ASTEC LCT43-E

47 Watts
LCT43-E Series
Total Power: 47 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Triple
Electrical Specs
Input
Input range
85-264 VAC
120-300 VDC
47-63 Hz
<20 A peak @ 115 VAC;
<40 A peak @ 230 VAC,
cold start @ 25°C
1 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and
radiated
EN55022 Class B conducted and
radiated
Bellcore GR-1089-core Class B
conducted
Frequency
Inrush current
Input current
Efficiency
EMI filter
Special Features
•
•
•
•
•
•
•
Totally enclosed
Universal input
Quick Installation
Built-in EMI filter
Low output ripple
Overvoltage protection
Overload protection
Safety ground leakage
current
Output
Maximum power
Cross regulation
Hold-up time
Overload protection
Environmental
Operating temperature: 0° to 50°C ambient;
derate each output at 2.5% per degree from
50° to 70°C
Overvoltage protection
Electromagnetic susceptibility: designed to meet
IEC 1000-4, -2, -3, -4, -5, -6, 8, 11 Level 3
Humidity: Operating; non-condensing
5% to 90%
Vibration: .41 G from 3 to 500 Hz
Spectral break points of .0065 G2/Hz at 10 Hz and
200 Hz and 5 db/octave roll off at each end, 2
hours per axis
<3.5 mA @ 50/60 Hz, 264 VAC input
47 W with 12 CFM forced air
±2% on output 1;
±5% on outputs 2, 3
10 ms @ 47 W load, 100 VAC input
Short circuit protection on all
outputs.
Case overload protected @ 110135% above peak rating
5.50-6.75 VDC on main output
Safety
VDE
UL
CSA
CB
CE
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 -950-95-M90
Certificate and report
Mark (LVD)
21310-3336-0003
E186249
6593
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >300,000 hrs @ full load and
25°C ambient conditions
rev 8.11.04
90
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44(1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
12 CFM Forced Air
Peak
Load1
Regulation2
Ripple
P/P (PARD)3
LCT43-E
+5 V
+12 V
-12 V
1.0 A
0.1 A
0A
4A
1A
0.5 A
7A
1.2 A
0.5 A
8A
1.5 A
0.6 A
+4 / -2%
±5%
±5%
50 mV
120 mV
120 mV
1.
2.
3.
4.
LCT43-E Series
Ordering Information
Peak current lasting <30 seconds with a maximum 10% duty cycle.
At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Minimum Loads are required.
Pin Assignments
Connector
LCT43-E
SK1-1
SK1-2
SK1-3
AC Line
Ground
AC Neutral
SK2-1
SK2-2
SK2-3
SK2-4
SK2-5
SK2-6
-12 V
Com
+5 V
+5 V
Com
+12 V
Mating Connectors
AC Input:
IEC 320
DC Outputs: Molex 15-48-0406 (USA)
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Specifications are for convection rating at factory settings at 115
VAC input,
25°C unless otherwise stated.
4. Warranty: 1 year
5. Weight: 1.25 lb. / 0.57 kg
www.astecpower.com
91