SMALL FLANGE LEVEL TRANSMITTER FKY...4 DATA SHEET The FCX–A2 small flange level transmitter accurately measures liquid level and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. FEATURES SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Static pressure, span, and range limit: Static pressure Type FKY 3 FKY 5 FKY 6 1. Directly connectable to 1-1/2 in. and 2 in. flanges The transmitter is connectable to 1-1/2 in. and 2 in. pipes without a reducer. 2. Minimum environmental influence The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART® bilingual communications protocol and FOUNDATION™ fieldbus and Profibus™ compatibility FCX–A2 series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–A2. Further, by upgrading electronics FOUNDATION™ fieldbus and Profibus™ are also available. 4. Application flexibility Various options that render the FCX–A2 suitable for almost any process applications include: – Analog indicator at either the electronics side or terminal side – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing – Wide selection of materials – High temperature, high vacuum service. 5. Programmable output Linearization Function Output signal can be freely programmable. (Up to 14 compensated points at approximation.) 6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA, Over Scale: 20.8 to 21.6mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. Up to flange rating Span limit [kPa] {m bar} Min. 3 {30} 13 {130} 50 {500} Max. 32 {320} 130 {1300} 500 {5000} Range limit [kPa] {m bar} +/– { +/– +/– { +/– +/– { +/– 32 320} 130 1300} 500 5000} Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower limit of static pressure (vacuum limit) ; Silicone fill sensor: See Fig.1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at temperature below 60 °C. – The maximum span of each sensor can be converted to different units using factors as below. 1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377psi 1kPa=10mbar=101.9716mmH2O=4.01463inH2O Overrange limit: To maximum static pressure limit Output signal: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. EDSX7-62k Date Apr. 1, 2007 FKY...4 Load limitations: see figure below Authorities Intrinsic safety [Ω] Load resistance 2000 ATEX 1533Ω 1500 Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.134mH 1000 600Ω Operating area 500 24V 250 0 10 16.1 10.5V Power voltage Factory Mutual 45V 50 Hazardous locations: ATEX A,B,D Y,G,H,S -40°C to +85°C Y,G,H,S -20°C to +80°C Q,S,4,5 Y,G,H,S -20°C to +60°C E,F,H Y,G,H,S -40°C to +60°C W,A,D -10°C to +60°C Entity Parameters: Vmax=42.4V, Imax=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH Flameproof Ex II 2 GD EEx d IIC T6 IP66/67 T85°C Tamb = -40°C to +65°C EEx d IIC T5 IP66/67 T100°C Tamb = -40°C to +85°C Factory Mutual Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F, G T6 Type 4X Tamb max = +60°C CSA - TIIS Ex do IIB+H2 T4 Tamb max = +55°C Maximum process temp.=+120°C IECEx Scheme /SAA Ex d IIC T5 IP66/67 pending Tamb = -40°C to +85°C Ex d IIC T6 IP66/67 pending Tamb = -40°C to +65°C Tamb L,P,1,2 - (Note) (1) HHC: Hand Held Communicator 2 Class I II III Div.1 Groups A, B, C, D, E, F, G T4 Entity Type 4X Model code 13th digit 9th digit [V] Note: For communication with HHC(1) (Model: FXW), min. of 250Ω required. Authorities Ex II 1 GD EEx ia IIC T5 Tamb = -40°C to +40°C EEx ia IIC T4 Tamb = -40°C to +80°C CSA Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F, G Class III Div.1 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Imax=93mA, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH TIIS Ex ia IIC T4 Tamb max = +60°C Entity Parameter: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=32.6nF, Li=1.134mH IECEx Scheme /SAA Ex ia IIC T4 IP66/67 Tamb = -40°C to +70°C Ex ia IIC T5 IP66/67 Tamb = -40°C to +50°C Entity Parameter: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=0.033µF, Li=1.034mH ATEX “Output Underscale”: Adjustable within the range 3.2mA to 3.8mA from HHC(1) Type n Nonincendive Authorities Ex II 3 GD EEx nL IIC T5 Tamb = -40°C to +40°C EEx nL IIC T4 Tamb = -40°C to +80°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=27nF, Li=1.134mH Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH 3.2 Normal operating range Under scale Probable under range Burnout Class I II III Div.2 Groups A, B, C, D, F, G T4 Entity Type 4X Model code 13th digit 9th digit CSA Tamb A,B,D Y,G,H,S -40°C to +85°C L,P,1,2 Y,G,H,S -20°C to +80°C Q,S,4,5 Y,G,H,S -20°C to +60°C E,F,H Y,G,H,S -40°C to +60°C W,A,D -10°C to +60°C - Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F, G Class III Div.2 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH TIIS - IECEx Scheme /SAA - 20 20.8 21.6 [mA] Over scale Burnout EEx nAL IIC T5 Tamb = -40°C to +40°C EEx nAL IIC T4 Tamb = -40°C to +80°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W, Model with arrester: Umax=32V, Imax=113mA, Pmax=1W Factory Mutual 3.8 4 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw (Span adjustment is not available with 9th digit code “L, P, Q, S”). Damping: Adjustable from HHC or local adjustment unit with LCD display. The time constant is adjustable between 0.12 to 32 seconds. Zero elevation/suppression: – 100% to + 100% of URL Normal/reverse action: Selectable from HHC(1) Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. “Output Overscale”: Adjustable within the range 20.8mA to 21.6mA from HHC(1) Probable over range Loop-check output: Transmitter can be configured to provide constant signal 3.8mA through 21.6mA by HHC(1). Temperature limit: Ambient: – 15 to + 65°C (– 15 to + 65°C for LCD indicator) (– 15 to + 60°C for arrester option) (– 10 to + 60°C for fluorinated oil fill transmitter) (– 10 to + 60°C for silicon oil “H”, “S”) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. Process: Fill fluid 13th digit of “Code symbols” Fluorinated oil W, A and D Silicone oil H Lower limit of static press Process temperature – 20 to 80°C Atmospheric 0 to 250°C pressure –40 to 120°C 2.7kPa abs 0 to 250°C {20.3mmHg abs} S Low pressure side contact liquid temperature on transmitter of Code H, S, is 120°C or lower. Y and G Storage: – 40 to + 70°C Humidity limit: 0 to 100% RH Communication: With HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely displayed or reconfigured. Note: HHC’s version must be more than 6.0 (or FXW 1– 3), for FCXA2. Items Display Set Tag No. v v Model No. v v Serial No. v — Engineering unit v v Range limit v — Measuring range v v Damping v v Output mode v — Burnout direction v v Calibration v v Output adjust — v Data v — Self diagnoses v — Printer — — External switch lock v v Transmitter display v v Linearize v v Rerange v v Programmable output linearization function: Output signal can be characterized with “14 points linear approximation function” from HHC(1). EMC Conformity: EN61326 3 FKY...4 Performance specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4-20 mA analog output in linear mode. Accuracy rating: (including linearity, hysteresis, and repeatability) (Standard) For spans greater than 1/10 of URL: ± 0.25% of span For spans below 1/10 of URL: ± 0.17 + 0.08 0.1 x URL Span ( ) % of span (Option) (Code: 21th digit H, K) For spans greater than 1/10 of URL: ± 0.1% of span For span below 1/10 of URL: ( ± 0.05 + 0.05 0.1 x URL Span ) % of span ± 0.2% of upper range limit (URL) for 3 years. Temperature effect: Effects per 28°C change between the limits of – 15°C and + 65°C Zero shift; ± 0.5%/28°C (x equal to 1/2 URL or more) URL Zero shift; ± 0.5 %/28°C 2x (x less than 1/2 URL) Total shift; ± 0.75%/28°C (x equal to 1/2 URL or more) URL Total shift; ± 0.25 +0.5 × %/28°C 2x (x less than 1/2 URL) Stability: ( ) ( ) (Option) (Code: 21th digit J, K) Zero shift; ± 0.5%/28°C (x equal to 1/6.5 URL or more) URL Zero shift; ± (0.5 %/28°C 6.5 x ) (x less than 1/6.5 URL) Total shift; ± 0.75%/28°C (x equal to 1/6.5 URL or more) URL Total shift; ± ( 0.25 +0.5 %/28°C 6.5 x ) (x less than 1/6.5 URL) Where, x: Calibrated span URL: Maximum span (Upper Range Limit) Static pressure effect: Zero shift: ± 0.2% of URL/1MPa Overrange effect:Zero shift; ± 0.1% of URL for flange rating pressure Supply voltage effect: Less than 0.005% of calibrated span per 1V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. (Classification: 2-abc: 0.2% span per SAMA PMC 33.1) Update period: 120 msec *) Step response: (without electrical damping) *) 4 Time constant *) Dead time *) 0.3 s 0.2 s Faster response is available as option (maximum update rate : 25 times per second) Mounting position effect: Zero shift, less than 0.3kPa{3m bar} for a 10° tilt in any plane. (No extension) No effect on span. This error can be corrected by adjusting zero. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Turn-on time: 4 sec Internal resistance for external field indicator: 12Ω or less Physical specifications Electrical connections: G 1/2 , 1/2 -14 NPT, Pg13.5, or M20 x 1.5 conduit, as specified. And 1-conduit or 2-conduit, as specified. Process connections: LP side: 1/4-18 NPT or Rc1/4. HP side: ANSI, or JIS raised face flange. See OUTLINE DIAGRAM for detailed dimensions. Refer to “Code symbols” Process-wetted parts material: LP side HP side Material code Wetted Diaphragm & Process (7th digit Diaphragm sensor body flange face cover in “Code symbols”) V 316 stainless 316L stainless 316 stainless 316L stainless (*1) J 316 stainless 316L stainless 316 stainless 316L stainless (*1) steel + AU coating 316 stainless 316L stainless 316 stainless Hastelloy-C C (*1) D 316 stainless 316L stainless 316 stainless Monel (*1) 316 stainless 316L stainless 316 stainless Tantalum E (*1) Hastelloy-C 316 stainless Hastelloy-C Hastelloy-C H lining (*1) Monel lining Monel M 316 stainless Monel (*1) Tantalum 316 stainless Tantalum Tantalum T lining (*1) Hastelloy-C Hastelloy-C Hastelloy-C Hastelloy-C B lining Monel lining Monel L Monel lining Monel Tantalum U Hastelloy-C Tantalum Tantalum lining Note: (*1) SCS14A per JIS G 5121 (equivalent CF8M per ASTM A351/A351M) Remark: Sensor O-rings: Viton O-ring or teflon gasket selectable Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating(standard), or 316 stainless steel (SCS14A per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard) or 304 stainless steel Fill fluid: Silicone oil (standard) or fluorinated oil Mounting flange: 304 stainless steel or carbon steel, as specified. Environmental protection: IEC IP67 and NEMA 6 / 6P Flange mounting:See drawings Mass{weight}: Transmitter approximately 13kg without options. Add; 0.8kg for indicator option 4.5kg for stainless steel housing option 1.0kg per 50mm extension of diaphragm Optional features Indicator: A plug-in analog indicator (2.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. An optional 5-digit LCD meter with engineering unit is also available. Local adjustment unit with LCD display: An optional 5-digit LCD meter with Zero/ Span adjustment function, loop-check function and damping adjustment function, is available. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity : 4kV (1.2 x 50µs). Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: Oil-free procedures as above. Includes fluorinated oil for fill. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. Vacuum service: Special silicone oil and filling procedure are applied. See Fig.1 Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell’s surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive. Filled liquid: Silicone (Code Y,G) [kPa abs] {m bar abs} Oval flanges: (Model FFP, refer to Data Sheet No. EDS6-10) Converts process connection to 1/2 -14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Hand held communicator: (Model FXW, refer to Data Sheet No. EDS 8-47) Z/S board: Parts No.=ZZPFCX4-A070 When Z/S board is mounted on the FCX– A2 amplifier unit, external adjustment screw will be available for zero and span adjustment. The product conforms to the requirements of the Electromagnetic compatibility Directive 94/9/EC as detailed within the technical construction file number TN513035. The applicable standards used to demonstrate compliance are : EMI (Emission) 53.3 {533} Operating area EN61326 : 1997 Class A (standard for Industrial Location) Frequency range MHz Limits Reference standard 30 to 230 40dB (µV/m) quasi peak, measured at 10m distance CISPR16-1 and CISPR16-2 230 to 1000 47dB (µV/m) quasi peak, measured at 10m distance EMI (Immunity) EN61326: 1997 Annex A (standard for Industrial Location) Phenomenon Electrostatic discharge Test value 4kV (Contact) 8kV (Air) Basic standard Performance criteria EN61000-4-2 B 80 to 1000MHz Electromagnetic 10V/m field 80%AM (1kHz) EN61000-4-3 A Rated power frequency magnetic field 30A/m 50Hz EN61000-4-8 A Burst 2kV 5kHz EN61000-4-4 B Surge 1.2µs/50µs 1kV (Line to line) 2kV (Line to ground) EN61000-4-5 B Conducted RF 0.15 to 80MHz 3V 80%AM (1kHz) EN61000-4-6 A Silicone (Code S) 101 {1010} Operating pressure ACCESSORIES Note) Definition of performance criteria A: During testing, normal performance within the specification limits. B: During testing, temporary degradation, or loss of function or performance which is self-recovering. 13.3 {133} Non-operating area 2.7 {27} –40 0 Fig. 1 60 85 120 200 230 250 [°C ] Process temperature Relation between process temperature and operating pressure 5 FKY...4 CODE SYMBOLS 1 2 3 4 5 6 7 8 Digit 4 5 6 7 <Connections> Process Conduit Oval flange connection connection screw 7/16-20UNF Rc1/4 (×1) G 1/2 1/4-18NPT 7/16-20UNF 1/2-14NPT (×1) 1/4-18NPT M10 (or M12) Pg13.5 (×1) 1/4-18NPT M10 (or M12) M20×1.5 (×1) 1/4-18NPT 7/16-20UNF Pg13.5 (×1) 7/16-20UNF G 1/2 Rc1/4 (×2) 1/4-18NPT 7/16-20UNF 1/2-14NPT (×2) 1/4-18NPT M10 (or M12) Pg13.5 (×2) 1/4-18NPT M10 (or M12) M20×1.5 (×2) 1/4-18NPT 7/16-20UNF Pg13.5 (×2) <Mounting flange> Material Size and rating 304 stainless JIS 10K 40A steel JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A ANSI/JPI 150LB 11/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 11/2" ANSI/JPI 300LB 2" Carbon steel JIS 10K 40A JIS 10K 50A JIS 20K 40A JIS 20K 50A JIS 30K 40A JIS 30K 50A ANSI/JPI 150LB 11/2" ANSI/JPI 150LB 2" ANSI/JPI 300LB 11/2" ANSI/JPI 300LB 2" <Span limit [kPa] {m bar}> 3 32 { 30 320} 13 130 {130 1300} 50 500 {500 5000} <Material> LP side Process cover Diaphragm Wetted sensor body 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel Hastelloy-C lining Monel lining Tantalum lining Note 1: (*1) 6 F KY Description 316 stainless steel 316 stainless steel 316 stainless steel Hastelloy-C Monel Tantalum Hastelloy-C Monel Tantalum 316 stainless steel 316 stainless steel 316 stainless steel Hastelloy-C lining Monel lining Tantalum lining Hastelloy-C lining Monel lining Tantalum lining Combination with 12th digit code "C, E, P, Q" are not available. 9 10 11 12 13 4 A B C D E S T V W X 0 1 2 3 4 5 A B C D G H J K L M Q R S T 3 5 6 HP side Diaphragm & flange face 316 stainless steel Diaphragm: 316L stainless steel +Au coating Flange face: 316 stainless steel Hastelloy-C Monel Tantalum Hastelloy-C Monel Tantalum Hastelloy-C Monel Tantalum V J C D E H M T B L U 100% turn down is possible for model FKY, but should be used within indicated span for better performance. 14 15 21 Digit No. of code 1 2 3 4 5 6 7 8 Digit 9 10 11 12 Description Note <Indicator and arrester> Indicator Arrester None None Analog, 0 to 100% linear scale None Z/S board Analog, custom scale None attached. None Yes Analog, 0 to 100% linear scale Yes Analog, custom scale Yes Digital, 0 to 100% None Digital, custom scale None Digital, 0 to 100% Yes Digital, custom scale Yes Digital, 0 to 100% (Local adjustment unit with LCD display) None Digital, custom scale (Local adjustment unit with LCD display) None Digital, 0 to 100% (Local adjustment unit with LCD display) Yes Digital, custom scale (Local adjustment unit with LCD display) Yes <Approvals for hazardous locations> None (for ordinary locations) TIIS, Flameproof (Conduit seal) (Available for 4th code "A","S") TIIS, Flameproof (Cable gland seal) (Available for 4th code "A","S") FM, Flameproof (or explosionproof) (Available for 4th code "B","T") ATEX, Flameproof IECEx Scheme/SAA, Flameproof (Approval pending) TIIS, Intrinsic safety FM, Intrinsic safety and nonincendive ATEX, Intrinsic safety ATEX, Type n IECEx Scheme/SAA, Intrinsic safety FM, Combined of Flameproof and Intrinsic safety <Diaphragm extension [mm]> Extension [mm] Applicable material code 0 Any 50 100 (7th digit code "V" only, 11/2 in. flange is not applicable) 150 200 <Options> Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None Yes (*2) Yes None Note 2 None None Yes Yes None Yes None Yes Yes Yes Yes Yes Note 2: (*2) F KY 9 10 11 12 13 14 15 4 21 Digit No. of code A B D E F H L P Q S 1 2 4 5 A B C D X R G H K P T V Y A B C D Y B C E M N P Q Customer tag number can be engraved on standard stainless steel name plate. If extra tag plate is required, select "Yes". 7 FKY...4 1 2 3 4 5 6 7 8 Digit 13 14 15 21 Description Note <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code "V" only) Chlorine service Fluorinated oil (7th digit code "H", "T", "B", "U", "C" and "E") High temp. 250°C Silicone oil (7th digit code "V", "H") High temp. and vacuum (250°C) Silicone oil (7th digit code "V" only) <O-ring / Gasket and Teflon membrane> O-ring / Gasket Teflon membrane Viton (O-ring) None Teflon (gasket) None Viton (O-ring) Yes (11th digit code "Y" only) Teflon (gasket) Yes (13th digit code "H", "S" are not available.) <Bolt/nut> (*3) Note 3 Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut 304 stainless steel bolt / 304 stainless steel nut <Other options> (*4) Note 4 High accuracy type Instruction manual attached Low temperature effect type Instruction manual attached H+J Instruction manual attached Instruction manual unattached High accuracy type Instruction manual unattached Low temperature effect type Instruction manual unattached T+U Instruction manual unattached Note 3: (*3) In case of tropical use, select stainless bolts and nuts. Note 4: (*4) If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. 8 F KY 9 10 11 12 13 14 15 21 4 Y W G A D H S A B C D A B E H J K L T U V Digit No. of code ORDERING INFORMATION When ordering this instrument, specify: 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occurred in the transmitter. Hold / Overscale (21.6mA) / Underscale (3.2mA). Unless otherwise specified, output hold function is supplied. 4. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S on 9th digit). 5. TAG No. (up to 26 alphanumerical characters), if required. 9 FKY...4 OUTLINE DIAGRAM (Unit:mm) < 7th digit code : "V", "J", "C" , "D", "E", "H", "M"or "T" > Vent / drain plug (When the vent / drain plug attatched on the upper side of the detector) In case of 4th digit code "T" In case of 4th digit code "S.V.W.X" In case of 4th digit code "A.B.C.D.E" In case of frange with 4 bolt holes Fastener (Flameproof only) 105 ø80 52.5 105 UP ø80 43.5 94.5 8 10 "A" L. P. conn. DOWN 88 N holes h dia. 2 "C" Conduit conn. Zero ADJ. screw (27) 1 Note) Vent / drain plug "B" Conduit conn. Cable gland (option) With field ind. Long vent/drain p lug (Option) t L.P. conn. 41.3 Oval flange screw See table 1 Detail "A" Detail "B" Sensor unit + – CK+ + CK– – 10 t N-øh Flange 4th digit of the code symbols Y 0 A 50 B 100 10.5 to 17.5 C 150 11 D 200 11.5 to 18.5 Conduit conn. J K 9.5 to 12 10 H G1/2 17 8 Rc1/4 4-19 JIS-10K-50A B, T 1/2-14NPT 18 5 1/4-18NPT 4-19 JIS-20K-40A C, V Pg13.5 8 4.5 1/4-18NPT D, W M20 16 5 1/4-18NPT E, X Pg13.5 8 4.5 1/4-18NPT 4-19 JIS-10K-40A 1, H 155 120 36 2, J 140 105 39 3, K 155 120 38 8-19 JIS-20K-50A 4, L 160 120 42 4-23 JIS-30K-40A 5, M 165 130 42 8-19 JIS-30K-50A A, Q 127 B, R 152 120.6 39.5 4-20 ANSI/JPI-150-2B 98.4 37.5 4-16 ANSI/JPI-150LB-1 1/2B C, S 156 114.3 41 D, T 165 127 42.5 8-20 ANSI/JPI-300LB-2B 4-23 ANSI/JPI-300LB-1 1/2B Cable gland is supplied in case offlamproof packing type. ø11 cable is suitable. 15 Table 1 1 2 3 333 160 296 to 17 327 154 290 to 18 Press. conn. M A, S 140 105 36 Note) G1/2 11th digit of L Mass approx, [kg] Code symbols [mm] + – 0, G J Electronics unit CONNECTION DIAGRAM øE K 8 H ø18.5 3 Inner of gasket øD ø13 M Earth terminal 2.5 43 143 27 øD øE ø84 ø49 ø48 H.P. conn 5th digit of Code symbols ø15 48 ø7 Detail "C" 17 L 20 Oval flange screw 7/16-20UNF SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 M10 SCREW DEPTH15 M10 SCREW DEPTH15 7/16-20UNF SCREW DEPTH15 < 7th digit code : "B", "L" or "U" > Oval flange screw See Table 1 In case of 4th digit code "T" Fastener (Flameproof only) N holes h dia. 10 8 "A" or "B" L. P. conn. 41.3 In case of 4th digit code "S.V.W.X" 94.5 In case of flange with 4 bolt holes In case of 4th digit code "A.B.C.D.E" ø80 105 107 ø80 52.5 105 Up 88 Down 150 Note) Vent / drain plug Cable gland (option) (27) 323 Zero ADJ. screw "C" Conduit conn. 1 "D" Conduit conn. With field ind. t 20 Details of "A" 4th of code symbols "A, S" type ø16 Details of "B" 4th of code symbols "B, C, D, E, T, V, W, X" type ø16 1/4-18NPT 0.1 2–0.1 –0.2 0.2 0 ø12+0.1 10 1 øD øE ø84 ø49 40.5 43 91 186 H.P. conn 286 Inner of gasket ø4 Earth terminal Electronics unit Details of "C" Details of "D" ø13 ø15 – CK+ CK– K + M CONNECTION DIAGRAM 17 Sensor unit + – J G1/2 See table 1 5th digit of Code øD symbols øE t 140 105 36 4-19 JIS-10K-40A 1, H 155 120 36 2, J 140 105 39 3, K 155 120 38 8-19 JIS-20K-50A 0, G N-øh Flange K M A, S G1/2 17 8 4-19 JIS-10K-50A B, T 1/2-14NPT 16 5 4-19 JIS-20K-40A C, V Pg13.5 8 4.5 D, W M20 16 5 E, X Pg13.5 8 4.5 4, L 160 120 42 4-23 JIS-30K-40A 165 130 42 8-19 JIS-30K-50A A, Q 127 B, R 152 120.6 39.5 4-20 ANSI/JPI-150-2B C, S 158 114.3 41 4-23 ANSI/JPI-300LB-1 1/2B D, T 165 8-20 ANSI/JPI-300LB-2B Note) 127 42.5 Conduit conn. J 5, M 98.4 37.5 4th digit of the code symbols 4-16 ANSI/JPI-150LB-1 1/2B 15 Oval flange screw 7/16-20UNF SCREW DEPTH10 7/16-20UNF SCREW DEPTH10 M10 SCREW DEPTH10 M10 SCREW DEPTH10 7/16-20UNF SCREW DEPTH10 Table 1 Cable gland is supplied in case of flamproof packing type. ø11 cable is suitable. 11 FKY...4 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan