FUJI EDS2-1G

J,E,K Type THERMOCOUPLES FOR GENERAL USE
DATA SHEET
FTA,B,D
These thermocouples are convenient for measuring
a wide range of temperature in general plants, and are
availble in J, E and K type.
They are insulated with a porcelain tube, and then
housed in a metal protecting tube for heat-, pressure-and
corrosion-proofing.
SPECIFICATIONS
Applicable standard:
JIS C 1602—1995
Thermocouple element:
Material;
Symbol
J
Diameter of element;
φ1, φ3.2
Normal limit and allowable overheat limit;
Material
Positive lead
Negative lead
Steel
Alloy mainly made from copper
and nickel
E
Alloy mainly made from
nickel and chrome
Alloy mainly made from copper
and nickel
K
Alloy mainly made from
nickel and chrome
Alloy mainly made from nickel
Note: Positive lead means the one connected to positive terminal of
the instrument measuring thermoelectromotive force, and negative lead means the one connected to the opposite terminal.
Class;
Class
Symbol of material
1
J, E, K
2
J, E, K
3
E, K
Note: Class3 is applicable only to low temperatures below 40°C.
Temperature accuracy;
Symbol Class
1
K
2
3
1
E
2
3
1
J
2
Measured
temperature
(˚C)
-40˚Cormore,lessthan+375˚C
Tolerance
±2.5˚C
333˚Cormore,lessthan1200˚C ±0.0075•|t|
-167˚Cormore,lessthan+40˚C
Normal
limit
[°C]
Allowable overheat
limit
[°C]
J
φ1
450
550
φ3.2
600
750
E
φ1
500
550
φ3.2
700
800
K
φ1
φ3.2
750
950
1000
1200
Note: The normal limit means the temperature limit up
to which the thermocouple can be used continuously in air.
Allowable overheat limit means the temperature
limit up to which the thermocouple can be used
for a short time, when necessary.
Material of protecting tube:
S ; 304 stainless steel R ; 310S stainless steel
W; 316 stainless steel U ; 27Cr
*T; 316L stainless steel J ; 20Cr-80Ni
Mounting and protecting tube form:
Protecting
tube form
±1.5˚C
375˚Cormore,lessthan1000˚C ±0.004•|t|
-40˚Cormore,lessthan+333˚C
Diameter of
Symbol element
[mm]
Mounting form
Insertion type
±2.5˚C
A
D
F
—
J
—
M
Q
-200˚Cormore,lessthan-167˚C ±0.015•|t|
-40˚Cormore,lessthan+375˚C
±1.5˚C
375˚Cormore,lessthan800˚C
±0.004•|t|
-40˚Cormore,lessthan+333˚C
±2.5˚C
333˚Cormore,lessthan900˚C
±0.0075•|t|
-167˚Cormore,lessthan+40˚C
±2.5˚C
Screw-in type
Screw-in type
-200˚Cormore,lessthan-167˚C ±0.015•|t|
-40˚Cormore,lessthan+375˚C
±1.5˚C
375˚Cormore,lessthan750˚C
±0.004•|t|
-40˚Cormore,lessthan+333˚C
±2.5˚C
333˚Cormore,lessthan750˚C
±0.0075•|t|
Note:Tolerancemeansthemaximumallowablelimitofthe
valuecalculatedbysubtractingthetemperatureof
thetemperaturemeasuringjunctionfromthe
temperatureobtainedbyconvertingthethermal
electromotiveforcebythereferencethermal
electromotiveforce.
|t|isthevalueindicatedbytemperature(˚C)thatis
Flange type
Note: The thermocouple of diameter φ27 in protecting
tube form is applicable to the case where material
of protecting tube is J or U.
In the case of U, and with mounting form D and Q,
the double element is applicable.
EDS2-1g
Date
Jan. 31, 2007
FTA,B,D
CODE SYMBOLS
Mounting method:
Insertion type;
Either movable flange (FTR),
movable airtight flange (FTT),
or movable airtight screw (FTS)
is employed for mounting.
