FUJI EDS9-44E

FFI SYSTEM
OPTICAL SIGNAL CONVERTER
DATA SHEET
FRK
The optical signal converter performs conversion between optical and electrical signals of FFI system specifications, and serves as an interface when connecting a
detector or controlled element of an electronic instrumentation system to the FFI system.
This is a high-precision intelligent instrument with a
built-in microcomputer for digital processing of signals.
Optical fiber is used in the signal transmission section
which enables forming an optical fiber type field instrumentation system (FFI system) together with optical
star coupler and master station.
FEATURES
1. Bidirectional transmission system
Transmission of measured data and fault diagnosis
data to the host computer and remote settings etc.
from the host is done bidirectionally via a signal optical
fiber cable.
2. Easy adjustment and setting operation
Adjustment and settings can be made easily via remote
operation from the host computer or by key switches
on the indicating unit (option).
3. Self-diagnosis function
A number of self-diagnoses are possible by the builtin microcomputer.
4. Digital display type field indicator available at option.
5. Flame-proof structure (d2G4) can be provided at
option.
SPECIFICATIONS
Functional Specifications
Optical/electrical conversion output signal:
4 to 20mA DC (allowable load 600Ω)
Electrical/optical conversion input signal:
1 to 5V DC (input resistance 1MΩ or
more)
4 to 20mA DC (input resistance 150Ω
or less) (None)
10 to 50mA DC (input resistance 80Ω
or less)
Note) The power for a 2-wire type
transmitter and converter for 4 to 20mA
DC can also be supplied
(supply voltage about 20V DC).
Power supply:
24V DC (20 to 30V) or 24, 100, 115,
220V AC (± 10%), 50/60Hz
Power consumption:
About 4W (DC power supply) or about 8VA
(AC power supply)
Setting:
• Damping time constant up to 17 sec
• Optical/electrical conversion output
0% and 100% calibration, readback
0% and 100% calibration
• Electrical/optical conversion output
0% and 100% calibration
Self-diagnosis: • Input overflow/underflow, microcomputer fault, battery down (for
memory backup)
• Optical/electrical D/A converter fault
• External line disconnection fault
Display (option): • Optical/electrical converter readback
value (0 to 100%)
• Electrical/optical conversion input value
(0 to 100%)
• Symbols and numerals for above setting
items
• Symbols for above diagnosis items …
only at fault occurrence
But microcomputer fault is not displayed
since it is normalized through auto reset
action.
Ambient temperature:
–20 to 60°C
Ambient humidity:
95% R.H. or less
Transmission:
Half-duplex bidirectional transmission
with one-fiber system
Transmission distance; 1.2 km max.
EDS9-44e
Date
Dec. 30, 1987
FRK
Other:
Optical output alone can be provided by
combining the electrical/optical converter
with an optical receiving converter (type
PRN).
In this case the transmission distance is
4 km max.
Performance Specifications
Accuracy rating: ± 0.2%
Repeatability:
± 0.1%
Ripple content: 1% P–P (optical electrical converter output
current)
Insulation:
(in arrester exclusion status)
Between power supply and signals
Insulation resistance; 500MΩ or more
(with 500V DC megger)
Withstand voltage; 1000V AC for 1
minute
Between power supply and ground
Insulation resistance; 500MΩ or more
(with 500V DC megger)
Withstand voltage; 1000V AC for 1
minute
Between signals and ground
Insulation resistance; 500MΩ or more
(with 500V DC megger)
Withstand voltage; 500V AC for 1 minute
Structure and Material
Finish:
Epoxy/polyurethane double coating, silver
(cover; blue)
Enclosure:
JIS C 0920 immersion-proof
(equivalent to IEC IP65 or NEMA 4)
Outer dimensions (H x W x D) and Mass (weight):
161 x 172 x 212 (240) mm, about 4.0 kg
Parenthesized dimension is when display
unit equipped.
Mounting method:
Mounted by U bolt on horizontal or
vertical 50A (2B) pipe, or wall mounted
Cable and connection method:
JIS G1/2 internal thread
(Terminals: M4 screw)
Optical fiber cable is Fuji-specified one
(prepare separately)
Connection is made by optical connector.
Optical Specifications
Indication unit:
6-digit LCD unit with setting key
(4 pushbutton switches)
Acid and alkali-proof treatment:
Mounting U bolt and nuts material:
SUS304
CODE SYMBOLS
1 2 3 4 5 6 7 8
FRK
9 10 11
Description
1 -
Kind
Optical/electrical conversion
Electrical/optical conversion
Electrical/optical conversion
transmitter power supply built in
1
2
3
Input/output signals
FFI optical signal/4 to 20mA DC (unusable with 2, 3 in 4th digit)
1 to 5V DC/ FFI optical signal (unusable with 1, 3 in 4th digit)
4 to 20mA DC/ FFI optical signal (unusable with 1 in 4th digit)
10 to 50mA DC/ FFI optical signal (unusable with 1, 3 in 4th digit)
Y
A
B
C
Indicating unit
None
Equipped
A
B
Power supply
24V DC
24V AC, 50/60Hz
100V AC, 50/60Hz
115V AC, 50/60Hz
220V AC, 50/60Hz
1
2
3
4
5
Arrester
None
Equipped
0
2
Enclosure
Immersion-proof case, non-explosion-proof
Flame-proof case (conduit flame-proof screw coupling type)
Flame-proof case (flame-proof packing type)
1
3
4
Y
B
2
Treatment
None
Acid/alkali-proof processing
OUTLINE DIAGRAM (Unit : mm)
Indicating unit
(optional specification)
(28)
172
212
109
119
Conduit cnnection
(See "Details of A")
53
161
60
108
ø105
Optical connection
ø45
Indicating unit
(optional specification)
Pipe mouting
Details of A
73
ø15
16
173
152
5
129
G1/2 (JIS)
M8 U bolt
Mounting pipe JIS50A (2B)
Wall mouting
100
152
47
70
3
FRK
OPERATING PRINCIPLE DIAGRAM
Optical/electrical converter
Indicating unit (option)
Display
Setting
Optical connector
Optical unit
µ-Com
Output
circuit
DC 4 to 20mA
Readback
circuit
Electrical/optical converter
Display unit (option)
Display
Setting
Optical connector
Optical unit
µ-Com
Input circuit
DC 1 to 5V
4 to 20mA
10 to 50mA
SYSTEM BLOCK DIAGRAM
Signal converter
FRK
Optical fiber,
8 lines max.
Optical star
coupler FXN
Optical fiber,
4 lines max.
Master station
PMT,PMH
Electrical signal
Electrical signal
Power supply
Power supply
Signal converter(E/O)
FRK
Optical
receiving
converter
PRN
2
3
Optical fiber cable
Electrical signal
Power supply
4
Output signal
DC 1 to 5V
or
DC 4 to 20mA
Power supply
EXTERNAL CONNECTION DIAGRAM
Optical/electrical converter
Electrical/optical converter
Power supply
CK
PC
PS
O+
O-
Power supply
CK
PC
PS
I-
I+
Current check
terminal
(Note 1)
DC 4 to 20mA
DC 10 to 50mA
DC 4 to 20mA
Current check terminal
(Note 2)
DC 1 to 5V
Note 1. O/E converter current can be checked at the CK (check)
terminal and "0+" terminal
Connect the "+" side of the check current ammeter
(Internal resistance is less than 10Ω) to CK and the
"–" side to "+0".
2. E/O converter current input can be checked at CK and
I – terminals. Connect the "+" side of the check current
ammeter to CK and the "–" side to I –.
(Internal resistance of 4 to 20mA check current ammeter
is less than 10Ω and that of 10 to 50mA check current
ammeter is less than 4Ω).
SCOPE OF DELIVERY
Converter and mounting bracket
RELATED DEVICES
•
•
•
•
•
•
Master station (Data sheet No. EDS11-86)
Optical star coupler (Data sheet No. EDS8-43)
Optical receiving converter (Data sheet No. EDS9-43)
Optical connector
Optical fiber cable
Optical connector assembling tools
5
FRK
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
http://www.fesys.co.jp/eng
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http: //www.fic-net.jp/eng
Information in this catalog is subject to change without notice.
Printed in Japan