FUJI EDSX5-82K

SMALL FLANGE REMOTE SEAL TYPE
PRESSURE TRANSMITTER
DATA SHEET
FKW...4
The FCX –A2 small flange remote seal type pressure transmitter accurately measures gauge pressure and transmits a
proportional 4 to 20mA signal.
The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor
technology to provide exceptional performance and functionality.
Totally welded construction of the seals assures excellent
reliability in high temperature and highly corrosive process
conditions.
FEATURES
1. Directly connectable to 1-1/2in and 2in flanges
The transmitter is connectable to 1-1/2in and 2in pipes
without a reducer.
2. Connectable to 1/2in and 3/4in pipes
Use of direct mounting adapter allows the transmitter to
be connected to the following process.
1/2in and 3/4in flanges
Screw connection 1/2-14NPT, 3/4-14NPT, Rc1/2, Rc3/4
3. Minimum environmental influence
The “Floating Cell” design which protects the pressure
sensor against changes in temperature, and overpressure
substantially reduces total measurement error in actual
field applications.
4. Fuji/HART ® bilingual communications protocol and
FOUNDATION™ fieldbus and Profibus™ compatibility
FCX–A2 series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®.
Any HART® compatible devices can communicate with
FCX–A2. Further, by upgrading electronics FOUNDATION™ fieldbus and Profibus™ are also available.
5. Application flexibility
Various options that render the FCX–A2 suitable for
almost any process applications include:
– Analog indicator at either the electronics side or terminal side
– Full range of hazardous area approvals
– Built-in RFI filter and lightning arrester
– 5-digit LCD meter with engineering unit
– Stainless steel electronics housing
– Wide selection of materials
– High temperature, vacuum seals
6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,
Over Scale: 20.8 to 21.6mA)
Burnout signal level is adjustable using Model FXW Hand
Held Communicator (HHC) to comply with NAMUR NE43.
7. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level
as wet calibration.
EDSX5-82k
Date
Apr. 3, 2007
FKW...4
SPECIFICATIONS
Authorities
ATEX
Functional specifications
Service:
Liquid, gas, or vapour
Span, range, and overrange limit:
Span limit [kPa]{bar}
Range limit
[kPa]{bar}
Type
Min.
F KW
2
F KW
3
F KW
4
Max.
50
{0.5}
300
{3}
1000
{10}
500
{5}
3000
{30}
10000
{100}
–100 to +500
{–1 to +5}
–100 to +3000
{–1 to +30}
–100 to 10000
{–1 to 100}
Overrange
limit
[MPa] {bar}
1.5
{15}
4.5
{45}
15
{150}
Lower range limit (vacuum limit) ;
Silicone fill sensor: See Fig. 1
Fluorinated fill sensor: Atmospheric pressure
– Conversion factors to different units;
1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377psi
1kPa=10mbar=101.9716mmH2O=4.01463inH2O
Output signal:
4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal.
Power supply:
Transmitter operates on 10.5V to 45V DC
at transmitter terminals.
10.5V to 32V DC for the units with optional arrester.
Load limitations: see figure below
Factory
Mutual
Load resistance
Operating
area
24V
250
0
10
45V
16.1
10.5V
Power voltage
50
[V]
Note: For communication with HHC (Model: FXW), min. of 250Ω is required.
Hazardous locations:
Authorities
ATEX
Ex II 2 GD
EEx d IIC T6 IP66/67 T85°C
Tamb = -40°C to +65°C
EEx d IIC T5 IP66/67 T100°C
Tamb = -40°C to +85°C
Factory
Mutual
Class I
Div.1 Groups B, C, D
T6 Type 4X
Class II III
Div.1 Groups E, F, G
T6 Type 4X
Tamb max = +60°C
CSA
-
TIIS
Ex do IIB+H2 T4
Tamb max = +55°C
Maximum process temp.=+120°C
IECEx
Scheme
/SAA
Ex d IIC T5 IP66/67 pending
Tamb = -40°C to +85°C
Ex d IIC T6 IP66/67 pending
Tamb = -40°C to +65°C
(Note)
2
Flameproof
(1) HHC: Hand Held Communicator
A,B,D
Y,G,H,S
-40°C to +85°C
Y,G,H,S
-20°C to +80°C
Q,S,4,5
Y,G,H,S
-20°C to +60°C
E,F,H
Y,G,H,S
-40°C to +60°C
W,A,D
-10°C to +60°C
Entity Parameters:
Vmax=42.4V, Imax=113mA, Pi=1W,
Ci=34.2nF, Li=1.134mH
CSA
Class I
Div.1 Groups A, B, C, D
Class II
Div.1 Groups E, F, G
Class III
Div.1
Temp Code T4 Tamb max = +40°C
Temp Code T3C Tamb max = +85°C
Entity Parameters:
Vmax=28V, Imax=93mA, Ci=27nF (Without Arrester),
Ci=34.2nF (With Arrester), Li=1.4mH
TIIS
Ex ia IIC T4
Tamb max = +60°C
Entity Parameter:
Ui=28V, Ii=94.3mA, Pi=0.66W,
Ci=32.6nF, Li=1.134mH
IECEx
Scheme
/SAA
Ex ia IIC T4 IP66/67
Tamb = -40°C to +70°C
Ex ia IIC T5 IP66/67
Tamb = -40°C to +50°C
Entity Parameter:
Ui=28V, Ii=93.3mA, Pi=0.66W,
Ci=0.033µF, Li=1.034mH
1500
500
Tamb
L,P,1,2
-
1533Ω
600Ω
Class I II III
Div.1 Groups A, B, C, D, E, F, G
T4 Entity Type 4X
Model code
13th digit
9th digit
[Ω]
1000
Ex II 1 GD
EEx ia IIC T5 Tamb = -40°C to +40°C
EEx ia IIC T4 Tamb = -40°C to +80°C
Entity Parameters:
Ui=28V, Ii=93.3mA, Pi=0.66W,
Ci=27nF (Without Arrester),
Ci=34.2nF (With Arrester), Li=1.134mH
–
2000
Intrinsic safety
ATEX
“Output Overscale”:
Adjustable within the range 20.8mA to
21.6mA from HHC(1)
“Output Underscale”:
Adjustable within the range 3.2mA to
3.8mA from HHC(1)
Type n
Nonincendive
Authorities
Ex II 3 GD
EEx nL IIC T5 Tamb = -40°C to +40°C
EEx nL IIC T4 Tamb = -40°C to +80°C
Specific Parameters:
Model without arrester:
Ui=42.4V, Ii=113mA, Pi=1W,
Ci=27nF, Li=1.134mH
Model with arrester:
Ui=32V, Ii=113mA, Pi=1W,
Ci=34.2nF, Li=1.134mH
3.2
Class I II III
Div.2 Groups A, B, C, D, F, G
T4 Entity Type 4X
Model code
13th digit
9th digit
CSA
Tamb
A,B,D
Y,G,H,S
-40°C to +85°C
L,P,1,2
Y,G,H,S
-20°C to +80°C
Q,S,4,5
Y,G,H,S
-20°C to +60°C
E,F,H
Y,G,H,S
-40°C to +60°C
W,A,D
-10°C to +60°C
-
Class I
Div.2 Groups A, B, C, D
Class II
Div.2 Groups E, F, G
Class III
Div.2
Temp Code T4 Tamb max = +40°C
Temp Code T3C Tamb max = +85°C
Entity Parameters:
Vmax=28V, Ci=27nF (Without Arrester),
Ci=34.2nF (With Arrester), Li=1.4mH
TIIS
-
IECEx
Scheme
/SAA
-
20 20.8
21.6 [mA]
Over scale
Burnout
EEx nAL IIC T5 Tamb = -40°C to +40°C
EEx nAL IIC T4 Tamb = -40°C to +80°C
Specific Parameters:
Model without arrester:
Umax=42.4V, Imax=113mA, Pmax=1W,
Model with arrester:
Umax=32V, Imax=113mA, Pmax=1W
Factory
Mutual
3.8 4
Zero/span adjustment:
Zero and span are adjustable from the
HHC(1). Zero and span are also adjustable
externally from the adjustment screw
(Span adjustment is not available with 9th
digit code “L, P, Q, S”).
