Embedded Power for Business-Critical Continuity Rev.7.8.09_140 TLP150 Medical Series of 4 TLP150 Medical Series Single output Total Power: 150 W Input Voltage: 85 - 264 VAC # of Outputs: Single RoHS Special Features • • • • • • • • • • 150 W on main channel with only 200 LFM Low profile fits 1U applications Active PFC and EN61000-3-2 compliant Integrated control and monitoring features Overcurrent, overvoltage and overtemperature protection Compliance to EN55022-B conducted noise standard 12 V fan output 5 V standby output (optional) RoHS compliant 2 year warranty Safety • VDE EN60601-1/IEC60601-1 • UL2601-1/CSA22.2 • No. 601-1 Electrical Specifications Input Input voltage range: Universal Input Input frequency range: 85 - 264 Vac 47-63 Hz Input surge current: 264 Vac (cold start) 40 A max. Safety ground leakage current: 264 Vac, 50 Hz 150 µA Input current: 120 Vac @ 150 W 230 Vac @ 150 W 1.8 A rms 0.8 A rms Input fuse: UL/IEC127 T 3.15 A, 250 Vac Output Adjustment Range: ± 10% Total regulation (line and load): Main output Auxiliary outputs Fan output Turn-on delay: @120 Vac Input ± 3% ± 5% ± 10% Transient response: 5% max. dev., 1 ms max. recovery to 1% Main output 25% to 75% step at 0.5 A/µs Temperature coefficient: 2.0 s max. ± 0.02%/°C Overvoltage protection: Main outputs 25%, ± 5% Short circuit protection: Current limited Continuous Minimum output current: Singles 0A Fan voltage output: See Note 9 12 V @ 0.5 A Embedded Power for Business-Critical Continuity Rev.7.8.09_140 TLP150 Medical Series of 4 EMC Characteristics (5) Conducted emissions: EN55022, FCC part 15 Level B Harmonic current correction: EN61000-3-2 Compliant ESD air: EN61000-4-2 Level 3 ESD contact: EN61000-4-2 Level 3 Radiated immunity: EN61000-4-3 Level 3 Fast transients: EN61000-4-4 Level 4 Surge: EN61000-4-5 Level 4 Conducted immunity: EN61000-4-6 Level 3 Hold-up time: 850 Vac @ 60 Hz 20 ms @ 150 W Efficiency: 115 Vac @ 150 W 230 Vac @ 150 W 81% typ. 84% typ. Isolation voltage: Input/output Input/chassis 4000 Vac 1500 Vac Weight: 260g (9.2 oz) MTBF (@ 25 ºC): Telcordia SR-332 MIL-HDBK-217F General Specifications 900,000 hours min. 350,000 hours min. Environmental Specifications Thermal performance: Operating ambient, (See derating curve) 0° C to +70 °C Non-operating -40 °C to +85 °C 150 W Relative humidity: 0 °C to 50 °C ambient, 200 LFM forced air 0 °C to 50 °C ambient, convection cooled 50 °C to 70 °C ambient, convection cooled Non-condensing Altitude: Operating 10,000 feet max. 100 W Derate linearly to 50% load 5 - 95% RH Non-operating 30,000 feet max. Vibration (See Note 7): 5 - 500 Hz 2.4 G rms peak Shock: per MIL-STD-810E 516.4 Part IV Embedded Power for Business-Critical Continuity Rev.7.8.09_140 TLP150 Medical Series of 4 Ordering Information Output Voltage Output Current Ripple Total Regulation Model Numbers 12.5A 120 mV ± 3.0% TLP150N-99S12J 6.3 A 240 mV ± 3.0% TLP150N-99S24J Min Max (free air)(1,4) Max (forced air)(2,4) 12 V 0A 8.4 A 24 V 0A 4.2A Notes 1 Free air convection. Maximum continuous output power not to exceed 100 W. Refer to Figure 1 for the derating curve. 2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not to exceed 150 W. 3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF tantalum capacitor and a 0.1 µF ceramic capacitor. 4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. For optimum reliability no part of the heatsink should exceed 115 °C and no semi-conductor case temperature should exceed 120 °C. 5 No external filtering required during conducted emissions testing but some applications may require additional filtering to achieve system compliance. Compliance with radiated EMI specifications may require mounting in a suitable enclosure. 6 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G. 8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output and/or remote ON/OFF control is required e.g. TLP150N-99S12FJ. 9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is available whenever ac input is present, regardless of remote ON/OFF signal status. 10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 11 NOTICE: Some models do not support all options. Please contact your local Emerson representative or use the on-line model number search tool at http://www.PowerConversion.com to find a suitable alternative.. DERATING CURVE Output Power (Watts) 150 W 200 LFM (1.0 m/s) FORCED AIR COOLING 100 W 75 W NATURAL CONVECTION COOLING 50 W 0W 0C 10 C 20 C 30 C 40 C 50 C 60 C 70 C Figure 1: Derating Curve Outline Dimensions 5.000 (127.00) 4.550 (115.57) J1 1 Neutral FAN 1 Live J2 1 J4 1 R88 Ground/Earth 0.225 (5.72) ø0.156 (4 Places) Dimensions in Inches (mm) Figure 2: Mechanical Drawing 0.225 (5.72) 2.550 (64.77) 3.000 (76.20) J3 Trimmer Adjust Output Voltage 1 J301 Total Height 1.250 (31.75) Embedded Power for Business-Critical Continuity Connector and Mating Connector Types Connector J1 J3 Type Molex 09-65-2038 (5273 series) void pin 2 or equivalent Molex 09-65-2068 (5273 series) or equivalent Leoco 2421P04H000 (2421 series) or equivalent J301 (Optional) Fan Molex 22-23-2021(6373 series) or equivalent Mating Connector Type Molex 09-52-4034 (5239 series) or equivalent with Molex 08-52-0072 (2478 series) or equivalent crimp terminals Molex 09-52-4064 (5239 series) or equivalent with Molex 08-52-0072 (2478 series) or equivalent crimp terminals Leoco 2420S04000 (2420 series) or equivalent with Leoco 2453TPH00V1 (2453T series) or equivalent crimp terminals or JST EHR-4 (EH series) or equivalent with JST SEH-001T-P0.6 (EH series) or equivalent crimp terminals Molex 22-01-3027 (2695 series) or equivalent with Molex 08-50-0113 (2759 series) or equivalent crimp terminals Americas Rev.7.8.09_140 TLP150 Medical Series of 4 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone:+1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone:+44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) J3 Pin Connections J1 Pin Connections Pin 1 Pin 3 Neutral Live J2 Tab Connections Tan 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone:+852 2176 3333 Facsimile: +852 2176 3888 Ground/Earth Pin 1 RTN Main Return Pin 2 RTN Main Return Pin 3 RTN Main Return Pin 4 Vo +Main Output Pin 5 Vo +Main Output Pin 6 Vo +Main Output J4 Pin Connections For global contact, visit: www.PowerConversion.com techsupport.embeddedpower@ emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. -S -Vo Remote Sense Pin 2 DC OK DC Power Good Signal Pin 3 PW OK Power Good Pin 4 LS Load Share Signal AC Power Pin 5 +S +Vo Remote Sense Connectivity Pin 6 SGND Signal Common Pin 1 DC Power Embedded Computing J301 Pin Connections (Optional) Embedded Power Pin 1 5 Vsb Standby Voltage Monitoring Pin 2 SGND Signal Common Pin 3 Reserved Do Not Connect Outside Plant Pin 4 PS OFF Remote ON/OFF Signal Fan Pin Connections Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Pin 1 +12 V Fan Voltage Pin 2 +SGND Return Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.