Screw-in type;
G3/4 (PF3/4) or R3/4 (PT3/4) external
thread
Flange type;
JIS 10K-25A • JIS 20K-25A • JIS
30K-25A or JIS 63K-25A
Composition:
Mounting
form
Diameter
of
element
Insertion
type
A
φ1
Insertion
type
D
φ3.2
Protecting
tube material
(Symbol)
S • W • T*
S • W • T*
R • U • J
Movable flange or movable
airtight flange
JIS 5K-25 • 10K-25
Movable airtight screw
G1( PF1), G11/4 (PF11/4)
S • W • T*
Welded screw
G3/4 (PF3/4), R3/4 (PT3/4)
Flange
type
M
φ1
S • W • T*
Welded flange
JIS 10K-25
JIS 20K-25
JIS 30K-25
JIS 63K-25
φ3.2
S • W • T*
R • U • J
3 -
F T B
3 -
F TD
3 -
9 10 11 12
Description
Kind of thermocouple
Jthermocouple
Kthermocouple
Ethermocouple
Element
Singleelement
Doubleelement
Singleelement
Doubleelement
Singleelement
Doubleelement
1
2
3
6
7
8
Movable flange or movable
airtight flange
JIS 5K-25 • 10K-25
Movable airtight screw
G3/4(PF3/4)
φ1
F T A
F T A
F T B
F TD
Mounting method
Screw-in
type
F•J
Flange
type
Q
1 2 3 4 5 6 7 8
A
D
F
J
M
Q
Mounting method *(1)
Insertiontype
Insertiontype
Screw-intype(Forlowtemperature)
Screw-intype(Forhightemperature)
Flangetype
Flangetype
S
W
* T
R
U
J
Protecting tube material *(2)
304stainlesssteel
316stainlesssteel
316Lstainlesssteel
310Sstainlesssteel
27Cr
20Cr-80Ni
Mounting dimension
FlangeJIS10K-25A
FlangeJIS20K-25A
FlangeJIS30K-25(OnlyMtype)
FlangeJIS63K-25(OnlyMtype)
MountingscrewG3/4(PF3/4)
MountingscrewR3/4(PT3/4)
Insertiontype
1
2
3
4
7
8
0
Welded flange
JIS 10K-25
JIS 20K-25
Note: (1) On the J, E thermocouple of mounting method D, Q, protecting tube material is S, W, T.
(2) On the thermocouple of mounting method D and protecting
tube material J, movable airtight screw is PF1/4.
Insertion length
(Accordingtotableofinsertionlength)
Fillininsertionlengthincmunit
500mm050
Ex.:
1000mm100
015
Insertion length: See other table (page 5)
Working conditions:
See other table (pages 3 and 4)
Terminal box:
Material;
Diecast aluminum alloy
Conduit connection;
G1/2 (PF1/2)
Coating;
Baked melamine resin
Finish color; Silver
Standard thermoelectromotive force table:
See other table (page 5)
Scope of delivery: Thermocouple
395
Structure/Explosionproofing
Standardtype
Flameprooftype(d2G4)
Intrinsicallysafeexplosionproofing
(i3nG5)forconnectionwithzener
barrier
Asterisked(*)items:Non-standard
A
C
F
(1) Combination of mounting form and protecting tube form
(2) Combination of protecting tube material
and mounting method
Protecting
tube form
Method
Material
Mounting form
Insertion type
A
D
F
—
Screw-in type
Screw-in type
J
—
M
Q
Flange type
(0.75class)
(0.75class)
(1.5class)  FTD,FTB

(1.5class)  only
(0.4class)
(0.4class)
Note:The thermocouple of diameter φ27 in protecting
tube form is applicable to the case where material
of protecting tube is J or U.
In the case of U, and with mounting form D and Q,
the double element is applicable.
A D F J M Q
S
W
T
R
U
J
Notes:
(1)
mark; Manufacturing possible
(2) mark; FTA, FTD are applicalbe only to
this material
(3) mark; Applicalbe to fexplo-sionprooftype
Working conditions
Working temperature working pressure
Application
Mass{weight} Outline diagrams
1
S
2
FTA
A W
7
T
8
Working temp,; 0 to 450 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm2}
Used for corrosive gas or liquid,
and when the insertion length is
desired to be adjustable
0.5 to 1.4 kg
Fig. 1
1
S
2
FTA
D W
7
T
8
Working temp,; 0 to 600 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm2}
Used for oxidizing atmosphere
(gas), and when the insertion
length is desired to be adjustable
1 to 6 kg
Fig. 2
Used for corrosive gas or liquid,
J type is used for comparatively
high temp.
0.7 to 1.6 kg
Fig. 3
Fig. 4
Model
(
1
S
2 F
W
7 J
T
8
)
)
5
4
MPa
FTA
(
0
0 100
450°C
1
2
3
4
Working temp,; 0 to 450 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
JIS 30K-25 • JIS 63K-25
Material; 304, 316,
316L stainless steel
Used for corrosive gas or liquid,
and when airtightness is
especially required
1.4 to 2.3 kg
(JIS 10K)
1.4 to 2.3 kg
(JIS 20K)
2 to 2.9 kg
(JIS 30K)
2.9 to 3.8 kg
(JIS 63K)
Fig.
Fig.
Fig.
Fig.
1
S
1
2
FTA
Q W
2
7
T
8
Working temp,; 0 to +600 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
Material; 304, 316,
316L stainless steel
Used for oxidizing atmosphere
(gas)
2 to 7 kg
Fig. 9
Fig. 10
1
2
S
3 A
FTD
W
6
T
7
8
Working temp,; ミ200 to +500 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm2}
Used for corrosive gas or liquid,
and when the insertion length is
desired to be adjustable
0.5 to 1.4 kg
Fig. 1
1
2
S
3
D W
FTD
6
T
7
8
Working temp,; ミ200 to +700 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm2}
Used for oxidizing atmosphere
(gas), and when the insertion
length is desired to be adjustable
1 to 6 kg
Fig. 2
Used for corrosive gas or liquid,
J type is used for comparatively
high temp.
0.7 to 1.6 kg
Fig. 3
Fig. 4
Working temp,; ミ200 to +500 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
JIS 30K-25 • JIS 63K-25
Material; 304, 316,
316L stainless steel
Used for corrosive gas or liquid,
and when airtightness is
especially required
1.4 to 2.3 kg
(JIS 10K)
1.4 to 2.3 kg
(JIS 20K)
2 to 2.9 kg
(JIS 30K)
2.9 to 3.8 kg
(JIS 63K)
Fig.
Fig.
Fig.
Fig.
Working temp,; ミ200 to +700 。C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
Material; 304 stainless steel
Used for oxidizing atmosphere
(gas), and when airtightness is
FTA.
especially required
2 to 7 kg
Fig. 9
Fig. 10
FTA
1
S
2
M W
7
T
8
(
(
1
2
S
3 F
FTD
W
6 J
T
7
8
1
2
S
3
FTD
M W
6
T
7
8
5
MPa
4
0
-200
1
2
3
4
1
2
S
3
FTD
Q W 1
6
2
T
7
8
100
)
)
5
6
7
8
500°C
FJ
5
6
7
8
FTA,B,D
Working temperature, working pressure
Application
Mass{weight}
Outline diagrams
1
2
S
3
FTB
A W
6
T
7
8
Working temp.; –200 to +750 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm2}
Used for corrosive gas or liquid,
and when the insertion length is
desired to be adjustable
0.5 to 1.4 kg
Fig. 1
1
2
S
3
FTB
D W
6
T
7
8
Working temp,; –200 to +900 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm2}
Used for oxidizing atmosphere
(gas), and when the insertion
length is desired to be adjustable
1 to 6 kg
Fig. 2
1
2
FTB
D U
7
8
Working temp,; 0 to 1000 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm 2}
1
2
FTB
D R
7
8
Working temp,; 0 to 1000 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm 2}
1
2
D J
7
8
Working temp,; 0 to 1000 °C
Working pressure; Atmospheric pressure
When both movable airtight screw and
flange are used, working pressure can
be up to 0.1MPa {1.02kgf/cm 2}
J type is used for comparatively
high temp.
Used for corrosive gas or liquid,
0.7 to 1.6 kg
Fig. 3
Fig. 4
FTB
1
2
S
3 F
FTB
W
6 J
T
7
8
(
(
(
(
(
5
4
MPa
Model
)
)
)
)
)
Used for high temp. gas including sulfur gas and carbon gas
Used for high temp. gas exclud-
ing sulfur gas
Used when mechanical strength
is required and for high temp.
gas excluding sulfur gas
Used for corrosive gas or liquid,
0.5
0
-200
100
500
750°C
1
2
1
S
3
2
FTB
M W
6
3
T
7
4
8
Working temp,; –200 to +750 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
JIS 30K-25 • JIS 63K-25
Material; 304, 316,
316L stainless steel
and when airtightness is especially required
Used for oxidizing atmosphere
1.4 to 2.3 kg
(JIS 10K)
1.4 to 2.3 kg
(JIS 20K)
2 to 2.9 kg
(JIS 30K)
2.9 to 3.8 kg
(JIS 63K)
Fig.
Fig.
Fig.
Fig.
1
2
S
1
3
FTB
Q W
2
6
T
7
8
Working temp,; –200 to +900 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
Material; 304 stainless steel
(gas)
Used for high temp. gas includ-
2 to 7 kg
Fig. 9
Fig. 10
1
2
1
FTB
Q U
7
2
8
Working temp,; 0 to 1000 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
Material; 304 stainless steel
ing sulfur gas and carbon gas
Used for high temp. gas excluding sulfur gas
1
2
1
FTB
Q R
7
2
8
Working temp,; 0 to 1000 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
Material; 304 stainless steel
Used when mechanical strength
is required and for high temp.
1
2
1
FTB
Q J
7
2
8
Working temp,; 0 to 1000 °C
Working pressure;
Below flange (JIS) nominal pressure
JIS 10K-25 • JIS 20K-25
Material; 304 stainless steel
gas excluding sulfur gas
FTB7. FJ
5
6
7
8
Insertion length [Dimension "L" of "Outline Diagrams"]
Insertion length "L"
Mounting
method
A
D
F
Insertion
length
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
Insertion length "L"
J
M
150
200
250
300
350
400
450
500
550
600
650
700
750
Q
150
200
250
300
350
400
450
500
550
600
650
700
750
800
200
250
300
350
400
450
500
550
600
650
700
750
800
Mounting A
method
D
950
1050
1150
1250
1350
1450
F
950
1050
1150
1250
1350
1450
1550
1650
1750
1850
1950
2450
2950
3450
3950
Insertion
length
J
900
1000
1100
1200
1300
1400
M
800
900
1000
1100
1200
1300
Q
850
950
1050
1150
1250
1350
Standard thermoelectromotive force of J thermocouple (Unit: µV)
850
950
1050
1150
1250
1350
1450
1550
1650
1750
1850
2350
2850
3350
3850
JIS C 1602-1995
Temp.
–100
[°C]
0 Temp.
[°C]
0 100 200
300
0
–4633
404
0
501
0
0
507
5269 10779
545
555
16327
554
21848 27393
552
560
33102 39132
587
623
45494 647 –10
–5037
389
–501
494
10
507
512
5814
546
11334
555
16881
553
22400 27953
552
563
33689 39755
590
627
46141
645
10
–20
–5426
375
−995
487
20
1019
518
6360
549
11889
556
17434
552
22952 28516
552
564
34279 40382
594
630
46786
645
20
–30
–5801
358
−1482
479
30
1537
522
6909 12445
550
555
17986
552
23504 29080
553
567
34873
597
41012
633
47431
643
30
–40
–6159
341
−1961
470
40
2059
526
7459 13000
551
555
18538
552
24057 29647
553
569
35470 41645
601
636
48074
641
40
–50
–6500
321
–2431
462
50
2585
531
8010 13555
552
555
19090
552
24610 30216
554
572
36071 42281
604
638
48715
638
50
–60
–6821
302
–2893
451
60
3116
534
8562
553
14110
555
19642
552
25164 30788
556
574
36675 42919
609
640
49353
636
60
–70
–7123
280
–3344
442
70
3650
537
9115 14665
554
554
20194
551
25720 31362
556
577
37284 43559
612
644
49989
633
70
–80
–7403
256
–3786
429
80
4187
539
9669
555
15219
554
20745
552
26276 31939
558
580
37896 44203
616
645
50622
629
80
–90
–7659
231
–4215
418
90
4726
543
10224 15773
555
554
21297
551
26834 32519
559
583
38512 44848
620
646
51251
626
90
–100
–7890
–4633
100
5269
10779 16327
21848
27393 33102
39132 45494
51877 100
400
500
600 700
800
Temp.
[°C]
0
Remarks: Thermoelectromotive force values shown in the above table are when temperature of reference junction is 0 °C
Standard thermoelectromotive force of E thermocouple (Unit: µV)
Temp.
–100
[°C]
0 Temp.
[°C]
0 0
−5237
444
0
582
0
0
591
–10
−5681
426
−582
570
10
–20
−6107 −1152
409
557
–30
Temp.
[°C]
200
300
400
500
600 700
800
900
6319
679
13421
743
21036
781
28946
801
37005
810
45093
807
53112
796
61017
784
68787
767 591
601
6998
687
14164
748
21817
783
29747
803
37815
809
45900 53908
805
795
61801
782
69554
765
10
20
1192
609
7685
694
14912
752
22600
786
30550
804
38624
810
46705 54703
804
794
62583
781
70319
763
20
−6516 −1709
391
546
30
1801
619
8379
702
15664
756
23386
788
31354
805
39434
809
47509 55497
804
792
63364
780
71082
762
30
–40
−6907 −2255
372
532
40
2420
628
9081
708
16420
761
24174
790
32159
806
40243
810
48313 56289
803
791
64144
778
71844
759
40
–50
−7279 −2787
353
519
50
3048
637
9789
714
17181
764
24964
793
32965
807
41053
809
49116 57080
801
790
64922
776
72603
757
50
–60
−7632 −3306
331
505
60
3685
645
10503
721
17945
768
25757
795
33772
807
41862
809
49917 57870
801
789
65698
775
73360
755
60
–70
−7963 −3811
310
491
70
4330
655
11224
727
18713
771
26552
796
34579
808
42671
808
50718 58659
799
787
66473
773
74115
754
70
–80
−8273 −4302
288
475
80
4985
663
11951
733
19484
775
27348
798
35387
809
43479
806
51517 59446
798
786
67246
771
74869
752
80
–90
−8561 −4777
264
460
90
5648
671
12684
737
20259
777
28146
800
36196
809
44285
808
52315 60232
797
785
68017
770
75621
752
90
–100
−8825 −5237
100
6319
13421
21036
28946
37005
45093
53112
68787
76373 100
100 JIS C 1602-1995
61017
0
Remarks: Thermoelectromotive force values shown in the above table are when temperature of reference junction is 0 °C
FTA,B,D
Standard thermoelectromotive force of K thermocouple (Unit: µV)
JIS C 1602-1995
Temp.
[°C]
–100
0
Temp.
[°C]
–90
−3554
298
−3852
286
−4138
273
−4411
258
−4669
244
−4913
228
−5141
213
−5354
196
−5550
180
−5730
161
0
392 −392 386
−778 378
−1156 371
−1527 362
−1889 354
−2243 344
−2587 333
−2920
323 −3243
311 –100
−5891
0
–10
–20
–30
–40
–50
–60
–70
–80
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
52410
349
52759
347
53106
345
53451
344
53795
343
54138
341
54479
340
54819
90
0
397
397
401
798
405
1203
409
1612
411
2023
413
2436
415
2851
416
3267
415
3682
414
4096
413
4509
411
4920
408
5328
407
5735
403
6138
402
6540
401
6941
399
7340
399
7739
399
8138
401
8539
401
8940
403
9343
404
9747
406
10153
408
10561
410
10971
411
11382
413
11795
414
12209
415
12624
416
13040
417
13457
417
13874
419
14293
420
14713
420
15133
421
15554
421
15975
422
16397
423
16820
423
17243
424
17667
424
18091
425
18516
425
18941
425
19366
426
19792
426
20218
426
20644
427
21071
426
21497
427
21924
426
22350
426
22776
427
23203
426
23629
426
24055
425
24480
425
24905
425
25330
425
25755
424
26179
423
26602
423
27025
422
27447
422
27869
420
28289
421
28710
419
29129
419
29548
417
29965
417
30382
416
30798
415
31213
415
31628
413
32041
412
32453
412
32865
410
33275
410
33685
408
34093
408
34501
407
34908
405
35313
405
35718
403
36121
403
36524
401
36925
401
37326
399
37725
399
38124
398
38522
396
38918
396
39314
394
39708
393
40101
393
40494
391
40885
391
41276
389
41665
388
42053
387
42440
386
42826
385
43211
384
43595
383
43978
381
44359
381
44740
379
45119
378
45497
376
45873
376
46249
374
46623
372
46995
372
47367
370
47737
368
48105
368
48473
365
48838
364
49202
363
49565
361
49926
360
50286
358
50644
356
51000
355
51355
353
51708
352
52060
350
−3554 100
4096
8138
12209
16397
20644
24905
29129
33275 37326
41276
45119
48838
52410
0
10
20
30
40
50
60
70
80
Temp.
[°C]
10
20
30
40
50
60
70
80
90
100
Remarks: Thermoelectromotive force values shown in the above table are when the temperature of reference junction is 0 °C
OUTLINE DIAGRAM
[Unit:mm] (Refer to working conditions of page 3)
Determine insertion length "L" by collating the 5th digit
of code symbols with the table shown on page 5. For
example, when the 5th digit of code symbol is A, select
"L" from 150mm to 1450mm (twenty two varieties) by the
table shown on page 5.
Insertion type
Fig. 1
1
2
A
S
A
3
A W 03 - •••
FT B
F
6
D
T
7
8
Fig. 2
1
S, R
2
A
A
W, J
3
D
03 - ••• F
FT B
T
6
D
U
7
8
Note: φD is as follows:
0
Element
Protecting
tube material
Single and double
304, 22
316,
316L stainless steel
φD
Single 27Cr
21.3
Double
27Cr
27
Single and double
20Cr-80Ni
27
Screw-in type
Fig. 3
Fig. 4
Flange type
1
2
A
S
A
3 F
W 73 - •••
FT B
F
6 J
D
T
7
8
Fig. 5
1
2
A
S
A
3
M W 13 - •••
FT B
F
6
D
T
7
8
Fig. 6
1
2
A
S
A
3
M W 23 - •••
FT B
F
6
D
T
7
8
Fig. 7
1
2
A
S
A
3
M W 43 - •••
FT B
F
6
D
T
7
8
1
2
A
S
A
3 F
W 83 - •••
FT B
F
6 J
D
T
7
8
Note: Dimension "A" in case of screw-in type
Dimension "A"
For low
temp.
50mm
For high
temp.
150mm
FTA,B,D
Terminal box for flameproof type
100
125
G1/2
(PF1/2)
Fig. 8
1
2
A
S
A
3
M W 33 - •••
FT B
F
6
D
T
7
8
Movable airtight screw (type FTS)
2, 4, 6 in 4th digit of code
Type
Fig. 9
1
S, R
2
A
A
W, J
3
Q
13 - ••• F
FT B
T
6
D
U
7
8
Protecting tube diameter of Fig. 9, 10
Protecting tube
material
Element
φD
φD1
304,
316,
316L stainless steel
Single
Double
22
29
27Cr
Single
Double
21.3
27
29
20Cr-80Ni
Single
Double
27
34
φd1
φd2
a
b
Protecting tube
Approx. ℓ outer dia. (φD)
Mass
{weight}
[kg]
FTS6E 31
R1 1/4
58
(PT1 1/4)
30
100
30
1.2
FTS6D 28
R1 1/4
58
(PT1 1/4)
30
100
25 to 27
1.2
FTS4C 24
R1 (PT1) 50
20
80
21.3 to 22
0.8
FTS2A 13
R3/4
(PT3/4)
20
80
12
0.8
38
Note: Material is SS400
1, 3, 5 in 4th digit of code
Type
1
2
A
S, U
A
3
Fig. 10 FT B 6 Q W,R 23 - ••• F
D
T J
7
8
Cap
φd1
φd2
φa
b
c
Protecting Mass
Approx. ℓ tube outer {weight}
dia. (φD)
[kg]
FTS5E 31
G1 1/4
69
(PF1 1/4)
58
30
100
30
1.2
FTS5D 28
G1 1/4
69
(PF1 1/4)
58
30
100
25 to 27
1.2
FTS3C 24
G1 (PF1) 59
50
20
80
21.3 to 22
0.8
FTS1A 13
G3/4
(PF3/4)
38
20
80
12
0.8
48
Note: Material is SS400
Movable airtight flange (type FTT)
Movable flange (type FTR)
JIS 10K-50 flange
φd
Protecting tube
outer dia. (φD)
31
30
28
26.8 • 27
24
21.3 • 21.7 • 22
Material
SS400
JIS 10K-25 flange
φd
Protecting tube
outer dia. (φD)
FTT2D
28
26.8 • 27
FTT2C
24
21.3 • 21.7 • 22
Type
FTT2A
13
FC200
JIS 5K-25 flange
φd
Protecting tube
outer dia. (φD)
FTT1D
28
26.8 • 27
FTT1C
24
21.3 • 21.7 • 22
FTT1A
13
12
φd
Protecting tube
outer dia. (φD)
50
49
31
30
28
25 to 27
24
21.3 to 22
13
12
Material
Material
SS400
JIS 10K-25 flange
Material
12
Type
JIS 10K-50 flange
Type
φd
Protecting tube
outer dia. (φD)
FTR2D
28
25 to 27
FTR2C
24
21.3 to 22
FTR2A
13
12
Material
FC200
JIS 5K-25 flange
Type
φd
Protecting tube
outer dia. (φD)
FTR1D
28
25 to 27
FTR1C
24
21.3 to 22
FTR1A
13
12
Material
FC200
FC200
FTA,B,D
CautiononSafety
*Beforeusingthisproduct,besuretoreaditsinstructionmanualinadvance.
Head Office
GateCityOhsaki,EastTower,11-2,Osaki1-chome,
Shinagawa-ku,Tokyo141-0032,Japan
http://www.fesys.co.jp/eng
Instrumentation Div.
International Sales Dept.
No.1,Fuji-machi,Hino-city,Tokyo,191-8502Japan
Phone:81-42-585-6201,6202Fax:81-42-585-6187
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
PrintedinJapan