Damping:
Adjustable from HHC or local adjustment
unit with LCD display.
The time constant is adjustable between
0.12 to 32 seconds.
Zero elevation/suppression:
Zero can be elevated or suppressed within
the specified range limit of each sensor
model.
Normal/reverse action:
Selectable from HHC(1)
Indication:
Analog indicator or 5-digit LCD meter, as
specified.
Burnout direction: Selectable from HHC(1)
If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale”
or “Output Underscale” modes.
“Output Hold”:
Output signal is hold as the value just before failure happens.
Normal operating range
Under scale
Probable under range
Burnout
Probable over range
Loop-check output:
Transmitter can be configured to provide
constant signal 3.8mA through 21.6mA by
HHC(1).
Temperature limit:
Ambient: – 15 to +65°C
(– 15 to +60°C for arrester option)
(–10 to +60°C for fluorinated oil fill transmitter)
(–10 to +60°C for silicone oil “H”, “S”)
For explosionproof units (flameproof or intrinsic
safety), ambient temperature must be within the limits specified by each standard.
Process:
Fill fluid
13th digit of
“Code symbols”
Process
temperature
Fluorinated oil
W, A and D
–20 to 120°C
Silicone oil
H
0 to 250°C
– 40 to 120°C
Y and G
S
0 to 250°C
Lower limit
of
static press.
Atmospheric
pressure
2.7kPa abs
{20mmHg
abs}
Storage: – 40 to +70°C
Humidity limit:
0 to 100% RH
Communication: With HHC(1) (Model FXW, consult Data
Sheet No. EDS8-47), following information can be remotely displayed or reconfigured.
Note: HHC’s version must be more than
6.0 (or FXW
1– 3), for FCXA2.
Items
Display
Set
Tag No.
v
v
Model No.
v
v
Serial No.
v
—
Engineering unit
v
v
Range limit
v
—
Measuring range
v
v
Damping
v
v
Linear
v
v
Square root
v
v
Burnout direction
v
v
Calibration
v
v
Output adjust
—
v
Data
v
—
Self diagnoses
v
—
Printer
—
—
External switch lock
v
v
Transmitter display
v
v
Linearize
v
v
Rerange
v
v
Output mode
EMC Conformity:EN61326
3
FKW...4
Performance specifications
Physical specifications
Reference conditions, silicone oil fill, SS316 isolating diaphragms,
4 to 20mA analog output in linear mode.
Accuracy rating: (including linearity, hysteresis, and repeatability)
(Standard)
For spans greater than 1/10 of URL: ± 0.25% of span
For spans below 1/10 of URL:
± 0.17+0.08 0.1 x URL % of span
Span
(Option) (Code; 21th digit H)
For spans greater than 1/10 of URL: ± 0.1% of span
For spans below 1/10 of URL:
± 0.05+0.05 0.1 x URL % of span
Span
Stability:
± 0.2% of upper range limit (URL) for 3
years.
Temperature effect:
Effect per 28°C change between the limits of – 15°C and +65°C
(
)
(
)
Zero shift: ± 0.5%/28°C
(x equal to 1/6.5 URL or more)
URL
Zero shift; ± (0.5
)%/28°C
6.5 x x
(x less than 1/6.5 URL)
Total shift; ± 0.75%/28°C
(x less than 1/6.5 URL or more)
URL
Total shift; ± (0.25 + 0.5
)%/28°C
6.5 x x
(x less than 1/6.5 URL)
Where, x:
Calibrated span
URL:
Maximum span (Upper Range
Limit)
Note : Above specifications are based on the conditions that flange and sensor unit are at
the same temperature and in the same
level. If temperature is different at flange,
capillary or sensor unit, output variation
may increase.
Overrange effect: Zero shift; 0.2% of URL/(1.5 x URL)
Supply voltage effect:
Less than 0.005% of calibrated span per
1V
RFI effect:
Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength
30 V/m when electronics covers on.
(classification: 2-abc: 0.2% span per
SAMA PMC 33.1)
Update period: 120 msec *)
Step response: Time constant: 0.3s *)
Dead time: 0.2s *)
(without electrical damping)
*) Faster response is available as option (maximum
update rate: 25 times per second).
Dielectric strength:
500V AC, 50/60Hz 1 min., between circuit
and earth.
Insulation resistance:
More than 100MΩ/500V DC.
Turn-on time:
4 sec.
Internal resistance for external field indicator:
12Ω or less
4
Electrical connections:
G1 /2, 1 /2-14 NPT, Pg13.5, or M20 x 1.5
conduit, as specified.
1-port (standard) or 2-port with each conduit, as specified.
Process connections:
JIS;
10K, 20K, 30K, 63K –40, 50A
10K, 20K, 30K, 63K –15, 20A (with
Adapter)
ANSI/JPI;
150LB, 300LB, 600LB, –1 1/2", 2"
150LB, 300LB, 600LB, – 1 /2", 3 /4" (with
Adapter)
Screw connection (with Adapter) ;
Rc1/2, Rc3/4, 1/2-14NPT, 3/4-14NPT
Diaphragm extension:
0, 50, 100, 150, or 200mm as specified.
(See model code. Extended diaphragm is
available only with 316L stainless steel diaphragm)
Process-wetted parts material:
Diaphragm: 316L stainless steel, Hastelloy-C
Monel or Tantalum
Flange face: 316 stainless steel, Hastelloy-C
lining, Monel lining or Tantalum lining
Extension: 316 stainless steel
(Refer to “Code symbols”)
Non-wetted parts material:
Electronics housing: Low copper die-cast
aluminum alloy finished with epoxy/
polyurethane double coating (standard), or 316 stainless steel (SCS14 per
JIS G5121), as specified.
Capillary: In case of 11th code “D. E. L”,
PVC armored stainless steel.
In case of 11th code “Q. R. S”, stainless steel armored stainless steel.
Mounting flange: 304 stainless steel or
carbon steel, as specified.
Fill fluid: Silicone oil (standard) or fluorinated oil
Mounting bracket: 304 stainless steel.
Environmental protection:
IEC IP67 and NEMA 6/6P
Mounting:
On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting
Mass {weight}:
Transmitter approximately 10kg without
options.
Add; 0.5kg for mounting bracket
0.8kg for indicator option
4.5kg for stainless steel housing
option
1.5kg per 50mm extension of diaphragm
Optional features
ACCESSORIES
Indicator:
A plug-in analog indicator (2.5% accuracy)
can be housed in the electronics compartment or in the terminal box of the housing.
An optional 5-digit LCD meter with engineering unit is also available.
Local adjustment unit with LCD display:
An optional 5-digit LCD meter with Zero/
Span adjustment function, loop-check
function and damping adjustment function, is available.
Arrester:
A built-in arrester protects the electronics
from lightning surges.
Lightning surge immunity: 4kV (1.2 x
50µs).
Oxygen service: Special cleaning procedures are followed
throughout the process to maintain all process wetted parts oil-free.
The fill fluid is fluorinated oil.
Chlorine service: Oil-free procedures as above. Includes
fluorinated oil for fill.
Degreasing:
Process-wetted parts are cleaned, but the
fill fluid is standard silicone oil. Not for use
on oxygen or chlorine measurement.
Vacuum and high temperature service:
Special silicone oil and filling procedure
are applied.
See Fig.1.
Optional tag plate:
An extra stainless steel tag for customer
tag data is wired to the transmitter.
Coating of cell: Cell's surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive.
Filled liquid:
Silicone (Code Y,G)
[kPa abs]
{m bar abs}
The product conforms to the requirements of the
Electromagnetic compatibility Directive 94/9/EC as detailed
within the technical construction file number TN513035.
The applicable standards used to demonstrate compliance
are :
EMI (Emission)
53.3
{533}
EN61326 : 1997
Class A (standard for Industrial Location)
Frequency range
MHz
Limits
Reference
standard
30 to 230
40dB (µV/m) quasi peak,
measured at 10m distance
CISPR16-1 and
CISPR16-2
230 to 1000
47dB (µV/m) quasi peak,
measured at 10m distance
EMI (Immunity)
EN61326: 1997
Annex A (standard for Industrial Location)
Phenomenon
Electrostatic
discharge
Test value
4kV (Contact)
8kV (Air)
Basic
standard
Performance
criteria
EN61000-4-2
B
80 to 1000MHz
Electromagnetic
10V/m
field
80%AM (1kHz)
EN61000-4-3
A
Rated power
frequency
magnetic field
30A/m
50Hz
EN61000-4-8
A
Burst
2kV
5kHz
EN61000-4-4
B
Surge
1.2µs/50µs
1kV (Line to line)
2kV (Line to ground)
EN61000-4-5
B
Conducted RF
0.15 to 80MHz
3V
80%AM (1kHz)
EN61000-4-6
A
Silicone (Code S)
101
{1010}
Operating pressure
Hand-held communicator:
(Model FXW, refer to Data Sheet No.
EDS8-47)
Z/S board:
Parts No.=ZZPFCX4-A070
When Z/S board is mounted on the FCX–
A2 amplifier unit, external adjustment
screw will be available for zero and span
adjustment.
Note) Definition of performance criteria
A: During testing, normal performance within the
specification limits.
B: During testing, temporary degradation, or loss of
function or performance which is self-recovering.
Operating area
13.3
{133}
Non-operating
area
2.7
{27}
–40 0
60 85 120
Process temperature
200 230 250
[°C ]
Fig. 1 Relation between process temperature and
operating pressure
5
FKW...4
CODE SYMBOLS
1 2 3 4 5 6 7 8
Digit
4
Description
Note
<Conduit connection>
(×1)
G1/2
1/2 - 14NPT (×1)
Combination with 12th digit code
Pg13.5
(×1) "C, E, P, Q" are not available.
M20×1.5
(×1)
G1/2
(×2)
1/2 - 14NPT (×2)
Pg13.5
(×2)
M20 X 1.5 (×2)
5
<Flange>
Material
Size and rating
304 stainless
JIS 10K 40A
steel
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2" ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
Carbon steel
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
None
40A, 1 1/2B
(Wafer type)
50A, 2B
Note 1
Direct mounting adapter connection (* 1)
6
<Span limit [kPa] {bar} >
50.......500 ( 0.5...5)
300.....3000 ( 3...30)
1000...10000 (10...100)
7
<Material/diapharagm extension>
Diaphragm extension (mm)
Flange face
Diaphragm
0
316L stainless steel 316 stainless steel
50
Note 2
100
(* 2)
150
200
0
316L stainless steel
+Au coating
0
Hastelloy-C
Hastelloy-C
0
Monel
Monel
0
Tantalum
Tantalum
Note1: (*1) Direct mounting adapter type is specified at 16th to 20th digit.
Direct mounting adapter is available only for 7th digit code "V".
Note2: (*2) Diaphragm extension is available only for 2" (50A) flanges.
6
F KW
4
A
B
C
D
S
T
V
W
0
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
2
3
4
V
A
B
C
D
J
H
M
T
9 10 11 12 13
14 15 16 17 18 19 20
0
21
Digit No.
of code
1 2 3 4 5 6 7 8
Digit
9
10
11
12
13
14
15
F KW
Description
<Indicator and arrester>
Indicator
Arrester
None
None
Z/S board
Analog, 0 to 100% linear scale
None
attached.
