MOSEL V82658B04S

V82658B04S
64 MB 200-PIN DDR UNBUFFERED SODIMM
2.5 VOLT 8M x 64
MOSEL VITELIC
PRELIMINARY
Features
Description
■ JEDEC 200 Pin DDR Unbuffered Small-Outline,
Dual In-Line memory module (SODIMM);
8,388,608 x 64 bit organization.
■ Utilizes High Performance 8M x 16 DDR
SDRAM in TSOPII-66 Packages
■ Single +2.5V (± 0.2V) Power Supply
■ Programmable CAS Latency, Burst Length, and
Wrap Sequence (Sequential & Interleave)
■ Auto Refresh (CBR) and Self Refresh
■ All Inputs, Outputs are SSTL-2 Compatible
■ 4096 Refresh Cycles every 64 ms
■ Serial Presence Detect (SPD)
■ DDR SDRAM Performance
The V82658B04S memory module is organized
8,388,608 x 64 bits in a 200 pin memory module.
The 8M x 64 memory module uses 4 Mosel-Vitelic
8M x 16 DDR SDRAM. The x64 modules are ideal
for use in high performance computer systems
where increased memory density and fast access
times are required.
Component Used
tCK
tAC
Clock Frequency
(max.)
Clock Access Time
CAS Latency = 2.5
-7
-75
-8
Units
143
133
125
MHz
(PC266A) (PC266B) (PC200)
7
7.5
8
ns
Module Speed
A1
PC1600 (100MHz @ CL2)
B0
PC2100B (133MHz @ CL2.5)
B1
PC2100A (133MHz @ CL2)
V82658B04S Rev. 1.2 March 2002
1
V82658B04S
MOSEL VITELIC
Part Number Information
V
8
2
65
8
B
0
4
S
DDRSDRAM
2.5V
T
G - XX
COMPONENT
PACKAGE, T = TSOP
WIDTH
DEPTH
COMPONENT
REV LEVEL
200 PIN Unbuffered
SODIMM X16 COMPONENT
STTL
REFRESH
RATE 4K
V82658B04S Rev. 1.2 March 2002
X
SPEED
A1 (100MHZ@CL2)
B0 ([email protected])
B1 (133MHZ@CL2)
LEAD FINISH
G = GOLD
MOSEL VITELIC
MANUFACTURED
2
4 BANKS
V82658B04S
MOSEL VITELIC
Block Diagram
S0
DQS0
DM0
LDQS
LDM
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
DQS1
DM1
DQ8
DQ9
DQ10
DQ11
DQ12
DQ13
DQ14
DQ15
DQS2
DM2
I/O 0
I/O 1
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 7
UDQS
UDM
I/O 8
I/O 9
I/O 10
I/O 11
I/O 12
I/O 13
I/O 14
I/O 15
LDQS
LDM
DQ16
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
DQS3
DM3
DQ24
DQ25
DQ26
DQ27
DQ28
DQ29
DQ30
DQ31
I/O 0
I/O 1
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 7
UDQS
UDM
I/O 8
I/O 9
I/O 10
I/O 11
I/O 12
I/O 13
I/O 14
I/O 15
DQS4
DM4
S
LDQS
LDM
DQ32
DQ33
DQ34
DQ35
DQ36
DQ37
DQ38
DQ39
D0
DQS5
DM5
DQ40
DQ41
DQ42
DQ43
DQ44
DQ45
DQ46
DQ47
DQS6
DM6
S
I/O 0
I/O 1
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 7
UDQS
UDM
I/O 8
I/O 9
I/O 10
I/O 11
I/O 12
I/O 13
I/O 14
I/O 15
LDQS
LDM
DQ48
DQ49
DQ50
DQ51
DQ52
DQ53
DQ54
DQ55
D1
DQS7
DM7
DQ56
DQ57
DQ58
DQ58
DQ60
DQ61
DQ62
DQ63
I/O 0
I/O 1
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 7
UDQS
UDM
I/O 8
I/O 9
I/O 10
I/O 11
I/O 12
I/O 13
I/O 14
I/O 15
S
D2
S
D3
*Clock Net Wiring
Dram1
BA0 - BA1
BA0-BA1: DDR SDRAMs D0 - D3
A0 - A13
A0-A13: DDR SDRAMs D0 - D3
RAS
RAS: SDRAMs D0 - D3
CAS
CAS: SDRAMs D0 - D3
CKE0
CKE: SDRAMs D0 - D3
WE
WE: SDRAMs D0 - D3
VDDSPD
VDD/VDDQ
Clock
Input
CK0/CK0
CK1/CK1
CK2/CK2
Card
Edge
SDRAMs
2 SDRAMs
2 SDRAMs
NC
Dram3
Cap
SPD
D0 - D3
Serial PD
VREF
D0 - D3
SCL
VSS
D0 - D3
WP
V82658B04S Rev. 1.2 March 2002
Cap
CK
CK
Clock Wiring
D0 - D3
VDDID
R=120Ω
± 5%
Strap: see Note 4
SDA
A0
A1
A2
SA0
SA1
SA2
3
Notes:
1. DQ-to-I/O wiring is shown as recommended but may be changed.
2. DQ/DQS/DM/CKE/CS relationships must
be maintained as shown.
3. DQ, DQS, DM/DQS resistors: 22 Ohms.
4. VDDID strap connections
(for memory device VDD, VDDQ):
STRAP OUT (OPEN): VDD = VDDQ
STRAP IN (VSS): VDD ≠ VDDQ.
V82658B04S
MOSEL VITELIC
Pin Configurations (Front Side/Back Side)
Pin
Front
Pin
Front
Pin
Front
Pin
Back
Pin
Back
Pin
Back
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
VREF
VSS
DQ0
DQ1
VDD
DQS0
DQ2
VSS
DQ3
DQ8
VDD
DQ9
DQS1
VSS
DQ10
DQ11
VDD
CK0
CK0
VSS
67
69
71
73
75
77
79
81
83
85
87
89
91
93
95
97
99
101
103
105
107
109
111
113
115
117
119
121
123
125
127
129
131
133
DQ27
VDD
CB0
CB1
VSS
DQS8
CB2
VDD
CB3
DU
VSS
CK2
CK2
VDD
CKE1
DU(A13)
A12
A9
VSS
A7
A5
A3
A1
VDD
A10/AP
BA0
WE
S0
DU
VSS
DQ32
DQ33
VDD
DQS4
135
137
139
141
143
145
147
149
151
153
155
157
159
161
163
165
167
169
171
173
175
177
179
181
183
185
187
189
191
193
195
197
199
DQ34
VSS
DQ35
DQ40
VDD
DQ41
DQS5
VSS
DQ42
DQ43
VDD
VDD
VSS
VSS
DQ48
DQ49
VDD
DQS6
DQ50
VSS
DQ51
DQ56
VDD
DQ57
DQS7
DQ58
DQ58
DQ59
VDD
SDA
SCL
VDDSPD
VDDID
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
VREF
VSS
DQ4
DQ5
VDD
DM0
DQ6
VSS
DQ7
DQ12
VDD
DQ13
DM1
VSS
DQ14
DQ15
VDD
VDD
VSS
VSS
68
70
72
74
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
122
124
126
128
130
132
134
DQ31
VDD
CB4
CB5
VSS
DM8
CB6
VDD
CB7
DU/(RESET)
VSS
VSS
VDD
VDD
CKE0
DU(BA2)
A11
A8
VSS
A6
A4
A2
A0
VDD
BA1
RAS
CAS
S1
DU
VSS
DQ36
DQ37
VDD
DM4
136
138
140
142
144
146
148
150
152
154
156
158
160
162
164
166
168
170
172
174
176
178
180
182
184
186
188
190
192
194
196
198
200
DQ38
VSS
DQ39
DQ44
VDD
DQ45
DM5
VSS
DQ46
DQ47
VDD
CK1
CK1
VSS
DQ52
DQ53
VDD
DM6
DQ54
VSS
DQ55
DQ60
VDD
DQ61
DM7
VSS
DQ62
DQ63
VDD
SA0
SA1
SA2
DU
Key
41
43
45
47
49
51
53
55
57
59
61
63
65
DQ16
DQ17
VDD
DQS2
DQ18
VSS
DQ19
DQ24
VDD
DQ25
DQS3
VSS
DQ26
Key
42
44
46
48
50
52
54
56
58
60
62
64
66
DQ20
DQ21
VDD
DM2
DQ22
VSS
DQ23
DQ28
VDD
DQ29
DM3
VSS
DQ30
Notes:
*
These pins are not used in this module.
Pin Names
Pin
Pin Description
Pin
Pin Description
A0~A11
Address Input (Multiplexed)
VDD
Power Supply (2.5V)
BA0~BA1
Bank Select Address
VDDQ
Power Supply for DQS(2.5V)
DQ0~DQ63
Data Input/Output
VSS
Ground
DQS0~DQS7
Data Strobe Input/Output
VREF
Power Supply for Reference
CK0~CK2, CK0~CK2,
Clock Input
VDDSPD
CKE0
Clock Enable Input
Serial EEPOM Power Supply (2.3V
to 3.6V)
CS0
Chip Select Input
SDA
Serial Data I/O
RAS
Row Address Strobe
SCL
Serial Clock
CAS
Column Address Strobe
SA0~2
Address in EEPROM
WE
Write Enable
VDDID
VDD Identification Flag
DM0~DM7
Data - In Mask
NC
No Connection
V82658B04S Rev. 1.2 March 2002
4
V82658B04S
MOSEL VITELIC
Serial Presence Detect Information
Bin Sort:
A1 (PC1600 @ CL2)
B0 (PC2100B @ CL2.5)
B1 (PC2100A @ CL2)
Function Supported
Byte #
Function described
0
Defines # of Bytes written into serial memory at module manufacturer
128bytes
80h
1
Total # of Bytes of SPD memory device
256bytes
08h
2
Fundamental memory type
SDRAM DDR
07h
3
# of row address on this assembly
12
0Ch
4
# of column address on this assembly
9
09h
5
# of module Rows on this assembly
1Bank
01h
6
Data width of this assembly
64 bits
40h
7
Data width of this assembly
-
00h
8
VDDQ and interface standard of this assembly
SSTL 2.5V
04h
9
DDR SDRAM cycle time at CAS Latency =2.5
10
DDR SDRAM Access time from clock at CL=2.5
11
DIMM configuration type(Non-parity, Parity, ECC)
12
Refresh rate & type
13
A1
B0
8ns
7.5ns
B1
Hex value
7ns
±0.8ns ±0.75ns ±0.70ns
A1
B0
B1
80h
75h
70h
80h
75h
70h
Non-parity, ECC
00
15.6us & Self refresh
80h
Primary DDR SDRAM width
x16
10h
14
Error checking DDR SDRAM data width
x0
00h
15
Minimum clock delay for back-to-back random column
address
tCCD =1CLK
01h
16
DDR SDRAM device attributes : Burst lengths supported
2,4,8
0Eh
17
DDR SDRAM device attributes : # of banks on each DDR SDRAM
4 banks
04h
18
DDR SDRAM device attributes : CAS Latency supported
2,2.5
0Ch
19
DDR SDRAM device attributes : CS Latency
0CLK
01h
20
DDR SDRAM device attributes : WE Latency
1CLK
02h
21
DDR SDRAM module attributes
Unbuffered
Diff Clock
20h
22
DDR SDRAM device attributes : General
+/-0.2V voltage tolerance
00h
23
DDR SDRAM cycle time at CL =2
24
DDR SDRAM Access time from clock at CL =2
25
DDR SDRAM cycle time at CL =1.5
-
-
-
00h
26
DDR SDRAM Access time from clock at CL =1.5
-
-
-
00h
27
Minimum row precharge time (=tRP)
20ns
20ns
18ns
50h
50h
48h
28
Minimum row activate to row active delay(=tRRD)
15ns
15ns
14ns
3Ch
3Ch
38h
V82658B04S Rev. 1.2 March 2002
10ns
±0.8ns
5
10ns
7.5ns
±0.8ns ±0.75ns
A0h
A0h
75h
80h
80h
75h
V82658B04S
MOSEL VITELIC
Serial Presence Detect Information (cont.)
Function Supported
Byte #
Function described
Hex value
A1
B0
B1
A1
B0
B1
29
Minimum RAS to CAS delay(=tRCD )
20ns
20ns
18ns
50h
50h
48h
30
Minimum active to precharge time(=tRAS)
50ns
45ns
45ns
32h
2Dh
2Dh
31
Module ROW density
32
Command and address signal input setup time
1.1ns
0.9ns
0.9ns
B0h
90h
90h
33
Command and address signal input hold time
1.1ns
0.9ns
0.9ns
B0h
90h
90h
34
Data signal input setup time
0.6ns
0.5ns
0.5ns
60h
50h
50h
35
Data signal input hold time
0.6ns
0.5ns
0.5ns
60h
50h
50h
36-40
64MB
Superset information (may be used in future)
10h
-
00h
41
SDRAM device minimum active to active/auto-refresh time
(=tRC )
70ns
65ns
60ns
46h
41h
3Ch
42
SDRAM device minimum active to autorefresh to active/auto-refresh
time (=tRFC)
80ns
75ns
67ns
50h
4Bh
43h
43
SDRAM device maximum device cycle time (=tCK MAX)
12ns
12ns
12ns
30h
30h
30h
44
SDRAM device maximum skew between DQS and DQ signals
(=tDQSQ)
0.6ns
0.5ns
0.5ns
3Ch
32h
32h
45
SDRAM device maximum read datahold skew factor (=tQHS)
1ns
0.75ns
0.75ns
A0h
75h
75h
46-61
Superset information (may be used in future)
-
00h
Initial release
00h
62
SPD data revision code
63
Checksum for Bytes 0 ~ 62
64
Manufacturer JEDEC ID code
Mosel Vitelic
40h
....... Manufacturer JEDEC ID code
Mosel Vitelic
00h
65 -71
72
73-90
-
Manufacturing location
BBh
01h
01h
Module part number (ASCII)
V82658B04S
91
Manufacturer revison code (For PCB)
0
00
92
Manufacturer revison code (For component)
0
00
93
Manufacturing date (Week)
-
-
94
Manufacturing date (Year)
-
-
Assembly serial #
-
-
99~127 Manufacturer specific data (may be used in future)
Undefined
00h
128~255 Open for customer use
Undefined
00h
95~98
V82658B04S Rev. 1.2 March 2002
6
A0h
V82658B04S
MOSEL VITELIC
DC Operating Conditions
(TA = 0 to 70°C, Voltage referenced to VSS = 0V)
Parameter
Symbol
Min
Typ.
Max
Unit
Power Supply Voltage
VDD
2.3
2.5
2.7
V
Power Supply Voltage
VDDQ
2.3
2.5
2.7
V
Input High Voltage
VIH
VREF + 0.15
-
VDDQ + 0.3
V
Input Low Voltage
VIL
-0.3
-
VREF - 0.15
V
I/O Termination Voltage
VTT
VREF - 0.04
VREF
VREF + 0.04
V
VREF
1.15
1.25
1.35
V
II
-2
-
2
µA
Output Leakage Current
IOz
-5
-
5
µA
Output High Current (VOUT = 1.95V)
IOH
-16.8
-
-
mA
Output Low Current (VOUT = 0.35V)
IOL
16.8
-
-
mA
Reference Voltage
Input Leakage Current
Note
1
2
3
Notes: 1. VDDQ must not exceed the level of VDD .
2. VIL (min) is acceptable -1.5V AC pulse width with ð 5ns of duration.
3. The value of VREF is approximately equal to 0.5VDDQ.
AC Operating Conditions
(TA = 0 to 70 °C, Voltage referenced to VSS = 0V)
Parameter
Symbol
Min
Input High (Logic 1) Voltage, DQ, DQS and DM signals
VIH(AC)
VREF + 0.31
Input Low (Logic 0) Voltage, DQ, DQS and DM signals
VIL(AC)
Input Differential Voltage, CK and CK inputs
VID(AC)
Input Crossing Point Voltage, CK and CK inputs
VIX(AC)
Max
Unit
Note
V
VREF - 0.31
V
0.7
VDDQ + 0.6
V
1
0.5*VDDQ-0.2
0.5*VDDQ+0.2
V
2
Notes: 1. VID is the magnitude of the difference between the input level on CK and the input on CK.
2. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the DC level of the
same.
V82658B04S Rev. 1.2 March 2002
7
V82658B04S
MOSEL VITELIC
AC Operating Test Conditions (TA = 0 to 70°C, Voltage referenced to VSS = 0V)
Parameter
Value
Unit
Reference Voltage
VDDQ x 0.5
V
Termination Voltage
VDDQ x 0.5
V
AC Input High Level Voltage (VIH, min)
VREF + 0.31
V
AC Input Low Level Voltage (VIL, max)
VREF - 0.31
V
VREF
V
Output Timing Measurement Reference Level Voltage
VTT
V
Input Signal maximum peak swing
1.5
V
Input minimum Signal Slew Rate
1
V/ns
Termination Resistor (RT)
50
¾
Series Resistor (R S)
25
¾
Output Load Capacitance for Access Time Measurement (C L)
30
pF
Input Timing Measurement Reference Level Voltage
Vtt=0.5*VDDQ
RT=50Ω
Output
Z0=50Ω
CLOAD=30pF
VREF
=0.5*V DDQ
Output Load Circuit (SSTL_2)
Input/Output Capacitance
(VDD = 2.5V, VDDQ = 2.5V, TA = 25°C, f = 1MHz)
Parameter
Symbol
Min
Max
Unit
Input capacitance (A0 ~ A11, BA0 ~ BA1, RAS, CAS, WE)
CIN1
36
45
pF
Input capacitance (CKE0)
CIN2
36
45
pF
Input capacitance (CS0)
CIN3
34
42
pF
Input capacitance (CLK1, CLK2)
CIN4
34
38
pF
Data & DQS input/output capacitance (DQ 0~DQ63)
COUT
8
9
pF
Input capacitance (DM0~DM8)
CIN5
8
9
pF
V82658B04S Rev. 1.2 March 2002
8
V82658B04S
MOSEL VITELIC
DDR SDRAM IDD SPEC TABLE
B1(DDR266@CL=2)
B0(DDR266@CL=2.5)
A1(DDR200@CL=2)
Typical
Worst
Typical
Worst
Typical
Worst
IDD0
410
470
410
470
370
410
mA
IDD1
510
590
510
590
470
550
mA
IDD2P
110
130
110
130
90
110
mA
IDD2F
210
250
210
250
190
210
mA
IDD2Q
170
190
170
190
150
170
mA
IDD3P
150
170
150
170
130
150
mA
IDD3N
230
270
230
270
190
230
mA
IDD4R
730
850
730
850
610
750
mA
IDD4W
770
910
770
910
650
810
mA
IDD5
770
870
770
870
730
810
mA
Normal
8
8
8
8
8
8
mA
Low power
4
4
4
4
4
4
mA
1390
1610
1390
1610
1130
1330
mA
Symbol
IDD6
Unit
IDD7A
Notes
Optional
* Module IDD was calculated on the basis of component IDD and can be differently measured according to DQ loading cap.
Detailed test conditions for DDR SDRAM IDD1 & IDD
IDD1 : Operating current: One bank operation
1. Typical Case : Vdd = 2.5V, T=25’ C
2. Worst Case : Vdd = 2.7V, T= 10’ C
3. Only one bank is accessed with tRC(min), Burst Mode, Address and Control inputs on NOP edge are changing once
per clock cycle. lout = 0mA
4. Timing patterns
- DDR200(100Mhz, CL=2) : tCK = 10ns, CL2, BL=4, tRCD = 2*tCK, tRAS = 5*tCK
Read : A0 N R0 N N P0 N A0 N - repeat the same timing with random address changing
*50% of data changing at every burst
- DDR266B(133Mhz, CL=2.5) : tCK = 7.5ns, CL=2.5, BL=4, tRCD = 3*tCK, tRC = 9*tCK, tRAS = 5*tCK
Read : A0 N N R0 N P0 N N N A0 N - repeat the same timing with random address changing
*50% of data changing at every burst
- DDR266A (133Mhz, CL=2) : tCK = 7.5ns, CL=2, BL=4, tRCD = 3*tCK, tRC = 9*tCK, tRAS = 5*tCK
Read : A0 N N R0 N P0 N N N A0 N - repeat the same timing with random address changing
*50% of data changing at every burst
Legend : A=Activate, R=Read, W=Write, P=Precharge, N=NOP
V82658B04S Rev. 1.2 March 2002
9
V82658B04S
MOSEL VITELIC
AC Characteristics (AC operating conditions unless otherwise noted)
(PC1600)
Parameter
(PC2100A)
Min
Max
Min
Max
Unit
Symbol
Min
Row Cycle Time
tRC
60
-
65
-
70
-
ns
Auto Refresh Row Cycle Time
tRFC
67
-
75
-
80
-
ns
Row Active Time
tRAS
45
120K
48
120K
50
120K
ns
Row Address to Column Address Delay
tRCD
18
-
20
-
20
-
ns
Row Active to Row Active Delay
tRRD
14
-
15
-
15
-
ns
Column Address to Column Address Delay
tCCD
1
-
1
-
1
-
CLK
Row Precharge Time
tRP
18
-
20
-
20
-
ns
Write Recovery Time
tWR
15
-
15
-
15
-
ns
Last Data-In to Read Command
tDRL
1
-
1
-
1
-
CLK
Auto Precharge Write Recovery + Precharge Time
tDAL
35
-
35
-
35
-
ns
System Clock Cycle Time
tCK
7
12
7.5
12
8
12
ns
7.5
12
10
12
10
12
ns
CAS Latency = 2.5
CAS Latency = 2
Max
(PC2100B)
Note
Clock High Level Width
tCH
0.45
0.55
0.45
0.55
0.45
0.55
CLK
Clock Low Level Width
tCL
0.45
0.55
0.45
0.55
0.45
0.55
CLK
Data-Out edge to Clock edge Skew
tAC
-0.75
0.75
-0.75
0.75
-0.8
0.8
ns
DQS-Out edge to Clock edge Skew
tDQSCK
-0.75
0.75
-0.75
0.75
-0.8
0.8
ns
DQS-Out edge to Data-Out edge Skew
tDQSQ
-
0.5
-
0.5
-
0.6
ns
Data-Out hold time from DQS
tQH
tHPmin
-0.75ns
-
tHPmin
-0.75ns
-
tHPmin
-0.75ns
-
ns
1
Clock Half Period
tHP
tCH/L
min
-
tCH/L
min
-
tCH/L
min
-
ns
1
Input Setup Time (fast slew rate)
tIS
0.9
-
0.9
-
1.1
-
ns
2,3,5,6
Input Hold Time (fast slew rate)
tIH
0.9
-
0.9
-
1.1
-
ns
2,3,5,6
Input Setup Time (slow slew rate)
tIS
1.0
-
1.0
-
1.1
-
ns
2,4,5,6
Input Hold Time (slow slew rate)
tIH
1.0
-
1.0
-
1.1
-
ns
2,4,5,6
tIPW
2.2
-
2.2
-
-
-
ns
6
Write DQS High Level Width
tDQSH
0.4
0.6
0.4
0.6
0.4
0.6
CLK
Write DQS Low Level Width
tDQSL
0.4
0.6
0.4
0.6
0.4
0.6
CLK
CLK to First Rising edge of DQS-In
tDQSS
0.75
1.25
0.75
1.25
0.75
1.25
CLK
Data-In Setup Time to DQS-In (DQ & DM)
tDS
0.5
-
0.5
-
0.6
-
ns
7
Data-in Hold Time to DQS-In (DQ & DM)
tDH
0.5
-
0.5
-
0.6
-
ns
7
DQ & DM Input Pulse Width
tDIPW
1.75
-
1.75
-
2
-
ns
Read DQS Preamble Time
tRPRE
0.9
1.1
0.9
1.1
0.9
1.1
CLK
Read DQS Postamble Time
tRPST
0.4
0.6
0.4
0.6
0.4
0.6
CLK
Input Pulse Width
V82658B04S Rev. 1.2 March 2002
10
V82658B04S
MOSEL VITELIC
AC Characteristics (cont.)
(PC1600)
Parameter
Max
(PC2100B)
(PC2100A)
Min
Max
Min
Max
Unit
Symbol
Min
Write DQS Preamble Setup Time
tWPRES
0
-
0
-
0
-
CLK
Write DQS Preamble Hold Time
tWPREH
0.25
-
0.25
-
0.25
-
CLK
Write DQS Postamble Time
tWPST
0.4
0.6
0.4
0.6
0.4
0.6
CLK
Mode Register Set Delay
tMRD
2
-
2
-
2
-
CLK
Power Down Exit Time
tPDEX
10
-
10
-
10
-
ns
Exit Self Refresh to Non-Read Command
tXSNR
75
-
75
-
80
-
ns
Exit Self Refresh to Read Command
tXSRD
200
-
200
-
200
-
CLK
Average Periodic Refresh Interval
tREFI
-
15.6
-
15.6
-
15.6
us
Note
8
Notes: 1. This calculation accounts for tDQSQ(max), the pulse width distortion of on-chip circuit and jitter.
2. Data sampled at the rising edges of the clock : A0~A11, BA0~BA1, CKE, CS, RAS, CAS, WE.
3. For command/address input slew rate >=1.0V/ns
4. For command/address input slew rate >=0.5V/ns and <1.0V/ns
5. CK, CK slew rates are >=1.0V/ns
6. These parameters guarantee device timing, but they are not necessarily tested on each device, and they may be guaranteed
by design or tester correlation.
7. Data latched at both rising and falling edges of Data Strobes(DQS) : DQ, DM
8. Minimum of 200 cycles of stable input clocks after Self Refresh Exit command, where CKE is held high, is required to complete
Self Refresh Exit and lock the internal DLL circuit of DDR SDRAM.
Absolute Maximum Ratings
Parameter
Symbol
Rating
Unit
Ambient Temperature
TA
0 ~ 70
°C
Storage Temperature
TSTG
-55 ~ 125
°C
VIN , V OUT
-0.5 ~ 3.6
V
VDD
-0.5 ~ 3.6
V
VDDQ
-0.5 ~ 3.6
V
Output Short Circuit Current
IOS
50
mA
Power Dissipation
PD
8
W
TSOLDER
260 • 10
°C • Sec
Voltage on Any Pin relative to VSS
Voltage on VDD relative to VSS
Voltage on VDDQ relative to V SS
Soldering Temperature • Time
Note: Operation at above absolute maximum rating can adversely affect device reliability
V82658B04S Rev. 1.2 March 2002
11
V82658B04S
MOSEL VITELIC
Package Dimensions
Units : Inches (Millimeters )
2.70
(67.60)
2.50
(63.60)
199
39 41
0.456
11.40
0.086
2.15
1.896
(47.40)
0.17
(4.20)
0.096
(2.40)
0.07
(1.8)
0.79
(20.00)
0.24
(6.0)
1
Z
1.25
(31.75)
F ull R 2x
0.16 0.039
(4.00 0.10)
2- 0.07
(1.80)
Y
0.098
2.45
200
0.157 Min
(4.00 Min)
0.095 Max
(2.40 Max)
0.04 0.0039
(1.00 0.10)
0.16 0.0039
(4.00 0.10)
0.04 0.0039
(1.00 0.1)
Detail Z
0.018
(0.45
12
0.001
0.03)
0.01
(0.25)
0.024 T Y P
(0.60 T Y P )
Detail Y
T olerances : .006(.15) unles s otherwis e s pecified
V82658B04S Rev. 1.2 March 2002
0.102 Min
40 42
(2.55 Min)
2
V82658B04S
MOSEL VITELIC
Label Information
Module Density
MOSEL VITELIC
Part Number
Criteria of PC2100 or PC1600
DIMM manufacture date code
V82658B04SXXX-XX 64MB CLXX
PC2100U-2533-080-A
XXXX-XXXXXXX
Assembly in Taiwan
PC2100 U - 2533 - 08 0 - A
UNBUFFERED DIMM
Gerber file JEDEC
CL = 2.5 (CLK)
tRCD = 3 (CLK)
tRP = 3 (CLK)
V82658B04S Rev. 1.2 March 2002
SPD Revision 0
13
CAS Latency
V82658B04S
MOSEL VITELIC
WORLDWIDE OFFICES
U.S.A.
TAIWAN
SINGAPORE
UK & IRELAND
3910 NORTH FIRST STREET
SAN JOSE, CA 95134
PHONE: 408-433-6000
FAX: 408-433-0952
7F, NO. 102
MIN-CHUAN E. ROAD, SEC. 3
TAIPEI
PHONE: 886-2-2545-1213
FAX: 886-2-2545-1209
10 ANSON ROAD #23-13
INTERNATIONAL PLAZA
SINGAPORE 079903
PHONE: 65-3231801
FAX: 65-3237013
NO 19 LI HSIN ROAD
SCIENCE BASED IND. PARK
HSIN CHU, TAIWAN, R.O.C.
PHONE: 886-3-579-5888
FAX: 886-3-566-5888
JAPAN
SUITE 50, GROVEWOOD
BUSINESS CENTRE
STRATHCLYDE BUSINESS
PARK
BELLSHILL, LANARKSHIRE,
SCOTLAND, ML4 3NQ
PHONE: 44-1698-748515
FAX: 44-1698-748516
ONZE 1852 BUILDING 6F
2-14-6 SHINTOMI, CHUO-KU
TOKYO 104-0041
PHONE: 03-3537-1400
FAX: 03-3537-1402
GERMANY
(CONTINENTAL
EUROPE & ISRAEL)
BENZSTRASSE 32
71083 HERRENBERG
GERMANY
PHONE: +49 7032 2796-0
FAX: +49 7032 2796 22
U.S. SALES OFFICES
WEST
CENTRAL / EAST
3910 NORTH FIRST STREET
SAN JOSE, CA 95134
PHONE: 408-433-6000
FAX: 408-433-0952
604 FIELDWOOD CIRCLE
RICHARDSON, TX 75081
PHONE: 214-352-3775
FAX: 214-904-9029
© Copyright , MOSEL VITELIC Corp.
Printed in U.S.A.
MOSEL VITELIC subjects its products to normal quality control
sampling techniques which are intended to provide an assurance
of high quality products suitable for usual commercial applications. MOSEL VITELIC does not do testing appropriate to provide
100% product quality assurance and does not assume any liability for consequential or incidental arising from any use of its products. If such products are to be used in applications in which
personal injury might occur from failure, purchaser must do its
own quality assurance testing appropriate to such applications.
The information in this document is subject to change without
notice.
MOSEL VITELIC makes no commitment to update or keep current the information contained in this document. No part of this
document may be copied or reproduced in any form or by any
means without the prior written consent of MOSEL-VITELIC.
V82658B04S Rev. 1.2 March 2002
14