BOSER MPE-FT40-02

MPE-FT40-02
40W Triple Outputs AC-DC Open Frame
Power Supply
4.45
5.08
9.53
Industrial Power Supply
10.16
3.048
AC-DC
Features
Safety Standards
*Safety: UL 1950 / TUV EN60950 / CE mark
*Input Voltage: The range of input voltage is from
*EMI: EN55022 class B / CISPR FCC class B
90~264VAC or 120~370VDC
*Input Frequency: 47~440Hz
*Input Current: The maximum input current is 1A(RMS) at
115VAC
Output
PIN
*Inrush Current: The cold inrush current will limit less than
+12V
1
50A at 264VAC input voltage
+5V
2
*Load Range: Voltage accuracy is set at full load. Maximum
+5V
3
output power is 42.6W
COM
4
*Ripple And Noise: The peak to peak ripple and noise for +5V
COM
5
output is less than 50mV, 120mV for +/-12V outputs.
6
-12V
Measuring is done by 20MHz bandwidth limited oscilloscope
and terminated each output with a 0.1uF ceramic capacitor and
Output Min. Rated Max.
Voltage
a 10uF electrolysis capacitor at rated load, nominal line
Voltage Load Load
Load
Accuracy
*Line Regulation: The line regulation for +5V and -12V is less
+5V
0.4A 3.0A
5.0A
4.85~5.15V
than +/-1%, +/-2% for +12V
+12V 0.2A 2.0A
2.5A 11.52~12.48V
*Load Regulation: The load regulation for +5V output is less
-12V
0A
0.3A
0.5A 11.64~12.36V
than +/-3%, +/-5% for +12V, and +/-1% for -12V. Measuring
is measured from 60% to 100% and 60% to 20% with full load
(60% +/-40% full load)
*Hold Up Time: Hold up time is 20mS typical at 115VAC input
*Efficiency: The efficiency is 75% typical while measuring is at
nominal line and rated load
*Over Voltage Protection: The trip point of crowbar circuit is
around 5.7~6.7V for +5V output and 14.4~16.8V for +12V.
The power supply will go into hiccup mode against short circuit
or over load conditions, and will do auto-recovery while faulty
conditions are removed
*Temperature: 0~+50oC (operating); -20~+85oC (storage)
*Humidity: 5~95% non-condensing
*Connectors:
I/P Connector: Molex 5277 or equivalent
O/P Connector: Molex 5273 or equivalent
*Dimensions: 10.16 x 5.08 x 3.048 cm
www.boser.com.tw