INTEL TB28F004SC-100

E
PRELIMINARY
BYTE-WIDE
SmartVoltage FlashFile™ MEMORY FAMILY
4, 8, AND 16 MBIT
28F004SC, 28F008SC, 28F016SC
Includes Commercial and Extended Temperature Specifications
n
n
n
n
n
SmartVoltage Technology
 2.7 V (Read-Only), 3.3 V or 5 V V CC
and 3.3 V, 5 V, or 12 V V PP
High-Performance
 4, 8 Mbit 85 ns Read Access Time
 16 Mbit 95 ns Read Access Time
Enhanced Data Protection Features
 Absolute Protection with V PP = GND
 Flexible Block Locking
 Block Write Lockout during Power
Transitions
Enhanced Automated Suspend Options
 Program Suspend to Read
 Block Erase Suspend to Program
 Block Erase Suspend to Read
Industry-Standard Packaging
 40-Lead TSOP, 44-Lead PSOP
and 40 Bump µBGA* CSP
n
n
n
n
n
n
High-Density 64-Kbyte Symmetrical
Erase Block Architecture
 4 Mbit: Eight Blocks
 8 Mbit: Sixteen Blocks
 16 Mbit: Thirty-Two Blocks
Extended Cycling Capability
 100,000 Block Erase Cycles
Low Power Management
 Deep Power-Down Mode
 Automatic Power Savings Mode
Decreases ICC in Static Mode
Automated Program and Block Erase
 Command User Interface
 Status Register
SRAM-Compatible Write Interface
ETOX™ V Nonvolatile Flash
Technology
Intel’s byte-wide SmartVoltage FlashFile™ memory family renders a variety of density offerings in the same
package. The 4-, 8-, and 16-Mbit byte-wide FlashFile memories provide high-density, low-cost, nonvolatile,
read/write storage solutions for a wide range of applications. Their symmetrically-blocked architecture, flexible
voltage, and extended cycling provide highly flexible components suitable for resident flash arrays, SIMMs,
and memory cards. Enhanced suspend capabilities provide an ideal solution for code or data storage
applications. For secure code storage applications, such as networking, where code is either directly
executed out of flash or downloaded to DRAM, the 4-, 8-, and 16-Mbit FlashFile memories offer three levels
of protection: absolute protection with VPP at GND, selective hardware block locking, or flexible software
block locking. These alternatives give designers ultimate control of their code security needs.
This family of products is manufactured on Intel’s 0.4 µm ETOX™ V process technology. They come in
industry-standard packages: the 40-lead TSOP, ideal for board-constrained applications, and the rugged
44-lead PSOP. Based on the 28F008SA architecture, the byte-wide SmartVoltage FlashFile memory family
enables quick and easy upgrades for designs that demand state-of-the-art technology.
December 1997
Order Number: 290600-003
Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or
otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of
Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to
sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or
infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life
saving, or life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice.
The 28F004SC, 28F008SC, 28F016SC may contain design defects or errors known as errata. Current characterized errata are
available on request.
*Third-party brands and names are the property of their respective owners.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an ordering number and are referenced in this document, or other Intel literature, may be
obtained from:
Intel Corporation
P.O. Box 5937
Denver, CO 80217-9808
or call 1-800-548-4725
or visit Intel’s Website at http://www.intel.com
COPYRIGHT © INTEL CORPORATION 1996, 1997
CG-041493
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
CONTENTS
PAGE
1.0 INTRODUCTION .............................................5
1.1 New Features...............................................5
1.2 Product Overview.........................................5
1.3 Pinout and Pin Description ...........................6
2.0 PRINCIPLES OF OPERATION .....................12
2.1 Data Protection ..........................................13
3.0 BUS OPERATION .........................................13
3.1 Read ..........................................................13
3.2 Output Disable ...........................................13
3.3 Standby......................................................13
3.4 Deep Power-Down .....................................13
3.5 Read Identifier Codes Operation ................14
3.6 Write ..........................................................14
4.0 COMMAND DEFINITIONS ............................14
4.1 Read Array Command................................17
4.2 Read Identifier Codes Command ...............17
4.3 Read Status Register Command................17
4.4 Clear Status Register Command................17
4.5 Block Erase Command ..............................17
4.6 Program Command....................................18
4.7 Block Erase Suspend Command................18
4.8 Program Suspend Command .....................19
4.9 Set Block and Master Lock-Bit Commands 19
4.10 Clear Block Lock-Bits Command..............20
PAGE
6.0 ELECTRICAL SPECIFICATIONS..................30
6.1 Absolute Maximum Ratings ........................30
6.2 Commercial Temperature Operating
Conditions .................................................30
6.3 Capacitance ...............................................30
6.4 DC Characteristics—Commercial
Temperature..............................................31
6.5 AC Characteristics—Read-Only
Operations—Commercial Temperature .....35
6.6 AC Characteristics—Write Operations—
Commercial Temperature..........................37
6.7 Block Erase, Program, and Lock-Bit
Configuration Performance—Commercial
Temperature..............................................39
6.8 Extended Temperature Operating
Conditions .................................................40
6.9 DC Characteristics—Extended
Temperature..............................................40
6.10 AC Characteristics—Read-Only Operations
— Extended Temperature .........................40
7.0 ORDERING INFORMATION..........................41
8.0 ADDITIONAL INFORMATION .......................42
5.0 DESIGN CONSIDERATIONS ........................28
5.1 Three-Line Output Control..........................28
5.2 RY/BY# Hardware Detection ......................28
5.3 Power Supply Decoupling ..........................28
5.4 VPP Trace on Printed Circuit Boards...........28
5.5 VCC, VPP, RP# Transitions .........................28
5.6 Power-Up/Down Protection ........................28
5.7 VPP Program and Erase Voltages on Sub0.4µ SC Memory Family............................29
PRELIMINARY
3
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
E
REVISION HISTORY
Number
4
Description
-001
Original version
-002
Table 3 revised to reflect change in abbreviations from “W” for write to “P” for program.
Ordering information graphic (Appendix A) corrected: from PB = Ext. Temp. 44-Lead
PSOP to TB = Ext. Temp. 44-Lead PSOP.
Corrected nomenclature table (Appendix A) to reflect actual Operating Temperature/
Package information
Updated Ordering Information and table
Correction to table, Section 6.2.3. Under ILO Test Conditions, previously read V IN = VCC
or GND, corrected to VOUT = VCC or GND
Section 6.2.7, modified Program and Block Erase Suspend Latency Times
-003
Added µBGA* CSP pinout and corrected error in PSOP pinout.
Added Design Consideration for VPP Program and Erase Voltages on future sub-0.4µ
devices.
PRELIMINARY
E
1.0
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
INTRODUCTION
This datasheet contains 4-, 8-, and 16-Mbit
SmartVoltage FlashFile memory specifications.
Section 1.0 provides a flash memory overview.
Sections 2.0, through 5.0 describe the memory
organization and functionality. Section 6.0 covers
electrical specifications for commercial and
extended temperature product offerings. Section
7.0 contains ordering information. Finally, the bytewide SmartVoltage FlashFile memory family
documentation also includes application notes and
design tools which are referenced in Section 8.0.
1.1
New Features
The byte-wide SmartVoltage FlashFile memory
family maintains backwards-compatibility with
Intel’s
28F008SA
and
28F008SA-L.
Key
enhancements include:
•
SmartVoltage Technology
•
Enhanced Suspend Capabilities
•
In-System Block Locking
They share a compatible status register, software
commands, and pinouts. These similarities enable
a clean upgrade from the 28F008SA and
28F008SA-L to byte-wide SmartVoltage FlashFile
products. When upgrading, it is important to note
the following differences:
•
•
•
Because of new feature and density options,
the devices have different device identifier
codes. This allows for software optimization.
VPPLK has been lowered from 6.5 V to 1.5 V to
support low VPP voltages during block erase,
program, and lock-bit configuration operations.
Designs that switch VPP off during read
operations should transition VPP to GND.
To take advantage of SmartVoltage technology, allow VPP connection to 3.3 V or 5 V.
For more details see application note AP-625,
28F008SC Compatibility with 28F008SA (order
number 292180).
PRELIMINARY
1.2
Product Overview
The byte-wide SmartVoltage FlashFile memory
family provides density upgrades with pinout
compatibility for the 4-, 8-, and 16-Mbit densities.
The 28F004SC, 28F008SC, and 28F016SC are
high-performance
memories
arranged
as
512 Kbyte, 1 Mbyte, and 2 Mbyte of 8 bits. This
data is grouped in eight, sixteen, and thirty-two
64-Kbyte blocks which are individually erasable,
lockable, and unlockable in-system. Figure 4
illustrates the memory organization.
SmartVoltage technology enables fast factory
programming and low-power designs. These
components support read operations at 2.7 V (readonly), 3.3 V, and 5 V VCC and block erase and
program operations at 3.3 V, 5 V, and 12 V VPP.
The 12 V VPP option renders the fastest program
and erase performance which will increase your
factory throughput. With the 3.3 V and 5 V VPP
option, VCC and VPP can be tied together for a
simple and voltage flexible design. This voltage
flexibility is key for removable media that need to
operate in a 3 V to 5 V system. In addition, the
dedicated VPP pin gives complete data protection
when VPP ≤ VPPLK.
Table 1. SmartVoltage Flash
VCC and VPP Voltage Combinations
VCC Voltage
VPP Voltage
2.7 V(1)

3.3 V
3.3 V, 5 V, 12 V
5V
5 V, 12 V
NOTE:
1. Block erase, program, and lock-bit configuration
operation with VCC, 3.0 V are not supported.
Internal VCC and VPP detection circuitry
automatically configures the device for optimum
performance.
A Command User Interface (CUI) serves as the
interface between the system processor and
internal operation of the device. A valid command
sequence written to the CUI initiates device
automation. An internal Write State Machine (WSM)
automatically executes the algorithms and timings
necessary for block erase, program, and lock-bit
configuration operations.
5
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
A block erase operation erases one of the device’s
64-Kbyte blocks typically within 1 second
(5 V VCC, 12 V VPP), independent of other blocks.
Each block can be independently erased 100,000
times (1.6 million block erases per device). A block
erase suspend operation allows system software to
suspend block erase to read data from or write data
to any other block.
Data is programmed in byte increments typically
within 6 µs (5 V VCC, 12 V VPP). A program
suspend operation permits system software to read
data or execute code from any other flash memory
array location.
To protect programmed data, each block can be
locked. This block locking mechanism uses a
combination of bits, block lock-bits and a master
lock-bit, to lock and unlock individual blocks. The
block lock-bits gate block erase and program
operations, while the master lock-bit gates block
lock-bit configuration operations. Lock-bit configuration operations (Set Block Lock-Bit, Set Master
Lock-Bit, and Clear Block Lock-Bits commands) set
and clear lock-bits.
the WSM is performing a block erase, program, or
lock-bit configuration operation. RY/BY#-high
indicates that the WSM is ready for a new
command, block erase is suspended (and program
is inactive), program is suspended, or the device is
in deep power-down mode.
The Automatic Power Savings (APS) feature
substantially reduces active current when the
device is in static mode (addresses not switching).
In APS mode, the typical ICCR current is 1 mA at
5 V VCC.
When CE# and RP# pins are at VCC, the
component enters a CMOS standby mode. Driving
RP# to GND enables a deep power-down mode
which significantly reduces power consumption,
provides write protection, resets the device, and
clears the status register. A reset time (tPHQV) is
required from RP# switching high until outputs are
valid. Likewise, the device has a wake time (tPHEL)
from RP#-high until writes to the CUI are
recognized.
1.3
The status register and RY/BY# output indicate
whether or not the device is busy executing or
ready for a new command. Polling the status
register, system software retrieves WSM feedback.
The RY/BY# output gives an additional indicator of
WSM activity by providing a hardware status signal.
Like the status register, RY/BY#-low indicates that
6
E
Pinout and Pin Description
The family of devices is available in 40-lead TSOP
(Thin Small Outline Package, 1.2 mm thick) and
44-lead PSOP (Plastic Small Outline Package) and
40-bump µBGA* CSP (28F008SC and 28F016SC
only). Pinouts are shown in Figures 2, 3 and 4.
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
DQ 0 - DQ 7
Input
Buffer
Output
Buffer
Identifier
Register
I/O Logic
VCC
CE#
Status
Register
WE#
Command
Register
OE#
RP#
Data
Comparator
4-Mbit: A0 - A18 ,
8-Mbit: A 0 - A19 ,
16-Mbit: A0 - A 20
Input
Buffer
Y
Decoder
Address
Latch
X
Decoder
Y Gating
Write State
Machine
4-Mbit: Eight
8-Mbit: Sixteen
16-Mbit: Thirty-Two
64-Kbyte Blocks
RY/BY#
Program/Erase
Voltage Switch
VPP
VCC
GND
Address
Counter
Figure 1. Block Diagram
Table 2. Pin Descriptions
Sym
A0–A20
Type
INPUT
Name and Function
ADDRESS INPUTS: Inputs for addresses during read and write operations.
Addresses are internally latched during a write cycle.
4 Mbit → A0–A18
8 Mbit → A0–A19
16 Mbit → A0–A20
DQ0–DQ7
INPUT/ DATA INPUT/OUTPUTS: Inputs data and commands during CUI write cycles;
OUTPUT outputs data during memory array, status register, and identifier code read cycles.
Data pins float to high-impedance when the chip is deselected or outputs are
disabled. Data is internally latched during a write cycle.
CE#
INPUT
CHIP ENABLE: Activates the device’s control logic, input buffers, decoders, and
sense amplifiers. CE#-high deselects the device and reduces power consumption to
standby levels.
RP#
INPUT
RESET/DEEP POWER-DOWN: When driven low, RP# inhibits write operations
which provides data protection during power transitions, puts the device in deep
power-down mode, and resets internal automation. RP#-high enables normal
operation. Exit from deep power-down sets the device to read array mode.
RP# at VHH enables setting of the master lock-bit and enables configuration of block
lock-bits when the master lock-bit is set. RP# = V HH overrides block lock-bits,
thereby enabling block erase and program operations to locked memory blocks.
Block erase, program, or lock-bit configuration with V IH < RP# < VHH produce
spurious results and should not be attempted.
OE#
INPUT
OUTPUT ENABLE: Gates the device’s outputs during a read cycle.
PRELIMINARY
7
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Table 3. Pin Descriptions (Continued)
Sym
WE#
Type
Name and Function
INPUT
WRITE ENABLE: Controls writes to the CUI and array blocks. Addresses and data
are latched on the rising edge of the WE# pulse.
RY/BY#
OUTPUT READY/BUSY#: Indicates the status of the internal WSM. When low, the WSM is
performing an internal operation (block erase, program, or lock-bit configuration).
RY/BY#-high indicates that the WSM is ready for new commands, block erase or
program is suspended, or the device is in deep power-down mode. RY/BY# is
always active.
VPP
SUPPLY BLOCK ERASE, PROGRAM, LOCK-BIT CONFIGURATION POWER SUPPLY:
For erasing array blocks, programming data, or configuring lock-bits.
SmartVoltage Flash → 3.3 V, 5 V, and 12 V V PP
With VPP ≤ VPPLK, memory contents cannot be altered. Block erase, program, and
lock-bit configuration with an invalid VPP (see DC Characteristics) produce spurious
results and should not be attempted.
VCC
SUPPLY DEVICE POWER SUPPLY: Internal detection automatically configures the device
for optimized read performance. Do not float any power pins.
SmartVoltage Flash → 2.7 V (Read-Only), 3.3 V, and 5 V V CC
With VCC ≤ VLKO, all write attempts to the flash memory are inhibited. Device
operations at invalid VCC voltages (see DC Characteristics) produce spurious
results and should not be attempted. Block erase, program, and lock-bit
configuration operations with VCC < 3.0 V are not supported.
GND
NC
8
SUPPLY GROUND: Do not float any ground pins.
NO CONNECT: Lead is not internally connected; it may be driven or floated.
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
28F016SC
28F008SC
28F004SC
A19
A18
A17
A16
A15
A14
A13
A12
CE#
VCC
VPP
RP#
A11
A10
A9
A8
A7
A6
A5
A4
A19
A18
A17
A16
A15
A14
A13
A12
CE#
VCC
VPP
RP#
A11
A10
A9
A8
A7
A6
A5
A4
NC
A18
A17
A16
A15
A14
A13
A12
CE#
VCC
VPP
RP#
A11
A10
A9
A8
A7
A6
A5
A4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
40-LEAD TSOP
STANDARD PINOUT
10 mm x 20 mm
TOP VIEW
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
NC
NC
WE#
OE#
RY/BY#
NC
NC
WE#
OE#
RY/BY#
A 20
NC
WE#
OE#
RY/BY#
DQ7
DQ6
DQ5
DQ7
DQ6
DQ5
DQ7
DQ6
DQ5
DQ 4
VCC
GND
GND
DQ 4
VCC
GND
GND
DQ 4
VCC
GND
GND
DQ3
DQ2
DQ1
DQ0
DQ3
DQ2
DQ1
DQ0
DQ3
DQ2
DQ1
DQ0
A0
A1
A2
A3
A0
A1
A2
A3
A0
A1
A2
A3
Figure 2. TSOP 40-Lead Pinout
PRELIMINARY
9
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
E
Figure 3. PSOP 44-Lead Pinout
10
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
8
7
6
5
4
3
2
1
A
A7
A9
RP#
VPP
VCC
A12
A15
A17
A6
A10
A11
CE#
A13
A14
A16
A18
A4
A5
A3
A8
NC
A19
RY/BY#
A20
A2
A0
D1
D3
GND
D4
D6
WE#
A1
D0
D2
GND
VCC
D5
D7
OE#
B
C
D
E
Bottom View - Bump Side Up
Pin #1
Indicator
1
2
3
4
5
6
7
8
A17
A15
A12
VCC
VPP
RP#
A9
A7
A18
A16
A14
A13
CE#
A11
A10
A6
NC
RY/BY#
A19
NC
A8
A3
A5
A4
A
B
C
D
WE#
D6
D4
GND
D3
D1
A0
A2
OE#
D7
D5
VCC
GND
D2
D0
A1
E
Top View - Bump Side Down
This is the view of the package as surface mounted on the board.
Note that the signals are mirror images of bottom view.
NOTES:
1. Figures are not drawn to scale.
2. Address A20 is not included in the 28F008SC.
3. More information on µBGA* packages is available by contacting your Intel/Distribution sales office.
Figure 4. µBGA* CSP 40-Ball Pinout (28F008SC and 28F016SC)
PRELIMINARY
11
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
2.0
PRINCIPLES OF OPERATION
The byte-wide SmartVoltage FlashFile memories
include an on-chip WSM to manage block erase,
program, and lock-bit configuration functions. It
allows for: 100% TTL-level control inputs, fixed
power supplies during block erasure, program, and
lock-bit configuration, and minimal processor
overhead with RAM-like interface timings.
After initial device power-up or return from deep
power-down mode (see Bus Operations), the
device defaults to read array mode. Manipulation of
external memory control pins allow array read,
standby, and output disable operations.
Status register and identifier codes can be
accessed through the CUI independent of the VPP
voltage. High voltage on VPP enables successful
block erasure, program, and lock-bit configuration.
All functions associated with altering memory
contents—block
erase,
program,
lock-bit
configuration, status, and identifier codes—are
accessed via the CUI and verified through the
status register.
1FFFFF
1F0000
1EFFFF
1E0000
1DFFFF
1D0000
1CFFFF
1C0000
1BFFFF
1B0000
1AFFFF
1A0000
19FFFF
190000
18FFFF
180000
17FFFF
170000
16FFFF
160000
15FFFF
150000
14FFFF
140000
13FFFF
130000
12FFFF
120000
11FFFF
110000
10FFFF
100000
0FFFFF
Commands are written using standard microprocessor write timings. The CUI contents serve as
input to the WSM that controls block erase,
program, and lock-bit configuration operations. The
internal algorithms are regulated by the WSM,
including pulse repetition, internal verification, and
margining of data. Addresses and data are
internally latched during write cycles. Writing the
appropriate command outputs array data, accesses
the identifier codes, or outputs status register data.
Interface software that initiates and polls progress
of block erase, program, and lock-bit configuration
can be stored in any block. This code is copied to
and executed from system RAM during flash
memory updates. After successful completion,
reads are again possible via the Read Array
command. Block erase suspend allows system
software to suspend a block erase to read or write
data from any other block. Program suspend allows
system software to suspend a program to read data
from any other flash memory array location.
0F0000
0EFFFF
0E0000
0DFFFF
0D0000
0CFFFF
0C0000
0BFFFF
0B0000
0AFFFF
0A0000
09FFFF
090000
08FFFF
080000
07FFFF
070000
06FFFF
060000
05FFFF
050000
04FFFF
040000
03FFFF
030000
02FFFF
020000
01FFFF
010000
00FFFF
000000
64-Kbyte Block
31
64-Kbyte Block
30
64-Kbyte Block
29
64-Kbyte Block
28
64-Kbyte Block
27
64-Kbyte Block
26
64-Kbyte Block
25
64-Kbyte Block
24
64-Kbyte Block
23
64-Kbyte Block
22
64-Kbyte Block
21
64-Kbyte Block
20
64-Kbyte Block
19
64-Kbyte Block
18
64-Kbyte Block
17
64-Kbyte Block
16
64-Kbyte Block
15
64-Kbyte Block
14
64-Kbyte Block
13
64-Kbyte Block
12
64-Kbyte Block
11
64-Kbyte Block
10
64-Kbyte Block
9
64-Kbyte Block
8
64-Kbyte Block
7
64-Kbyte Block
6
64-Kbyte Block
5
64-Kbyte Block
4
64-Kbyte Block
3
64-Kbyte Block
2
64-Kbyte Block
1
64-Kbyte Block
0
16-Mbit
8-Mbit
4-Mbit
Figure 5. Memory Map
12
PRELIMINARY
E
2.1
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Data Protection
Depending on the application, the system designer
may choose to make the VPP power supply
switchable (available only when memory block
erases, programs, or lock-bit configurations are
required) or hardwired to VPPH1/2/3. The device
accommodates either design practice and
encourages optimization of the processor-memory
interface.
When VPP ≤ VPPLK, memory contents cannot be
altered. When high voltage is applied to VPP, the
two-step block erase, program, or lock-bit
configuration command sequences provides protection from unwanted operations. All write
functions are disabled when VCC voltage is below
the write lockout voltage VLKO or when RP# is at
VIL. The device’s block locking capability provides
additional protection from inadvertent code or data
alteration by gating erase and program operations.
3.2
Output Disable
With OE# at a logic-high level (VIH), the device
outputs are disabled. Output pins DQ0–DQ7 are
placed in a high-impedance state.
3.3
Standby
CE# at a logic-high level (VIH) places the device in
standby mode which substantially reduces device
power consumption. DQ0–DQ7 outputs are placed
in a high-impedance state independent of OE#. If
deselected during block erase, program, or
lock-bit configuration, the device continues
functioning and consuming active power until the
operation completes.
3.4
Deep Power-Down
RP# at VIL initiates the deep power-down mode.
3.0
BUS OPERATION
The local CPU reads and writes flash memory
in-system. All bus cycles to or from the flash
memory conform to standard microprocessor bus
cycles.
3.1
Read
Block information, identifier codes, or status register
can be read independent of the VPP voltage. RP#
can be at either VIH or VHH.
The first task is to write the appropriate read-mode
command (Read Array, Read Identifier Codes, or
Read Status Register) to the CUI. Upon initial
device power-up or after exit from deep powerdown mode, the device automatically resets to read
array mode. Four control pins dictate the data flow
in and out of the component: CE#, OE#, WE#, and
RP#. CE# and OE# must be driven active to obtain
data at the outputs. CE# is the device selection
control, and when active enables the selected
memory device. OE# is the data output (DQ0–DQ7)
control and when active drives the selected
memory data onto the I/O bus. WE# must be at VIH
and RP# must be at VIH or VHH. Figure 18
illustrates a read cycle.
PRELIMINARY
In read mode, RP#-low deselects the memory,
places output drivers in a high-impedance state,
and turns off all internal circuits. RP# must be held
low for time tPLPH. Time tPHQV is required after
return from power-down until initial memory access
outputs are valid. After this wake-up interval,
normal operation is restored. The CUI resets to
read array mode, and the status register is set to
80H.
During block erase, program, or lock-bit
configuration, RP#-low will abort the operation.
RY/BY# remains low until the reset operation is
complete. Memory contents being altered are no
longer valid; the data may be partially erased or
written. Time tPHWL is required after RP# goes to
logic-high (VIH) before another command can be
written.
As with any automated device, it is important to
assert RP# during system reset. When the system
comes out of reset, it expects to read from the flash
memory. Automated flash memories provide status
information when accessed during block erase,
program, or lock-bit configuration modes. If a CPU
reset occurs with no flash memory reset, proper
CPU initialization may not occur because the flash
memory may be providing status information
instead of array data. Intel’s flash memories allow
proper CPU initialization following a system reset
through the use of the RP# input. In this application,
RP# is controlled by the same RESET# signal that
resets the system CPU.
13
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
3.5
1FFFFF
Block 31
Block 31 Lock Configuration
1F0000
Reserved for
Future Implementation
(Blocks 16 through 30)
0FFFFF
Block 15
Reserved for
Future Implementation
0F0002
0F0000
3.6
Block 15 Lock Configuration
Reserved for
Future Implementation
(Blocks 8 through 14)
07FFFF
16-Mbit
Block 7
Reserved for
Future Implementation
070002
Block 7 Lock Configuration
070000
Reserved for
Future Implementation
8-Mbit
Block 1
Reserved for
Future Implementation
010002
010000
00FFFF
000003
000002
000001
000000
Write
The CUI does not occupy an addressable memory
location. It is written when WE# and CE# are active
and OE# = VIH. The address and data needed to
execute a command are latched on the rising edge
of WE# or CE# (whichever goes high first).
Standard microprocessor write timings are used.
Figure 18 illustrates a write operation.
4.0
(Blocks 2 through 14)
01FFFF
Read Identifier Codes
Operation
The read identifier codes operation outputs the
manufacturer code, device code, block lock
configuration codes for each block, and master lock
configuration code (see Figure 6). Using the
manufacturer and device codes, the system
software can automatically match the device with its
proper algorithms. The block lock and master lock
configuration codes identify locked and unlocked
blocks and master lock-bit setting.
Reserved for
Future Implementation
1F0002
E
COMMAND DEFINITIONS
When the VPP voltage ≤ VPPLK, read operations
from the status register, identifier codes, or blocks
are enabled. Placing VPPH1/2/3 on VPP enables
successful block erase, program, and lock-bit
configuration operations.
4-Mbit
Block 1 Lock Configuration
Reserved for
Future Implementation
Device operations are selected by writing specific
commands into the CUI. Table 4 defines these
commands.
Block 0
Reserved For
Future Implementation
Master Lock Configuration
Block 0 Lock Configuration
Device Code
Manufacturer Code
Figure 6. Device Identifier Code Memory Map
14
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Table 3. Bus Operations
Mode
Notes
RP#
CE#
OE#
WE#
Address
VPP
DQ0–7
RY/BY#
1,2,3
VIH or
VHH
VIL
VIL
VIH
X
X
DOUT
X
Output Disable
3
VIH or
VHH
VIL
VIH
VIH
X
X
High Z
X
Standby
3
VIH or
VHH
VIH
X
X
X
X
High Z
X
Deep Power-Down
4
VIL
X
X
X
X
X
High Z
VOH
VIH or
VHH
VIL
VIL
VIH
See
Figure 5
X
Note 5
VOH
VIH or
VHH
VIL
VIH
VIL
X
X
DIN
X
Read
Read Identifier Codes
Write
3,6,7
NOTES:
1. Refer to DC Characteristics. When VPP ≤ VPPLK, memory contents can be read, but not altered.
2. X can be VIL or VIH for control and address input pins and VPPLK or VPPH1/2/3 for VPP. See DC Characteristics for VPPLK and
VPPH1/2/3 voltages.
3. RY/BY# is VOL when the WSM is executing internal block erase, program, or lock-bit configuration algorithms. It is VOH
when the WSM is not busy, in block erase suspend mode (with program inactive), program suspend mode, or deep powerdown mode.
4. RP# at GND ± 0.2 V ensures the lowest deep power-down current.
5. See Section 4.2 for read identifier code data.
6. Command writes involving block erase, write, or lock-bit configuration are reliably executed when VPP = VPPH1/2/3 and
VCC = VCC2/3 (see Section 6.2 for operating conditions).
7. Refer to Table 4 for valid DIN during a write operation.
PRELIMINARY
15
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Table 4. Command Definitions(9)
Bus Cycles
Command
Read Array/Reset
Req’d.
First Bus Cycle
Notes
1
Second Bus Cycle
Oper(1) Addr(2) Data(3) Oper(1) Addr(2) Data(3)
Write
X
FFH
Write
X
90H
Read
IA
ID
2
Write
X
70H
Read
X
SRD
1
Write
X
50H
5
Write
BA
20H
Write
BA
D0H
5,6
Write
PA
40H
or
10H
Write
PA
PD
5
Write
X
B0H
1
5
Write
X
D0H
Set Block Lock-Bit
2
7
Write
BA
60H
Write
BA
01H
Set Master Lock-Bit
2
7
Write
X
60H
Write
X
F1H
Clear Block Lock-Bits
2
8
Write
X
60H
Write
X
D0H
Read Identifier Codes
≥2
Read Status Register
Clear Status Register
Block Erase
2
Program
2
Block Erase and Program
Suspend
1
Block Erase and Program
Resume
4
NOTES:
1. Bus operations are defined in Table 3.
2. X = Any valid address within the device.
IA = Identifier Code Address: see Figure 6.
BA = Address within the block being erased or locked.
PA = Address of memory location to be programmed.
3. SRD = Data read from status register. See Table 7 for a description of the status register bits.
PD = Data to be programmed at location PA. Data is latched on the rising edge of WE# or CE# (whichever goes high first).
ID = Data read from identifier codes.
4. Following the Read Identifier Codes command, read operations access manufacturer, device, block lock, and master lock
codes. See Section 4.2 for read identifier code data.
5. If the block is locked, RP# must be at VHH to enable block erase or program operations. Attempts to issue a block erase or
program to a locked block while RP# is VIH will fail.
6. Either 40H or 10H are recognized by the WSM as the program setup.
7. If the master lock-bit is set, RP# must be at VHH to set a block lock-bit. RP# must be at VHH to set the master lock-bit. If the
master lock-bit is not set, a block lock-bit can be set while RP# is VIH.
8. If the master lock-bit is set, RP# must be at VHH to clear block lock-bits. The clear block lock-bits operation simultaneously
clears all block lock-bits. If the master lock-bit is not set, the Clear Block Lock-Bits command can be done while RP# is VIH.
9. Commands other than those shown above are reserved by Intel for future device implementations and should not be used.
16
PRELIMINARY
E
4.1
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Read Array Command
4.3
Upon initial device power-up and after exit from
deep power-down mode, the device defaults to read
array mode. This operation is also initiated by
writing the Read Array command. The device
remains enabled for reads until another command
is written. Once the internal WSM has started a
block erase, program or lock-bit configuration, the
device will not recognize the Read Array command
until the WSM completes its operation unless the
WSM is suspended via an Erase Suspend or
Program Suspend command. The Read Array
command functions independently of the VPP
voltage and RP# can be VIH or VHH.
4.2
Read Identifier Codes
Command
Table 5. Identifier Codes
Code
Manufacturer Code
Address
000000
4 Mbit
000001
Device Code
8 Mbit
000001
16 Mbit 000001
Block Lock Configuration
XX0002(1)
• Block Is Unlocked
• Block Is Locked
• Reserved for Future Use
Master Lock Configuration
000003
• Device Is Unlocked
• Device Is Locked
• Reserved for Future Use
Data
89
A7
A6
AA
DQ0 = 0
DQ0 = 1
DQ1–7
DQ0 = 0
DQ0 = 1
DQ1–7
NOTE:
1. X selects the specific block lock configuration code to
be read. See Figure 6 for the Device Identifier Code
Memory Map.
PRELIMINARY
The status register may be read to determine when
a block erase, program, or lock-bit configuration is
complete and whether the operation completed
successfully. It may be read at any time by writing
the Read Status Register command. After writing
this command, all subsequent read operations
output data from the status register until another
valid command is written. The status register
contents are latched on the falling edge of OE# or
CE#, whichever occurs first. OE# or CE# must
toggle to VIH to update the status register latch. The
Read Status Register command functions
independently of the VPP voltage. RP# can be VIH
or VHH.
4.4
The identifier code operation is initiated by writing
the Read Identifier Codes command. Following the
command write, read cycles from addresses shown
in Figure 5 retrieve the manufacturer, device, block
lock configuration and master lock configuration
codes (see Table 5 for identifier code values). To
terminate the operation, write another valid
command. Like the Read Array command, the
Read Identifier Codes command functions
independently of the VPP voltage and RP# can be
VIH or VHH. Following the Read Identifier Codes
command, the subsequent information can be read.
Read Status Register
Command
Clear Status Register
Command
Status register bits SR.5, SR.4, SR.3, and SR.1 are
set to “1”s by the WSM and can only be reset by
the Clear Status Register command. These bits
indicate various failure conditions (see Table 7). By
allowing system software to reset these bits,
several operations (such as cumulatively erasing or
locking multiple blocks or writing several bytes in
sequence) may be performed. The status register
may be polled to determine if an error occurred
during the sequence.
To clear the status register, the Clear Status
Register command (50H) is written. It functions
independently of the applied VPP voltage. RP# can
be VIH or VHH. This command is not functional
during block erase or program suspend modes.
4.5
Block Erase Command
Erase is executed one block at a time and initiated
by a two-cycle command. A block erase setup is
written first, followed by a block erase confirm. This
command sequence requires appropriate sequencing and an address within the block to be
erased (erase changes all block data to FFH).
Block preconditioning, erase, and verify are handled
internally by the WSM (invisible to the system).
After the two-cycle block erase sequence is written,
the device automatically outputs status register
data when read (see Figure 67). The CPU can
detect block erase completion by analyzing the
RY/BY# pin or status register bit SR.7.
17
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
When the block erase is complete, status register
bit SR.5 should be checked. If a block erase error is
detected, the status register should be cleared
before system software attempts corrective actions.
The CUI remains in read status register mode until
a new command is issued.
This two-step command sequence of set-up
followed by execution ensures that block contents
are not accidentally erased. An invalid Block Erase
command sequence will result in both status
register bits SR.4 and SR.5 being set to “1.” Also,
reliable block erasure can only occur when
VCC = VCC2/3 and VPP = VPPH1/2/3. In the absence of
this high voltage, block contents are protected
against erasure. If block erase is attempted while
VPP ≤ VPPLK, SR.3 and SR.5 will be set to “1.”
Successful block erase requires that the
corresponding block lock-bit be cleared or, if set,
that RP# = VHH. If block erase is attempted when
the corresponding block lock-bit is set and
RP# = VIH, the block erase will fail, and SR.1 and
SR.5 will be set to “1.” Block erase operations with
VIH < RP# < VHH produce spurious results and
should not be attempted.
4.6
Program Command
Program is executed by a two-cycle command
sequence. Program setup (standard 40H or
alternate 10H) is written, followed by a second write
that specifies the address and data (latched on the
rising edge of WE#). The WSM then takes over,
controlling the program and write verify algorithms
internally. After the program sequence is written,
the device automatically outputs status register
data when read (see Figure 8). The CPU can detect
the completion of the program event by analyzing
the RY/BY# pin or status register bit SR.7.
When program is complete, status register bit SR.4
should be checked. If program error is detected, the
status register should be cleared. The internal WSM
verify only detects errors for “1”s that do not
successfully write to “0”s. The CUI remains in read
status register mode until it receives another
command.
Reliable programs only occurs when VCC = VCC2/3
and VPP = VPPH1/2/3. In the absence of this high
voltage, memory contents are protected against
programs. If program is attempted while
VPP ≤ VPPLK, the operation will fail, and status
register bits SR.3 and SR.5 will be set to “1.”
18
E
Successful program also requires that the
corresponding block lock-bit be cleared or, if set,
that RP# = VHH. If program is attempted when the
corresponding block lock-bit is set and RP# = VIH,
program will fail, and SR.1 and SR.4 will be set to
“1.” Program operations with VIH < RP# < VHH
produce spurious results and should not be
attempted.
4.7
Block Erase Suspend
Command
The Block Erase Suspend command allows
block-erase interruption to read or write data in
another block of memory. Once the block erase
process starts, writing the Block Erase Suspend
command requests that the WSM suspend the
block erase sequence at a predetermined point in
the algorithm. The device outputs status register
data when read after the Block Erase Suspend
command is written. Polling status register bits
SR.7 and SR.6 can determine when the block erase
operation has been suspended (both will be set to
“1”). RY/BY# will also transition to VOH.
Specification tWHRH2 defines the block erase
suspend latency.
At this point, a Read Array command can be written
to read data from blocks other than that which is
suspended. A Program command sequence can
also be issued during erase suspend to program
data in other blocks. Using the Program Suspend
command (see Section 4.8), a program operation
can also be suspended. During a program operation
with block erase suspended, status register bit
SR.7 will return to “0” and the RY/BY# output will
transition to VOL. However, SR.6 will remain “1” to
indicate block erase suspend status.
The only other valid commands while block erase is
suspended are Read Status Register and Block
Erase Resume. After a Block Erase Resume
command is written to the flash memory, the WSM
will continue the block erase process. Status
register bits SR.6 and SR.7 will automatically clear
and RY/BY# will return to VOL. After the Erase
Resume command is written, the device
automatically outputs status register data when
read (see Figure 9). VPP must remain at VPPH1/2/3
(the same VPP level used for block erase) while
block erase is suspended. RP# must also remain at
VIH or VHH (the same RP# level used for block
erase). Block erase cannot resume until program
operations initiated during block erase suspend
have completed.
PRELIMINARY
E
4.8
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Program Suspend Command
The Program Suspend command allows program
interruption to read data in other flash memory
locations. Once the program process starts, writing
the Program Suspend command requests that the
WSM suspend the program sequence at a
predetermined point in the algorithm. The device
continues to output status register data when read
after the Program Suspend command is written.
Polling status register bits SR.7 and SR.2 can
determine when the program operation has been
suspended (both will be set to “1”). RY/BY# will also
transition to VOH. Specification tWHRH1 defines the
program suspend latency.
At this point, a Read Array command can be written
to read data from locations other than that which is
suspended. The only other valid commands while
program is suspended are Read Status Register
and Program Resume. After Program Resume
command is written to the flash memory, the WSM
will continue the program process. Status register
bits SR.2 and SR.7 will automatically clear and
RY/BY# will return to VOL. After the Program
Resume command is written, the device
automatically outputs status register data when
read (see Figure 10). VPP must remain at VPPH1/2/3
(the same VPP level used for program) while in
program suspend mode. RP# must also remain at
VIH or VHH (the same RP# level used for program).
4.9
Set Block and Master Lock-Bit
Commands
A flexible block locking and unlocking scheme is
enabled via a combination of block lock-bits and a
master lock-bit. The block lock-bits gate program
and erase operations while the master lock-bit
gates block-lock bit modification. With the master
lock-bit not set, individual block lock-bits can be set
using the Set Block Lock-Bit command. The Set
Master Lock-Bit command, in conjunction with
RP# = VHH, sets the master lock-bit. After the
PRELIMINARY
master lock-bit is set, subsequent setting of block
lock-bits requires both the Set Block Lock-Bit
command and VHH on the RP# pin. See Table 6 for
a summary of hardware and software write
protection options.
Set block lock-bit and master lock-bit are initiated
using two-cycle command sequence. The set block
or master lock-bit setup along with appropriate
block or device address is written followed by either
the set block lock-bit confirm (and an address within
the block to be locked) or the set master lock-bit
confirm (and any device address). The WSM then
controls the set lock-bit algorithm. After the
sequence is written, the device automatically
outputs status register data when read (see
Figure 11). The CPU can detect the completion of
the set lock-bit event by analyzing the RY/BY# pin
output or status register bit SR.7.
When the set lock-bit operation is complete, status
register bit SR.4 should be checked. If an error is
detected, the status register should be cleared. The
CUI will remain in read status register mode until a
new command is issued.
This two-step sequence of setup followed by
execution ensures that lock-bits are not accidentally
set. An invalid Set Block or Master Lock-Bit
command will result in status register bits SR.4 and
SR.5 being set to “1.” Also, reliable operations
occur only when VCC = VCC2/3 and VPP = VPPH1/2/3.
In the absence of this high voltage, lock-bit contents
are protected against alteration.
A successful set block lock-bit operation requires
that the master lock-bit be cleared or, if the master
lock-bit is set, that RP# = VHH. If it is attempted with
the master lock-bit set and RP# = VIH, the operation
will fail, and SR.1 and SR.4 will be set to “1.” A
successful set master lock-bit operation requires
that RP# = VHH. If it is attempted with RP# = VIH,
the operation will fail, and SR.1 and SR.4 will be set
to “1.” Set block and master lock-bit operations with
VIH < RP# < VHH produce spurious results and
should not be attempted.
19
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
4.10
Clear Block Lock-Bits
Command
All set block lock-bits are cleared in parallel via the
Clear Block Lock-Bits command. With the master
lock-bit not set, block lock-bits can be cleared using
only the Clear Block Lock-Bits command. If the
master lock-bit is set, clearing block lock-bits
requires both the Clear Block Lock-Bits command
and VHH on the RP# pin. See Table 6 for a
summary of hardware and software write protection
options.
Clear block lock-bits operation is initiated using a
two-cycle command sequence. A clear block
lock-bits setup is written first. Then, the device
automatically outputs status register data when
read (see Figure 12). The CPU can detect
completion of the clear block lock-bits event by
analyzing the RY/BY# pin output or status register
bit SR.7.
When the operation is complete, status register bit
SR.5 should be checked. If a clear block lock-bit
error is detected, the status register should be
cleared. The CUI will remain in read status register
mode until another command is issued.
This two-step sequence of set-up followed by
execution ensures that block lock-bits are not
accidentally cleared. An invalid Clear Block
Lock-Bits command sequence will result in status
register bits SR.4 and SR.5 being set to “1.” Also, a
reliable clear block lock-bits operation can only
occur when VCC = VCC2/3 and VPP = VPPH1/2/3. If a
clear block lock-bits operation is attempted while
VPP ≤ VPPLK, SR.3 and SR.5 will be set to “1.” In the
absence of this high voltage, the block lock-bits
content are protected against alteration. A successful clear block lock-bits operation requires that
the master lock-bit is not set or, if the master lockbit is set, that RP# = VHH. If it is attempted with the
master lock-bit set and RP# = VIH, SR.1 and SR.5
will be set to “1” and the operation will fail. A clear
block lock-bits operation with VIH < RP# < VHH
produce spurious results and should not be
attempted.
If a clear block lock-bits operation is aborted due to
VPP or VCC transitioning out of valid range or RP#
active transition, block lock-bit values are left in an
undetermined state. A repeat of clear block lockbits is required to initialize block lock-bit contents to
known values. Once the master lock-bit is set, it
cannot be cleared.
Table 6. Write Protection Alternatives
Operation
Master
Block
Lock-Bit Lock-Bit
Block Erase or
Program
X
RP#
Effect
0
VIH or VHH
1
VIH
Block Erase and Program Enabled
Block is Locked. Block Erase and Program Disabled
VHH
Block Lock-Bit Override. Block Erase and Program
Enabled
Set Block
0
X
VIH or VHH
Lock-Bit
1
X
VIH
Master Lock-Bit is Set. Set Block Lock-Bit Disabled
VHH
Master Lock-Bit Override. Set Block Lock-Bit
Enabled
Set Master
Set Block Lock-Bit Enabled
X
X
VIH
Set Master Lock-Bit Disabled
VHH
Set Master Lock-Bit Enabled
Clear Block
0
X
VIH or VHH
Lock-Bits
1
X
VIH
Master Lock-Bit is Set. Clear Block Lock-Bits
Disabled
VHH
Master Lock-Bit Override. Clear Block Lock-Bits
Enabled
Lock-Bit
20
Clear Block Lock-Bits Enabled
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Table 7. Status Register Definition
WSMS
ESS
ECLBS
PSLBS
VPPS
PSS
DPS
R
7
6
5
4
3
2
1
0
NOTES:
SR.7 = WRITE STATE MACHINE STATUS
1 = Ready
0 = Busy
Check RY/BY# or SR.7 to determine block erase,
program, or lock-bit configuration completion.
SR.6–0 are invalid while SR.7 = “0.”
SR.6 = ERASE SUSPEND STATUS
1 = Block Erase Suspended
0 = Block Erase in Progress/Completed
SR.5 = ERASE AND CLEAR LOCK-BITS
STATUS
1 = Error in Block Erasure or Clear Lock-Bits
0 = Successful Block Erase or Clear Lock-Bits
If both SR.5 and SR.4 are “1”s after a block erase or
lock-bit configuration attempt, an improper
command sequence was entered.
SR.4 = PROGRAM AND SET LOCK-BIT
STATUS
1 = Error in Program or Set Master/Block
Lock-Bit
0 = Successful Program or Set Master/Block
Lock-Bit
SR.3 = VPP STATUS
1 = VPP Low Detect, Operation Abort
0 = VPP OK
SR.3 does not provide a continuous indication of
VPP level. The WSM interrogates and indicates the
VPP level only after a block erase, program, or lockbit configuration operation. SR.3 is not guaranteed
to reports accurate feedback only when VPP ≠
VPPH1/2/3.
SR.2 = PROGRAM SUSPEND STATUS
1 = Program Suspended
0 = Program in Progress/Completed
SR.1 = DEVICE PROTECT STATUS
1 = Master Lock-Bit, Block Lock-Bit and/or
RP# Lock Detected, Operation Abort
0 = Unlock
SR.1 does not provide a continuous indication of
master and block lock-bit values. The WSM
interrogates the master lock-bit, block lock-bit, and
RP# only after a block erase, program, or lock-bit
configuration operation. It informs the system,
depending on the attempted operation, if the block
lock-bit is set, master lock-bit is set, and/or
RP# ≠ VHH.
SR.0 = RESERVED FOR FUTURE
ENHANCEMENTS
SR.0 is reserved for future use and should be
masked out when polling the status register.
PRELIMINARY
21
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Start
Write 20H,
Block Address
Bus
Operation
Command
Write
Erase Setup
Data = 20H
Addr = Within Block to Be Erased
Write
Erase
Confirm
Data = D0H
Addr = Within Block to Be Erased
Write D0H,
Block Address
Comments
Status Register Data
Read
Read Status
Register
Suspend Block
Erase Loop
No
0
SR.7 =
Suspend
Block Erase
Yes
1
Full Status
Check if Desired
Standby
Check SR.7
1 = WSM Ready
0 = WSM Busy
Repeat for subsequent block erasures.
Full status check can be done after each block erase, or after a
sequence of block erasures.
Write FFH after the last operation to place device in read array mode.
Block Erase
Complete
FULL STATUS CHECK PROCEDURE
Bus
Operation
Read Status Register
Data (See Above)
Standby
SR.3 =
1
VPP Range Error
Standby
0
SR.1 =
1
1
Command Sequence
Error
0
1
SR.5 =
Comments
Check SR.3
1 = VPP Error Detect
Check SR.1
1 = Device Protect Detect
RP# = V IH , Block Lock-Bit Is Set
Only required for systems
implementing lock-bit configuration
Device Protect Error
Standby
Check SR.4,5
Both 1 = Command Sequence Error
Standby
Check SR.5
1 = Block Erase Error
0
SR.4,5 =
Command
Block Erase
Error
SR.5, SR.4, SR.3 and SR.1 are only cleared by the Clear Status
Register command in cases where multiple blocks are erased
before full status is checked.
If error is detected, clear the Status Register before attempting
retry or other error recovery.
0
Block Erase
Successful
Figure 7. Automated Block Erase Flowchart
22
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Start
Bus
Operation
Write 40H,
Address
Command
Comments
Write
Setup
Program
Data = 40H
Addr = Location to Be Programmed
Write
Program
Data = Data to Be Programmed
Addr = Location to Be Programmed
Write Byte
Data and Address
Read
Status Register Data
Read
Status Register
Suspend
Program Loop
Standby
Check SR.7
1 = WSM Ready
0 = WSM Busy
No
0
Suspend
Program
SR.7 =
Yes
1
Full Status
Check if Desired
Repeat for subsequent byte writes.
SR full status check can be done after each program, or after a
sequence of program operations.
Write FFH after the last program operation to reset device to
read array mode.
Program Complete
FULL STATUS CHECK PROCEDURE
Bus
Operation
Read Status Register
Data (See Above)
Command
Standby
SR.3 =
1
VPP Range Error
0
SR.1 =
Standby
1
Device Protect Error
0
Standby
Comments
Check SR.3
1 = VPP Error Detect
Check SR.1
1 = Device Protect Detect
RP# = V IH , Block Lock-Bit Is Set
Only required for systems
implementing lock-bit configuration
Check SR.4
1 = Program Error
1
SR.4 =
0
Program Successful
Program Error
SR.4, SR.3 and SR.1 are only cleared by the Clear Status Register
command in cases where multiple locations are written before
full status is checked.
If error is detected, clear the Status Register before attempting
retry or other error recovery.
Figure 8. Automated Program Flowchart
PRELIMINARY
23
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Start
Write B0H
Bus
Operation
Command
Write
Erase
Suspend
Read
Standby
Check SR.7
1 = WSM Ready
0 = WSM Busy
Standby
Check SR.6
1 = Block Erase Suspended
0 = Block Erase Completed
0
1
Write
0
SR.6 =
Data = B0H
Addr = X
Status Register Data
Addr = X
Read
Status Register
SR.7 =
Comments
Erase
Resume
Data = D0H
Addr = X
Block Erase Completed
1
Read
Read Array
Data
Read or
Program
?
Program
No
Program
Loop
Done?
Yes
Write D0H
Write FFH
Block Erase Resumed
Read Array Data
Figure 9. Block Erase Suspend/Resume Flowchart
24
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Start
Bus
Operation
Write
Write B0H
Command
Program
Suspend
Read
Read
Status Register
0
SR.7 =
Comments
Data = B0H
Addr = X
Status Register Data
Addr = X
Standby
Check SR.7
1 = WSM Ready
0 = WSM Busy
Standby
Check SR.2
1 =Program Suspended
0 = Program Completed
1
Write
0
Read Array
Data = FFH
Addr = X
Program Completed
SR.2 =
Read
Read array locations other
than that being data written.
1
Write
Write FFH
Program
Resume
Data = D0H
Addr = X
Read Array Data
Done
Reading
No
Yes
Write D0H
Write FFH
Program Resumed
Read Array Data
Figure 10. Program Suspend/Resume Flowchart
PRELIMINARY
25
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Start
Bus
Operation
Write
Write 60H,
Block/Device Address
Write
Write 01H/F1H,
Block/Device Address
Command
Comments
Set
Block/Master
Lock-Bit Setup
Data = 60H
Addr = Block Address (Block),
Device Address (Master)
Set
Data = 01H (Block),
Block or Master
F1H (Master)
Lock-Bit Confirm Addr = Block Address (Block),
Device Address (Master)
Status Register Data
Read
Read Status
Register
Check SR.7
1 = WSM Ready
0 = WSM Busy
Standby
0
SR.7 =
Repeat for subsequent lock-bit set operations.
Full status check can be done after each lock-bit set operation or after
a sequence of lock-bit set operations.
Write FFH after the last lock-bit set operation to place device in
read array mode.
1
Full Status
Check if Desired
Set Lock-Bit Complete
FULL STATUS CHECK PROCEDURE
Bus
Operation
Read Status Register
Data (See Above)
Standby
SR.3 =
1
V PP Range Error
Standby
0
SR.1 =
1
Device Protect Error
1
Command Sequence
Error
0
1
SR.4 =
Set Lock-Bit Error
Comments
Check SR.3
1 = VPP Error Detect
Check SR.1
1 = Device Protect Detect
RP# = V IH ,
(Set Master Lock-Bit Operation)
RP# = VHH , Master Lock-Bit Is Set
(Set Block Lock-Bit Operation)
Standby
Check SR.4,5
Both 1 = Command Sequence Error
Standby
Check SR.4
1 = Set Lock-Bit Reset Error
0
SR.4,5 =
Command
SR.5, SR.4, SR.3 and SR.1 are only cleared by the Clear Status
Register command in cases where multiple lock-bits are set before
full status is checked.
If error is detected, clear the Status Register before attempting retry
or other error recovery.
0
Set Lock-Bit Successful
Figure 11. Set Block and Master Lock-Bit Flowchart
26
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Start
Bus
Operation
Write 60H
Command
Comments
Write
Clear Block
Lock-Bits Setup
Data = 60H
Addr = X
Write
Clear Block
Lock-Bits Confirm
Data = D0H
Addr = X
Write D0H
Status Register Data
Read
Read Status
Register
Check SR.7
1 = WSM Ready
0 = WSM Busy
Standby
0
SR.7 =
Write FFH after the Clear Block Lock-Bits operation to place device
to read array mode.
1
Full Status
Check if Desired
Clear Block Lock-Bits
Complete
FULL STATUS CHECK PROCEDURE
Bus
Operation
Read Status Register
Data (See Above)
SR.3 =
1
1
Comments
Standby
Check SR.3
1 = VPP Error Detect
Standby
Check SR.1
1 = Device Protect Detect
RP# = VIH, Master Lock-Bit Is Set
Standby
Check SR.4,5
Both 1 = Command Sequence Error
Standby
Check SR.5
1 = Clear Block Lock-Bits Error
VPP Range Error
0
SR.1=
Command
Device Protect Error
0
1
SR.4,5 =
Command Sequence
Error
0
1
SR.5 =
Clear Block Lock-Bits
Error
SR.5, SR.4, SR.3 and SR.1 are only cleared by the Clear Status
Register command.
If error is detected, clear the Status Register before attempting
retry or other error recovery.
0
Clear Block Lock-Bits
Successful
Figure 12. Clear Block Lock-Bits Flowchart
PRELIMINARY
27
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
5.0
DESIGN CONSIDERATIONS
5.1
Three-Line Output Control
Intel provides three control inputs to accommodate
multiple memory connections: CE#, OE#, and RP#.
Three-line control provides for:
a. Lowest possible memory power dissipation.
b. Data bus contention avoidance.
To use these control inputs efficiently, an address
decoder should enable CE# while OE# should be
connected to all memory devices and the system’s
READ# control line. This assures that only selected
memory devices have active outputs while deselected memory devices are in standby mode.
RP# should be connected to the system
POWERGOOD signal to prevent unintended writes
during system power transitions. POWERGOOD
should also toggle during system reset.
5.2
RY/BY# Hardware Detection
RY/BY# is a full CMOS output that provides a
hardware method of detecting block erase, program
and lock-bit configuration completion. This output
can be directly connected to an interrupt input of
the system CPU. RY/BY# transitions low when the
WSM is busy and returns to VOH when it is finished
executing the internal algorithm. During suspend
and deep power-down modes, RY/BY# remains at
VOH.
5.3
Power Supply Decoupling
Flash memory power switching characteristics
require careful device decoupling. System
designers are interested in three supply current
issues: standby current levels, active current levels
and transient peaks produced by falling and rising
edges of CE# and OE#. Two-line control and proper
decoupling capacitor selection will suppress
transient voltage peaks. Each device should have a
0.1 µF ceramic capacitor connected between its
VCC and GND and between its VPP and GND.
These high-frequency, low-inductance capacitors
should be placed as close as possible to package
leads. Additionally, for every eight devices, a 4.7 µF
electrolytic capacitor should be placed at the array’s
power supply connection between VCC and GND.
The bulk capacitor will overcome voltage slumps
caused by PC board trace inductance.
28
5.4
E
VPP Trace on Printed Circuit
Boards
Updating flash memories that reside in the target
system requires that the printed circuit board
designer pay attention to the VPP power supply
trace. The VPP pin supplies the memory cell current
for byte writing and block erasing. Use similar trace
widths and layout considerations given to the VCC
power bus. Adequate VPP supply traces and
decoupling will decrease VPP voltage spikes and
overshoots.
5.5
VCC, VPP, RP# Transitions
Block erase, program and lock-bit configuration are
not guaranteed if VPP or VCC fall outside of a valid
voltage range (VCC2/3 and VPPH1/2/3) or RP# ≠ VIH or
VHH. If VPP error is detected, status register bit
SR.3 is set to “1” along with SR.4 or SR.5,
depending on the attempted operation. If RP#
transitions to VIL during block erase, program, or
lock-bit configuration, RY/BY# will remain low until
the reset operation is complete. Then, the operation
will abort and the device will enter deep powerdown. The aborted operation may leave data
partially altered. Therefore, the command sequence
must be repeated after normal operation is
restored.
5.6
Power-Up/Down Protection
The device is designed to offer protection against
accidental block erasure, byte writing, or lock-bit
configuration during power transitions. Upon powerup, the device is indifferent as to which power
supply (VPP or VCC) powers-up first. Internal
circuitry resets the CUI to read array mode at
power-up.
A system designer must guard against spurious
writes for VCC voltages above VLKO when VPP is
active. Since both WE# and CE# must be low for a
command write, driving either input signal to VIH will
inhibit writes. The CUI’s two-step command
sequence architecture provides an added level of
protection against data alteration.
In-system block lock and unlock renders additional
protection during power-up by prohibiting block
erase and program operations. The device is
disabled while RP# = VIL regardless of its control
inputs state.
PRELIMINARY
E
5.7
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
VPP Program and Erase
Voltages on Sub-0.4µ SC
Memory Family
Intel's SmartVoltage FlashFile™ memory family
provides in-system program/erase at 3.3 V VPP and
5V VPP as well as faster factory program/erase at
12 V VPP.
Future sub-0.4µ lithography SmartVoltage FlashFile
memory products will also include a backwardcompatible 12 V programming feature. This mode,
however, is not intended for extended use. A 12 V
program/erase VPP can be applied for 1000 cycles
maximum per block or 80 hours maximum per
device. To ensure compatibility with future sub-0.4µ
SmartVoltage FlashFile memory products, present
designs should not permanently connect VPP to
12 V. This will avoid device over-stressing that may
cause permanent damage.
PRELIMINARY
29
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
6.0
ELECTRICAL SPECIFICATIONS
6.1
Absolute Maximum Ratings*
NOTICE: This datasheet contains information on new
products in production. Do not finalize a design with this
information. Revised information will be published when
the product is available. Verify with your local Intel Sales
office that you have the latest datasheet before finalizing a
design.
Temperature under Bias ................ –10°C to +80°C
Storage Temperature....................–65°C to +125°C
*WARNING: Stressing the device beyond the “Absolute
Maximum Ratings” may cause permanent damage. These
are stress ratings only. Operation beyond the “Operating
Conditions” is not recommended and extended exposure
beyond the “Operating Conditions” may affect device
reliability.
Voltage on Any Pin
(except VPP, and RP#) ......... –2.0 V to +7.0 V(1)
VPP Voltage ........................... –2.0 V to +14.0 V (1,2)
RP# Voltage ........................ –2.0 V to +14.0 V(1,2,4)
Output Short Circuit Current ....................100 mA(3)
NOTES:
1. All specified voltages are with respect to GND. Minimum DC voltage is –0.5 V on input/output pins and –0.2 V on VCC, RP#,
and VPP pins. During transitions, this level may undershoot to –2.0 V for periods <20 ns. Maximum DC voltage on
input/output pins and VCC is VCC +0.5 V which, during transitions, may overshoot to VCC +2.0 V for periods <20 ns.
2. Maximum DC voltage on VPP and RP# may overshoot to +14.0 V for periods <20 ns.
3. Output shorted for no more than one second. No more than one output shorted at a time.
4. RP# voltage is normally at VIL or VIH. Connection to supply of VHH is allowed for a maximum cumulative period of 80 hours.
6.2
Commercial Temperature Operating Conditions
Commercial Temperature and VCC Operating Conditions
Symbol
Parameter
Notes
Min
Max
Unit
0
+70
°C
2.7
3.6
V
TA
Operating Temperature
VCC1
VCC Supply Voltage (2.7 V–3.6 V)
VCC2
VCC Supply Voltage (3.3 V ± 0.3 V)
3.0
3.6
V
VCC3
VCC Supply Voltage (5 V ± 5%)
4.75
5.25
V
VCC4
VCC Supply Voltage (5 V ± 10%)
4.5
5.5
V
1
Test Condition
Ambient Temperature
NOTE:
1. Block erase, program, and lock-bit configuration with VCC < 3.0 V should not be attempted.
Capacitance(1)
6.3
TA = +25°C, f = 1 MHz
Symbol
Parameter
Typ
Max
Unit
Condition
CIN
Input Capacitance
6
8
pF
VIN = 0.0 V
COUT
Output Capacitance
8
12
pF
VOUT = 0.0 V
NOTE:
1. Sampled, not 100% tested.
30
PRELIMINARY
E
6.4
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
DC Characteristics—Commercial Temperature
2.7V VCC 3.3V VCC
Parameter
Sym
ILI
Input Load Current
ILO
Output Leakage Current
ICCS
VCC Standby Current
5V VCC
Test
Notes Typ Max Typ Max Typ Max Unit
±0.5
1
±0.5
±1
±0.5
Conditions
µA VCC = VCC Max, VIN = VCC or GND
±10
µA VCC = VCC Max, VOUT = VCC or GND
20
100
20
100
25
100
µA CMOS Inputs
VCC = VCC Max
0.1
2
0.2
2
0.4
2
mA TTL Inputs
VCC = VCC Max, CE# = RP# = VIH
10
µA RP# = GND ± 0.2 V
IOUT (RY/BY#) = 0 mA
1
1,3,6
±0.5
CE# = RP# = VCC ± 0.2 V
ICCD
VCC Deep Power-
1
10
10
Down Current
ICCR
ICCW
VCC Read Current
VCC Program or
1,5,6
1,7
Set Lock-Bit Current
ICCE
6
12
7
12
17
35
mA CMOS Inputs
VCC = VCC Max, CE# = GND
f = 5 MHz (2.7 V, 3.3 V), 8 MHz (5 V)
IOUT = 0 mA
7
18
8
18
20
50
mA TTL Inputs
VCC = VCC Max, CE# = GND
f = 5 MHz (2.7 V, 3.3 V), 8 MHz (5 V)
IOUT = 0 mA


17


mA VPP = 3.3 V ± 0.3 V


17
35
mA VPP = 5 V ± 10%


12
30
mA VPP = 12 V ± 5%


17

mA VPP = 3.3 V ± 0.3 V
Clear Block


17
30
mA VPP = 5 V ± 10%
Lock-Bits Current


12
25
mA VPP = 12 V ± 5%
1,2


1
10
mA CE# = VIH
VCC Block Erase or
ICCWS VCC Program or Block
ICCES Erase Suspend Current
1,7
6

1
IPPS
VPP Standby Current
1
±2
±15
±2
±15 ± 2 ±15
µA VPP ≤ VCC
IPPR
VPP Read Current
1
10
200
10
200
10
200
µA VPP > VCC
IPPD
VPP Deep Power-Down
Current
1
0.1
5
0.1
5
0.1
5
µA RP# = GND ± 0.2 V
IPPW
VPP Program/ Set
1,7


40



40


15


20
Block Lock-Bits


Current




Lock-Bit Current
IPPE
VPP Block Erase/Clear
IPPWS VPP Program/ Block Erase
Suspend Current
I
1,7
1
10

mA VPP = 3.3 V ± 0.3 V
40
mA VPP = 5 V ± 10%
15
mA VPP = 12 V ± 5%

mA VPP = 3.3 V ± 0.3 V
20
20
mA VPP = 5 V ± 10%
15
15
mA VPP = 12 V ± 5%
200
µA VPP = VPPH1/2/3
200

10
PPES
PRELIMINARY
31
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
6.4
DC Characteristics—Commercial Temperature(Continued)
2.7 V VCC 3.3 V VCC 5 V VCC
Sym
Parameter
Test
Notes Min Max Min Max Min Max Unit
VIL
Input Low Voltage
7
–0.5 0.8 –0.5 0.8 –0.5 0.8
V
VIH
Input High Voltage
7
2.0 VCC 2.0 VCC 2.0 VCC
V
VOL
+ 0.5
+ 0.5
+ 0.5
0.4
0.4
0.45
Output Low Voltage
3,7
VOH1 Output High Voltage (TTL)
3,7
2.4
2.4
VOH2 Output High Voltage
(CMOS)
3,7
0.85
VCC
VCC
–0.4
VPPLK VPP Lockout Voltage
V
VCC = VCC Min
IOL = 2 mA (2.7V, 3.3V)
5.8 mA (5V)
2.4
V
VCC = VCC Min
IOH = –2.5 mA
0.85
VCC
0.85
VCC
V
VCC = VCC Min
IOH = –2.5 mA
VCC
–0.4
VCC
–0.4
V
VCC = VCC Min
IOH = –100 µA
1.5
V
VPPH1 VPP Voltage


3.0
3.6


V
VPPH2 VPP Voltage


4.5
5.5
4.5
5.5
VPPH3 VPP Voltage


11.4 12.6 11.4 12.6
V
VLKO VCC Lockout Voltage
2.0
2.0
V
VHH
RP# Unlock Voltage
4,7
8,9
1.5


Conditions
1.5
2.0
11.4 12.6 11.4 12.6
V
Set Master Lock-Bit
Override Lock-Bit
NOTES:
1. All currents are in RMS unless otherwise noted. Typical values at nominal VCC voltage and TA = +25°C. These currents are
valid for all product versions (packages and speeds).
2. ICCWS and ICCES are specified with the device de-selected. If read or written while in erase suspend mode, the device’s
current is the sum of ICCWS or ICCES and ICCR or ICCW.
3. Includes RY/BY#.
4. Block erases, programs, and lock-bit configurations are inhibited when VPP ≤ VPPLK, and not guaranteed in the range
between VPPLK (max) and VPPH1 (min), between VPPH1 (max) and VPPH2 (min), between VPPH2 (max) and VPPH3 (min), and
above VPPH3 (max).
5. Automatic Power Savings (APS) reduces typical ICCR to 1 mA at 5 V and 3 mA at 2.7 V and 3.3 V VCC in static operation.
6. CMOS inputs are either VCC ± 0.2 V or GND ± 0.2 V. TTL inputs are either VIL or VIH.
7. Sampled, not 100% tested.
8. Master lock-bit set operations are inhibited when RP# = VIH. Block lock-bit configuration operations are inhibited when the
master lock-bit is set and RP# = VIH. Block erases and programs are inhibited when the corresponding block-lock bit is set
and RP# = VIH. Block erase, program, and lock-bit configuration operations are not guaranteed and should not be
attempted with VIH < RP# < VHH.
9. RP# connection to a VHH supply is allowed for a maximum cumulative period of 80 hours.
32
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
2.7
INPUT
1.35
TEST POINTS
1.35
OUTPUT
0.0
AC test inputs are driven at 2.7 V for a Logic "1" and 0.0 V for a Logic "0." Input timing begins, and output timing ends, at 1.35
V. Input rise and fall times (10% to 90%) <10 ns.
Figure 13. Transient Input/Output Reference Waveform for VCC = 2.7 V−3.6 V
3.0
INPUT
1.5
TEST POINTS
OUTPUT
1.5
0.0
AC test inputs are driven at 3.0 V for a Logic "1" and 0.0 V for a Logic "0." Input timing begins, and output timing ends, at 1.5 V.
Input rise and fall times (10% to 90%) <10 ns.
Figure 14. Transient Input/Output Reference Waveform for VCC = 3.3 V ± 0.3 V and V CC = 5.0 V ± 5%
(High Speed Testing Configuration)
2.4
2.0
INPUT
2.0
OUTPUT
TEST POINTS
0.8
0.45
0.8
AC test inputs are driven at VOH (2.4 VTTL) for a Logic "1" and VOL (0.45 VTTL) for a Logic "0." Input timing begins at VIH
(2.0 VTTL) and VIL (0.8 VTTL). Output timing ends at VIH and VIL. Input rise and fall times (10% to 90%) <10 ns.
Figure 15. Transient Input/Output Reference Waveform for VCC = 5.0 V ± 10%
(Standard Testing Configuration)
Test Configuration Capacitance Loading Value
1.3V
Test Configuration
1N914
R L = 3.3 K
DEVICE
UNDER
TEST
OUT
CL (pF)
VCC = 3.3 V ± 0.3 V, 2.7 V−3.6 V
50
VCC = 5 V ± 5%
30
VCC = 5 V ± 10%
100
CL
NOTE:
CL includes Jig Capacitance
Figure 16. Transient Equivalent Testing
Load Circuit
PRELIMINARY
33
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
RY/BY# (R)
VIH
VIL
P2
RP# (P)
VIH
VIL
P1
Figure 17. AC Waveform for Reset Operation
Table 8. Reset Specifications
2.7 V VCC
#
Sym
Parameter
P1 tPLPH RP# Pulse Low Time (If RP# is tied to VCC,
this specification is not applicable)
P2 tPLRH RP# Low to Reset during Block Erase,
Program, or Lock-Bit Configuration
3.3 V VCC
5 V VCC
Notes Min Max Min Max Min Max Unit
100
2,3
100

100
20
ns
12
µs
NOTES:
1. These specifications are valid for all product versions (packages and speeds).
2. If RP# is asserted when the WSM is not busy (RY/BY# = “1”), the reset will complete within 100 ns.
3. A reset time, tPHQV, is required from the latter of RY/BY# or RP# going high until outputs are valid.
34
PRELIMINARY
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
AC Characteristics—Read-Only Operations(1)—Commercial Temperature
6.5
TA = 0°C to +70°C
Versions(4)
#
Sym
R1 tAVAV
5 V ± 5% VCC
-85/-95(5)




5 V ± 10% VCC

-90/-100(6)
-120


3.3 V ± 0.3 V VCC


-120
-150

2.7 V−3.6 V VCC



-150
-170
Parameter
Notes Min Max Min Max Min Max Min Max Min Max
Read Cycle
4, 8 Mbit
85
90
120
150
170
ns
Time
16 Mbit
95
100
120
150
170
ns
R2 tAVQV Address to
4, 8 Mbit
Output Delay 16 Mbit
R3 tELQV
Unit
85
90
120
150
170
ns
95
100
120
150
170
ns
CE# to Output 4, 8 Mbit
2
85
90
120
150
170
ns
Delay
2
95
100
120
150
170
ns
2
40
45
50
55
55
ns
400
400
400/
600(7)
600
600
ns
16 Mbit
R4 tGLQV OE# to Output Delay
R5 tPHQV RP# High to Output
Delay
CE# to Output in Low Z
3
0
0
0
0
0
R7 tGLQX OE# to Output in Low Z
3
0
0
0
0
0
R8 tEHQZ CE# High to Output in
High Z
3
55
55
55
55
55
ns
R9 tGHQZ OE# High to Output in
High Z
3
10
10
15
20
25
ns
R10 tOH
3
R6 tELQX
Output Hold from
Address, CE# or OE#
Change, Whichever
Occurs First
0
0
0
0
0
ns
ns
ns
NOTES:
1. See AC Input/Output Reference Waveform for maximum allowable input slew rate.
2. OE# may be delayed up to tELQV–tGLQV after the falling edge of CE# without impact on tELQV.
3. Sampled, not 100% tested.
4. See Ordering Information for device speeds (valid operational combinations).
5. See Transient Input/Output Reference Waveform and Transient Equivalent Testing Load Circuit (High Speed
Configuration) for testing characteristics.
6. See Transient Input/Output Reference Waveform and Transient Equivalent Testing Load Circuit (Standard Configuration)
for testing characteristics.
7. Valid for 3.3 V VCC read operations.
PRELIMINARY
35
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
VIH
Standby
ADDRESSES (A)
CE# (E)
Data
Valid
Device
Address Selection
Address Stable
VIL
VIH
R1
VIL
OE# (G)
WE# (W)
R2
R8
VIL
VIH
R3
R9
VIL
VOH
R5
VIH
R4
R10
R6
DATA (D/Q)
High Z
Valid Output
(DQ0-DQ7)
VOL
High Z
R7
V CC
RP# (P)
VIH
VIL
Figure 18. AC Waveform for Read Operations
36
PRELIMINARY
E
6.6
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
AC Characteristics—Write Operations(1,2)—Commercial Temperature
TA = 0°C to +70°C

5 V ± 5%,
Valid for All
5 V ± 10% VCC
Speeds
#
Sym
W1
tPHWL (tPHEL)
W2
tELWL (tWLEL)
W3
W4
W5
W6

3.3 V ± 0.3 V,
2.7 V−3.6 V VCC
Versions
Parameter
Notes Min
Valid for All
Speeds
Unit
Max
Min
Max
3
1
1
µs
7
0
0
ns
tWP
RP# High Recovery to WE# (CE#) Going
Low
CE# (WE#) Setup to WE# (CE#) Going
Low
Write Pulse Width
7
50
70
ns
tDVWH (tDVEH)
Data Setup to WE# (CE#) Going High
4
40
50
ns
tAVWH (tAVEH)
Address Setup to WE# (CE#) Going High
4
40
50
ns
tWHEH (tEHWH)
CE# (WE#) Hold from WE# (CE#) High
0
0
ns
W7
tWHDX (tEHDX)
Data Hold from WE# (CE#) High
5
5
ns
W8
tWHAX (tEHAX)
Address Hold from WE# (CE#) High
5
5
ns
W9
tWPH
Write Pulse Width High
9
25
25
ns
W10 tPHHWH (tPHHEH) RP# VHH Setup to WE# (CE#) Going High
3,8
100
100
ns
W11 tVPWH (tVPEH)
VPP Setup to WE# (CE#) Going High
3,8
100
100
ns
W12 tWHGL (tEHGL)
Write Recovery before Read
0
0
ns
W13 tWHRL (tEHRL)
WE# (CE#) High to RY/BY# Going Low
8
W14 tQVPH
RP# VHH Hold from Valid SRD, RY/BY#
High
VPP Hold from Valid SRD, RY/BY# High
3,5,8
0
0
ns
3,5,8
0
0
ns
W15 tQVVL
90
90
ns
NOTES:
1. Read timing characteristics during block erase, program, and lock-bit configuration operations are the same as during
read-only operations. Refer to AC Characteristics for read-only operations.
2. A write operation can be initiated and terminated with either CE# or WE#.
3. Sampled, not 100% tested.
4. Refer to Table 4 for valid AIN and DIN for block erase, program, or lock-bit configuration.
5. VPP should be held at VPPH1/2/3 (and if necessary RP# should be held at VHH) until determination of block erase, program,
or lock-bit configuration success (SR.1/3/4/5 = 0).
6. See Ordering Information for device speeds (valid operational combinations).
7. Write pulse width (tWP) is defined from CE# or WE# going low (whichever goes low last) to CE# or WE# going high
(whichever goes high first). Hence, tWP = tWLWH = tELEH = tWLEH = tELWH. If CE# is driven low 10 ns before WE# going low,
WE# pulse width requirement decreases to tWP – 10 ns for 5 V VCC and tWP – 20 ns for 2.7 V and 3.3 V VCC writes.
8. Block erase, program, and lock-bit configuration with VCC < 3.0 V should not be attempted.
9. Write pulse width high (tWPH) is defined from CE# or WE# going high (whichever goes high first) to CE# or WE# going low
(whichever goes low last). Hence, tWPH = tWHWL = tEHEL = tWHEL = tEHWL.
PRELIMINARY
37
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
ADDRESSES [A]
VIH
A
VIL
C
AIN
AIN
D
E
F
W8
W5
VIH
CE# (WE#) [E(W)]
B
VIL
W6
W1
VIH
OE# [G]
W12
VIL
W9
W2
VIH
W16
WE# (CE#) [W(E)]
VIL
W3
W4
VIH
DATA [D/Q]
W7
High Z
VIL
DIN
W13
VIH
RY/BY# [R]
Valid
SRD
DIN
DIN
VIL
W10
W14
VHH
VIH
RP# [P]
VIL
V
VPP [V]
W11
W15
PPH2,1
VPPLK
VIL
NOTES:
A. VCC power-up and standby.
B. Write block erase or program setup.
C. Write block erase confirm or valid address and data..
D. Automated erase or program delay.
E. Read status register data.
F. Write Read Array command.
Figure 19. AC Waveform for Write Operations
38
PRELIMINARY
E
6.7
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
Block Erase, Program, and Lock-Bit Configuration Performance(3, 4, 5)—
Commercial Temperature
VCC = 3.3 V ± 0.3 V, T A = 0°C to +70°C
3.3 V VPP
#
Sym
W16 tWHRH1,
tEHRH1
W16 tWHRH2,
tEHRH2
W16 tWHRH3,
tEHRH3
W16 tWHRH4,
tEHRH4
W16 tWHRH5,
tEHRH5
W16 tWHRH6,
tEHRH6
Parameter
5 V VPP
12 V VPP
Notes
Typ(1)
Max
Typ(1)
Max
Typ(1)
Max
Unit
Program Time
2
19
300
10
150
7
125
µs
Block Write Time
Block Erase Time
2
2
1.2
0.8
4
6
0.7
0.4
2
5
0.5
0.3
1.5
4
sec
sec
Set Lock-Bit Time
2
21
TBD
13.3
TBD
11.6
TBD
µs
Clear Block LockBits Time
Program Suspend
Latency Time to
Read
Erase Suspend
Latency Time to
Read
2
1.8
TBD
1.2
TBD
1.1
TBD
sec
7.1
10
6.6
9.3
7.4
10.4
µs
15.2
21.1
12.3
17.2
12.3
17.2
µs
VCC = 5 V ± 5%, 5 V ± 10%, T A = 0°C to +70°C
5 V VPP
#
Sym
W16 tWHRH1,
tEHRH1
W16 tWHRH2,
tEHRH2
W16 tWHRH3,
tEHRH3
W16 tWHRH4,
tEHRH4
W16 tWHRH5,
tEHRH5
W16 tWHRH6,
tEHRH6
Parameter
Notes
12 V VPP
Typ(1) Max
Typ(1) Max Unit
Program Time
2
8
150
6
100
µs
Block Write Time
Block Erase Time
2
2
0.5
0.4
1.5
5
0.4
0.3
1
4
sec
sec
Set Lock-Bit Time
2
12
TBD
10
TBD
µs
Clear Block Lock-Bits Time
2
1.1
TBD
1.0
TBD sec
5.6
7
5.2
7.5
µs
9.4
13.1
9.8
12.6
µs
Program Suspend Latency Time to
Read
Erase Suspend Latency Time to
Read
NOTES:
1. Typical values measured at TA = +25°C and nominal voltages. Assumes corresponding lock-bits are not set. Subject to
change based on device characterization.
2. Excludes system-level overhead.
3. These performance numbers are valid for all speed versions.
4. Sampled, but not 100% tested.
5. Reference the AC Waveform for Write Operations, Figure 19.
PRELIMINARY
39
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
6.8
Extended Temperature Operating Conditions
Except for the specifications given in this section, all DC and AC characteristics are identical to those give in
commercial temperature specifications. See the Section 6.2 for commercial temperature specifications.
Extended Temperature and VCC Operating Conditions
Symbol
TA
6.9
Parameter
Notes
Operating Temperature
Min
Max
Unit
–40
+85
°C
Test Condition
Ambient Temperature
DC Characteristics—Extended Temperature
Parameter
Sym
2.7V VCC 3.3V VCC 5V VCC
Test
Notes Typ Max Typ Max Typ Max Unit
Conditions
ICCD VCC Deep Power-Down
Current
1
20
20
20
µA RP# = GND ± 0.2 V
IOUT (RY/BY#) = 0 mA
NOTE:
1. All currents are in RMS unless otherwise noted. These currents are valid for all product versions (packages and speeds).
Contact Intel’s Application Support Hotline or your local sales office for information about typical specifications.
6.10
AC Characteristics—Read-Only Operations(1) — Extended Temperature
TA = –40°C to +85°C
Versions(3)
5 V ± 10% VCC
-100/-110


3.3 V ± 0.3 V VCC

-150


2.7 V−3.6 V VCC
#
Sym
R1 tAVAV
Parameter
Read Cycle Time
Min

Max
Min
-170
Max
Min
Max
4, 8 Mbit
100
150
170
ns
16 Mbit
110
150
170
ns
R2 tAVQV Address to Output
4, 8 Mbit
Delay
16 Mbit
R3 tELQV
Notes
Unit
CE# to Output Delay 4, 8 Mbit
16 Mbit
100
150
170
ns
ns
110
150
170
2
100
150
170
ns
2
110
150
170
ns
NOTES:
1. See AC Input/Output Reference Waveform for maximum allowable input slew rate.
2. OE# may be delayed up to tELQV-tGLQV after the falling edge of CE# without impact on tELQV.
3. See Ordering Information for device speeds (valid operational combinations).
40
PRELIMINARY
E
7.0
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
ORDERING INFORMATION
Product line designator for all Intel Flash products
E2 8 F0 0 4 SC- 0 8 5
Operating Temperature/Package
E = Comm. Temp. 40-Lead TSOP
TE = Extended Temp. 40-Lead TSOP
PA = Comm. Temp 44-Lead PSOP
TB = Ext. Temp 44-Lead PSOP
G = Comm. Temp. 40-Ball µBGA* CSP
Access Speed (ns)
85 ns (5 V, 30 pF), 90 ns (5 V)
120 ns (3.3 V), 150 ns (2.7 V)
Voltage Options (V CC/VPP)
C = SmartVoltage Flash
(2.7 V, 3.3 V and
5 V/3.3 V, 5 V and 12 V)
Device Density
004 = 4 Mbit
008 = 8 Mbit
016 = 16 Mbit
Product Family
S = FlashFile™ Memory
Valid Operational Combinations
Order Code by Density
4-Mbit
8-Mbit
E28F004SC-85
E28F004SC-120
PA28F004SC-85
PA28F004SC-120
E28F008SC-85
E28F008SC-120
PA28F008SC-85
PA28F008SC-120
5V VCC
16-Mbit
2.7V VCC, 3.3V VCC, 10% VCC, 5% VCC,
50pF load 50pF load 100pF load 30pF load
-120
-150
-120
-150
-90/-100(1)
-120
-90/-100(1)
-120
G28F008SC-120
Commercial Temperature
E28F016SC-95
-150
E28F016SC-120
-170
PA28F016SC-95
-150
PA28F016SC-120
-170
-170
G28F016SC-120
–150
–120
G28F008SC-150
-170
–150
–120
Extended Temperature
TE28F004SC-100 TE28F008SC-100 TE28F016SC-110
-170
TB28F004SC-100 TB28F008SC-100 TB28F016SC-110
-170
-150
-150
-100/-110(1)
-100/-110(1)
G28F016SC-150
-85/95(1)
-85/95(1)
NOTE:
1. Valid access time for 16-Mbit byte-wide FlashFile memory.
PRELIMINARY
41
E
BYTE-WIDE SmartVoltage FlashFile™ MEMORY FAMILY
8.0
ADDITIONAL INFORMATION
Order Number
Document/Tool
290598
Byte-Wide Smart3 FlashFile Memory Family Datasheet
290597
Byte-Wide Smart5 FlashFile Memory Family Datasheet
292183
AB-64 4-, 8-, 16-Mbit Byte-Wide FlashFile™ Memory Family Overview
292094
AP-359 28F008SA Hardware Interfacing
292099
AP-364 28F008SA Automation and Algorithms
292123
AP-374 Flash Memory Write Protection Techniques
292180
AP-625 28F008SC Compatibility with 28F008SA
292182
AP-627 Byte-Wide FlashFile™ Memory Family Software Drivers
297729
Byte-Wide SmartVoltage FlashFile™ Memory Family Specification Update
Contact Intel/Distribution 4-, 8-, and 16-Mbit Schematic Symbols
Sales Office
Contact Intel/Distribution 4-, 8-, and 16-Mbit TimingDesigner* Files
Sales Office
Contact Intel/Distribution 4-, 8-, and 16-Mbit VHDL and Verilog Models
Sales Office
Contact Intel/Distribution 4-, 8-, and 16-Mbit iBIS Models
Sales Office
NOTE:
1. Please call the Intel Literature Center at (800) 548-4725 to request Intel documentation. International customers should
contact their local Intel or distribution sales office.
2. Visit Intel’s World Wide Web home page at http://www.Intel.com for technical documentation and tools.
42
PRELIMINARY