BOSER MPE-8071

MPE-8071
70W AC-DC Open Frame Power Supply
Input Range: 85~270VDC
11.56
TB2
7.62
6.48
1
TRANSFORMER
Industrial Power Supply
12.7
0.5
TB3
0.25
3.86 MAX.
0.5
AC-DC
Features
Safety Standards
*Safety: UL 1950 / CSA 22.2 No.234 / VDE EN60950
*Input Voltage: 85~270VAC
*EMI: FCC class B / EN55022B
*Input Current: 2A at 115VAC or 1A at 230VAC max.
*Inrush Current: Does not exceed 30A at 115VAC input or
60A at 230VAC input, at cold start 25oC, and excluding EMI
PIN
Output
suppression capactiors
1~3
+5V
*Load Range: All outputs are at min. load conditions, while
4~6
GND
+5V output is between 5~5.1V and all other outputs are within
7
+12V
the specified voltage accuracy range
8
-12V
*Ripple and Noise: Peak to peak ripple and noise for all
outputs is < 1% of output voltage at rated load
*Line Regulation: < +/-2% for each output measured at rated
Output Min. Rated Max.
Voltage
Voltage Load Load
Load
Accuracy
load and +/-10% input voltage range
+5V
0A
10A
12A
5~5.1V
*Load Regulation: < +/-3% for +5V, +/-4% for +12V, and
+12V
0A
1.5A
2.5A 11.2~11.6V
+/-5% for -12V with +/-40% change on the measured output
-12V
0A
0.3A
0.3A -10.8~-12V
load, +/-40% from 60% rated load, while keeping other
outputs at 60% rated load
*Hold Up Time: > 16ms at 115VAC input and rated load,
measured from the end of the last charging pulse to when the
main output drops down to 95% output voltage
*Efficiency: > 70% at nominal line and rated load
*Altitude: 10,000 feet
*Protection: Latch-off mode against short circuit or over load
conditions AC input ON/OFF cycle to restart power supply
*Temperature: 0~+50oC (operating); -40~+85oC (storage)
*Connectors:
AC Input: Molex 5277-02A or equivalent device
DC Output: Molex 5273-08A or equivalent device
For Fan Use Only: Molex 5045-02A or equivalent device
*Dimensions: 12.7 x 7.62 x 3.85 cm at tolerance +/-0.4mm