PRESSURE TRANSMITTER FKG...4 DATA SHEET The FCX – A2 pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. FEATURES 1. High accuracy ±0.07% 0.07% accuracy is a standard feature. Fuji’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advance Floating Cell” design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 3. Fuji/HART ® bilingual communications protocol and FOUNDATION™ fieldbus and Profibus™ compatibility FCX–A2 series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any HART® compatible devices can communicate with FCX–A2. Further, by upgrading electronics FOUNDATION™ fieldbus and Profibus™ are also available. 4. Application flexibility Various options that render the FCX – A2 suitable for almost any process applications include: – Analog indicator at either the electronics side or terminal side – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing 5. Burnout current flexibility (Under Scale: 3.2 to 3.8mA, Over Scale: 20.8 to 21.6mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 6. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. SPECIFICATIONS Functional specifications Service: Liquid, gas, or vapour Span, range and overrange limit: Span limit [kPa] {bar} Type F KG 01 F KG 02 F KG 03 F KG 04 F KG 05 Range limit [kPa] {bar} Min. Max. Lower limit Upper limit 1.3 {0.013} 5 {0.05} 30 {0.3} 100 {1} 500 {5} 130 {1.3} 500 {5} 3000 {30} 10000 {100} 50000 {500} –100 {–1} –100 {–1} –100 {–1} –100 {–1} –100 {–1} 130 {1.3} 500 {5} 3000 {30} 10000 {100} 50000 {500} Overrange limit [MPa] {bar} 1 {10} 1.5 {15} 9 {90} 15 {150} 75 {750} Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower range limit (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at below 60°C – Conversion factors to different units; 1 MPa=103 kPa=10bar=10.19716kgf/cm2= 145.0377psi 1kPa=10mbar=101.9716mmH2O =4.01463inH2O Output signal: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal. EDSX5-80k Date Mar. 7, 2007 FKG...4 Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. Load limitations: see figure below Authorities ATEX Load resistance 1533Ω 1500 Factory Mutual 1000 600Ω 24V 250 0 10 16.1 10.5V Power voltage 45V 50 [V] Class I Div.1 Groups A, B, C, D Class II Div.1 Groups E, F, G Class III Div.1 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Imax=93mA, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH TIIS Ex ia IIC T4 Tamb max = +60°C Entity Parameters: Ui=28V, Ii=94.3mA, Pi=0.66W, Ci=32.6nF, Li=1.134mH IECEx Scheme /SAA Ex ia IIC T4 IP66/67 Tamb = –40°C to +70°C Ex ia IIC T5 IP66/67 Tamb = –40°C to +50°C Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=0.033µF, Li=1.034mH Flameproof ATEX Ex II 2 GD EEx d IIC T6 IP66/67 T85°C Tamb = – 40°C to +65°C EEx d IIC T5 IP66/67 T100°C Tamb = – 40°C to +85°C Factory Mutual Class I Div.1 Groups B, C, D T6 Type 4X Class II III Div.1 Groups E, F, G T6 Type 4X Tamb max = +60°C CSA Class I Div.1 Groups C, D Class II Div.1 Groups E, F, G Class III Div.1 TIIS Ex do IIB+H2 T4 Tamb max = +55°C Maximum process temp. = +120°C IECEx Scheme /SAA Ex d IIC T5 IP66/67 pending Tamb = – 40°C to +85°C Ex d IIC T6 IP66/67 pending Tamb = – 40°C to +65°C Note) “Seal Not Required” enclosure is allowed. 2 Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C –10°C to +60°C CSA Hazardous locations: Authorities 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Entity Parameters: Vmax=42.4V, Imax=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH Note: For communication with HHC (1) (Model: FXW), min. of 250 Ω required. Class I II III Div.1 Groups A, B, C, D, E, F, G T4 Entity Type 4X Model code 9th digit A,B,D L,P,1,2 Q,S,4,5 E,F,H – Operating area 500 Ex II 1 GD EEx ia IIC T5 Tamb = –40°C to +40°C EEx ia IIC T4 Tamb = –40°C to +80°C Entity Parameters: Ui=28V, Ii=93.3mA, Pi=0.66W, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.134mH [Ω] 2000 Intrinsic safety ATEX “Output Overscale”: Adjustable within the range 20.8mA to 21.6mA from HHC(1) “Output Underscale”: Adjustable within the range 3.2mA to 3.8mA from HHC Type n Nonincendive Authorities Ex II 3 GD EEx nL IIC T5 Tamb = –40°C to +40°C EEx nL IIC T4 Tamb = –40°C to +80°C Specific Parameters: Model without arrester: Ui=42.4V, Ii=113mA, Pi=1W, Ci=27nF, Li=1.134mH Model with arrester: Ui=32V, Ii=113mA, Pi=1W, Ci=34.2nF, Li=1.134mH 3.2 Normal operating range Under scale Probable under range Burnout Class I II III Div.2 Groups A, B, C, D, F, G T4 Entity Type 4X Model code 9th digit A,B,D L,P,1,2 Q,S,4,5 E,F,H – 13th digit Y,G,N,R Y,G,N,R Y,G,N,R Y,G,N,R W,A,D Tamb –40°C to +85°C –20°C to +80°C –20°C to +60°C –40°C to +60°C –10°C to +60°C CSA Class I Div.2 Groups A, B, C, D Class II Div.2 Groups E, F, G Class III Div.2 Temp Code T4 Tamb max = +40°C Temp Code T3C Tamb max = +85°C Entity Parameters: Vmax=28V, Ci=27nF (Without Arrester), Ci=34.2nF (With Arrester), Li=1.4mH TIIS – IECEx Scheme /SAA – 20 20.8 21.6 [mA] Over scale Burnout EEx nAL IIC T5 Tamb = –40°C to +40°C EEx nAL IIC T4 Tamb = –40°C to +80°C Specific Parameters: Model without arrester: Umax=42.4V, Imax=113mA, Pmax=1W Model with arrester: Umax=32V, Imax=113mA, Pmax=1W Factory Mutual 3.8 4 Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code “L, P, Q, S”). Damping: Adjustable from HHC or local adjustment unit with LCD display. The time constant is adjustable between 0.12 to 32 seconds. Zero elevation/suppression: Zero can be elevated or suppressed within the specified range limit of each sensor model. Normal/reverse action: Selectable from HHC(1). Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable from HHC(1) If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale” or “Output Underscale” modes. “Output Hold”: Output signal is hold as the value just before failure happens. Probable over range Loop-check output: Transmitter can be configured to provide constant signal 3.8mA through 21.6mA by HHC. Temperature limit: Ambient: – 40 to +85°C (–20 to +80°C for LCD indicator) (– 40 to +60°C for arrester option) (–10 to +60°C for fluorinated oil fill transmitter) For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. Process: – 40 to +100°C for silicone fill sensor –20 to +80°C for fluorinated oil fill sensor Storage: –40 to +90°C Humidity limit: 0 to 100% RH Communication: With HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following information can be remotely displayed or reconfigured. Note: HHC’s version must be more than 6.0 (or FXW 1– 3), for FCXA2. Items Display Set Tag No. v v Model No. v v Serial No. v — Engineering unit v v Range limit v — Measuring range v v Damping v v Output mode v — Burnout direction v v Calibration v v Output adjust — v Data v — Self diagnoses v — Printer — — External switch lock v v Transmitter display v v Linearize v v Rerange v v EMC Conformity:EN61326 (Note) (1) HHC: Hand Held Communicator 3 FKG...4 Performance specifications Physical specifications Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode. Accuracy rating: (including linearity, hysteresis, and repeatability) Max span below 10000kPa model: For spans greater than 1/10 of URL: ± 0.07% of span For spans below 1/10 of URL: 0.1 × URL ± 0.02+0.05 % of span Span Max span 50000kPa model: For spans greater than 1/10 of URL: ± 0.1% of span For spans below 1/10 of URL: 0.1 × URL ± 0.05+0.05 % of span Span Stability: ± 0.1% of upper range limit (URL) for 3 years. Temperature effect: Effects per 28°C change between the limits of –40°C and +85°C URL Zero shift: ± (0.075+0.0125 span )% URL Total effect: ± (0.095+0.0125 span )% Overrange effect: Zero shift; 0.2% of URL for any overrange to maximum limit Supply voltage effect: Less than 0.005% of calibrated span per 1V RFI effect: Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength 30 V/m when electronics covers on. (Classification: 2-abc: 0.2% span per SAMA PMC 33.1) Update period: 120 msec *) Step response: Time constant: 0.2s *) Dead time: approximately 0.2s *) (without electrical damping) ( ( ) ) *) Faster response is available as option (maximum update rate: 25 times per second). Mounting position effect: Zero shift, less than 0.1kPa {1m bar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MΩ at 500V DC. Turn-on time: 4 sec. Internal resistance for external field indicator: 12Ω or less 4 Electrical connections: G1 /2, 1/2-14 NPT, Pg13.5, or M20 × 1.5 conduit, as specified. 1-port (standard) or 2-port with each conduit, as spcified. Process connections: 1/4-18 NPT or Rc1/4 on 54mm centers, as specified. Meet DIN 19213 Process-wetted parts material: Material code (7th digit Process cover in Code symbols) V J H M T B L U 316 stainless steel(*1) 316 stainless steel(*1) Diaphragm 316L stainless steel 316L stainless steel +Au coating 316 stainless Hastelloy-C steel(*1) 316 stainless Monel steel(*1) 316 stainless Tantalum steel(*1) Hastelloy-C Hastelloy-C lining Monel lining Monel Tantalum Tantalum lining Wetted sensor body Vent/drain 316 stainless steel 316 stainless steel 316/316L stainless steel 316/316L stainless steel Hastelloy-C lining Monel lining 316/316L stainless steel 316/316L stainless steel 316/316L stainless steel Hastelloy-C Tantalum lining Hastelloy-C lining Monel lining Tantalum lining Monel Hastelloy-C Note: (*1) SCS14A per JIS G 5121 (equivalent CF8M per ASTM A351/A351M) Remarks: Sensor O-rings: Viton O-ring and teflon gasket selectable Availability of above material design depends on ranges. Refer to “Code symbols”. Non-wetted parts material: Electronics housing: Low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating (standard), or 316 stainless steel (SCS14A per JIS G5121), as specified. Bolts and nuts: Cr-Mo alloy (standard), or 304 stainless steel (630 stainless steel for 50MPa unit). Fill fluid: Silicone oil (standard) or fluorinated oil Mounting bracket: 304 stainless steel Environmental protection: IEC IP67 and NEMA 6/6P Mounting: On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting, or direct process mounting. Mass {weight}: Transmitter approximately 3.4kg without options. Add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option ACCESSORIES Optional features Indicator: A plug-in analog indicator (2.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. An optional 5-digit LCD meter with engineering unit is also available. Local adjustment unit with LCD display: An optional 5-digit LCD meter with Zero/ Span adjustment function, loop-check function and damping adjustment function, is available. Arrester: A built-in arrester protects the electronics from lightning surges. Lightning surge immunity: 4kV (1.2 × 50µs) Oxygen service: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. The fill fluid is fluorinated oil. Chlorine service: The fill fluid is fluorinated oil. Degreasing: Process-wetted parts are cleaned, but the fill fluid is standard silicone oil. Not for use on oxygen or chlorine measurement. NACE specification: Metallic materials for all pressure boundary parts comply with NACE MR-01-75. ASTM B7M or L7M bolts and 2HM nuts (Class II) are available. Vacuum service: Special silicone oil and filling procedure are applied. See Fig.1. Optional tag plate: An extra stainless steel tag with customer tag data is wired to the transmitter. Coating of cell: Cell’s surface is finished with epoxy/polyurethane double coating. Specify if environment is extermely corrosive. Silicone oil (Code:Y,G,N) Oval flanges: (Model FFP, refer to Data Sheet No. EDS6-10) Converts process connection to 1 /2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel. Hand-held communicator: (Model FXW, refer to Data Sheet No. EDS8-47) Z/S board: Parts No.=ZZPFCX4-A070 When Z/S board is mounted on the FCX– A2 amplifier unit, external adjustment screw will be available for zero and span adjustment. The product conforms to the requirements of the Electromagnetic compatibility Directive 94/9/EC as detailed within the technical construction file number TN513035. The applicable standards used to demonstrate compliance are : EMI (Emission) Frequency range MHz Limits Reference standard 30 to 230 40dB (µV/m) quasi peak, measured at 10m distance CISPR16-1 and CISPR16-2 230 to 1000 47dB (µV/m) quasi peak, measured at 10m distance EMI (Immunity) Operating pressure Operating area 20 {200} EN61326: 1997 Annex A (standard for Industrial Location) Phenomenon Electrostatic discharge Test value 4kV (Contact) 8kV (Air) Basic standard Performance criteria EN61000-4-2 B 80 to 1000MHz Electromagnetic 10V/m field 80%AM (1kHz) EN61000-4-3 A Rated power frequency magnetic field 30A/m 50Hz EN61000-4-8 A Burst 2kV 5kHz EN61000-4-4 B Surge 1.2µs/50µs 1kV (Line to line) 2kV (Line to ground) EN61000-4-5 B Conducted RF 0.15 to 80MHz 3V 80%AM (1kHz) EN61000-4-6 A Silicone oil (Code:R) [kPa abs] {mbar abs} 101 {1010} EN61326 : 1997 Class A (standard for Industrial Location) Note) Definition of performance criteria A: During testing, normal performance within the specification limits. B: During testing, temporary degradation, or loss of function or performance which is self-recovering. 4 {40} 2.7 {27} None-operating area –40 –15 60 85 120 Process temperature[°C ] Fig. 1 Relation between process temperature and operating pressure 5 FKG...4 CODE SYMBOLS 1 2 3 4 5 6 7 8 Digit 4 6, 7 9 <Connections> Oval flange Process screw connection 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF 7/16-20UNF Rc1/4 1/4-18NPT 7/16-20UNF 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT M10 (or M12)(*1) 1/4-18NPT 7/16-20UNF <Span and materials> Process cover Span limit [kPa]{bar}(*2) 316 stainless steel 1.3…130 316 stainless steel {0.013…1.3} 5…500 {0.05…5} 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 30…3000 {0.3…30} 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 100…10000 {1…100} 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 500…50000 {5…500} 316 stainless steel 316 stainless steel 316 stainless steel Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel Conduit connection G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 G1/2 1/2-14NPT Pg13.5 M20×1.5 Pg13.5 (×1) (×1) (×1) (×1) (×1) (×2) (×2) (×2) (×2) (×2) Combination with 12th digit code "C, E, P, Q" are not available. Note 1 Note 1 Note 1 Note 1 F KG 0 9 10 11 12 13 4 A B C D E S T V W X Diaphragm Wetted cell body 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating Hast. C Monel Tantalum Hast. C Monel Tantalum 316L stainless steel 316L stainless steel +Au coating 316 stainless steel 316 stainless stee 1V 1J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless stee 1H 1M 1T 1B 1L 1U 2V 2J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless stee 2H 2M 2T 2B 2L 2U 3V 3J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 3H 3M 3T 3B 3L 3U 4V 4J Hast. C lining Monel lining Tantalum lining Hast. C lining Monel lining Tantalum lining 316 stainless steel 316 stainless steel 4H 4M 4T 4B 4L 4U 5V 5J Note 2 <Indicator and arrester> Indicator None Analog, 0 to 100% linear scale Analog, custom scale None Analog, 0 to 100% linear scale Analog, custom scale Digital, 0 to 100% Digital, custom scale Digital, 0 to 100% Digital, custom scale Digital, 0 to 100% (Local adjustment unit with LCD display) Digital, custom scale (Local adjustment unit with LCD display) Digital, 0 to 100% (Local adjustment unit with LCD display) Digital, custom scale (Local adjustment unit with LCD display) Note 1 : (*1) Note 2 : (*2) 6 Note Description Arrester None None Z/S board None attached. Yes Yes Yes None None Yes Yes A B D E F H L P Q S 1 None 2 None 4 Yes 5 Yes For 50MPa {500bar} units, M12 is provided rather than M10. 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance. 14 15 21 Digit No. of code 1 2 3 4 5 6 7 8 Digit 10 11 12 13 14 15 21 Description Note <Approvals for hazardous locations> None (for ordinary locations) TIIS, Flameproof (Conduit seal) (Available for 4th digit code "A", "S") TIIS, Flameproof (Cable gland seal) (Available for 4th digit code "A", "S") FM, Flameproof (or explosionproof) (Available for 4th digit code "B", "T") CSA, Flameproof (or explosionproof) (Available for 4th digit code "B", "T") ATEX, Flameproof IECEx Scheme/SAA, Flameproof (Approval pending) TIIS, Intrinsic safety FM, Intrinsic safety and Nonincendive CSA, Intrinsic safety and Nonincendive ATEX, Intrinsic safety ATEX, Type n IECEx Scheme/SAA, Intrinsic safety FM, Combined of Flameproof and Intrinsic safety <Vent/ drain and mounting bracket> Vent/drain Mounting bracket Standard None Specify "A", or "C" for the 7th Standard Yes, stainless steel digit code "B", "L", or "U" Side None Side Yes, stainless steel <Options> Extra SS tag plate Stainless steel elec. housing Coating of cell None None None Yes None None None Yes None Note3 (*3) Yes Yes None None None Yes Yes None Yes None Yes Yes Yes Yes Yes <Special applications and fill fluid> Treatment Fill fluid Standard Silicone oil Standard Fluorinated oil Degreasing Silicone oil Oxygen service Fluorinated oil (7th digit code "V", "J" only) Chlorine service Fluorinated oil (7th digit code "H", "T" ,"B", "U") NACE specification Silicone oil (Not available for 6th digit code "5", 7th digit code "T", "U", 15th digit code "A", "B") Vacuum service Silicone oil for vacuum use <Sensor O-ring / Gasket> Viton (O-ring) Teflon (gasket) <Bolt/nut> Cr-Mo alloy hexagon socket head cap screw/carbon steel nut Cr-Mo alloy hexagon bolt/nut NACE bolt/nut (ASTM A193 B7M/A194 2HM) Not available for 6th digit NACE bolt/nut (ASTM A320 L7M/A194 2HM) code "5" 304 stainless steel bolt/304 stainless steel nut 630 stainless steel bolt/304 stainless steel nut Available for 6th digit code "5" <Other options> (*4) Note4 Instruction manual unattached Note 3 : (*3) Note 4 : (*4) F KG 0 9 10 11 12 13 14 15 21 4 Digit No. of code A B C D E X R G H J K P T V A C D F Y B C E M N P Q Y W G A D N R A B A B C D E F L Costomer tag number can be engraved on standartd stainless steel name plate. If extra tag plate is required, select "Yes". If other option is not necessary, 21st digit code is blank. In case of 21st digit code is blank, instruction manual attached. 7 FKG...4 ORDERING INFORMATION When ordering this instrument, specify. 1. CODE SYMBOLS 2. Measuring range 3. Output orientation (burnout direction) when abnormality is occured in the transmitter. Hold/Overscale (21.6mA)/Overscale (3.2mA) Unless otherwise specified, output hold function is supplied. 4. Indication method (indicated value and unit) in case of the actual scale (code D,H,P,S on 9th digit). 5. Tag No.(up to 26 alphanumerical characters), if required. 8 OUTLINE DIAGRAM (Unit:mm) < 7th digit code : V, J, H, M, T, J > Vent/drain plug (When the vent/drain plug attatched on the upper side of the detector) Note2) In case of 4th digit code “A.B.C.D.E” In case of 4th digit code “S.V.W.X” In case of 4th digit code “T” “A” Press. conn. Fastener (Flameproof only) φ80 105 105 52.5 Down 41 70 φ80 Up 130 120 43.5 8 94.5 MTG. Pipe JIS 50A (2B) 10 Zero ADJ. screw 88 38 U - bolt M8 58 37 Note1) 210 (189) 4 holes 9 dia. Note3) Cable gland (option) (27) “B” Conduit conn. Vent / drain plug “C” Conduit conn. With field ind. (option) 154 Earth terminal Detail “A” (Press. conn.) φ18.5 Detail “B” (Conduit conn.) H φ15 59 43 Detail “C” φ13 231 (210) 41.3 E 17 8 F Oval flange screw See Table 1 φ7 G 1/2 D Note3) 2.5 Electronics unit Side vent (option) See Table 1 See Table 1 Sensor unit 4-M8×12 4th digit of the code symbols Press. conn. Conduit conn. D A, S G1/2 E 17 F 8 H Rc1/4 B, T 1/2-14NPT 16 5 1/4-18NPT C, V Pg13.5 8 4.5 1/4-18NPT D, W M20×1.5 16 5 1/4-18NPT E, X Pg13.5 8 4.5 1/4-18NPT Oval flange screw 7/16-20UNF Screw depth 15 7/16-20UNF Screw depth 15 M10 Screw depth 15 M10 Screw depth 15 7/16-20UNF Screw depth 15 Table 1 Note1) Cable gland is supplied in case of flamproof packing type. φ11 cable is suitable. Note2) The pressure connector is located on the down side surface of the detector, when the vent / drainplug is attatched on the upper side of the detector. (When the 21st digit of the code symbols : C, E or D). CONNECTION DIAGRAM + – CK+ CK– + 27 70 54 104 – Note3) In case of 6th digit code “5” 9 FKG...4 < 7th digit code : B, L, U > In case of 4th digit code “A.B.C.D.E” U - bolt M8 Fastener (Flameproof only) 94.5 105 52.5 70 φ80 105 Up φ80 Zero ADJ. screw 104 43.5 41.3 10 In case of 4th digit code “T” 8 MTG. Pipe JIS 50A (2B) In case of 4th digit code “S.V.W.X” 41 Down 88 38 58 40 Cable gland (option) 4 holes 9 dia. (27) 213 Note) “C” Conduit conn. “D” Conduit conn. With field ind. Detail “A” (Press. conn.) Detail “C” 4th digit code “A,S” φ16 Earth terminal φ13 60 43 Electronics unit 17 H 0 2 -0.1 1 φ12 +0.2 +0.1 155 Detail “D” (Conduit conn.) φ15 F φ4 E G 1/2 Detail “B” 4th digit code “B, C, D, E, T,V,W,X” View from P Vent / drain plug φ16 234 See Table 1 L.P. P 1/4-18NPT H.P. 10 4-M8×12 “A” or “B” Press. conn. φ4 4th digit of the code symbols Conduit conn. E F H A, S G1/2 17 8 B, T 1/2-14NPT 16 5 C, V Pg13.5 8 4.5 D, W M20×1.5 16 5 E, X Pg13.5 8 4.5 54 70 120 Oval flange screw 7/16-20UNF Screw depth 15 7/16-20UNF Screw depth 15 M10 Screw depth 15 M10 Screw depth 15 7/16-20UNF Screw depth 15 Table 1 Note 1) Cable gland is supplied in case of flamproof packing type. φ11 cable is suitable. 10 98 41.3 Oval flange screw See Table1 CONNECTION DIAGRAM + – CK+ CK– + – Sensor unit 11 FKG...4 Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head Office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation Div. International Sales Dept. No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187 http://www.fic-net.jp/eng Information in this catalog is subject to change without notice. Printed in Japan