ETC MPD-810H

Industrial
Power Supply
MPD-810H
14.16
8.38
6.89
0.745
0.54
0.76
120W 10~30VDC DC/DC ATX Open Frame Power Supply
15.24
14.44
0.2
1.395
6.86
6.86
0.45
3.8
Features
Safety Standards
*Safety: UL 1950 / CSA 22.2 No.234 / VDE EN60 950
*EMI: FCC Class B / EN55022B
*EMS: Level 3 of IEC-801, 802, 803, 804 / UL 1950 / CSA
22.2 No.234 / VDE EN 60 950
Connectors
Output
GND
PW Good
Output Min.
Voltage Load
+5V
1A
+12V
0A
-12V
0A
+3.3V
0A
+5Vsb 0.1A
Rated
Load
8A
1.5A
0.5A
5A
0.75A
CN3
PIN
1
2
3
Output
PW On/Off
GND
5Vsb
CN5 (for Fan)
PIN
Output
1
GND
2
+12V
a
d
F
r
RoHS
e
CN4
PIN
1
2
Output
+5V
GND
+12V
3.3V
-12V
Le
CN2
PIN
1~3
4~8
9~10
11~13
14
e
*Input Voltage: The range of input voltage is from
10~30VDC, nominal input voltage is 12 and 24VDC
*Input Current: The maximum is 18A at 10VDC input
*Inrush Current: The inrush current is less than 30A at
10VDC input
*Load Range: At the factory, the +5V output is set between
5.08V to 5.13V and all output at 60% rated load; the other
outputs are checked to be within the accuracy range. The
maximum total combined output power on the +3.3V and
+5V rails is 70W. The max. load cannot exceed 120W
*Ripple And Noise: The peak to peak ripple and noise for
+5V, +3.3V output are less than 100mV for +5Vsb is
120mV, for +12V is less than 120mV, for -12V is less than
200mV at ranted load and nominal input, which is measured
by a 20MHz bandwidth limited oscilloscope and the each
output is connected with a 0.47uF capacitor
*Line Regulation: The line regulation is less than +/-2.5% at
rated load with +/-10% change in input voltage
*Load Regulation: The load regulation for +5V is less than
+/-2 %, for +12V is less than +/-5%, for -12V +/-5%, +
3.3V is less than +/-5% while the measuring is done by
changing the measured output loading +/-40% from 60%
rated load, and keep other output is at 60% rated load
*Power On/Off: The power supply will start-up when the
power On/Off pin be connected to secondary GND
*Power Good Signal: The power is turned on, the power
good signal will go high between 100ms to 500ms after all
output DC voltage are within regulation limits
*Power Fail Signal: The power fail signal will go low at least
1ms before any of the output voltages fall below the
regulation limits
*Efficiency: The efficiency is higher than 70% while
measuring at nominal line and rated load
*Altitude: Will operate properly at any altitude between 0 to
10000ft
*Protection: The power supply will generate the hiccup mode
to protect itself against short circuit or over load condition,
and will return to normal after wrong condition is removed
*Temperature: 0~50oC, output power is 120W forced air
cooling, 80W convection cooling (operating); -20~+70oC
(storage)
*Humidity: 10~90% non-condensing
*Connectors:
DC Input: Dinkle DT-35-B01W-03 or equivalent
DC Output: Molex 5273-14A or equivalent
DC Output: Molex 5045-03A or equivalent
Power Good Output: Molex 5045-02A or equivalent
Fan Output: Molex 5045-02A or equivalent
*Dimensions: 8.38 x 15.24 x 3.81 cm; tolerance specified is
+/-0.4mm
Max.
Voltage
Load
Accuracy
10A
4.95~5.15V
4A 11.25~12.75V
1A -11.75~-13.1V
8A
3~3.5V
---4.8~5.2V
ISO 19001
4 001
Certification
15F-6, No. 77, Hsin Tai Wu Road, Sec. 1, Hsichih, Taipei Hsien 221 Taiwan TEL: 886-2-26983333 FAX: 886-2-26983300
http://www.boser.com.tw / http://www.bosertech.com E-mail: [email protected] / [email protected]
ShangHai/BeiJing
TEL: 021-63459295,
63455296, 63456297
FAX: 021-63456286
U.S.A. Branch
TEL: +1-408-737-9898
Toll Free: 800-500-4138
FAX: +1-408-737-9896
U.S.A. East Coast
TEL: +1-781-937-9888
Toll Free: 800-886-2243
FAX: +1-781-937-0170
Germany
Korea
France
North America
Italy
Israel
Finland
India
South Africa
TEL: +1-603-886-3900 TEL: +49-221-954790 TEL: +39-051-452042 TEL: +82-2-32823999 TEL: +972-3-9203456 TEL: +33-1-69061790 TEL: +358-2-6203753 TEL: +91-22-27890702 TEL: +27-11-462-1320
Toll Free: 800-833-8999 FAX: +49-221-9547988 FAX: +39-051-455046 FAX: +82-2-32823992 FAX: +972-9203535 FAX: +33-1-69433732 FAX: +358-2-6203770 FAX: +91-22-27890702 FAX: +27-11-704-3421
FAX: +1-603-886-4545
Brasil
TEL: +55-51-21293003
Toll Free: 800-704-4788
FAX: +55-51-21293017