y
tPHZ
tPLZ
OE
Any Y
MIN
TA = 25°C
TYP
MAX
MIN
MAX
1.5
4.4
6.4
1.5
6.9
1.5
5
8
1.5
8.7
1.5
4.7
7.6
1.5
8.2
1.5
5.7
8.5
1.5
9.4
1.5
4.2
6.9
1.5
7.3
1.5
5.5
8.7
1.5
9.6
1.5
5.7
7.6
1.5
8.4
1.5
6
7.9
1.5
8.5
UNIT
ns
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
d
4
TEST CONDITIONS
Outputs enabled
Power dissipation capacitance
Outputs disabled
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
pF
CL = 50 pF,
f = 1 MHz
TYP
41
13
UNIT
pF
74ACT11257
QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
WITH 3-STATE OUTPUTS
SCAS053B – JANUARY 1989 – REVISED APRIL 1996
PARAMETER MEASUREMENT INFORMATION
2 × VCC
S1
500 Ω
From Output
Under Test
Open
GND
CL = 50 pF
(see Note A)
TEST
S1
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
Open
2 × VCC
GND
500 Ω
LOAD CIRCUIT
Output
Control
(low-level
enabling)
3V
Input
1.5 V
1.5 V
0V
tPHL
tPLH
In-Phase
Output
50% VCC
50% VCC
0V
tPZL
VOH
50% VCC
VOL
Output
Waveform 2
S1 at GND
(see Note B)
[ VCC
tPLZ
Output
Waveform 1
S1 at 2 × VCC
(see Note B)
tPLH
tPHL
Out-of-Phase
Output
VOH
50% VCC
VOL
3V
1.5 V
1.5 V
50% VCC
VOL
tPHZ
tPZH
VOLTAGE WAVEFORMS
20% VCC
50% VCC
80% VCC
VOH
[0V
VOLTAGE WAVEFORMS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
D. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated