ICX059AK 1/3-inch CCD Image Sensor for PAL Color Camera For the availability of this product, please contact the sales office. Description The ICX059AK is an interline CCD solid-state image sensor suitable for PAL color video cameras. High resolution is achieved through the use of Ye, Cy, Mg, and G complementary color mosaic filters. At the same time, high sensitivity and low dark current are achieved through the adoption of HAD (HoleAccumulation Diode) sensors. This chip features a field period readout system and an electronic shutter with variable charge-storage time. Features • High resolution, high sensitivity and low dark current • Continuous variable-speed shutter 1/50s (Typ.), 1/120s to 1/10000s • Low smear • Excellent antiblooming characteristics • Ye, Cy, Mg, and G complementary color mosaic filters on chip • Horizontal register: 5V drive • Reset gate: 5V drive 16 pin DIP (Plastic) AAAAA AAAAA AAAAA AAAAA Pin 1 V 3 Pin 9 Device Structure • Optical size: • Number of effective pixels: • Number of total pixels: • Interline CCD image sensor • Chip size: • Unit cell size: • Optical black: • Number of dummy bits: • Substrate material: 1/3-inch format 752 (H) × 582 (V) approx. 440K pixels 795 (H) × 596 (V) approx. 470K pixels H 2 12 40 Optical black position (Top View) 6.00mm (H) × 4.96mm (V) 6.50µm (H) × 6.25µm (V) Horizontal (H) direction: Front 3 pixels, rear 40 pixels Vertical (V) direction: Front 12 pixels, rear 2 pixels Horizontal 22 Vertical 1 (even field only) Silicon Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits. –1– E91Y29B5Y-PS ICX059AK VOUT VSS VGG GND Vφ1 Vφ2 Vφ3 Vφ4 Block Diagram and Pin Configuration (Top View) 8 7 6 5 4 3 2 1 Vertical register Cy Ye Ye Cy Mg G Mg G Cy Ye Cy Ye G Mg G Mg Cy Ye Cy Ye Mg G Mg G Note) Horizontal register Pin No. Symbol SUB VL Description 14 15 16 Hφ2 GND Pin Description 13 Hφ1 12 LHφ1 11 RG 10 VDD Note) 9 Pin No. Symbol :Photo sensor Description 1 Vφ4 Vertical register transfer clock 9 VDD Output amplifier drain supply 2 Vφ3 Vertical register transfer clock 10 GND GND 3 Vφ2 Vertical register transfer clock 11 SUB Substrate (Overflow drain) 4 Vφ1 Vertical register transfer clock 12 VL Protective transistor bias 5 GND GND 13 RG Reset gate clock 6 VGG Output amplifier gate bias 14 LHφ1 Horizontal register final stage transfer clock 7 VSS Output amplifier source 15 Hφ1 Horizontal register transfer clock 8 VOUT Signal output 16 Hφ2 Horizontal register transfer clock Absolute Maximum Ratings Item Ratings Unit –0.3 to +55 V VDD, VOUT, VSS – GND –0.3 to +18 V VDD, VOUT, VSS – SUB –55 to +10 V Vφ1, Vφ2, Vφ3, Vφ4 – GND –15 to +20 V Vφ1, Vφ2, Vφ3, Vφ4 – SUB to +10 V Voltage difference between vertical clock input pins to +15 V Voltage difference between horizontal clock input pins to +17 V Hφ1, Hφ2 – Vφ4 –17 to +17 V Hφ1, Hφ2, LHφ1, RG, VGG – GND –10 to +15 V Hφ1, Hφ2, LHφ1, RG, VGG – SUB –55 to +10 V VL – SUB –65 to +0.3 V Vφ1, Vφ2, Vφ3, Vφ4, VDD, VOUT – VL –0.3 to +30 V RG – VL –0.3 to +24 V VGG, VSS, Hφ1, Hφ2, LHφ1 – VL –0.3 to +20 V Storage temperature –30 to +80 °C Operating temperature –10 to +60 °C Substrate voltage SUB – GND Supply voltage Vertical clock input voltage ∗1 +27V (Max.) when clock width < 10µs, clock duty factor < 0.1%. –2– Remarks ∗1 ICX059AK Bias Conditions Item Symbol Min. Typ. Max. Unit Output amplifier drain voltage VDD 14.55 15.0 15.45 V Output amplifier gate voltage VGG 3.8 4.2 4.65 V Output amplifier source VSS Substrate voltage adjustment range VSUB 9.0 18.5 V Fluctuation range after substrate voltage adjustment ∆VSUB –3 +3 % Reset gate clock voltage adjustment range VRGL 1.0 4.0 V Fluctuation range after reset gate clock voltage adjustment ∆VRGL –3 +3 % Protective transistor bias VL Remarks Grounded with 820Ω resistor ±5% ∗1 ∗1 ∗6 ∗2 DC Characteristics Item Symbol Min. Typ. Max. 5 Unit Remarks Output amplifier drain current IDD mA Input current IIN1 1 µA ∗3 Input current IIN2 10 µA ∗4 ∗1 Indications of substrate voltage (VSUB) · reset gate clock voltage (VRGL) setting value. The setting values of substrate voltage and reset gate clock voltage are indicated on the back of the image sensor by a special code. Adjust substrate voltage (VSUB) and reset gate clock voltage (VRGL) to the indicated voltage. Fluctuation range after adjustment is ±3%. VSUB code VRGL code one character indication one character indication ↑ ↑ VRGL code VSUB code Code and optimal setting correspond to each other as follows. VRGL code 1 2 3 4 5 6 7 Optimal setting 1.0 1.5 2.0 2.5 3.0 3.5 4.0 VSUB code E Optimal setting 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 18.0 18.5 f G h J K L m N P Q R S T U V W X Y Z <Example> “5L” → VRGL = 3.0V VSUB = 12.0V ∗2 VL setting is the VVL voltage of the vertical transfer clock waveform. ∗3 1) Current to each pin when 18V is applied to VDD, VOUT, Vss and SUB pins, while pins that are not tested are grounded. 2) Current to each pin when 20V is applied sequentially to Vφ1, Vφ2, Vφ3 and Vφ4 pins, while pins that are not tested are grounded. However, 20V is applied to SUB pin. 3) Current to each pin when 15V is applied sequentially to RG, LHφ1, Hφ1, Hφ2 and VGG pins, while pins that are not tested are grounded. However, 15V is applied to SUB pin. 4) Current to VL pin when 30V is applied to Vφ1, Vφ2, Vφ3, Vφ4, VDD and VOUT pins or when, 24V is applied to RG pin or when, 20V is applied to VGG, Vss, Hφ1, Hφ2 and LHφ1 pins, while VL pin is grounded. However, GND and SUB pins are left open. ∗4 Current to SUB pin when 55V is applied to SUB pin, while pins that are not tested are grounded. –3– ICX059AK Clock Voltage Conditions Item Readout clock voltage Vertical transfer clock voltage Min. Typ. Max. Unit Waveform diagram VVT 14.55 15.0 15.45 V 1 VVH1, VVH2 –0.05 0 0.05 V 2 VVH3, VVH4 –0.2 0 0.05 V 2 VVL1, VVL2, VVL3, VVL4 –9.0 –8.5 –8.0 V 2 VVL = (VVL3 + VVL4)/2 VφV 7.8 8.5 9.05 V 2 VφV = VVHn – VVLn (n = 1 to 4) 0.1 V 2 Symbol I VVH1 – VVH2 I Remarks VVH = (VVH1 + VVH2)/2 VVH3 – VVH –0.25 0.1 V 2 VVH4 – VVH –0.25 0.1 V 2 VVHH 0.5 V 2 High-level coupling VVHL 0.5 V 2 High-level coupling VVLH 0.5 V 2 Low-level coupling VVLL 0.5 V 2 Horizontal transfer clock voltage VφH, VφLH 4.75 5.0 5.25 V 3 Low-level coupling ∗5 VHL, VLHL –0.05 0 0.05 V 3 ∗5 Reset gate clock voltage VφRG 4.5 5.0 5.5 V 4 ∗6 0.8 V 4 Low-level coupling 24.5 V 5 VRGLH – VRGLL Substrate clock voltage VφSUB 22.5 23.5 ∗5 The horizontal final stage transfer clock input pin LHφ1 is connected to the horizontal transfer clock input pin Hφ1. ∗6 The reset gate clock voltage need not be adjusted when reset gate clock is driven when the specifications are as given below. In this case, the reset gate clock voltage setting indicated on the back of the image sensor has not significance. Item Reset gate clock voltage Min. Typ. Max. Unit Waveform diagram VRGL –0.2 0 0.2 V 4 VφRG 8.5 9.0 9.5 V 4 Symbol –4– Remarks ICX059AK Clock Equivalent Circuit Constant Item Symbol Min. Typ. Max. Unit CφV1, CφV3 1000 pF CφV2, CφV4 560 pF CφV12, CφV34 470 pF CφV23, CφV41 390 pF CφV13 180 pF CφV24 100 pF Capacitance between horizontal transfer clock and GND CφH1, CφH2 47 pF Capacitance between horizontal transfer clocks CφHH 51 pF Capacitance between horizontal final stage transfer clock and GND CφLH 8 pF Capacitance between reset gate clock and GND CφRG 8 pF Capacitance between substrate clock and GND CφSUB 270 pF Vertical transfer clock series resistor R1, R2, R3, R4 80 Ω Vertical transfer clock ground resistor RGND 15 Ω Horizontal transfer clock series resistor RφH 15 Ω Capacitance between vertical transfer clock and GND Capacitance between vertical transfer clocks Vφ1 Remarks Vφ2 CφV12 R1 R2 RφH RφH Hφ2 Hφ1 CφV1 CφHH CφV2 CφV41 CφV23 CφH1 CφH2 CφV13 CφV24 CφV4 RGND CφV3 R4 Vφ4 CφV34 R3 Vφ3 Vertical transfer clock equivalent circuit Horizontal transfer clock equivalent circuit –5– ICX059AK Drive Clock Waveform Conditions (1) Readout clock waveform 100% 90% II II φM VVT φM 2 10% 0% tr twh 0V tf (2) Vertical transfer clock waveform Vφ1 Vφ3 VVHH VVH1 VVHH VVH VVHL VVHL VVH3 VVHL VVL1 VVH VVHH VVHH VVHL VVL3 VVLH VVLH VVLL VVLL VVL VVL Vφ2 Vφ4 VVHH VVHH VVH VVH VVHH VVHH VVHL VVH2 VVHL VVHL VVH4 VVL2 VVHL VVLH VVLH VVLL VVLL VVL VVL4 VVH = (VVH1 + VVH2)/2 VVL = (VVL3 + VVL4)/2 VφV = VVHn – VVLn (n = 1 to 4) –6– VVL ICX059AK (3) Horizontal transfer clock waveform tr twh tf 90% twl VφH 10% VHL (4) Reset gate clock waveform tr twh tf VRGH twl Point A VφRG RG waveform VRGL + 0.5V VRGLH VRGL VRGLL LHφ1 waveform 2.5V VRGLH is the maximum value and VRGLL is the minimum value of the coupling waveform during the period from Point A in the above diagram until the rising edge of RG. In addition, VRGL is the average value of VRGLH and VRGLL. VRGL = (VRGLH + VRGLL)/2 Assuming VRGH is the minimum value during the interval twh, then: VφRG = VRGH – VRGL –7– ICX059AK (5) Substrate clock waveform 100% 90% φM VφSUB 10% 0% VSUB tr twh φM 2 tf Clock Switching Characteristics Note) Because the horizontal final stage transfer clock LHφ1 is connected to the horizontal transfer clock Hφ1, specifications will be the same as Hφ1. Item twh Symbol twl tr tf Unit Remarks Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. VT Vertical transfer clock Vφ1, Vφ2, Vφ3, Vφ4 Horizontal transfer clock Readout clock During imaging 2.3 2.5 0.5 0.5 18 24 Hφ2 21 26 During Hφ1, LHφ1 parallel-serial Hφ2 conversion 10 17.5 19.5 26 19 24 10 6.41 Reset gate clock φRG 11 Substrate clock φSUB 1.5 1.8 13 15 During readout 250 ns ∗1 15 Hφ1, LHφ1 µs 10 17.5 10 0.01 0.01 6.41 0.01 0.01 51 3 3 0.5 15 ns ∗2 µs ns 0.5 µs During drain charge ∗1 When vertical transfer clock driver CXD1250 is used. ∗2 tf ≥ tr – 2ns, and the cross-point voltage (VCR) for the Hφ1 · LHφ1 rising side of the Hφ1 · LHφ1 and Hφ2 waveforms must be at least 2.5V. Item Horizontal transfer clock Symbol Hφ1 · LHφ1, Hφ2 two Min. Typ. 16 20 Max. Unit Remarks ns ∗3 ∗3 The overlap period for twh and twl of horizontal transfer clocks Hφ1 · LHφ1 and Hφ2 is two. –8– ICX059AK Image Sensor Characteristics Item (Ta = 25°C) Symbol Min. Typ. Sensitivity S 260 330 Saturation signal Ysat 540 Smear Sm Video signal shading SHy Unit Measurement method mV 1 mV 2 % 3 20 % 4 Zone 0, I 25 % 4 Zone 0 to II' ∆Sr 10 % 5 ∆Sb 10 % 5 Dark signal Ydt 2 mV 6 Ta = 60°C Dark signal shading ∆Ydt 1 mV 7 Ta = 60°C Flicker Y Fy 2 % 8 Flicker R-Y Fcr 5 % 8 Flicker B-Y Fcb 5 % 8 Line crawl R Lcr 3 % 9 Line crawl G Lcg 3 % 9 Line crawl B Lcb 3 % 9 Line crawl W Lcw 3 % 9 Lag Lag 0.5 % 10 Uniformity between video signal channels Max. 0.009 0.015 Remarks Ta = 60°C Zone Definition of Video Signal Shading 752 (H) 12 12 8 V 10 H 8 H 8 Zone 0, I Zone II, II' 582 (V) 6 Ignored region Effective pixel region V 10 Measurement System [∗Y] [∗A] CCD signal output Y signal output LPF1 (3dB down 6.3MHz) CCD C.D.S AMP [∗C] S/H LPF2 S/H Chroma signal output (3dB down 1MHz) Note) Adjust the amplifier gain so that the gain between [∗A] and [∗Y] and between [∗A] and [∗C] equal 1. –9– ICX059AK Image Sensor Characteristics Measurement Method Measurement conditions 1) In the following measurements, the substrate voltage and the reset gate clock voltage are set to the values indicated on the device, and the device drive conditions are at the typical values of the bias and clock voltage conditions. 2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical black level (OB) is used as the reference for the signal output, which is taken as the value of Y signal output or chroma signal output of the measurement system. Color coding of this image sensor & Composition of luminance (Y) and chroma (color difference) signals Cy Ye Cy Ye A1 G Mg G Mg Cy Ye Cy Ye Mg G Mg G B A2 As shown in the left figure, fields are read out. The charge is mixed by pairs such as A1 and A2 in the A field. (pairs such as B in the B field) As a result, the sequence of charges output as signals from the horizontal shift register (Hreg) is, for line A1, (G + Cy), (Mg + Ye), (G + Cy), and (Mg + Ye). Hreg Color Coding Diagram These signals are processed to form the Y signal and chroma (color difference) signal. The Y signal is formed by adding adjacent signals, and the chroma signal is formed by subtracting adjacent signals. In other words, the approximation: Y = {(G + Cy) + (Mg + Ye)} × 1/2 = 1/2 {2B + 3G + 2R} is used for the Y signal, and the approximation: R – Y = {(Mg + Ye) – (G + Cy)} = {2R – G} is used for the chroma (color difference) signal. For line A2, the signals output from Hreg in sequence are (Mg + Cy), (G + Ye), (Mg + Cy), (G + Ye). The Y signal is formed from these signals as follows: Y = {(G + Ye) + (Mg + Cy)} × 1/2 = 1/2 {2B + 3G + 2R} This is balanced since it is formed in the same way as for line A1. In a like manner, the chroma (color difference) signal is approximated as follows: – (B – Y) = {(G + Ye) – (Mg + Cy)} = – {2B – G} In other words, the chroma signal can be retrieved according to the sequence of lines from R – Y and – (B – Y) in alternation. This is also true for the B field. – 10 – ICX059AK Definition of standard imaging conditions 1) Standard imaging condition I: Use a pattern box (luminance 706cd/m2, color temperature of 3200K halogen source) as a subject. (Pattern for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter and image at F5.6. The luminous intensity to the sensor receiving surface at this point is defined as the standard sensitivity testing luminous intensity. 2) Standard imaging condition II: Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles. Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted to the value indicated in each testing item by the lens diaphragm. 1. Sensitivity Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of 1/250s, measure the Y signal (Ys) at the center of the screen and substitute the value into the following formula. S = Ys × 250 [mV] 50 2. Saturation signal Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity with average value of the Y signal output, 200mV, measure the minimum value of the Y signal. 3. Smear Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to 500 times the intensity with average value of the Y signal output, 200mV. When the readout clock is stopped and the charge drain is executed by the electronic shutter at the respective H blankings, measure the maximum value YSm [mV] of the Y signal output and substitute the value into the following formula. Sm = 1 YSm 1 × × × 100 [%] (1/10V method conversion value) 10 200 500 4. Video signal shading Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity so that the average value of the Y signal output is 200mV. Then measure the maximum (Ymax [mV]) and minimum (Ymin [mV]) values of the Y signal and substitute the values into the following formula. SHy = (Ymax – Ymin)/200 × 100 [%] 5. Uniformity between video signal channels Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then measure the maximum (Crmax, Cbmax [mV]) and minimum (Crmin, Cbmin [mV]) values of the R – Y and B – Y channels of the chroma signal and substitute the values into the following formula. ∆Sr = | (Crmax – Crmin)/200 | × 100 [%] ∆Sb = | (Cbmax – Cbmin)/200 | × 100 [%] 6. Dark signal Measure the average value of the Y signal output (Ydt [mV]) with the device ambient temperature 60°C and the device in the light-obstructed state, using the horizontal idle transfer level as a reference. – 11 – ICX059AK 7. Dark signal shading After measuring 6, measure the maximum (Ydmax [mV]) and minimum (Ydmin [mV]) values of the Y signal output and substitute the values into the following formula. ∆Ydt = Ydmax – Ydmin [mV] 8. Flicker 1) Fy Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then measure the difference in the signal level between fields (∆Yf [mV]). Then substitute the value into the following formula. Fy = (∆Yf/200) × 100 [%] 2) Fcr, Fcb Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, insert an R or B filter, and then measure both the difference in the signal level between fields of the chroma signal (∆Cr, ∆Cb) as well as the average value of the chroma signal output (CAr, CAb). Substitute the values into the following formula. Fci = (∆Ci/CAi) × 100 [%] (i = r, b) 9. Line crawls Set to standard imaging condition II. Adjust the luminous intensity so that the average value of the Y signal output is 200mV, and then insert a white subject and R, G, and B filters and measure the difference between Y signal lines for the same field (∆Ylw, ∆Ylr, ∆Ylg, ∆Ylb [mV]). Substitute the values into the following formula. Lci = (∆Yli/200) × 100 [%] (i = w, r, g, b) 10. Lag Adjust the Y signal output value generated by strobe light to 200mV. After setting the strobe light so that it strobes with the following timing, measure the residual signal (Ylag). Substitute the value into the following formula. Lag = (Ylag/200) × 100 [%] FLD SG1 Light Strobe light timing Y signal output 200mV Output – 12 – Ylag (lag) RG Hφ1 Hφ2 XV4 XSG2 XV3 XSG1 XV1 XV2 XSUB 22 /10V 10 9 8 7 50k 1/20V 100k 11 12 13 14 15 16 5 CXD1250 17 4 6 19 18 2 3 22/20V 22/16V 10/20V 1/35V 0.01 1/35V 1/35V 1 2 3 27k 0.1 1/6.3V ICX059 (BOTTOM VIEW) 16 15 14 13 12 11 10 9 0.01 2SK523 3.9k 100 3.3/16V 15k 0.1 15k 47k 47/6.3V 3.3/20V 820 39k 270k 2SC2785 × 3 6 7 8 39k 100k 4 5 100k 56k Vφ3 Hφ1 20 Vφ2 LHφ1 1 GND VL 5V 0.1 Vφ1 RG VOUT 15V VGG SUB Vφ4 Hφ2 VSS GND – 13 – VDD Drive Circuit 1M CCD OUT [∗A] –8.5V ICX059AK ICX059AK Spectral Sensitivity Characteristics (Includes lens characteristics, excludes light source characteristics) 1.0 Ye 0.9 0.8 Cy G Relative Response 0.7 0.6 0.5 0.4 Mg 0.3 0.2 0.1 0.0 400 450 550 500 650 600 700 Wave Length [nm] Sensor Readout Clock Timing Chart HD V1 2.5 V2 Odd Field V3 V4 1.6 41.6 V1 2.5 2.5 2.5 0.2 V2 Even Field V3 V4 Unit : µs – 14 – – 15 – CLP1 CCD OUT V4 V3 V2 V1 SG2 SG1 HD BLK VD FLD 581 582 625 1 2 3 4 5 620 Drive Timing Chart (Vertical Sync) 15 2 4 6 1 3 5 20 2 4 6 1 3 5 315 582 581 13 5 24 6 335 1 3 5 2 46 ICX059AK 340 330 325 320 310 25 10 – 16 – SUB CLP1 V4 V3 V2 V1 SHD SHP RG H2 H1/LH1 BLK HD 20 10 750 752 1 3 5 745 Drive Timing Chart (Horizontal Sync) ICX059AK 20 10 20 22 1 2 3 1 2 3 10 1 2 3 5 40 30 ICX059AK Notes on Handling 1) Static charge prevention CCD image sensors are easily damaged by static discharge. Before handling be sure to take the following protective measures. a) Either handle bare handed or use non-chargeable gloves, clothes or material. Also use conductive shoes. b) When handling directly use an earth band. c) Install a conductive mat on the floor or working table to prevent the generation of static electricity. d) Ionized air is recommended for discharge when handling CCD image sensor. e) For the shipment of mounted substrates, use boxes treated for the prevention of static charges. 2) Soldering a) Make sure the package temperature does not exceed 80°C. b) Solder dipping in a mounting furnace causes damage to the glass and other defects. Use a ground 30W soldering iron and solder each pin in less than 2 seconds. For repairs and remount, cool sufficiently. c) To dismount an image sensor, do not use a solder suction equipment. When using an electric desoldering tool, use a thermal controller of the zero cross On/Off type and connect it to ground. 3) Dust and dirt protection a) Operate in clean environments (around class 1000 is appropriate). b) Do not either touch glass plates by hand or have any object come in contact with glass surfaces. Should dirt stick to a glass surface, blow it off with an air blower. (For dirt stuck through static electricity ionized air is recommended.) c) Clean with a cotton bud and ethyl alcohol if the grease stained. Be careful not to scratch the glass. d) Keep in a case to protect from dust and dirt. To prevent dew condensation, preheat or precool when moving to a room with great temperature differences. e) When a protective tape is applied before shipping, just before use remove the tape applied for electrostatic protection. Do not reuse the tape. 4) Do not expose to strong light (sun rays) for long periods, color filters will be discolored. 5) Exposure to high temperature or humidity will affect the characteristics. Accordingly avoid storage or usage in such conditions. 6) CCD image sensors are precise optical equipment that should not be subject to mechanical shocks. – 17 – – 18 – 1.2 2.5 0.69 ~ ~ Plastic GOLD PLATING 42 ALLOY 0.9g LEAD TREATMENT LEAD MATERIAL PACKAGE WEIGHT 0.3 M 1.27 9.2 10.3 12.2 ± 0.1 H PACKAGE MATERIAL V 6.1 ~ 2.5 0.46 0.3 A 1.2 2.5 8.4 (For the first pin only) 0.5 PACKAGE STRUCTURE B 5.7 D B' C 1 8 11.6 16 9 2.5 2-R0.5 9. The notches on the bottom of the package are used only for directional index, they must not be used for reference of fixing. 8. The thickness of the cover glass is 0.75mm, and the refractive index is 1.5. 7. The tilt of the effective image area relative to the bottom “C” is less than 50µm. The tilt of the effective image area relative to the top “D” of the cover glass is less than 50µm. 6. The height from the bottom “C” to the effective image area is 1.41 ± 0.10mm. The height from the top of the cover glass “D” to the effective image area is 1.94 ± 0.15mm. 5. The rotation angle of the effective image area relative to H and V is ± 1°. 4. The center of the effective image area relative to “B” and “B'” is (H, V) = (6.1, 5.7) ± 0.15mm. 3. The bottom “C” of the package, and the top of the cover glass “D” are the height reference. 2. The two points “B” of the package are the horizontal reference. The point “B'” of the package is the vertical reference. 1. “A” is the center of the effective image area. 16pin DIP (450mil) 9.5 11.4 ± 0.1 3.1 Unit: mm 3.35 ± 0.15 1.27 3.5 ± 0.3 0° to 9° 0.25 11.43 Package Outline ICX059AK