1.0 INTRODUCTIONS
MPE-902M is 20Watts, universal AC input switching power supply. This model has over-voltage
crowbar protection in main output.
2.0 INPUT SPECIFICATIONS
2.1 Input Voltage
The range of input voltage is from 85VAC to 260VAC.
2.2
Input frequency
The range of input frequency is from 47Hz to 63Hz.
2.3
Input current
The maximum input current is 1A at 115V AC or 0.6A at 230VAC.
2.4
Inrush current
The inrush current will not exceed 20A at 115VAC input or 40A at 230VAC input, cold start,
25℃.
3.0 OUTPUT SPECIFICATIONS
3.1 Load range
Output voltage Min. load Rated load Peak load
Voltage accuracy
+5V
0A
1.5A
2.5A
4.95V to 5.05V
+12V
0A
1A
1.5A
11.4V to 12.6V
At factory, both outputs in 60% rated load condition; the +5V output is set to between 4.95V
and 5.05V, and +12V is checked to be within the specified voltage accuracy range.
3.2
Ripple and noise
The peak to peak ripple and noise is less than +/-1% of output voltage at rated load.
Measuring is done by 15MHz bandwidth limited oscilloscope and terminated the output with
a 0.47µF capacitor.
3.3
Line regulation
The line regulation is less than +/-1% when measuring at rated load and +/-10% of input
voltage changing.
3.4
Load regulation
The load regulation for +5V is less than +/-1%, for +12V is less than +/-4%, measuring is
done by changing the output load +/-40% from 60% rated load, and keep the other output at
60% rated load.
Proprietary Information
Magic Power Technology Co., Ltd.
2
MPE-902M Specification
902M-031703
4.0 GENERAL FEATURES
4.1 Efficiency
The efficiency is 75% typical while measuring at nominal line and rated load.
4.2
Hold up time
The hold up time is longer than 16mS at 115VAC input and rated load.
4.3 Protection
For some reasons the power supply might fail to control itself, the build-in over voltage
protection circuit will shut down the outputs to prevent damaging external circuits. The trip
point of crowbar circuit is around 5.7V to 6.7V. The power supply will go into hiccup mode
against short circuit or over load conditions, and will auto-recovery while faulty conditions
are removed.
5.0 ENVIRONMENT SPECIFICATIONS
5.1 Operating temperature
0 ℃ to 50℃
5.2
Storage temperature
-20℃ to 85℃
5.3 Altitude
Will operate properly at any altitude between 0 to 10000 ft.
6.0
INTERNATIONAL STANDARDS
6.1 Safety standards
Designed to meet the following standards:
UL 1950 D3
CSA 22.2 No.234
EN 60950
6.2
EMI standards
Designed to meet the following conducted limits:
FCC docket 20780 curve ”B”
Proprietary Information
Magic Power Technology Co., Ltd.
3
MPE-902M Specification
902M-031703
7.0 MECHANICAL SPECIFICATION
7.1 Dimensions
Dimensions are shown in mm (inch) as above. Tolerance specified is +/-0.4mm.
7.2 Connectors
TB1—AC input
TB2—DC output
:
:
Molex 5277-2 or equivalent.
AMP 1-480424-0 or equivalent.
7.3 Wire color vs. output voltage
Yellow - +12V
Red
- +5V
Black - GND
Proprietary Information
Magic Power Technology Co., Ltd.
4