Analog, custom scale
None
None
Yes
Analog, 0 to 100% linear scale
Yes
Analog, custom scale
Yes
Digital, 0 to 100%
None
Digital, custom scale
None
Digital, 0 to 100%
Yes
Digital, custom scale
Yes
Digital, 0 to 100%
(Local adjustment unit with LCD display)
None
Digital, custom scale
(Local adjustment unit with LCD display)
None
Digital, 0 to 100%
(Local adjustment unit with LCD display)
Yes
Digital, custom scale
(Local adjustment unit with LCD display)
Yes
<Approvals for hazardous locations>
None (for ordinary locations)
TIIS, Flameproof (Conduit seal)(Available for 4th digit code "A", "S")
TIIS, Flameproof (Cable gland seal)(Available for 4th digit code "A", "S")
FM, Flameproof (or explosionproof)(Available for 4th digit code "B", "T")
ATEX, Flameproof
IECEx Scheme/SAA, Flameproof (Approval pending)
TIIS, Intrinsic safety
FM, Intrinsic safety and Nonincendive
ATEX, Intrinsic safety
ATEX, Type n
IECEx Scheme/SAA, Intrinsic safety
FM, Combined of Flameproof and Intrinsic safety
<Capillary and mounting bracket>
Mounting bracket
Capillary
Armor of Capillary
Stainless steel
1.5m
PVC
(*5)
3m
5m
1.5m
Stainless steel
3m
5m
<Options>
Extra SS tag plate
Stainless steel elec. housing Coating of cell
None
None
None
Yes
None
None
None
Yes
None
(*3)
Yes
Yes
None
None
None
Yes
Yes
None
Yes
None
Yes
Yes
Yes
Yes
Yes
<Special applications and fill fluid>
Treatment
Fill fluid
Standard
Silicone oil
Standard
Fluorinated oil
Degreasing
Silicone oil
Oxygen service
Fluorinated oil (7th digit code "V", "A", "B", "C" and "D")
Chlorine service
Fluorinated oil (7th digit code "H" and "T")
High temp. 250°C
Silicone oil (7th digit code "V", "A", "B", "C", "D" and "H")
High temp. and vacuum (250°C) Silicone oil (7th digit code "V", "A", "B", "C" and "D")
<Teflon membrane>
None
Yes (Available for 7th digit code "V", "H", "M" and "T".
Not available for 5th digit code "Y" and 13th digit code "H", "S".)
<Bolt/nut> (*4)
None
6th digit code "3"
Cr-Mo alloy hexagon socket head cap bolt/
carbon steel nut
6th digit code "4"
Cr-Mo alloy hexagon bolt/carbon steel nut
304 stainless steel bolt/304 stainless steel nut
Note3: (*3)
Note4: (*4)
Note5: (*5)
Note
9 10 11 12 13
14 15 16 17 18 19 20
4
21
Digit No.
of code
A
B
D
E
F
H
L
P
Q
S
1
2
4
5
A
B
C
D
X
R
G
H
K
P
T
V
Note5
Note3
D
E
L
Q
R
S
Y
B
C
E
M
N
P
Q
Y
W
G
A
D
H
S
Y
C
Note4
Y
A
B
E
Customer tag number can be engraved on standard stainless steel
name plate. If extra tag plate is required, select "Yes".
In case of tropical use, select stainless bolts and nuts.
Available for 13th digit code "Y, W, G, A, D".
7
FKW...4
Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4") connection} and others
Note 1. When odering the instrument with direct mounting adapter, specify “Y” in the 5th digit of Code Symbol, and specify
16th digit to 20th digit.
When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit.
2. Unless otherwise described in the specifications, leave the 21st digit blank.
1 2 3 4 5 6 7 8
Digit
Description
Note
16, 17 <Process connection (direct mounting adapter)>
JIS 10K 15A
JIS 10K 20A
JIS 20K 15A
JIS 20K 20A
JIS 30K 15A
JIS 30K 20A
JIS 63K 15A
JIS 63K 20A
ANSI/JPI 150LB 1/2"
ANSI/JPI 150LB 3/4"
ANSI/JPI 300LB 1/2"
ANSI/JPI 300LB 3/4"
ANSI/JPI 600LB 1/2"
ANSI/JPI 600LB 3/4"
Screw connection Rc1/2
Screw connection Rc3/4
Screw connection Rc1/2 - 14NPT
Screw connection Rc3/4 - 14NPT
18
<Material (direct mounting adapter)>
Note 1
Adapter
Bolts/nuts
(* 1)
316 Stainless Steel
Cr-Mo steel/carbon steel
19
<Vent/drain (for direct mounting adapter)>
Standard
Long type
20
<Gasket (for direct mounting adapter)>
Standard (Teflon)(Only Y, W, G, A and D can be specified on 13th digit).
For high temperature (spiral gasket) (Only H and S can be specified on
13th digit).
21
Note 2
<Other options> (* 2)
High accuracy type
Instruction manual attached
Instruction manual unattached
High accuracy type
Instruction manual unattached
F KW
9 10 11 12 13
14 15 16 17 18 19 20
1 1
1 2
2 1
2 2
3 1
3 2
6 1
6 2
1H
1T
2H
2T
4H
4T
SR
S2
SN
ST
Note1: (* 1) For connection of transmitter receiving pressure unit and direct mounting adapter
Note2: (* 2) In other option is not necessary, 21st digit code is blank.
In case of 21st digit code is blank, instruction manual attached.
ORDERING INFOMATION
When ordering this instrument, specify.
1. CODE SYMBOLS
2. Measuring range.
3. Output orientation (burnout direction) when abnormality is occurred in the transmitter.
Hold / Overscale (21.6mA) / Underscale (3.2mA)
Unless otherwise specified, output hold function is supplied.
4. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S on 9th digit).
5. Tag No. (up to 26 alphanumerical characters), if required.
8
21
4
W
A
N
1
2
H
L
T
Digit No.
of code
OUTLINE DIAGRAM (Unit:mm)
Note) Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
In case of 4th digit code “S.V.W.X”
MTG. Pipe
JIS 50A (2B)
In case of 4th digit code “A.B.C.D.E”
Fastener
(Flameproof only)
In case of 4th digit code “T”
10
8
94.5
U - bolt M8
38
4 holes
9 dia.
ø80
104
Down
88
70
ø80
52.5
105
105
Up
37
Cable gland
(option) Note)
210
58
“B” Conduit conn.
Zero ADJ. screw
(27)
“A” Conduit conn.
With field ind.
N holes
h dia.
Detail “B”
ø13
17
71
M
K
ø84
ø49
ø48
øD
ø15
J
G1/2
191
See table 1
V, H, M, T
A
B
C
D
t
L
Mass approx.
[kg]
0
50
100
150
200
9.5
10.5
11.5
12
12.5
No flange is attached
in case of 5th digit
code “W,X”.
Earth terminal
11th digit of
Capillary
Code symbols length [mm]
D, Q
E, R
L, S
5th digit of
code symbols
øD
øE
øt
N-øh
Flange
0,G
1,H
2,J
3,K
4,L
5,M
6,N
7,P
A,Q
B,R
C,S
D,T
E,U
F,V
140
155
140
155
160
165
175
185
127
152
156
165
156
165
105
120
105
120
120
130
130
145
98.4
120.6
114.3
127
114.3
127
36
36
38
38
42
42
52
54
37.5
39.5
41
42.5
42.5
45.5
4-19
4-19
4-19
8-19
4-23
8-19
4-25
8-23
4-16
4-20
4-23
8-20
4-23
8-20
JIS-10K-40A
JIS-10K-50A
JIS-20K-40A
JIS-20K-50A
JIS-30K-40A
JIS-30K-50A
JIS-63K-40A
JIS-63K-50A
ANSI/JPI-150LB-1 1/2B
ANSI/JPI-150LB-2B
ANSI/JPI-300LB-1 1/2B
ANSI/JPI-300LB-2B
ANSI/JPI-600LB-1 1/2B
ANSI/JPI-600LB-2B
2-M6 screw depth 9
Inner of gasket
Electronics
unit
1500
3000
5000
231
7th digit of
Code symbols
L
43
60
20
Inner of
gasket
øE
Detail “A”
S
2-M8×12
70
120
4th digit of the
code symbols
50
Conduit conn.
K
M
A, S
G1/2
J
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20×1.5
16
5
CONNECTION
DIAGRAM
71
ø84
ø49
+
20
<Wafer type>
Sensor
unit
Table 1
–
CK+
+ CK–
–
+ –
Note) In case of wafer type, flange is excluded
from the scope of supply.
Mount flange, referring to the view.
9
FKW...4
OUTLINE DIAGRAM (Unit:mm)
<With direct mount adaptor>
Note) Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
Long vent/drain plug
(added specification)
(102)
25
Vent/drain plug
(t)
In case of ANSI/JPI-600LB
flange
(6.4)
ø84
øF
øE
øD
In case of 4th digit
code “A.B.C.D.E”
N holes h dia.
S
t
20
80
In case of 4th digit code “T”
Fastener
(Flameproof only)
U - bolt M8
10
8
Zero ADJ. screw
94.5
MTG. pipe
JIS 50A (2B)
In case of 4th digit code
“S.V.W.X”
37
38
4 holes
9 dia.
88
58
ø80
104
105
70
ø80
52.5
105
Up
Down
Cable gland
(option) Note)
(27) “A” Conduit conn.
210
“B” Conduit conn.
With field ind.
Detail “A”
Detail “B”
ø13
M
ø15
191
43
60
K
17
Earth terminal
J
Electronics
unit
G1/2
D, W
M20×1.5
øD
16th of
17th of
code symbols code symbols
1
1
2
2
3
3
6
6
1
1
2
2
4
4
10
1
2
1
2
1
2
1
2
H
T
H
T
H
T
95
100
95
100
115
120
120
135
89
98
95
117
95
117
16
11th digit of
Code symbols
Capillary
length [mm]
D, Q
E, R
L, S
1500
3000
5000
5
øE
øF
t
N-øh
70
75
70
75
80
85
85
95
60.3
69.9
66.7
82.5
66.7
82.5
51
56
51
56
55
60
55
60
34.9
42.9
34.9
42.9
34.9
42.9
12
14
14
16
18
18
23
25
11.5
13
14.5
16
14.5
16
4-15
4-15
4-15
4-15
4-19
4-19
4-19
4-23
4-16
4-16
4-16
4-20
4-16
4-20
231
Table 1
Conduit conn.
4th digit of the
code symbols
J
K
M
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
2-M8×12
Flange
JIS-10K-15A
JIS-10K-20A
JIS-20K-15A
JIS-20K-20A
JIS-30K-15A
JIS-30K-20A
JIS-63K-15A
JIS-63K-20A
ANSI/JPI-150LB 1/2B
ANSI/JPI-150LB 3/4B
ANSI/JPI-300LB 1/2B
ANSI/JPI-300LB 3/4B
ANSI/JPI-600LB 1/2B
ANSI/JPI-600LB 3/4B
70
120
CONNECTION
DIAGRAM
+
–
CK+
+ CK––
+ –
50
Sensor
unit
OUTLINE DIAGRAM (Unit:mm)
<With direct mount adaptor (screw connection type)>
Note) Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
Vent/drain plug
(102)
25
Long vent/drain plug
(added specification)
Press. conn. “D”
ø84
In case of 4th digit
code “A.B.C.D.E”
S
20
23
In case of 4th digit code
“S.V.W.X”
MTG. pipe
JIS 50A (2B)
Fastener
(Flameproof only)
In case of 4th digit code “T”
10
94.5
8
U - bolt M8
ø80
104
105
ø80
4 holes
9 dia.
DOWN
88
70
38
52.5
105
UP
37
58
Cable gland
(option) Note)
Zero ADJ. screw
(27)
210
“B” Conduit conn.
“A” Conduit conn.
With field ind.
191
Detail “A”
60
Detail “B”
ø13
CONNECTION
DIAGRAM
Earth
terminal
M
ø15
43
+
–
CK+
+ CK–
–
K
17
Electronics
unit
+ –
J
231
G1/2
Sensor
unit
Table 1
Conduit conn.
4th digit of the
code symbols
J
K
M
A, S
G1/2
17
8
B, T
1/2-14NPT
16
5
C, V
Pg13.5
8
4.5
D, W
M20×1.5
16
5
2-M8×12
11th digit of
Capillary
Code symbols length [mm]
D, Q
E, R
L, S
1500
3000
5000
70
120
16th digit of
Code symbols
17th digit of
Code symbols
50
Press. conn. “D”
S
R
Rc 1/2
S
N
1/2-14NPT
S
2
Rc 3/4
S
T
3/4-14NPT
11
FKW...4
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fesys.co.jp/eng
Instrumentation Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http://www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan