BOSER BPW-8110

120W DC-DC Open Frame Power Supply
8.38
6.89
0.745
14.16
15.24
14.44
6.86
Features
1.395
*Input Voltage: The range of input voltage is from 10~30VDC,
nominal input voltage is 12 and 24VDC
*Input Current: 18A at 10VDC max.
*Inrush Current: Less than 30A at 10VDC input
*Load Range: At the factory, the +5V output is set between
5.08~5.13V and all output at 60% rated load; the other
outputs are checked to be within the accuracy range. The
maximum total combined output power on the +3.3V and +5V
rails is 70W. The max. load cannot exceed 120W
*Ripple and Noise: The peak to peak ripple and noise for +5V, *Safety: UL 1950 / CSA 22.2 No.234 / EN60950
*EMI: FCC class B / EN55022 B
+3.3V output are less than 100mV for +5Vsb is 120mV, for
*EMS: IEC 61000-4-2/3/4 Level 3
+12V is less than 120mV, for -12V is less than 200mV at
ranted load and nominal input, which is measured by a 20MHz
bandwidth limited oscilloscope and the each output is
Output Min. Rated Max.
Voltage
connected with a 0.47uF capacitor
Voltage Load Load
Load
Accuracy
*Line Regulation: Less than +/-2.5% at rated load with
+5V
1A
2.5A
5A
4.95~5.15V
+/-10% change in input voltage
+12V
0A
5A
7A 11.25~12.75V
-12V
0A
0.5A
1A -11.75~-13.1V
*Load Regulation: +5V is less than +/-2%, for +12V is less
+3.3V
0A
2.5A
5A
3.0~3.5V
than +/-5%, for -12V +/-5%, +3.3V is less than +/-5% while
+5Vsb
0A
0.75A
---4.8~5.2V
the measuring is done by changing the measured output
loading +/-40% from 60% rated load, and keep other output is
at 60% rated load
*Efficiency: > 70% while measuring at nominal line and rated
load
*Altitude: 0~10,000 ft.
*Protection: The power supply will generate the hiccup mode
to protect itself against short circuit or over load condition, and
will return to normal after wrong condition is removed
*Power On/Off: The power supply will start-up when the
power on/off pin be connected to secondary GND
*Power Good Signal: The power is turned on, the power good
signal will go high between 100ms to 500ms after all output
DC voltage are within regulation limits
*Power Fail Signal: The power fail signal will go low at least
1ms before any of the output voltages fall below the regulation
limits
*Temperature: 0~+50oC, output power is 120W forced air
cooling, 85W convection cooling (operating); -20~+70oC
(storage)
*Humidity: 10~90%, non-condensing
*Connectors:
DC Input (CN1): Dinkle DT-35-B01W-03 or equivalent
DC Output (CN2): Molex 5273-14A or equivalent
DC Output (CN3): Molex 5045-03A or equivalent
Power Good Output (CN4): Molex 5045-02A or equivalent
Fan Output (CN5): Molex 5045-02A or equivalent
*Dimensions: 15.24 x 8.38 x 3.8 cm with +/-0.4mm tolerance
Safety Standards
www.boser.com.tw
DC-DC
6.86
0.45
3.8
0.2
Industrial Power Supply
0.54
0.76
BPW-8110