FC SERIES PT TYPE DISTRIBUTOR (24mm width) DATA SHEET PTM The FC series PT type distributor converts a current signal (4 to 20mA DC) from transmitter into a voltage signal (1 to 5V DC) and distributes the voltage signal to each receiver. In addition, this distributor is provided with built-in transmitter power suppy. Its structure is plug-in style. SPECIFICATIONS INPUT SPECIFICATION Input signal: 1 point Input type Current Input signal 4 to 20mA DC Input resistance 250Ω OUTPUT SPECIFICATION Output signal: 1 point Output type Voltage Output signal 1 to 5V DC Allowable load 500kΩ or over resistance (reception, non-insulation) 15kΩ or over (with output buffer) POWER SUPPLY Power supply: 24V DC (20 to 30V DC) 24V AC, +13%, –10%, (47 to 63Hz) as specified. Power consumption: Approx. 2W OPERATION CONDITION Ambient temperature: 0 to 50°C Ambient humidity:Less than 90%RH (no condensation) Outline dimension (HxWxD): 96 x 26 x 130mm Mass: Appox. 200g Housing: Plastic housing (color: black) Mounting method: Panel mounting or DIN rail mounting CHARACTERISTICS Accuracy: Less than ± 0.1% of full span Response time: Less than 0.1 sec. (90% response) Dielectric strength: 1500V AC, 1 min. Reception only: Input • Output - Ground Non-insulation type: Input • Output • Power- Ground Non-insulation with buffer: Input • Output • Power- Ground Power insulation with buffer: Input • Output - Power- Ground Power I/O insulation with buffer: Input - Output - Power- Ground Insulation resistance: 500V DC, 100MΩ or over Reception specified: Input • Output - Ground Non-insulation type: Input • Output • Power- Ground Non-insulation with buffer: Input • Output • Power- Ground Power insulation with buffer: Input • Output - Power- Ground Power I/O insulation with buffer: Input - Output - Power- Ground Ambient temperature effect: Less than ± 0.15% of full span / 10°C Power regulation effect: Less than ± 0.1% of full span CODE SYMBOLS 1 2 3 4 5 6 7 8 P TM2 V Description 1 Input signal 4 to 20mA DC 2 Output signal 1 to 5V DC V A0 B1 C1 D1 E1 Output system Reception only Non-insulation type Non-insulation with buffer Power insulation with buffer Power I/O insulation with buffer Power supply None 24V DC 24V DC 24V DC/ 24V AC (50/60Hz) 24V DC/ 24V AC (50/60Hz) EDS9-25a Date Feb. 20, 1996 PTM FUNCTIONAL DIAGRAM 1. Reception only type 2. Non-insulation type 11 31 Output Transmitter (4 to 20mA DC) 12 11 32 250Ω Transmitter (4 to 20mA DC) 21 31 Current limiting Output 12 32 250Ω 21 41 22 22 42 3. Power insulation type with buffer 11 Transmitter (4 to 20mA DC) 4. Power input/output insulation type with buffer 31 Current limiting 11 Output 12 32 21 41 Power circuit 22 42 Transmitter (4 to 20mA DC) 31 Current limiting Output 12 Terminal screw M4 42 Power supply EXTERNAL CONNECTION DIAGRAM Terminal screw (for transmission) Main unit Reception only type 35 74 + 94 41 Power circuit 22 250Ω OUTLINE DIAGRAM (Unit: mm) Terminal 2 100 26 Stopper 130 Panel mounting 32 Signal insulation circuit 21 Power supply 250Ω 24 Power supply DIN rail mounting - General + - 11 12 + - 11 12 + - 21 22 21 22 5 5 6 6 31 32 + - 31 32 + - OUTPUT OUTPUT 41 42 41 42 + POWER 2-M4 DIN rail RANGE OF DELIVERY Main unit and socket 16 26 Stopper Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan